Penning ionization is a form of
chemi-ionization, an ionization process involving reactions between neutral atoms or molecules.
The Penning effect is put to practical use in applications such as gas-discharge
neon lamp
A neon lamp (also neon glow lamp) is a miniature gas discharge lamp. The lamp typically consists of a small glass capsule that contains a mixture of neon and other gases at a low pressure and two electrodes (an anode and a cathode). When suffi ...
s and
fluorescent lamp
A fluorescent lamp, or fluorescent tube, is a low-pressure mercury-vapor gas-discharge lamp that uses fluorescence to produce visible light. An electric current in the gas excites mercury vapor, which produces short-wave ultraviolet li ...
s, where the lamp is filled with a
Penning mixture
A Penning mixture, named after Frans Michel Penning, is a mixture of gases used in electric lighting or displaying fixtures. Although the popular phrase for the most common of these is a neon lamp, it is more efficient to have the glass tube fill ...
to improve the electrical characteristics of the lamps.
History
The process is named after the Dutch physicist
Frans Michel Penning
Frans Michel Penning (12 September 1894 – 6 December 1953) was a Dutch experimental physicist. He received his PhD from the University of Leiden in 1923, and studied low pressure gas discharges at the Philips Laboratory in Eindhoven, developing ...
who first reported it in 1927. Penning started to work at the Philips Natuurkundig Laboratorium at Eindhoven to continue the investigation of electric discharge on rare gases. Later, he started measurements on the liberation of electrons from metal surfaces by positive ions and metastable atoms, and especially on the effects related to ionization by metastable atoms.
Reaction
Penning ionization refers to the interaction between an electronically excited gas-phase atom G
* and a target molecule M. The collision results in the ionization of the molecule yielding a cation M
+., an electron e
−, and a neutral gas molecule, G, in the ground state. Penning ionization occurs via formation of a high energy collision complex, evolving toward the formation of a cationic species, by ejecting a high energy electron.
:
+ M -> + + G

Penning ionization occurs when the target molecule has an
ionization potential
Ionization, or Ionisation is the process by which an atom or a molecule acquires a negative or positive charge by gaining or losing electrons, often in conjunction with other chemical changes. The resulting electrically charged atom or molecule ...
lower than the excited energy of the excited-state atom or molecule.
Variants
When the total electron excitation energy of colliding particles is sufficient, then the bonding energy of two particles that bonded together can also be contributed into the associative penning ionization act.
Associative
In mathematics, the associative property is a property of some binary operations, which means that rearranging the parentheses in an expression will not change the result. In propositional logic, associativity is a valid rule of replacement ...
Penning ionization can also occur:
:
+ M -> + e^-
Surface Penning ionization (Auger Deexcitation) refers to the interaction of the excited-state gas with a surface S, resulting in the release of an electron:
:
+ S -> + + e^-
The positive charge symbol
S+ that would appear to be required for charge conservation is omitted, because S is a macroscopic surface and the loss of one electron has a negligible effect.
Applications
Electron spectroscopy
Penning ionization has been applied to Penning ionization electron spectroscopy (PIES)for
gas chromatography
Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, ...
detector in glow discharge by using the reaction for He or Ne.
The kinetic energy of electron ejected is analyzed by the collisions between target (gas or solid) and metastable atoms by scanning the retarding field in a flight tube of the analyzer in the presence of a weak magnetic field.
The electron produced by reaction has a kinetic energy E determined by:
:
The Penning ionization electron energy does not depend on the conditions of the experiments or any other species since both E and IE are atomic or molecular constants of the energy of He and the ionization energy for the species.
Penning ionization electron spectroscopy applied to organic solids. It enables the study of local electron distribution of individual molecular orbitals, which exposes to the outside of the outermost surface layers.
Mass spectrometry
Multiple mass spectrometric techniques, including glow discharge mass spectrometry and
direct analysis in real time In mass spectrometry, direct analysis in real time (DART) is an ion source that produces electronically or vibronically excited-state species from gases such as helium, argon, or nitrogen that ionize atmospheric molecules or dopant molecules. The ...
mass spectrometry rely on Penning ionization.
Glow discharge mass spectrometry is the direct determination of trace element in solid samples. It occurs with two ionization mechanisms: the direct electron impact ionization and Penning ionization. Processes inherent to the glow discharge, namely cathodic sputtering coupled with Penning ionization, yield an ion
population from which semi-quantitative results can be directly obtained.
See also
*
Chemical ionization
Chemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966. This technique is a branch of gaseous ion-molecule chemistry. Reagent gas molecules (often ...
References
{{reflist
Ion source
Electron spectroscopy