The roentgen equivalent man (rem)
is a
CGS unit of
equivalent dose,
effective dose, and
committed dose, which are dose measures used to estimate potential health effects of low levels of
ionizing radiation on the human body.
Quantities measured in rem are designed to represent the
stochastic
Stochastic (, ) refers to the property of being well described by a random probability distribution. Although stochasticity and randomness are distinct in that the former refers to a modeling approach and the latter refers to phenomena themselve ...
biological risk of ionizing radiation, which is primarily
radiation-induced cancer
Exposure to ionizing radiation is known to increase the future incidence of cancer, particularly leukemia. The mechanism by which this occurs is well understood, but quantitative models predicting the level of risk remain controversial. The most w ...
. These quantities are derived from
absorbed dose
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmf ...
, which in the CGS system has the unit
rad
RAD or Rad may refer to:
People
* Robert Anthony Rad Dougall (born 1951), South African former racing driver
* Rad Hourani, Canadian fashion designer and artist
* Nickname of Leonardus Rad Kortenhorst (1886–1963), Dutch politician
* Radley ...
. There is no universally applicable conversion constant from rad to rem; the conversion depends on
relative biological effectiveness
In radiobiology, the relative biological effectiveness (often abbreviated as RBE) is the ratio of biological effectiveness of one type of ionizing radiation relative to another, given the same amount of absorbed energy. The RBE is an empiric ...
(RBE).
The rem has been defined since 1976 as equal to 0.01
sievert, which is the more commonly used
SI unit
The International System of Units, known by the international abbreviation SI in all languages and sometimes Pleonasm#Acronyms and initialisms, pleonastically as the SI system, is the modern form of the metric system and the world's most wid ...
outside the United States. Earlier definitions going back to 1945 were derived from the
roentgen unit, which was named after
Wilhelm Röntgen
Wilhelm Conrad Röntgen (; ; 27 March 184510 February 1923) was a German mechanical engineer and physicist, who, on 8 November 1895, produced and detected electromagnetic radiation in a wavelength range known as X-rays or Röntgen rays, an achie ...
, a German scientist who discovered
X-ray
X-rays (or rarely, ''X-radiation'') are a form of high-energy electromagnetic radiation. In many languages, it is referred to as Röntgen radiation, after the German scientist Wilhelm Conrad Röntgen, who discovered it in 1895 and named it ' ...
s. The unit name is misleading, since 1 roentgen actually deposits about 0.96 rem in soft biological tissue, when all weighting factors equal unity. Older units of rem following other definitions are up to 17% smaller than the modern rem.
Doses greater than 100 rem received over a short time period are likely to cause
acute radiation syndrome (ARS), possibly leading to death within weeks if left untreated. Note that the quantities that are measured in rem were not designed to be correlated to ARS symptoms. The
absorbed dose
Absorbed dose is a dose quantity which is the measure of the energy deposited in matter by ionizing radiation per unit mass. Absorbed dose is used in the calculation of dose uptake in living tissue in both radiation protection (reduction of harmf ...
, measured in rad, is a better indicator of ARS.
[''The Effects of Nuclear Weapons'', Revised ed., US DOD 1962]
A rem is a large dose of radiation, so the millirem (mrem), which is one thousandth of a rem, is often used for the dosages commonly encountered, such as the amount of radiation received from medical x-rays and
background sources.
Usage
The rem and millirem are CGS units in widest use among the U.S. public, industry, and government.
However, the SI unit the
sievert (Sv) is the normal unit outside the United States, and is increasingly encountered within the US in academic, scientific, and engineering environments.
The conventional units for dose rate is mrem/h. Regulatory limits and chronic doses are often given in units of mrem/yr or rem/yr, where they are understood to represent the total amount of radiation allowed (or received) over the entire year. In many occupational scenarios, the hourly dose rate might fluctuate to levels thousands of times higher for a brief period of time, without infringing on the annual total exposure limits. There is no exact conversion from hours to years because of leap years, but approximate conversions are:
:1 mrem/h = 8,766 mrem/yr
:0.1141 mrem/h = 1,000 mrem/yr
The
International Commission on Radiological Protection (ICRP) once adopted fixed conversion for occupational exposure, although these have not appeared in recent documents:
:8 h = 1 day
:40 h = 1 week
:50 week = 1 yr
Therefore, for occupation exposures of that time period,
:1 mrem/h = 2,000 mrem/yr
:0.5 mrem/h = 1,000 mrem/yr
The U.S.
National Institute of Standards and Technology
The National Institute of Standards and Technology (NIST) is an agency of the United States Department of Commerce whose mission is to promote American innovation and industrial competitiveness. NIST's activities are organized into Outline of p ...
(NIST) strongly discourages Americans from expressing doses in rem, in favor of recommending the SI unit.
The NIST recommends defining the rem in relation to the SI in every document where this unit is used.
Health effects
Ionizing radiation has deterministic and stochastic effects on human health. The deterministic effects that can lead to
acute radiation syndrome only occur in the case of high doses (> ~10 rad or > 0.1 Gy) and high dose rates (> ~10 rad/h or > 0.1 Gy/h). A model of deterministic risk would require different weighting factors (not yet established) than are used in the calculation of equivalent and effective dose. To avoid confusion, deterministic effects are normally compared to absorbed dose in units of rad, not rem.
Stochastic effects are those that occur randomly, such as
radiation-induced cancer
Exposure to ionizing radiation is known to increase the future incidence of cancer, particularly leukemia. The mechanism by which this occurs is well understood, but quantitative models predicting the level of risk remain controversial. The most w ...
. The consensus of the nuclear industry, nuclear regulators, and governments, is that the incidence of cancers caused by ionizing radiation can be modeled as increasing linearly with effective dose at a rate of 0.055% per rem (5.5%/Sv).
Individual studies, alternate models, and earlier versions of the industry consensus have produced other risk estimates scattered around this consensus model. There is general agreement that the risk is much higher for infants and fetuses than adults, higher for the middle-aged than for seniors, and higher for women than for men, though there is no quantitative consensus about this.
There is much less data, and much more controversy, regarding the possibility of
cardiac
The heart is a muscular organ found in most animals. This organ pumps blood through the blood vessels of the circulatory system. The pumped blood carries oxygen and nutrients to the body, while carrying metabolic waste such as carbon di ...
and
teratogenic
Teratology is the study of abnormalities of physiological development in organisms during their life span. It is a sub-discipline in medical genetics which focuses on the classification of congenital abnormalities in dysmorphology. The relat ...
effects, and the modelling of
internal dose.
The ICRP recommends limiting artificial irradiation of the public to an average of 100 mrem (1 mSv) of effective dose per year, not including medical and occupational exposures.
For comparison, radiation levels inside the
United States Capitol
The United States Capitol, often called The Capitol or the Capitol Building, is the Seat of government, seat of the Legislature, legislative branch of the Federal government of the United States, United States federal government, which is form ...
are 85 mrem/yr (0.85 mSv/yr), close to the regulatory limit, because of the uranium content of the granite structure.
History
The concept of the rem first appeared in literature in 1945 and was given its first definition in 1947. The definition was refined in 1950 as "that dose of any ionizing radiation which produces a relevant biological effect equal to that produced by one
roentgen of high-voltage x-radiation." Using data available at the time, the rem was variously evaluated as 83, 93, or 95
erg/gram. Along with the introduction of the rad in 1953, the ICRP decided to continue the use of the rem. The US
National Committee on Radiation Protection and Measurements
National may refer to:
Common uses
* Nation or country
** Nationality – a ''national'' is a person who is subject to a nation, regardless of whether the person has full rights as a citizen
Places in the United States
* National, Maryland, c ...
noted in 1954 that this effectively implied an increase in the magnitude of the rem to match the rad (100 erg/gram). The ICRP officially adopted the rem as the unit of equivalent dose in 1962 to measure the way different types of radiation distribute energy in tissue and began recommending values of
relative biological effectiveness
In radiobiology, the relative biological effectiveness (often abbreviated as RBE) is the ratio of biological effectiveness of one type of ionizing radiation relative to another, given the same amount of absorbed energy. The RBE is an empiric ...
(RBE) for various types of radiation. In practice, the unit of rem was used to denote that an RBE factor had been applied to a number which was originally in units of rad or roentgen.
The
International Committee for Weights and Measures
The General Conference on Weights and Measures (GCWM; french: Conférence générale des poids et mesures, CGPM) is the supreme authority of the International Bureau of Weights and Measures (BIPM), the intergovernmental organization established ...
(CIPM) adopted the sievert in 1980 but never accepted the use of the rem. The NIST recognizes that this unit is outside the SI but temporarily accepts its use in the U.S. with the SI.
The rem remains in widespread use as an industry standard in the U.S. The United States
Nuclear Regulatory Commission
The Nuclear Regulatory Commission (NRC) is an independent agency of the United States government tasked with protecting public health and safety related to nuclear energy. Established by the Energy Reorganization Act of 1974, the NRC began oper ...
still permits the use of the units
curie, rad, and
rem
Rem or REM may refer to:
Music
* R.E.M., an American rock band
* ''R.E.M.'' (EP), by Green
* "R.E.M." (song), by Ariana Grande
Organizations
* La République En Marche!, a French centrist political party
* Reichserziehungsministerium, in Nazi G ...
alongside SI units.
Radiation-related quantities
The following table shows radiation quantities in SI and non-SI units:
See also
*
Roentgen equivalent physical
*
Banana equivalent dose
Banana equivalent dose (BED) is an informal unit of measurement of ionizing radiation exposure, intended as a general educational example to compare a dose of radioactivity to the dose one is exposed to by eating one average-sized banana. Banan ...
*
Health threat from cosmic rays
*
Orders of magnitude (radiation)
Recognized effects of higher acute radiation doses are described in more detail in the article on radiation poisoning. Although the International System of Units (SI) defines the sievert (Sv) as the unit of radiation dose equivalent, chronic rad ...
References
{{DEFAULTSORT:Roentgen Equivalent Man
Units of radiation dose
Radiation health effects
Radiobiology
Non-SI metric units
Equivalent
Equivalent units