The
respiratory protective devices (RPD) can protect workers only if their protective properties are adequate to the conditions in the
workplace
A workplace is a location where someone works, for their employer or themselves, a place of employment. Such a place can range from a home office to a large office building or factory. For industrialized societies, the workplace is one of the ...
. Therefore, specialists have developed criteria for the selection of proper, adequate respirators, including the Assigned Protection Factors (APF) - the decrease of the concentration of harmful substances in the inhaled air, which (is expected) to be provided with timely and proper use of a certified respirator of certain types (''design'') by taught and trained
workers (after individual selection with a tight-fitting mask and
fit testing), when the
employer
Employment is a relationship between two parties regulating the provision of paid labour services. Usually based on a contract, one party, the employer, which might be a corporation, a not-for-profit organization, a co-operative, or any ot ...
performs an effective respiratory protective device programme.
Background
The different methods of protection from air pollution and their effectiveness
The imperfection of
technological processes,
machines
A machine is a physical system that uses power to apply forces and control movement to perform an action. The term is commonly applied to artificial devices, such as those employing engines or motors, but also to natural biological macromolec ...
and other equipment can lead to air contamination with harmful substances in the
workplace
A workplace is a location where someone works, for their employer or themselves, a place of employment. Such a place can range from a home office to a large office building or factory. For industrialized societies, the workplace is one of the ...
. Protecting of the workers' health in this situation may be achieved by different means, listed below in order of decreasing of their effectiveness:
If the use of these methods is impossible, or if their use did not reduce the concentration of harmful substances to
a safe value, workers must use respirators. These respirators must be sufficiently effective, and they should correspond to known or expected conditions at the workplace. However, the sole reliance on personal protective equipment for personnel is considered the least
effective means of controlling hazards, for reasons including: non-usage of the respirators in the contaminated atmosphere; leakage of unfiltered air through the gaps between the mask and face; and
delayed replacement of gas cartridges.
The effectiveness of respirators with different designs
Different terms may be used to describe the protective properties of respirators:
* Penetration = (the concentration of harmful substances under mask) / (concentration outside the mask);
* Efficiency =
( (concentration outside the mask) - (the concentration of harmful substances under mask)
) / (concentration outside the mask) = 1 - Penetration;
* Protection Factor (PF) = (the concentration of harmful substances on the outside of the mask) / (concentration under mask) = 1 / Penetration.
The term "Protection Factor PF" has been used in the U.S., and the term "Penetration" was used in the soviet literature from the 1960s.
In the first half of the 20th century, experts measured protective properties of respirators in the laboratories. They used different control substances (
argon
Argon is a chemical element; it has symbol Ar and atomic number 18. It is in group 18 of the periodic table and is a noble gas. Argon is the third most abundant gas in Earth's atmosphere, at 0.934% (9340 ppmv). It is more than twice as abu ...
,
halogenated hydrocarbon vapour,
aerosol
An aerosol is a suspension (chemistry), suspension of fine solid particles or liquid Drop (liquid), droplets in air or another gas. Aerosols can be generated from natural or Human impact on the environment, human causes. The term ''aerosol'' co ...
s of
sodium chloride
Sodium chloride , commonly known as Salt#Edible salt, edible salt, is an ionic compound with the chemical formula NaCl, representing a 1:1 ratio of sodium and chloride ions. It is transparent or translucent, brittle, hygroscopic, and occurs a ...
and oil mist,
fluorophore
A fluorophore (or fluorochrome, similarly to a chromophore) is a fluorescent chemical compound that can re-emit light upon light excitation. Fluorophores typically contain several combined aromatic groups, or planar or cyclic molecules with se ...
s,
dioctyl phthalate
Bis(2-ethylhexyl) phthalate, di-2-ethylhexyl phthalate, diethylhexyl phthalate, diisooctyl phthalate, DEHP; incorrectly — dioctyl phthalate, DIOP) is an organic compound with the formula C6H4(CO2C8H17)2. DEHP is the most common member of the cl ...
,
and others, and they measured their concentrations under the mask, and outside masks (simultaneously). The ratio of the measured concentrations is an indicator of the protective properties of different types of respirators. These measurements showed that if the efficiency of
filters
Filtration is a physical process that separates solid matter and fluid from a mixture.
Filter, filtering, filters or filtration may also refer to:
Science and technology
Computing
* Filter (higher-order function), in functional programming
* Fil ...
is sufficiently high, then the gaps between the mask and the face become the main way of penetration of air contamination under the mask, in the same way that on a cold day, a person wearing a warm jacket and pants will lose most of their heat through the head and extremities.
The shape and size of these gaps is not constant, and depends on many factors (the degree of fit the mask to the face - by shape and size; the correct donning the mask; the mask slippage on the face during the work due to execution of different movements; the design of the mask). The respirator's PF may change dozens of times over several minutes; and the two average PF (''that were measured for the same worker in one day; for example - before and after the lunch break'') can differ by more than 12 000 times.
Experts believed that the measurement of protection factors in the laboratory allows them to correctly evaluate, predict the RPD efficiency in the workplace conditions. But after the detection of cases of excessive harmful exposure on employees who used high quality respirators with
HEPA
HEPA (, high efficiency particulate air) filter, also known as a high efficiency particulate arresting filter, is an efficiency standard of air filters.
Filters meeting the HEPA standard must satisfy certain levels of efficiency. Common standa ...
particle filters in the
nuclear industry
Nuclear power is the use of nuclear reactions to produce electricity. Nuclear power can be obtained from nuclear fission, nuclear decay and nuclear fusion reactions. Presently, the vast majority of electricity from nuclear power is produced by ...
of the US, the experts changed their opinion.
Studies have been carried out to measure the protection factors for the various types of respirators - not only in the laboratories, but also at the workplaces.
Dozens of such field studies have shown that the performance of serviceable respiratory protective equipment at the workplaces may be significantly less than in laboratory conditions. Therefore, the usage of laboratory results to assess the real efficiency is incorrect; and can lead to a wrong choice of such respirators that can not reliably protect workers.
Terminology to describe the different PF, and methods for APF development
The experts used the results of measurements at the laboratories and
at the workplaces to develop more completely terminology for description of the respirators' performance;
and this terminology has been applied officially,
and in the preparation of research results for publication.
Specialists began to use different terms to describe the protection factors, which were measured at workplaces with continuous use of respirators; and measured in the workplace when the workers used of respirators intermittently; measured not in the workplace while
fit testing; measured in the laboratories under the simulation workplace's conditions; and for the protection factors, that can be expected (''in most cases'') when the workers properly used the respirators at the workplace.
A significant difference between respirator performance in the laboratories compared to
the efficiency at the workplaces not allowed to use the laboratory results to predict the degree of protection offered in practice. And instability of respirators' protective properties (for the same RPD design, and in the same usage conditions) prevented evaluate their efficiency. For solving these problems, scientists Donald Campbell and Steven Lenhart suggested to use the results of measurements of Workplace PF values for development of Assigned (''expected in practice'') PF values (APF) - as the lower
95% confidence interval of WPF values.
The results of measurements of WPF has been used in the development of APF by
ANSI
The American National Standards Institute (ANSI ) is a private nonprofit organization that oversees the development of voluntary consensus standards for products, services, processes, systems, and personnel in the United States. The organiz ...
(for the recommended standard, that is not mandatory).
The same was made during the development of the APF
by
OSHA
The Occupational Safety and Health Administration (OSHA; ) is a regulatory agency of the United States Department of Labor that originally had federal visitorial powers to inspect and examine workplaces. The United States Congress established ...
(in the development of the standard,
that is mandatory for the employer).
Development of APF values for the various respirator types
Results of measurements of WPF in the US and the UK became the basis for the development of APF for UK standard
and for English version of EU standard.
In some cases, there was no information on the effectiveness for respirators of specific design (type) in the workplace. This is due to the fact that the measurement of workplace PF is very difficult, time-consuming, and expensive work, which was carried out not very often. For these types of respirators experts used the results of WPF measurements of other types of respirators, which are similar. For example, the effectiveness of the Supplied Air Respirators (SARs, with hose) was considered similar to the efficiency of
Powered Air Purifying Respirators (PAPRs), if they have the same facepieces and the same air supply mode. Finally, in the absence of this information, specialists could use the results of Simulated WPF measurements; or estimates of competent experts.
Correction of Assigned PF values
Measurement of workplace protection factors surprisingly revealed the low efficiency of some designs of respirators, and that results have led to a sharp tightening of the requirements for application limits for respirators of such designs.
* PAPR with helmets or hoods
In a 1984 study by Myers et al., the WPF measurements for
Powered Air Purifying Respirators (PAPRs) with helmets (that is not tight-fitted to the face) showed that the ingress of harmful substances in the inhaled air can be very high
(PF = 28 and 42 for two models). This came as a surprise, since earlier studies in the laboratory showed that the flow of clean filtered air from the inside to the outside of the helmet prevents ingress of harmful substances under the helmet (PF > 1000). Additional studies,
from 1986 and 1981, agreed with the result from the Myers et al. 1986 study: the minimum values of the workplace protection factors of two models of respirators were 31 and 23; and leakage of unfiltered air attained 16% in some cases in
wind tunnel
A wind tunnel is "an apparatus for producing a controlled stream of air for conducting aerodynamic experiments". The experiment is conducted in the test section of the wind tunnel and a complete tunnel configuration includes air ducting to and f ...
at 2 m/s air velocity
Therefore, the use of such RPD types was limited 25 PEL in the United States,
and 40
OEL in the UK.

* Negative pressure full face masks
Measurement of protection factors of negative pressure full face masks with high-efficiency filters in the laboratory revealed a risk of decrease in protective properties to a small values.
Therefore, the use of such respirators has been limited to the values 50 or 100 PEL in the United States. However, the experts in the UK believed that the quality of their masks is higher than American masks, and were allowed to use up to 900 OEL. But the study
showed that the value of the protection factor of > 900 has been achieved in practice infrequently. Minimum protection factors of 3 different models of full facepiece respirators were 11, 18 and 26. So, the new standards
limit usage of these respirators up to 40 OEL in UK (after this study).
* Negative pressure half mask respirators (after fit testing)
Fit testing of tight-fitting masks of negative-pressure respirators became widely used in US industry in 1980-s. At the beginning, it was thought that the half-mask fit quite well to the worker's face, if during a fit test the protection factor (fit factor) is not less than 10 (later, experts began to use
"safety factor" = 10 during the fit test; threshold fit factor become 10 × 10 = 100). The widespread use of fit testing in the industry gives professionals optimism, and they allowed to the employers restrict the use of half mask respirators in accordance with the values of worker's personal fit factor (the maximum concentration of pollutants = personal Fit Factor × PEL), but not more than 100 × PEL. However, scientific studies have shown that although such test increases the effectiveness of protection, the risk of leakage of large amounts of unfiltered air is maintained. Furthermore, the studies have shown that non-filtered air under the mask is not uniformly mixed with the filtered air, which leads to large errors in the measurement of the in-facepiece concentration of contaminants, and subsequent calculations of fit factors - the latter is often much smaller than the "measured" value. So, specialists recommend not allowed usage negative pressure half mask respirators then harmful substances' concentrations exceeds 10 PEL.
Therefore, OSHA standards require to restrict using of half-mask negative-pressure respirators up to 10 PEL after obtaining fit factor greater than or equal to 100 during the mask selection for the worker (they used a
safety factor
In engineering, a factor of safety (FoS) or safety factor (SF) expresses how much stronger a system is than it needs to be for its specified maximum load. Safety factors are often calculated using detailed analysis because comprehensive testing i ...
= 10).
US Assigned PF values
Air-purifying respirators cannot be used in
oxygen-deficient atmosphere
Inert gas asphyxiation is a form of asphyxiation which results from breathing a physiologically inert gas in the absence of oxygen, or a low amount of oxygen (hypoxia), rather than atmospheric air (which is composed largely of nitrogen and oxygen ...
s (less than 19.5% oxygen). Nor can they be used in atmospheres with a contaminant concentration that may be
immediately dangerous to life or health
The term immediately dangerous to life or health (IDLH) is defined by the US National Institute for Occupational Safety and Health (NIOSH) as exposure to airborne contaminants that is "likely to cause death or immediate or delayed permanent adver ...
, or in unknown atmospheres. In these cases
air-supplying respirators must be used. If concentrations of hazardous particulates or gasses that are greater than the
occupational exposure limit
An occupational exposure limit is an upper limit on the acceptable concentration of a hazardous substance in workplace air for a particular material or class of materials. It is typically set by competent national authorities and enforced by legi ...
, U.S. regulations require that respirators be worn, but they may also be worn at lower concentrations.
Similar mandatory legal requirements apply to employers in many other countries (examples
). The respirator must have a sufficient assigned protection factor (APF) for the conditions.
[ For download on ]Wikimedia Commons
Wikimedia Commons, or simply Commons, is a wiki-based Digital library, media repository of Open content, free-to-use images, sounds, videos and other media. It is a project of the Wikimedia Foundation.
Files from Wikimedia Commons can be used ...
: PDF fulltext
Elastomeric masks may fail to protect if they are not donned before entering a hazardous environment. Other problems include using a size other than the size the wearer was fit-tested on, using the wrong sort of cartridge, re-using a cartridge that is no longer good, not doing a positive- and negative-pressure seal check each time the mask is donned, failing to test the respirator (and perhaps inhaling the carbon from a broken cartridge), and even putting the nose-clip up the nose rather than using it to pinch the nose shut.
Comparison of APF in the US and the UK
The table lists the APF values for the most common respirator types (for US and UK).
US particle filters N95 are similar to P2; and P100 (
HEPA
HEPA (, high efficiency particulate air) filter, also known as a high efficiency particulate arresting filter, is an efficiency standard of air filters.
Filters meeting the HEPA standard must satisfy certain levels of efficiency. Common standa ...
) are similar to P3; filtering materials in US N95 filtering facepieces are similar to FFP2. However, in the UK and Europe any tight fitting half mask/full face mask is required to have a second check based on total inward leakage (TIL) which cannot exceed 8% for FFP2 and 2% for FFP3
The difference of the APF for air purifying negative pressure full-facepiece masks are not large. The difference between PAPR with helmets a few more. But measurements showed that the
real effectiveness of RPD (at the workplace conditions) is strongly dependent on the conditions of their use, not only from the design, and this partly explains the difference in APF values. The APF for negative pressure half mask respirators are twofold. But this difference cannot be considered separately from recommendations for use of respirators. The use of half-face masks in the US is limited to 10 PEL for the "worst case" - work in the polluted atmosphere of 8 hours per day, 40 hours a week. But British experts took into account large experience of the use of negative pressure air purifying RPDs, and they concluded that to achieve continuous wear respirator 8 hours a day is impossible (because of the negative impact on the health of workers). For this reason, they recommend to the employer to give the job to the workers so that they work in the polluted atmosphere not during entire shift, but only a part of the shift. The remaining time the employee needs to work in a non-polluted atmosphere (without the respirator). The fact that the employee is in a non-polluted atmosphere some part of working time provide additional protection of his health, and therefore, the requirements to the efficiency of the respirator may be less stringent.
The development of the Assigned PF in the United States and Britain were based on measurements of the effectiveness of respirators in the workplace (after statistical processing). Also used opinions of experts, based on the similarity of the respirators with different designs (for example, powered air purifying filtering respirators (PAPR), and a similar supplied air respirators SAR) - provided that the mode and the quantity of air supply, and the facepieces (masks) were the same. Experts in the two countries often used the results of the same studies of WPF (because of their limited number). For example, British standard
had been developed with usage of results of 1897 WPF measurements during 31 studies; and 23 of this 31 studies had been conducted in United States.
Therefore, the values of the assigned PF in the US and in the UK are evidence-based; and they are very similar to each other.
The values of the APF in EU and other countries
Studies of respirator's performance was carried out not very often, and almost all of these studies were conducted in USA (and UK). It is possible that the lack of information about the RPD efficiency in the workplaces, was the reason behind developing these assigned PF in several European countries, whose values differ significantly from the evidence-based values of APFs in the US and UK.
Most European countries (except UK) did not conduct very complex and expensive studies on the effectiveness of respirators in the workplaces, or spent very little of such research. Therefore, it may be that some countries do not take full account of results of foreign researches (that showed a significant difference between the effectiveness of respirators in a laboratory environment; and in applying them in the workplaces). For example, after the study
in 1990, the APF value of negative pressure full face masks was reduced from 900 to 40 (1997)
in UK. But in other countries, similar research was not carried out; and a similar decrease did not occur.
The study
showed that the three models of full face masks had a significant leakage of unfiltered air through the gaps between the mask and the face. The minimum values of the workplace protection factors (WPF) of each of the three negative pressure full face mask models were 11, 17 and 26. The maximum value of the WPF from one of the models did not exceed 500 no times at all. And for all results together, the WPF was not more than 100 in ~ 30% of the measurements. So, for this reason, the values of the APFs for this RPD type in Germany (400), Finland (500), Italy (400), and Sweden (500), may not fully take into account the lower this type respirators' performance at the workplace compared to the performance in the laboratory (during certification). The same was true for other RPD types and their APF.
State standard in
India
India, officially the Republic of India, is a country in South Asia. It is the List of countries and dependencies by area, seventh-largest country by area; the List of countries by population (United Nations), most populous country since ...
points to the need to use the workplace protection factors for restricting the permissible use of respirators, but does not set any values of the APFs. The standard also recommends the use of those PFs, which are obtained during the certification (in the laboratories, but not at workplaces). These values greatly exceed the values used in the US and in the UK.
The
Ukrainian version of the EU standard EN 529 does not set any values of the APFs for the selection of respirator in this country.
This document only listed the values of APFs in several European countries (for reference); and declares the inadmissibility of the use of laboratory efficiency for predicting the protective properties at the workplace.
The APFs are not developed in
RF,
in
South Korea
South Korea, officially the Republic of Korea (ROK), is a country in East Asia. It constitutes the southern half of the Korea, Korean Peninsula and borders North Korea along the Korean Demilitarized Zone, with the Yellow Sea to the west and t ...
, as well as in many other countries, and selection of respirators is not regulated by its national legislation. This contributes to errors, and the usage of such respirator's types, which are not able to reliably protect the workers due to its design (even at high quality of specific certified models).
The use of the APFs when selecting respirators for known workplace conditions
US law obliges the employer to accurately
measure air pollution at workplaces. The results of such measurements are used to assess whether short-term inhalation of harmful substances may lead to irreversible and significant deterioration of health, or death (
IDLH concentrations). If concentrations exceed the IDLH, the standard allows the use of only the most reliable respirators - SAR or self-contained breathing apparatus: with pressure-demand air supply in the full facepiece mask ( §(d)(2)
).
If the concentration of a harmful substance is less than the IDLH, the coefficient of air pollution for the harmful substance (Hazard Factor) is determined, which is equal to the ratio of this concentration to the PEL (TLV, OEL) for the harmful substance. The APF of the selected respirator type must equal or exceed the Hazard Factor.
If there are several harmful substances in the workplace air, then the selected respirator must meet the following requirement:
C
1/(APF×PEL
1) + C
2/(APF×PEL
2 ) + C
3/(APF×PEL
3 ) + ... + Cn/(APF×PELn) ≤ 1
where C
1, C
2 ... and Cn are the concentrations of harmful substances number 1, 2 ... n; and
PEL is the maximum allowable concentration for corresponding harmful substances in the breathing zone.
If this requirement is not met, the employer needs to choose a different type of respirator, which has a greater APF value.
In all cases, if they employer selects a respirator with tight-fitting facepiece (full face mask, elastomeric half-mask or quarter-mask, or filtering facepiece respirator), all employee must be
fit tested (''to prevent the leakage of unfiltered polluted air through gaps between their faces and the tight-fitting masks, which may not match to their faces''). Appendix A
provides a detailed description of this testing.
Values of IDLH concentrations and detailed recommendations for the selection of respirators (and self-rescuers) are available in the NIOSH directory.
International standard for RPD selection and usage
ISO
The International Organization for Standardization (ISO ; ; ) is an independent, non-governmental, international standard development organization composed of representatives from the national standards organizations of member countries.
Me ...
is developing two international standards that govern the certification of respirators;
and their selection and application
The standards governing the selection of respirators use the APF value. But
HSE specialists critique these documents,
noting these standards are set to values of APF that differ from those established in the US and the UK; and these values are set not for a specific RPD type but rather for any RPD that meets approval requirements:
The report concluded that new ISO standards set insufficiently high APF values and recommended that these values should not be used in practice, and to continue work on APF justification for the different types of respirators.
See also
*
Immediately dangerous to life or health
The term immediately dangerous to life or health (IDLH) is defined by the US National Institute for Occupational Safety and Health (NIOSH) as exposure to airborne contaminants that is "likely to cause death or immediate or delayed permanent adver ...
*
Permissible exposure limit
The permissible exposure limit (PEL or OSHA PEL) is a legal limit in the United States for exposure of an employee to a chemical substance or physical agents such as high level noise. Permissible exposure limits were established by the Occupational ...
*
Respirators testing in the workplaces
References
Further reading
{{Commons-inline, list=
*
A Performance Evaluation of DM and DFM Filter Respirators Certified for Protection Against Toxic Dusts, Fumes, and Mists WORKING DRAFT
*
Statistical Methods for the Determination of Noncompliance with Occupational Health Standards
Respirators