An optode or optrode is an optical
sensor device that optically measures a specific substance usually with the aid of a chemical
transducer
A transducer is a device that converts energy from one form to another. Usually a transducer converts a signal in one form of energy to a signal in another.
Transducers are often employed at the boundaries of automation, measurement, and cont ...
.
Construction
An optode requires three components to function: a chemical that responds to an
analyte
An analyte, component (in clinical chemistry), or chemical species is a substance or chemical constituent that is of interest in an analytical procedure. The purest substances are referred to as analytes, such as 24 karat gold, NaCl, water, et ...
, a
polymer
A polymer (; Greek ''poly-'', "many" + '' -mer'', "part")
is a substance or material consisting of very large molecules called macromolecules, composed of many repeating subunits. Due to their broad spectrum of properties, both synthetic and ...
to immobilise the chemical transducer and instrumentation (
optical fibre
An optical fiber, or optical fibre in Commonwealth English, is a flexible, transparent fiber made by drawing glass (silica) or plastic to a diameter slightly thicker than that of a human hair. Optical fibers are used most often as a means ...
,
light source
Light or visible light is electromagnetic radiation that can be perceived by the human eye. Visible light is usually defined as having wavelengths in the range of 400–700 nanometres (nm), corresponding to frequencies of 750–420 terah ...
, detector and other electronics). Optodes usually have the polymer matrix coated onto the tip of an optical fibre, but in the case of
evanescent wave
In electromagnetics, an evanescent field, or evanescent wave, is an oscillating electric and/or magnetic field that does not propagate as an electromagnetic wave but whose energy is spatially concentrated in the vicinity of the source (oscillati ...
optodes the polymer is coated on a section of fibre that has been unsheathed.
Operation
Optodes can apply various optical measurement schemes such as
reflection,
absorption, evanescent wave,
luminescence
Luminescence is spontaneous emission of light by a substance not resulting from heat; or "cold light".
It is thus a form of cold-body radiation. It can be caused by chemical reactions, electrical energy, subatomic motions or stress on a crysta ...
(
fluorescence
Fluorescence is the emission of light by a substance that has absorbed light or other electromagnetic radiation. It is a form of luminescence. In most cases, the emitted light has a longer wavelength, and therefore a lower photon energy, ...
and
phosphorescence
Phosphorescence is a type of photoluminescence related to fluorescence. When exposed to light (radiation) of a shorter wavelength, a phosphorescent substance will glow, absorbing the light and reemitting it at a longer wavelength. Unlike fluo ...
s),
chemiluminescence
Chemiluminescence (also chemoluminescence) is the emission of light ( luminescence) as the result of a chemical reaction. There may also be limited emission of heat. Given reactants A and B, with an excited intermediate ◊,
: + -> lozenge - ...
,
surface plasmon resonance
Surface plasmon resonance (SPR) is the resonant oscillation of conduction electrons at the interface between negative and positive permittivity material in a particle stimulated by incident light. SPR is the basis of many standard tools for measu ...
. By far the most popular methodology is luminescence.
Luminescence in solution obeys the linear
Stern–Volmer relationship. Fluorescence of a molecule is
quenched
In materials science, quenching is the rapid cooling of a workpiece in water, oil, polymer, air, or other fluids to obtain certain material properties. A type of heat treating, quenching prevents undesired low-temperature processes, such as ...
by specific analytes, e.g.,
ruthenium
Ruthenium is a chemical element with the symbol Ru and atomic number 44. It is a rare transition metal belonging to the platinum group of the periodic table. Like the other metals of the platinum group, ruthenium is inert to most other chemic ...
complexes are quenched by oxygen. When a
fluorophore
A fluorophore (or fluorochrome, similarly to a chromophore) is a fluorescent chemical compound that can re-emit light upon light excitation. Fluorophores typically contain several combined aromatic groups, or planar or cyclic molecules with ...
is immobilised within a polymer matrix myriad micro-environments are created. The micro-environments reflect varying diffusion co-efficients for the analyte. This leads to a
non-linear
In mathematics and science, a nonlinear system is a system in which the change of the output is not proportional to the change of the input. Nonlinear problems are of interest to engineers, biologists, physicists, mathematicians, and many other ...
relationship between the fluorescence and the quencher (analyte). This relationship is modelled in various ways, the most popular model is the two site model created by James Demas (University of Virginia).
The signal (fluorescence) to oxygen ratio is not linear, and an optode is most sensitive at low oxygen concentration, i.e., the sensitivity decreases as oxygen concentration increases. The optode sensors can however work in the whole region 0–100%
oxygen saturation in water, and the calibration is done the same way as with the
Clark type sensor. No oxygen is consumed and hence the sensor is stirring insensitive, but the signal will stabilize more quickly if the sensor is stirred after being put into the sample.
Popularity
Optical sensors are growing in popularity due to the low-cost, low power requirements and long term stability. They provide viable alternatives to electrode-based sensors or more complicated analytical instrumentation, especially in the field of environmental monitoring although in the case of oxygen optrodes, they do not have the resolution as the most recent cathodic
microsensors.
[Revsbech NP, Thamdrup B, Dalsgaard T, Canfield DE (2011). Construction of STOX oxygen sensors and their application for determination of O2 concentrations in oxygen minimum zones. Methods Enzymol, 486:325-41.]
See also
*
Oxygen sensor