A sphygmomanometer ( ), also known as a blood pressure monitor, blood pressure machine, or blood pressure gauge, is a device used to measure
blood pressure Blood pressure (BP) is the pressure of Circulatory system, circulating blood against the walls of blood vessels. Most of this pressure results from the heart pumping blood through the circulatory system. When used without qualification, the term ...
, composed of an inflatable
cuff A cuff is a layer of fabric at the lower edge of the sleeve of a garment (shirt, coat, jacket, etc.) at the wrist, or at the ankle end of a trouser leg. The function of turned-back cuffs is to protect the cloth of the garment from fraying, and, ...
to collapse and then release the artery under the cuff in a controlled manner, and a mercury or aneroid
manometer Pressure measurement is the measurement of an applied force by a fluid (liquid or gas) on a surface. Pressure is typically measured in units of force per unit of surface area. Many techniques have been developed for the measurement of pressu ...
to measure the pressure. Manual sphygmomanometers are used with a
stethoscope The stethoscope is a medicine, medical device for auscultation, or listening to internal sounds of an animal or human body. It typically has a small disc-shaped resonator that is placed against the skin, with either one or two tubes connected t ...
when using the auscultatory technique. A sphygmomanometer consists of an inflatable cuff, a measuring unit (the mercury manometer, or aneroid gauge), and a mechanism for inflation which may be a manually operated bulb and valve or a pump operated electrically.


Etymology

The word ''sphygmomanometer'' uses the
combining form Neoclassical compounds are compound words composed from combining forms (which act as affixes or stems) derived from classical languages (classical Latin or ancient Greek) roots. Neo-Latin comprises many such words and is a substantial componen ...
of '' sphygmo-'' + ''
manometer Pressure measurement is the measurement of an applied force by a fluid (liquid or gas) on a surface. Pressure is typically measured in units of force per unit of surface area. Many techniques have been developed for the measurement of pressu ...
''. The roots involved are as follows:
Greek Greek may refer to: Anything of, from, or related to Greece, a country in Southern Europe: *Greeks, an ethnic group *Greek language, a branch of the Indo-European language family **Proto-Greek language, the assumed last common ancestor of all kno ...
''sphygmos'' "pulse", plus the scientific term ''
manometer Pressure measurement is the measurement of an applied force by a fluid (liquid or gas) on a surface. Pressure is typically measured in units of force per unit of surface area. Many techniques have been developed for the measurement of pressu ...
'' (from French ''manomètre''), i.e. "pressure meter", itself coined from ''manos'' "thin, sparse", and ''metron'' "measure". Most sphygmomanometers were mechanical gauges with dial faces, or mercury columns, during most of the 20th century. Since the advent of electronic
medical device A medical device is any device intended to be used for medical purposes. Significant potential for hazards are inherent when using a device for medical purposes and thus medical devices must be proved safe and effective with reasonable assura ...
s, names such as "meter" and "monitor" can also apply, as devices can automatically
monitor Monitor or monitor may refer to: Places * Monitor, Alberta * Monitor, Indiana, town in the United States * Monitor, Kentucky * Monitor, Oregon, unincorporated community in the United States * Monitor, Washington * Monitor, Logan County, Wes ...
blood pressure on an ongoing basis.


History

The sphygmomanometer was invented by Samuel Siegfried Karl Ritter von Basch in the year 1881. Scipione Riva-Rocci introduced a more easily-usable version in 1896. In 1901, pioneering
neurosurgeon Neurosurgery or neurological surgery, known in common parlance as brain surgery, is the medical specialty that focuses on the surgical treatment or rehabilitation of disorders which affect any portion of the nervous system including the brain, ...
Dr. Harvey Cushing brought an example of Riva-Rocci's device to the US, modernized and popularized it within the medical community. Further improvement came in 1905 when Russian physician
Nikolai Korotkov Nikolai Sergeyevich Korotkov, also Korotkoff (; – 14 March 1920) was a Russian Empire, Russian surgeon, a pioneer of 20th-century vascular surgery, and the inventor of auscultatory technique for blood pressure, blood pressure measurement. B ...
included diastolic blood pressure measurement following his discovery of "Korotkoff sounds". William A. Baum invented the Baumanometer brand in 1916, while working for The Life Extension Institute which performed insurance and employment physicals.


Types

Both manual and digital meters are currently employed, with different trade-offs in accuracy versus convenience. File:2020 Sfigmomanometr elektroniczny.jpg, BP 138/73
mmHg A millimetre of mercury is a manometric unit of pressure, formerly defined as the extra pressure generated by a column of mercury one millimetre high. Currently, it is defined as exactly , or approximately 1 torr =  atmosphere = &nb ...
as result on electronic sphygmomanometer File:Sphygmomanometer&Cuff.JPG, Aneroid sphygmomanometer with an adult cuff File:Sphygmomanometer.JPG, Aneroid sphygmomanometer dial, bulb, and air valve File:Clinical Mercury Manometer.jpg, Clinical mercury manometer File:Advanced Digital Sphygmomanometer.jpg, Clinical WelchAllyn sphygmomanometer


Manual

A stethoscope is required for
auscultation Auscultation (based on the Latin verb ''auscultare'' "to listen") is listening to the internal sounds of the body, usually using a stethoscope. Auscultation is performed for the purposes of examining the circulatory system, circulatory and resp ...
( see below). Manual meters are best used by trained practitioners, and, while it is possible to obtain a basic reading through
palpation Palpation is the process of using one's hands to check the body, especially while perceiving/diagnosing a disease or illness. Usually performed by a health care practitioner, it is the process of feeling an object in or on the body to determine ...
alone, this yields only the systolic pressure. * Mercury sphygmomanometers are considered the
gold standard A gold standard is a backed currency, monetary system in which the standard economics, economic unit of account is based on a fixed quantity of gold. The gold standard was the basis for the international monetary system from the 1870s to the ...
. They indicate pressure with a column of mercury, which does not require recalibration. Because of their accuracy, they are often used in
clinical trial Clinical trials are prospective biomedical or behavioral research studies on human subject research, human participants designed to answer specific questions about biomedical or behavioral interventions, including new treatments (such as novel v ...
s of drugs and in clinical evaluations of high-risk patients, including pregnant women. A frequently used wall mounted mercury sphygmomanometer is also known as a Baumanometer. * Aneroid sphygmomanometers (mechanical types with a dial) are in common use; they may require calibration checks, unlike mercury manometers. Aneroid sphygmomanometers are considered safer than mercury sphygmomanometers, although inexpensive ones are less accurate. A major cause of departure from calibration is mechanical jarring. Aneroids mounted on walls or stands are not susceptible to this particular problem.


Digital

Digital Digital usually refers to something using discrete digits, often binary digits. Businesses *Digital bank, a form of financial institution *Digital Equipment Corporation (DEC) or Digital, a computer company *Digital Research (DR or DRI), a software ...
meters employ oscillometric measurements and electronic calculations rather than auscultation. They may use manual or automatic inflation, but both types are electronic, easy to operate without training, and can be used in noisy environments. They calculate systolic and diastolic pressures by oscillometric detection, employing either deformable membranes that are measured using differential capacitance, or differential piezoresistance, and they include a
microprocessor A microprocessor is a computer processor (computing), processor for which the data processing logic and control is included on a single integrated circuit (IC), or a small number of ICs. The microprocessor contains the arithmetic, logic, a ...
. They estimate mean arterial blood pressure and measure pulse rate; while systolic and diastolic pressures are obtained less accurately than with manual meters, and calibration is also a concern. Digital oscillometric monitors may not be advisable for some patients, such as those with
arteriosclerosis Arteriosclerosis, literally meaning "hardening of the arteries", is an umbrella term for a vascular disorder characterized by abnormal thickening, hardening, and loss of elasticity of the walls of arteries; this process gradually restricts th ...
,
arrhythmia Arrhythmias, also known as cardiac arrhythmias, are irregularities in the cardiac cycle, heartbeat, including when it is too fast or too slow. Essentially, this is anything but normal sinus rhythm. A resting heart rate that is too fast – ab ...
,
preeclampsia Pre-eclampsia is a multi-system disorder specific to pregnancy, characterized by the new onset of high blood pressure and often a significant amount of protein in the urine or by the new onset of high blood pressure along with significant end- ...
, '' pulsus alternans'', and '' pulsus paradoxus'', as their calculations may not be correct for these conditions, and in these cases, an analog sphygmomanometer is preferable when used by a trained person. Digital instruments may use a cuff placed, in order of accuracy and inverse order of portability and convenience, around the upper arm, the wrist, or a finger. Recently, a group of researchers at Michigan State University developed a smartphone based device that uses oscillometry to estimate blood pressure. The oscillometric method of detection used gives blood pressure readings that differ from those determined by auscultation, and vary according to many factors, such as
pulse pressure Pulse pressure is the difference between systolic and diastolic blood pressure. It is measured in millimeters of mercury (mmHg). It represents the force that the heart generates each time it contracts. Healthy pulse pressure is around 40  ...
,
heart rate Heart rate is the frequency of the cardiac cycle, heartbeat measured by the number of contractions of the heart per minute (''beats per minute'', or bpm). The heart rate varies according to the body's Human body, physical needs, including the nee ...
and
arterial stiffness Arterial stiffness occurs as a consequence of biological aging, arteriosclerosis and genetic disorders, such as Marfan, Williams, and Ehlers-Danlos syndromes. Inflammation plays a major role in arteriosclerosis and arterial stiffness. Incre ...
, although some instruments are claimed also to measure arterial stiffness, and some can detect irregular heartbeats.


Operation

In humans, the cuff is normally placed smoothly and snugly around an upper arm, at roughly the same vertical height as the
heart The heart is a muscular Organ (biology), organ found in humans and other animals. This organ pumps blood through the blood vessels. The heart and blood vessels together make the circulatory system. The pumped blood carries oxygen and nutrie ...
while the subject is seated with the arm supported. Other sites of placement depend on species and may include the flipper or tail. It is essential that the correct size of cuff is selected for the patient. Too small a cuff results in too high a pressure, while too large a cuff results in too low a pressure. For clinical measurements it is usual to measure and record both arms in the initial consultation to determine if the pressure is significantly higher in one arm than the other. A difference of 10 mmHg may be a sign of
coarctation of the aorta Coarctation of the aorta (CoA) is a congenital condition whereby the aorta is narrow, usually in the area where the ductus arteriosus ( ligamentum arteriosum after regression) inserts. The word ''coarctation'' means "pressing or drawing toget ...
. If the arms read differently, the higher reading arm would be used for later readings. The cuff is inflated until the
artery An artery () is a blood vessel in humans and most other animals that takes oxygenated blood away from the heart in the systemic circulation to one or more parts of the body. Exceptions that carry deoxygenated blood are the pulmonary arteries in ...
is completely occluded. With a manual instrument, listening with a
stethoscope The stethoscope is a medicine, medical device for auscultation, or listening to internal sounds of an animal or human body. It typically has a small disc-shaped resonator that is placed against the skin, with either one or two tubes connected t ...
to the
brachial artery The brachial artery is the major blood vessel of the (upper) arm. It is the continuation of the axillary artery beyond the lower margin of teres major muscle. It continues down the ventral surface of the arm until it reaches the cubital fossa ...
, the examiner slowly releases the pressure in the cuff at a rate of approximately 2 mmHg per heart beat. As the pressure in the cuffs falls, a "whooshing" or pounding sound is heard (see
Korotkoff sounds Korotkoff sounds are the sounds that medical personnel listen for when they are taking blood pressure using a non-invasive (medical), non-invasive procedure. They are named after Nikolai Korotkov, a Russian physician who discovered them in 1905, wh ...
) when blood flow first starts again in the artery. The pressure at which this sound began is noted and recorded as the
systolic blood pressure Blood pressure (BP) is the pressure of circulating blood against the walls of blood vessels. Most of this pressure results from the heart pumping blood through the circulatory system. When used without qualification, the term "blood pressure" r ...
. The cuff pressure is further released until the sound can no longer be heard. This is recorded as the diastolic blood pressure. In noisy environments where auscultation is impossible (such as the scenes often encountered in
emergency medicine Emergency medicine is the medical specialty concerned with the care of illnesses or injuries requiring immediate medical attention. Emergency physicians (or "ER doctors") specialize in providing care for unscheduled and undifferentiated pa ...
), systolic blood pressure alone may be read by releasing the pressure until a radial
pulse In medicine, the pulse refers to the rhythmic pulsations (expansion and contraction) of an artery in response to the cardiac cycle (heartbeat). The pulse may be felt ( palpated) in any place that allows an artery to be compressed near the surfac ...
is palpated (felt). In veterinary medicine, auscultation is rarely of use, and palpation or visualization of pulse distal to the sphygmomanometer is used to detect systolic pressure. Digital instruments use a cuff which may be placed, according to the instrument, around the upper arm, wrist, or a finger, in all cases elevated to the same height as the heart. They inflate the cuff and gradually reduce the pressure in the same way as a manual meter, and measure blood pressures by the oscillometric method.


Significance

By observing the mercury in the column, or the aneroid gauge pointer, while releasing the air pressure with a control valve, the operator notes the values of the blood pressure in mmHg. The peak pressure in the arteries during the
cardiac cycle The cardiac cycle is the performance of the heart, human heart from the beginning of one heartbeat to the beginning of the next. It consists of two periods: one during which the heart muscle relaxes and refills with blood, called diastole, fo ...
is the systolic pressure, and the lowest pressure (at the resting phase of the cardiac cycle) is the diastolic pressure. A stethoscope, applied lightly over the artery being measured, is used in the auscultatory method. Systolic pressure (first phase) is identified with the first of the continuous Korotkoff sounds. Diastolic pressure is identified at the moment the Korotkoff sounds disappear (fifth phase). Measurement of the blood pressure is carried out in the diagnosis and treatment of
hypertension Hypertension, also known as high blood pressure, is a Chronic condition, long-term Disease, medical condition in which the blood pressure in the artery, arteries is persistently elevated. High blood pressure usually does not cause symptoms i ...
(high blood pressure), and in many other healthcare scenarios.


See also

* * Critical closing pressure


References


External links

* * * * {{US patent reference , number = 6752764 , inventor = Man S. Oh , title = Pocket sphygmomanometer , y = 2004, m = 06, d = 22 1881 introductions 19th-century inventions Austrian inventions Blood pressure Medical equipment Physiological instruments Pressure gauges