Sprinkler Head
   HOME

TheInfoList



OR:

A fire sprinkler or sprinkler head is the component of a
fire sprinkler system A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used on ...
that discharges
water Water is an inorganic compound with the chemical formula . It is a transparent, tasteless, odorless, and Color of water, nearly colorless chemical substance. It is the main constituent of Earth's hydrosphere and the fluids of all known liv ...
when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by properly designed and maintained fire sprinklers, over 99% of fires were controlled by fire sprinklers alone.


History

In 1812, British inventor Sir William Congreve patented a manual sprinkler system using perforated pipes along the ceiling. When someone noticed a fire, a valve outside the building could be opened to send water through the pipes. It was not until a short time later that, as a result of a large furniture factory that repeatedly burned down,
Hiram Stevens Maxim Sir Hiram Stevens Maxim (5 February 1840 – 24 November 1916) was an American-born British inventor best known as the creator of the first automatic machine gun, the Maxim gun. Maxim held patents on numerous mechanical devices such as hai ...
was consulted on how to prevent a recurrence and invented the first automatic fire sprinkler. It would douse the areas that were on fire and report the fire to the fire station. Maxim was unable to sell the idea elsewhere, though when the patent expired, the idea was used. In 1872,
Thomas J. Martin Thomas J. Martin (1842–1872) was awarded a patent for improvement to the fire extinguisher in 1872. The invention involved the use of pipes to carry water upwards and valves in the ceiling acting as sprinklers to extinguish fires in buildi ...
was awarded a patent for improvement to the
fire extinguisher A fire extinguisher is a handheld active fire protection device usually filled with a dry or wet chemical used to extinguish or control small fires, often in emergencies. It is not intended for use on an out-of-control fire, such as one which ha ...
which involved the use of pipes to carry water upwards and valves in the ceiling acting as sprinklers to extinguish fires in buildings. In 1874, Henry S. Parmalee of
New Haven, Connecticut New Haven is a city of the U.S. state of Connecticut. It is located on New Haven Harbor on the northern shore of Long Island Sound. With a population of 135,081 as determined by the 2020 United States census, 2020 U.S. census, New Haven is List ...
, created and installed the first automatic
fire sprinkler system A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used on ...
, using
solder Solder (; North American English, NA: ) is a fusible alloy, fusible metal alloy used to create a permanent bond between metal workpieces. Solder is melted in order to wet the parts of the joint, where it adheres to and connects the pieces aft ...
that melted in a fire to unplug holes in the otherwise sealed water pipes. He was the president of Mathusek Piano Works, and invented his sprinkler system in response to exorbitantly high insurance rates. Parmelee patented his idea and had great success with it in the U.S., calling his invention the "automatic fire extinguisher". He then traveled to Europe to demonstrate his method to stop a building fire before total destruction. Parmelee's invention did not get as much attention as he had planned, as most people could not afford to install a sprinkler system. Once he realized this, he turned his efforts to educating insurance companies about his system. He explained that the sprinkler system would reduce the loss ratio, and thus save money for the insurance companies. He knew that he could never succeed in obtaining contracts from the business owners to install his system unless he could ensure for them a reasonable return in the form of reduced premiums. In this connection, he was able to enlist the interest of two men, who both had connections in the insurance industry. The first of was Major Hesketh, a cotton spinner in a large business in
Bolton Bolton ( , locally ) is a town in Greater Manchester in England. In the foothills of the West Pennine Moors, Bolton is between Manchester, Blackburn, Wigan, Bury, Greater Manchester, Bury and Salford. It is surrounded by several towns and vill ...
who was also chairman of the Bolton Cotton Trades Mutual Insurance Company. The directors of this company and its secretary, Peter Kevan, took an interest in Parmelee's early experiments. Hesketh got Parmelee his first order for sprinkler installations in the cotton spinning mills of John Stones & Company, at Astley Bridge, Bolton. This was followed soon afterwards by an order from the Alexandra Mills, owned by John Butler of the same town. Although Parmelee got two sales through its efforts, the Bolton Cotton Trades Mutual Insurance Company was not a very big company outside of its local area. Parmelee needed a wider influence. He found this influence in James North Lane, the manager of the Mutual Fire Insurance Corporation of
Manchester Manchester () is a city and the metropolitan borough of Greater Manchester, England. It had an estimated population of in . Greater Manchester is the third-most populous metropolitan area in the United Kingdom, with a population of 2.92&nbs ...
. This company was founded in 1870 by the Textile Manufacturers' Associations of
Lancashire Lancashire ( , ; abbreviated ''Lancs'') is a ceremonial county in North West England. It is bordered by Cumbria to the north, North Yorkshire and West Yorkshire to the east, Greater Manchester and Merseyside to the south, and the Irish Sea to ...
and
Yorkshire Yorkshire ( ) is an area of Northern England which was History of Yorkshire, historically a county. Despite no longer being used for administration, Yorkshire retains a strong regional identity. The county was named after its county town, the ...
as a protest against high insurance rates. They had a policy of encouraging risk management and more particularly the use of the most up-to-date and scientific apparatus for extinguishing fires. Even though he put tremendous effort and time into educating the masses on his sprinkler system, by 1883 only about 10 factories were protected by the Parmelee sprinkler. Back in the U.S.,
Frederick Grinnell Frederick Grinnell (August 14, 1836 – October 21, 1905) was a pioneer in fire safety and was the creator of the first practical automatic fire sprinkler. Early life and education He was born in New Bedford, Massachusetts. In 1855, he graduated f ...
, who was manufacturing the Parmelee sprinkler, designed the more effective Grinnell sprinkler. He increased sensitivity by removing the fusible joint from all contact with the water, and, by seating a valve in the center of a flexible diaphragm, he relieved the low-fusing soldered joint of the strain of water pressure. By this means, the valve seat was forced against the valve by the water pressure, producing a self-closing action. The greater the water pressure, the tighter the valve. The flexible diaphragm had a further and more important function. It caused the valve and its seat to move outwards simultaneously until the solder joint was completely severed. Grinnell got a patent for his version of the sprinkler system. He also took his invention to Europe, where it was a much bigger success than the Parmelee version. Eventually, the Parmelee system was withdrawn, opening the path for Grinnell and his invention.


US regulations

Fire sprinkler application and installation guidelines, and overall fire sprinkler system design guidelines are provided by the
National Fire Protection Association The National Fire Protection Association (NFPA) is a U.S.-based international nonprofit organization devoted to eliminating death, injury, property damage, and economic loss due to fire, electrical, and related hazards. , the NFPA claims to have 5 ...
(NFPA) 13, (NFPA) 13D, and (NFPA) 13R and enforced by local jurisdictions. Certain states, including
California California () is a U.S. state, state in the Western United States that lies on the West Coast of the United States, Pacific Coast. It borders Oregon to the north, Nevada and Arizona to the east, and shares Mexico–United States border, an ...
,
Pennsylvania Pennsylvania, officially the Commonwealth of Pennsylvania, is a U.S. state, state spanning the Mid-Atlantic (United States), Mid-Atlantic, Northeastern United States, Northeastern, Appalachian, and Great Lakes region, Great Lakes regions o ...
and
Illinois Illinois ( ) is a U.S. state, state in the Midwestern United States, Midwestern United States. It borders on Lake Michigan to its northeast, the Mississippi River to its west, and the Wabash River, Wabash and Ohio River, Ohio rivers to its ...
, require sprinklers in at least some new residential construction. Fire sprinklers can be automatic or open orifice. Automatic fire sprinklers use a fusible element that activates at a predetermined temperature. The fusible element either melts or has a frangible liquid-containing glass bulb that breaks, causing the water pressure in the fire sprinkler piping to push a plug out of the sprinkler orifice, resulting in water spraying from the orifice. The water stream strikes a deflector that forms the water into a spray pattern designed in support of the goals of the sprinkler type (i.e., control or suppression). Modern sprinkler heads are designed to direct spray downwards. Spray nozzles are available to provide spray in various directions and patterns. The majority of automatic fire sprinklers operate individually in a fire. Contrary to motion picture representation, the entire sprinkler system does not activate at the same time, unless the system is a special deluge type. Open orifice sprinklers are only used in water spray systems or deluge sprinklers systems. They are identical to the automatic sprinkler on which they are based, with the heat-sensitive operating element removed. Automatic fire sprinklers utilizing frangible bulbs follow a standardized color-coding convention indicating their
operating temperature An operating temperature is the allowable temperature range of the local ambient environment at which an electrical or mechanical device operates. The device will operate effectively within a specified temperature range which varies based on the de ...
. Activation temperatures correspond to the type of hazard against which the sprinkler system protects. Residential occupancies are provided with a special type of fast response sprinkler with the unique goal of life safety (a residential sprinkler has a higher discharge pattern than that of a standard spray sprinkler and they also have been specifically developed for discharging water higher on the walls in order to keep ceiling gas temperatures lower).


Quick response sprinklers

The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the temperature of the hot air stream times the square root of the velocity of the air stream. The term quick response refers to the listing of the entire sprinkler (including spacing, density and location) not just the fast responding releasing element. Many standard response sprinklers, such as extended coverage ordinary hazard (ECOH) sprinklers, have fast responding (low thermal mass elements) in order to pass their fire tests. Quick response sprinklers are available with standard spray deflectors, but they are also available with extended coverage deflectors.


Operation

Each closed-head sprinkler is held closed by either a heat-sensitive glass bulb (see below) or a two-part metal link held together with a
fusible alloy A fusible alloy is a metal alloy capable of being easily fused, i.e. easily meltable, at relatively low temperatures. Fusible alloys are commonly, but not necessarily, eutectic alloys. Sometimes the term "fusible alloy" is used to describe alloy ...
such as
Wood's metal Wood's metal, also known as Lipowitz's alloy or by the commercial names Cerrobend, Bendalloy, Pewtalloy and MCP 158, is a fusible metal alloy (having a low melting point) that is useful for soldering and making custom metal parts. The alloy is n ...
and other alloys with similar compositions. The glass bulb or link applies pressure to a pipe cap which acts as a plug which prevents water from flowing until the ambient temperature around the sprinkler reaches the design activation temperature of the individual sprinkler. Because each sprinkler activates independently when the predetermined heat level is reached, the number of sprinklers that operate is limited to only those near the fire, thereby maximizing the available water pressure over the point of fire origin. The bulb breaks as a result of the
thermal expansion Thermal expansion is the tendency of matter to increase in length, area, or volume, changing its size and density, in response to an increase in temperature (usually excluding phase transitions). Substances usually contract with decreasing temp ...
of the liquid inside the bulb. The time it takes before a bulb breaks is dependent on the temperature. Below the design temperature, it does not break, and above the design temperature, it breaks, taking less time to break as temperature increases above the design threshold. The response time is expressed as a response time index (RTI), which typically has values between 35 and 250 m½s½, where a low value indicates a fast response. Under standard testing procedures (135 °C air at a velocity of 2.5 m/s), a 68 °C sprinkler bulb will break within 7 to 33 seconds, depending on the RTI. The RTI can also be specified in imperial units, where 1 ft½s½ is equivalent to 0.55 m½s½. The sensitivity of a sprinkler can be negatively affected if the thermal element has been painted. From Table 6.2.5.1 NFPA13 2007 Edition indicates the maximum ceiling temperature, nominal operating temperature of the sprinkler, color of the bulb or link and the temperature classification.


Types

There are several types of sprinklers: * Quick response * Standard response * CMSA (control mode specific application) * Residential * ESFR (early suppression fast response)


ESFR

ESFR (early suppression fast response) refers to both a concept and a type of sprinkler. "The concept is that fast response of sprinklers can produce an advantage in a fire if the response is accompanied by an effective discharge density — that is, a sprinkler spray capable of fighting its way down through the fire plume in sufficient quantities to suppress the burning fuel package." The sprinkler that was developed for this concept was created for use in high rack storage. ESFR sprinkler heads were developed in the 1980s to take advantage of the latest fast-response fire sprinkler technology to provide fire suppression of specific high-challenge fire hazards. Prior to the introduction of these sprinklers, protection systems were designed to control fires until the arrival of the
fire department A fire department (North American English) or fire brigade (English in the Commonwealth of Nations, Commonwealth English), also known as a fire company, fire authority, fire district, fire and rescue, or fire service in some areas, is an organi ...
.


See also

*
Active fire protection Active fire protection (AFP) is an integral part of fire protection. AFP is characterized by items and/or systems, which require a certain amount of motion and response in order to work, contrary to passive fire protection. Categories Manual f ...
*
Automatic fire suppression Automatic fire suppression systems control and extinguish fires without human intervention. Examples of automatic systems include fire sprinkler system, gaseous fire suppression, and condensed aerosol fire suppression. When fires are extinguishe ...
*
Building code A building code (also building control or building regulations) is a set of rules that specify the standards for construction objects such as buildings and non-building structures. Buildings must conform to the code to obtain planning permis ...
* Fire Safety Evaluation System * Hydraulic calculation * K-factor (fire protection) *
Piping Within industry, piping is a system of pipes used to convey fluids (liquids and gases) from one location to another. The engineering discipline of piping design studies the efficient transport of fluid. Industrial process piping (and accomp ...
*
Tyco International Tyco International was a security systems company incorporated in the Republic of Ireland, with operational headquarters in Princeton, New Jersey, United States (Tyco International (US) Inc.). Tyco International was composed of two major busin ...
*
Victaulic Victaulic is a developer and manufacturer of mechanical pipe joining systems, and the originator of the grooved pipe couplings joining system. The firm is a global company with 15 major manufacturing facilities, 28 branches, and over 3,600 empl ...


References


External links

* * {{Fire protection Firefighting equipment Fire suppression Active fire protection American inventions