Thermosiphon
   HOME

TheInfoList



OR:

A thermosiphon (or thermosyphon) is a device that employs a method of passive heat exchange based on natural
convection Convection is single or Multiphase flow, multiphase fluid flow that occurs Spontaneous process, spontaneously through the combined effects of material property heterogeneity and body forces on a fluid, most commonly density and gravity (see buoy ...
, which circulates a
fluid In physics, a fluid is a liquid, gas, or other material that may continuously motion, move and Deformation (physics), deform (''flow'') under an applied shear stress, or external force. They have zero shear modulus, or, in simpler terms, are M ...
without the necessity of a mechanical pump. Thermosiphoning is used for circulation of liquids and volatile gases in heating and cooling applications such as heat pumps, water heaters, boilers and furnaces. Thermosiphoning also occurs across air temperature gradients such as those occurring in a wood-fire chimney or solar chimney. This circulation can either be open-loop, as when the substance in a holding tank is passed in one direction via a heated transfer tube mounted at the bottom of the tank to a distribution point — even one mounted above the originating tank — or it can be a vertical closed-loop circuit with return to the original container. Its purpose is to simplify the transfer of liquid or gas while avoiding the cost and complexity of a conventional pump.


Simple thermosiphon

Natural convection Convection is single or multiphase fluid flow that occurs spontaneously through the combined effects of material property heterogeneity and body forces on a fluid, most commonly density and gravity (see buoyancy). When the cause of the conve ...
of the liquid starts when
heat transfer Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy (heat) between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, ...
to the liquid gives rise to a temperature difference from one side of the loop to the other. The phenomenon of
thermal expansion Thermal expansion is the tendency of matter to increase in length, area, or volume, changing its size and density, in response to an increase in temperature (usually excluding phase transitions). Substances usually contract with decreasing temp ...
means that a temperature difference will have a corresponding difference in density across the loop. The warmer fluid on one side of the loop is less dense and thus more buoyant than the cooler fluid on the other side. The warmer fluid will "float" above the cooler fluid, and the cooler fluid will "sink" below the warmer fluid. This phenomenon of natural convection is known by the saying "heat rises". Convection moves the heated liquid upwards in the system as it is simultaneously replaced by cooler liquid returning by gravity. A good thermosiphon has very little hydraulic resistance so that liquid can flow easily under the relatively low pressure produced by natural convection.


Heat pipes

In some situations the flow of liquid may be reduced further, or stopped, perhaps because the loop is not entirely full of liquid. In this case, the system no longer convects, so it is not a usual "thermosiphon". Heat can still be transferred in this system by the
evaporation Evaporation is a type of vaporization that occurs on the Interface (chemistry), surface of a liquid as it changes into the gas phase. A high concentration of the evaporating substance in the surrounding gas significantly slows down evapora ...
and
condensation Condensation is the change of the state of matter from the gas phase into the liquid phase, and is the reverse of vaporization. The word most often refers to the water cycle. It can also be defined as the change in the state of water vapor ...
of vapor; however, the system is properly classified as a heat pipe thermosyphon. If the system also contains other fluids, such as air, then the heat flux density will be less than in a real heat pipe, which contains only a single substance. The thermosiphon has been sometimes incorrectly described as a 'gravity return heat pipe'. Heat pipes usually have a wick to return the condensate to the
evaporator An evaporator is a type of heat exchanger device that facilitates evaporation by utilizing conductive and convective heat transfer, which provides the necessary thermal energy for phase transition from liquid to vapour. Within evaporators, a ci ...
via
capillary action Capillary action (sometimes called capillarity, capillary motion, capillary rise, capillary effect, or wicking) is the process of a liquid flowing in a narrow space without the assistance of external forces like Gravitation, gravity. The effe ...
. A wick is not needed in a thermosiphon because gravity moves the liquid. The wick allows heat pipes to transfer heat when there is no gravity, which is useful in space. A thermosiphon is "simpler" than a heat pipe. (Single-phase) thermosiphons can only transfer heat "upward", or away from the acceleration vector. Thus, orientation is much more important for thermosiphons than for heatpipes. Also, thermosiphons can fail because of a bubble in the loop, and require a circulating loop of pipes.


Reboilers and calandria

If the piping of a thermosiphon resists flow, or excessive heat is applied, the liquid may boil. Since the gas is more buoyant than the liquid, the convective pressure is greater. This is a well known invention called a reboiler. A group of reboilers attached to a pair of
plena Plena is a genre of music and dance native to Puerto Rico. Origins The plena genre originated in Barrio San Antón, Ponce, Puerto Rico, around 1900. It was influenced by the bomba style of music. Originally, sung texts were not associated wit ...
is called a calandria. In some circumstances, for example the cooling system for an older (pre 1950s) car, the boiling of the fluid will cause the system to stop working, as the volume of steam created displaces too much of the water and circulation stops. The term "phase change thermosiphon" is a misnomer and should be avoided. When phase change occurs in a thermosiphon, it means that the system either does not have enough fluid, or it is too small to transfer all of the heat by convection alone. To improve the performance, either more fluid is needed (possibly in a larger thermosiphon), or all other fluids (including air) should be pumped out of the loop.


Solar energy

Thermosiphons are used in some liquid-based
solar heating A solar thermal collector collects heat by Absorption (optics), absorbing sunlight. The term "solar collector" commonly refers to a device for solar hot water panel, solar hot water heating, but may refer to large power generating installations ...
systems to heat a liquid such as
water Water is an inorganic compound with the chemical formula . It is a transparent, tasteless, odorless, and Color of water, nearly colorless chemical substance. It is the main constituent of Earth's hydrosphere and the fluids of all known liv ...
. The water is heated passively by
solar energy Solar energy is the radiant energy from the Sun's sunlight, light and heat, which can be harnessed using a range of technologies such as solar electricity, solar thermal energy (including solar water heating) and solar architecture. It is a ...
and relies on heat energy being transferred from the sun to a solar collector. The heat from the collector can be transferred to water in two ways: ''directly'' where water circulates through the collector, or ''indirectly'' where an
anti-freeze An antifreeze is an additive which lowers the freezing point of a water-based liquid. An antifreeze mixture is used to achieve freezing-point depression for cold environments. Common antifreezes also increase the boiling point of the liquid, allow ...
solution carries the heat from the collector and transfers it to water in the tank via a
heat exchanger A heat exchanger is a system used to transfer heat between a source and a working fluid. Heat exchangers are used in both cooling and heating processes. The fluids may be separated by a solid wall to prevent mixing or they may be in direct contac ...
. Convection allows for the movement of the heated liquid out of the solar collector to be replaced by colder liquid which is in turn heated. Due to this principle, it is necessary for the water to be stored in a tank above the collector.


Architecture

In locations historically dominated by permafrost conditions, thermosiphons may be used to counter adverse geologic forces on the foundations of buildings, pipelines and other structures caused by the thawing of the permafrost. A study published in 2006 by oil giant ConocoPhillips reports that Alaska's permafrost, upon which much of the state's infrastructure is built, has degraded since 1982 amid record warm temperatures. According to the Alaska Climate Research Center at the University of Alaska Fairbanks, between 1949 and 2018 the average annual temperature in Alaska rose 4.0 degrees Fahrenheit, with an increase of 7.2 degrees Fahrenheit over the winter.


Computing

Thermosiphons are used for watercooling internal computer components, most commonly the processor. While any suitable liquid can be used, water is the easiest liquid to use in thermosiphon systems. Unlike traditional watercooling systems, thermosiphon systems do not rely on a pump but on convection for the movement of heated water (which may become vapour) from the components upwards to a heat exchanger. There the water is cooled and is ready to be recirculated. The most commonly used heat exchanger is a
radiator A radiator is a heat exchanger used to transfer thermal energy from one medium to another for the purpose of cooling and heating. The majority of radiators are constructed to function in cars, buildings, and electronics. A radiator is always a ...
, where fans actively blow air across an increased surface area to condense the vapour to a liquid. The denser liquid falls, thus recirculating through the system and repeating the process. No pump is required. The cycle of evaporation and condensation is driven by the difference in temperature and gravity.


Uses

Without proper cooling, a modern processor chip can rapidly reach temperatures that cause it to malfunction. Even with a common heat sink and fan attached, typical processor operating temperatures may still reach up to 70 °C (160 °F). A thermosiphon can efficiently transfer heat over a much wider temperature range and can typically maintain the processor temperature 10–20 °C cooler than a traditional heat sink and fan. In some cases, it is also possible that a thermosiphon may cover multiple heat sources and, design-wise, be more compact than an appropriately sized conventional heat sink and fan.


Drawbacks

Thermosiphons must be mounted such that vapor rises up and liquid flows down to the boiler, with no bends in the tubing for liquid to pool. Also, the thermosiphon's fan that cools the gas needs cool air to operate. The system has to be completely airtight; if not, the process of thermosiphon will not take effect and cause the water to only evaporate over a small period of time.


Engine cooling

Some early cars, motor vehicles, and engine-powered farm and industrial equipment used thermosiphon circulation to move cooling water between their
cylinder block In an internal combustion engine, the engine block is the structure that contains the cylinders and other components. The engine block in an early automotive engine consisted of just the cylinder block, to which a separate crankcase was attach ...
and radiator. This method of water circulation depends on keeping enough cool air moving past the radiator to provide a sufficient temperature differential; the air movement was accomplished by the forward motion of the vehicle and by the use of fans. As engine power increased, increased flow of water was required, so engine-driven pumps were added to assist circulation. More compact engines began to use smaller radiators and require more convoluted flow patterns, so the water circulation became entirely dependent on the pump and might even be reversed against its natural direction. An engine that circulates its cooling water only by thermosiphon is susceptible to overheating during prolonged periods of idling or very slow travel since the lack of forward motion provides too little airflow past the radiator, unless one or more fans are able to move enough air by themselves. Thermosiphon systems are also very sensitive to low coolant level, i.e. losing only a small amount of coolant stops the circulation; a pump-driven system is much more robust and can typically handle a lower coolant level.


Espresso machines

Many
espresso machine An espresso machine brews coffee by forcing pressurized water near boiling point through a "puck" of ground coffee and a filter in order to produce a thick, concentrated coffee called espresso. Multiple machine designs have been created to produ ...
designs use a thermosiphon in order to maintain a stable temperature. The E-61 espresso machine has a group head with a thermosiphon. This group head is common on many espresso machines today. Some lever espresso machines have a double wall around the piston in their group that is used for a thermosiphon. A modern example would be the machines from Londinium.


See also

* * * and * * * * * * * *


References


External links


HP Labs report on thermosiphons for computer cooling (PDF)
{{HVAC Computer hardware cooling Heating, ventilation, and air conditioning Convection