HOME

TheInfoList



OR:

Smoke testing refers to various classes of tests of systems, usually intended to determine whether they are ready for more robust testing. The expression probably was first used in
plumbing Plumbing is any system that conveys fluids for a wide range of applications. Plumbing uses pipes, valves, plumbing fixtures, tanks, and other apparatuses to convey fluids. Heating and cooling (HVAC), waste removal, and potable water deliver ...
in referring to tests for the detection of cracks, leaks or breaks in closed systems of pipes. Pre-dating the term itself, smoke tests were performed to detect leaks in wooden sailing vessels at least as early as 1836. After making a slow fire in the bottom of the hold, Richard Henry Dana writes, "Wherever smoke was seen coming out we calked and pasted and, so far as we could, make the ship smoke tight."


History of the term

The plumbing industry started using the smoke test in 1875.Buchan, W.P
Institution of the Smoke-Test for Drains
Read before the Royal Scottish Society of Arts, 13 April 1891. Retrieved 2011-06-24.


Smoke testing in various industries


Plumbing

In
plumbing Plumbing is any system that conveys fluids for a wide range of applications. Plumbing uses pipes, valves, plumbing fixtures, tanks, and other apparatuses to convey fluids. Heating and cooling (HVAC), waste removal, and potable water deliver ...
a smoke test forces non-toxic, artificially created smoke through waste and drain pipes under a slight pressure to find leaks. Plumes of smoke form where there are defects. This test can be performed when the plumbing is brand new, but more often it is used to find sewer gas leaks that may plague a building or an area. Any sign of smoke escaping can be considered a possible site for sewer gas to escape. Sewer gas typically has a rotten egg smell and can contain
methane gas Methane ( , ) is a chemical compound with the chemical formula (one carbon atom bonded to four hydrogen atoms). It is a group-14 hydride, the simplest alkane, and the main constituent of natural gas. The relative abundance of methane on Ear ...
, which is explosive, or
hydrogen sulfide Hydrogen sulfide is a chemical compound with the formula . It is a colorless chalcogen-hydride gas, and is poisonous, corrosive, and flammable, with trace amounts in ambient atmosphere having a characteristic foul odor of rotten eggs. The und ...
gas, which is deadly. Plumbing smoke tests are also used to find places where pipes will spill fluid, and to check
sanitary sewer A sanitary sewer is an underground pipe or tunnel system for transporting sewage from houses and commercial buildings (but not stormwater) to a sewage treatment plant or disposal. Sanitary sewers are a type of gravity sewer and are part of ...
systems for places where ground water and storm runoff can enter. Smoke testing is particularly useful in places such as ventilated sanitary sewer systems, where completely sealing the system is not practical. When smoke testing a
sanitary sewer A sanitary sewer is an underground pipe or tunnel system for transporting sewage from houses and commercial buildings (but not stormwater) to a sewage treatment plant or disposal. Sanitary sewers are a type of gravity sewer and are part of ...
system it is helpful to partially block off the section of sewer to be tested. This can be done by using a sand bag on the end of a rope. The sand bag is lowered into the manhole and swung into position to partially block lines. Completely blocking the line can cause water to back up and prevent smoke from escaping through defects. Smoke testing may not be done after rain or when ground water is unusually high as this may also prevent detection of defects. Large downdraft fans, usually powered by gasoline engines, are placed on top of open
manhole A manhole (utility hole, maintenance hole, or sewer hole) is an opening to a confined space such as a shaft, utility vault, or large vessel. Manholes are often used as an access point for an underground public utility, allowing inspection, ...
s at either end of the section to be tested. If possible all lines in the manholes except for the line between the manholes are partially blocked. Smoke is created using either a
smoke bomb A smoke bomb is a firework designed to produce a large amount of smoke upon ignition. History Early Japanese history saw the use of a rudimentary form of the smoke bomb. Explosives were common in Japan during the Mongol invasions of the 13 ...
or liquid smoke. Smoke bombs are lit and placed on a grate or in a holder on top of each fan, while liquid smoke is injected into the fan via a heating chamber. The fans create a pressure differential that forces the smoke into the sewer at a pressure just above atmospheric. With properly installed plumbing, the
traps TNF receptor associated periodic syndrome (TRAPSsubscription needed) is a periodic fever syndrome associated with mutations in a receptor (biochemistry), receptor for the molecule tumor necrosis factors, tumor necrosis factor (TNF) that is inheri ...
will prevent the smoke from entering the house and redirect it out the plumbing vents. Defective plumbing systems or dry traps will allow smoke to enter the inside of the house. The area around the section being tested is searched for smoke plumes. Plumes coming from plumbing vents or the interface between the fan shroud and manhole rim are normal; however, smoke plumes outside of the manhole rim are not. Plumes are marked, usually with flags, and defects are noted using measurements from stationary landmarks like the corners of houses. The plumes or markers may also be photographed.


Woodwind instrument repair

In
woodwind instrument Woodwind instruments are a family of musical instruments within the greater category of wind instruments. Common examples include flute, clarinet, oboe, bassoon, and saxophone. There are two main types of woodwind instruments: flutes and ...
repair, a smoke test involved plugging one end of an instrument and blowing tobacco smoke from the tester's mouth into the other to test for leaks. Escaping smoke revealed improperly seated pads and faulty joints (i.e. leaks). After this test the instrument was cleaned to remove nicotine and other deposits left by the smoke.Anthony Baines, Woodwind Instruments and their history", 1967 (page 355) Described in a repair manual written in the 1930s, smoke testing is considered obsolete, and is no longer used by reputable technicians. The usual alternative to smoke is to place a bright light inside the instrument then check for light appearing around pads and joints.


Automotive repair

In the same way that plumbing and woodwind instruments are tested, the
vacuum A vacuum is a space devoid of matter. The word is derived from the Latin adjective ''vacuus'' for "vacant" or " void". An approximation to such vacuum is a region with a gaseous pressure much less than atmospheric pressure. Physicists often di ...
systems of automobiles may be tested in order to locate difficult-to-find vacuum leaks. Artificial smoke is deliberately introduced into the system under slight pressure and any leaks are indicated by the escaping smoke. Smoke can also be used to locate difficult-to-find leaks in the fuel evaporative emissions control (
EVAP Vehicle emissions control is the study of reducing the emissions produced by motor vehicles, especially internal combustion engines. Types of emissions Emissions of many air pollutants have been shown to have variety of negative effects on public ...
) system.


Infectious disease control

In
infectious disease An infection is the invasion of tissues by pathogens, their multiplication, and the reaction of host tissues to the infectious agent and the toxins they produce. An infectious disease, also known as a transmissible disease or communicable d ...
control a smoke test is done to see whether a room is under
negative pressure Negative pressure may refer to: * Negative value of a pressure variable * Negative room pressure, a ventilation technique used to avoid contaminating outside areas * Negative pressure ventilator A negative pressure ventilator (NPV) is a type of m ...
. A tube containing smoke is held near the bottom of the negative pressure room door, about two inches in front of the door. The smoke tube is held parallel to the door, and a small amount of smoke is then generated by gently squeezing the bulb. Care is taken to release the smoke from the tube slowly to ensure the velocity of the smoke from the tube does not overpower the air velocity. If the room is at negative pressure, the smoke will travel under the door and into the room. If the room is not at negative pressure, the smoke will be blown outward or will stay stationary.


References

{{DEFAULTSORT:Smoke testing Tests Smoke