Plethysmograph
   HOME

TheInfoList



OR:

A plethysmograph is an instrument for measuring changes in volume within an
organ Organ and organs may refer to: Biology * Organ (biology), a group of tissues organized to serve a common function * Organ system, a collection of organs that function together to carry out specific functions within the body. Musical instruments ...
or whole body (usually resulting from fluctuations in the amount of blood or air it contains). The word is derived from the Greek "plethysmos" (increasing, enlarging, becoming full), and "graphein" (to write).


Organs studied


Lungs

Pulmonary plethysmographs are commonly used to measure the
functional residual capacity Functional residual capacity (FRC) is the lung volume, volume of air present in the lungs at the end of passive Exhalation, expiration.Hopkins E, Sharma S. Physiology, Functional Residual Capacity. pdated 2022 Jan 4 In: StatPearls nternet...
(FRC) of the
lung The lungs are the primary Organ (biology), organs of the respiratory system in many animals, including humans. In mammals and most other tetrapods, two lungs are located near the Vertebral column, backbone on either side of the heart. Their ...
s—the volume in the lungs when the muscles of respiration are relaxed—and total lung capacity. In a traditional plethysmograph (or "body box"), the test subject, or patient, is placed inside a sealed chamber the size of a small telephone booth with a single mouthpiece. At the end of normal expiration, the mouthpiece is closed. The patient is then asked to make an inspiratory effort. As the patient tries to inhale (a maneuver which looks and feels like panting), the lungs expand, decreasing pressure within the lungs and increasing lung volume. This, in turn, increases the pressure within the box since it is a closed system and the volume of the box compartment has decreased to accommodate the new volume of the subject. With cabinless plethysmography, the patient is seated next to a desktop testing device and inserts the mouthpiece into their mouth. The patient takes a series of normal tidal breaths for approximately one minute. During this tidal breathing, a series of rapid interruptions occurs, with a shutter opening and closing, measuring pressure and volume. Lung volume measurements taken with cabinless plethysmography are considered equivalent to body plethysmography.


Methodological approach

Boyle's law Boyle's law, also referred to as the Boyle–Mariotte law or Mariotte's law (especially in France), is an empirical gas laws, gas law that describes the relationship between pressure and volume of a confined gas. Boyle's law has been stated as: ...
is used to calculate the unknown volume within the lungs. First, the change in volume of the chest is computed. The initial pressure of the box times its volume is considered equal to the known pressure after expansion times the unknown new volume. Once the new volume is found, the original volume minus the new volume is the change in volume in the box and also the change in volume in the chest. With this information, Boyle's law is used again to determine the original volume of gas in the chest: the initial volume (unknown) times the initial pressure is equal to the final volume times the final pressure. Starting from this principle, it can be shown that the functional residual capacity is a function of the changes in volume and pressures as follows: FRC = K_V \frac , K_V \approx P_ The difference between full and empty lungs can be used to assess diseases and airway passage restrictions. An obstructive disease will show increased FRC because some airways do not empty normally, while a restrictive disease will show decreased FRC. Body plethysmography is particularly appropriate for patients who have air spaces which do not communicate with the bronchial tree; in such patients helium dilution would give an incorrectly low reading. Another important parameter, which can be calculated with a body plethysmograph is the airway resistance. During inhalation the chest expands, which increases the pressure within the box. While observing the so-called resistance loop (cabin pressure and flow), diseases can easily be recognized. If the resistance loop becomes planar, this shows a bad compliance of the lung. A
COPD Chronic obstructive pulmonary disease (COPD) is a type of progressive lung disease characterized by chronic respiratory symptoms and airflow limitation. GOLD defines COPD as a heterogeneous lung condition characterized by chronic respiratory s ...
, for instance, can easily be discovered because of the unique shape of the corresponding resistance loop.


Limbs

Some plethysmograph devices are attached to arms,
leg A leg is a weight-bearing and locomotive anatomical structure, usually having a columnar shape. During locomotion, legs function as "extensible struts". The combination of movements at all joints can be modeled as a single, linear element cap ...
s or other extremities and used to determine circulatory capacity. In water plethysmography an extremity, e.g. an arm, is enclosed in a water-filled chamber where volume changes can be detected. Air plethysmography uses a similar principle but based on an air-filled long cuff, which is more convenient but less accurate. Another practical device is mercury-filled strain gauges used to continuously measure circumference of the extremity, e.g. at mid calf. Impedance plethysmography is a non-invasive method used to detect
venous thrombosis Venous thrombosis is the blockage of a vein caused by a thrombus (blood clot). A common form of venous thrombosis is deep vein thrombosis (DVT), when a blood clot forms in the deep veins. If a thrombus breaks off ( embolizes) and flows to the lu ...
in these areas of the body.


Genitals

Another common type of plethysmograph is the penile plethysmograph. This device is used to measure changes in blood flow in the
penis A penis (; : penises or penes) is a sex organ through which male and hermaphrodite animals expel semen during copulation (zoology), copulation, and through which male placental mammals and marsupials also Urination, urinate. The term ''pen ...
. Although some researchers use this device to assess
sexual arousal Sexual arousal (also known as sexual excitement) describes the Physiology, physiological and psychological responses in preparation for sexual intercourse or when exposed to Sexual stimulation, sexual stimuli. A number of physiological response ...
and
sexual orientation Sexual orientation is an enduring personal pattern of romantic attraction or sexual attraction (or a combination of these) to persons of the opposite sex or gender, the same sex or gender, or to both sexes or more than one gender. Patterns ar ...
, courts that have considered penile plethysmography generally rule that the technique is not sufficiently reliable for use in court.Myers JEB (2005). ''Myers on Evidence in Child, Domestic, and Elder Abuse Cases.'' Aspen Publishers Online An approximate female equivalent to penile plethysmography is vaginal photoplethysmography, which optically measures blood flow in the vagina.


Use in preclinical research

Plethysmography is a widely used method in basic and
preclinical research In drug development, preclinical development (also termed preclinical studies or nonclinical studies) is a stage of research that begins before clinical trials (testing in humans) and during which important feasibility, iterative testing and dr ...
to study respiration. Several techniques are used:


Respiratory parameters from conscious freely moving animals: whole-body plethysmography

Whole-body plethysmography is used to measure respiratory parameters in conscious unrestrained subjects, including quantification of
bronchoconstriction Bronchoconstriction is the constriction of the airways in the lungs due to the tightening of surrounding smooth muscle, with consequent coughing, wheezing, and shortness of breath. Causes The condition has a number of causes, the most common bei ...
. The standard plethysmograph sizes are for the study of mice, rats and guinea pigs. On request, larger plethysmographs can also be manufactured for other animals, such as rabbits, dogs, pigs, or primates. The plethysmograph has two chambers, each fitted with a pneumotachograph. The subject is placed in one of them (subject chamber) and the other remains empty (reference chamber). The pressure change is measured by a differential pressure transducer with one port exposed to the subject chamber and the other to the reference chamber.Hong Wang, Venkatraman Siddharthan, Kyle K. Kesler, Jeffery O. Hall, Neil E. Motter, Justin G. Julander and John D. Morrey (2013). Fatal Neurological Respiratory Insufficiency Is Common Among Viral Encephalitide
(free full text)
/ref>


Respiratory parameters from conscious restrained animals: double-chamber / head-out plethysmography

The double-chamber plethysmograph (dcp) measures respiratory parameters in a conscious restrained subject, including airway resistance and conductance. Different sizes of plethysmograph exist to study mice, rats or guinea pigs. The head-out configuration is identical to the standard configuration described above except that there is no head chamber. Of course the collar seal is still applied, so that the body chamber remains airtight. With only a thoracic signal, all parameters can be obtained except for specific airway resistance (SRaw) and specific airway conductance (Sgaw).


Resistance/compliance from sedated animals

In anesthetized plethysmography, lung resistance and dynamic compliance are measured directly because the subject is anesthetized. Depending on the level of sedation, the subject may be spontaneously breathing (SB configuration) or under mechanical ventilation (MV configuration). A flow signal and a pressure signal are required to calculate compliance and resistance.


Cerebral blood flow

Cerebral venous blood flow has been recently studied trying to establish a connection between Chronic cerebrospinal venous insufficiency and
multiple sclerosis Multiple sclerosis (MS) is an autoimmune disease resulting in damage to myelinthe insulating covers of nerve cellsin the brain and spinal cord. As a demyelinating disease, MS disrupts the nervous system's ability to Action potential, transmit ...
. The small study is not big enough to establish a conclusion, but some association has been shown.


See also

* Optoelectronic plethysmography *
Photoplethysmograph A photoplethysmogram (PPG) is an optically obtained plethysmograph, plethysmogram that can be used to detect blood volume changes in the microvascular bed of tissue. A PPG is often obtained by using a pulse oximeter which illuminates the skin a ...
* Respiratory inductance plethysmography


References

{{reflist


Further reading

* Glaab T, Taube C, Braun A, Mitzner W (2007) Invasive and noninvasive methods for studying pulmonary function in mice. ''Respiratory Research'' 8:63
free full text article


External links


Information on pulmonary function testing and physician reimbursementInformation on plethysmography used in preclinical research