Neckarwestheim Nuclear Power Plant
   HOME

TheInfoList



OR:

Neckarwestheim Nuclear Power Station is a
nuclear power plant A nuclear power plant (NPP), also known as a nuclear power station (NPS), nuclear generating station (NGS) or atomic power station (APS) is a thermal power station in which the heat source is a nuclear reactor. As is typical of thermal power st ...
in Neckarwestheim,
Germany Germany, officially the Federal Republic of Germany, is a country in Central Europe. It lies between the Baltic Sea and the North Sea to the north and the Alps to the south. Its sixteen States of Germany, constituent states have a total popu ...
, sometimes abbreviated GKN (for ), operated by EnBW Kernkraft GmbH, a subsidiary of
EnBW EnBW Energie Baden-Württemberg AG, or simply EnBW, is a publicly-traded energy industry, energy company headquartered in Karlsruhe, Germany. History Foundation and development EnBW came into existence on 1 January 1997 as a result of the merge ...
. As part of the
nuclear power phase-out A nuclear power phase-out is the discontinuation of usage of nuclear power for energy production. Often initiated because of Politics of nuclear power, concerns about nuclear power, phase-outs usually include shutting down nuclear power plants ...
, it was taken out of service on April 15, 2023.


GKN 1

Unit I, in service since 1976, carried a nominal electrical power of 840 
megawatt The watt (symbol: W) is the unit of Power (physics), power or radiant flux in the International System of Units (SI), equal to 1 joule per second or 1 kg⋅m2⋅s−3. It is used to quantification (science), quantify the rate of Work ...
s. The 50 Hz
three phase Three-phase electric power (abbreviated 3ϕ) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. It is a type of polyphase system employing three wires (or four including an optional n ...
AC power was 567 megawatts and for the 16.7 Hz traction current power 174 MW. The traction current generator is the world's largest single-phase AC generators. The generator block 1 is rated 21,000 
volt The volt (symbol: V) is the unit of electric potential, Voltage#Galvani potential vs. electrochemical potential, electric potential difference (voltage), and electromotive force in the International System of Units, International System of Uni ...
s at a current of 27,000 
ampere The ampere ( , ; symbol: A), often shortened to amp,SI supports only the use of symbols and deprecates the use of abbreviations for units. is the unit of electric current in the International System of Units (SI). One ampere is equal to 1 c ...
s, and the traction current generator is rated 14,500 volts and a current of 12,000 amperes. The current produced by the generators was stepped up to 220 kilovolts (three-phase alternating current) or 110 kilovolts (single-phase traction current) with the unit
transformer In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple Electrical network, circuits. A varying current in any coil of the transformer produces ...
s. Unit I was the only nuclear power station which produced traction current. Block I was shut down on 17 March 2011, for a three-month moratorium on nuclear power, an announcement on 30 May 2011 named block I as a unit that would not be returning to service for political reasons.


GKN 2

Block 2, in service since 1988, has a nominal electrical power of 1400 megawatts. The generator produces 50 Hz three-phase alternating current with a voltage of 27,000 V and a current of 35,000 amperes. Unlike Unit 1, no dedicated traction current generation takes place, but some of the power produced is converted at the traction current substation. This is transmitted through the 380 kV generator transformer block of the II and the 380 kV-machine transformer of the motor-generator sets.


Traction current converter plant

The GKN station has a 16.7 Hz traction current converter plant. It is close to the switchgear of block II, has two identical sets, consisting of a three-phase 50 Hz AC motor with 12 poles and a four pole single phase 16.7 Hz AC synchronous generator. The rated voltage of the three-phase AC asynchronous machine and the traction current machine is 12.5 kV. The set has a length of 17.5 meters and a maximum width of 7 meters. The nominal power rating for each set is 70 megawatts, which are the largest traction current motor-generator sets ever built. It feeds the 110 kV
balanced line In telecommunications and professional audio, a balanced line or balanced signal pair is an electrical circuit consisting of two conductors of the same type, both of which have equal impedances along their lengths, to ground, and to other c ...
traction power network through appropriate transformers. Power can be transferred from the Block II nuclear generator over the 380 kV transmission network. As of 2011, there was a traction current inverter with a transmission rate of 140 MW under construction. It uses GTOs manufactured by ABB.


Dimensions

Dimensions of the outer concrete building of the double-
containment Containment was a Geopolitics, geopolitical strategic foreign policy pursued by the United States during the Cold War to prevent the spread of communism after the end of World War II. The name was loosely related to the term ''Cordon sanitaire ...
are height of around 54,5 m and diameter of around 67 m.


Cooling towers

In order to avoid overheating of the river
Neckar The Neckar () is a river in Germany, mainly flowing through the southwestern States of Germany, state of Baden-Württemberg, with a short section through Hesse. The Neckar is a major right tributary of the Rhine. Rising in the Schwarzwald-Baar ...
, both blocks have
cooling tower A cooling tower is a device that rejects waste heat to the atmosphere through the cooling of a coolant stream, usually a water stream, to a lower temperature. Cooling towers may either use the evaporation of water to remove heat and cool the ...
s. These are not built in the usual way. Block I uses two rows of cell cooling towers. Each row has a length of 186.8 meters and a height of 18 meters. Block II uses a hybrid cooling tower with a height of 51.22 meters. It was originally going to use a wet cooling tower, but later it was decided to use dry cooling towers because it would have less effect on the environment though more expensive. This unique type of cooling tower causes the unique shape seen in pictures.


Hybrid cooling tower

*Overall height: 51.22 m *overall height over basin level: 48.0 m *mouth diameter: 160.0 m *basin diameter: 120.0 m *chimney height: 24.97 m *air outlet diameter: 73.6 m *cooling performance: 2500 MW


Malfunctions

In 1977, Unit I had the second most serious incident of a nuclear power plant in the German Federal Republic to that date. Numerous errors of a new crew led to damage of the secondary cycle and, at the same time, a defect of a valve led to an automatic reactor shutdown. On 27 July 2004, slightly radioactively contaminated water with two mega
becquerel The becquerel (; symbol: Bq) is the unit of radioactivity in the International System of Units (SI). One becquerel is defined as an activity of one per second, on average, for aperiodic activity events referred to a radionuclide. For applicatio ...
s activity was discharged from Unit II into the Neckar river. As a result, for the first time in the Federal Republic, the operator company of a nuclear power plant paid a fine of €25,000 and a
managing director A chief executive officer (CEO), also known as a chief executive or managing director, is the top-ranking corporate officer charged with the management of an organization, usually a company or a nonprofit organization. CEOs find roles in variou ...
was dismissed.


Powerlines

Power produced at GKN is transmitted over a
transmission line In electrical engineering, a transmission line is a specialized cable or other structure designed to conduct electromagnetic waves in a contained manner. The term applies when the conductors are long enough that the wave nature of the transmis ...
carrying two circuits of traction current and three-phase alternating current line to the 220 kV-three phase AC and the 110 kV-traction current switchyard situated east of Neckarwestheim. This line is hung on pylons of unusual design with five cross beams. On the lowest cross bar there are two traction current circuits, while the second, third and fourth cross beam carry the three-phase circuits. These are operated, in the case of the GKN 1, with 220 kV and in the case of the GKN 2 with 380 kV. On the highest cross beam two ground conductors are installed. It is notable that the traction current circuits were insulated for 220 kV, although they are operated only with 110 kV. This measure was taken because, in case of a disturbance of the parallel 380 kV-line, overvoltages can occur which insulation designed for 110 kV cannot stand. The traction current lines from the GKN to the traction current switching station at Neckarwestheim, and from there to the central substation in
Stuttgart Stuttgart (; ; Swabian German, Swabian: ; Alemannic German, Alemannic: ; Italian language, Italian: ; ) is the capital city, capital and List of cities in Baden-Württemberg by population, largest city of the States of Germany, German state of ...
Zazenhausen, are implemented as four-bundle conductors. The three-phase 380 kV circuit leading away from the nuclear power station GKN 2 runs past the 220 kV-three phase switchyard at Neckarwestheim to the transformer station at Großgartach near
Heilbronn Heilbronn () is a List of cities and towns in Germany, city in northern Baden-Württemberg, Germany, surrounded by Heilbronn (district), Heilbronn District. From the late Middle Ages on, it developed into an important trading centre. At the begi ...
. another 110 kV-line for three phase AC with one circuit which originates in the switchgear of the
coal-fired power station A coal-fired power station or coal power plant is a thermal power station which burns coal to generate electricity. Worldwide there are about 2,500 coal-fired power stations, on average capable of generating a gigawatt each. They generate ...
at Walheim also runs to the GKN. This line is not for export of the power produced by the GKN, but for start-up power for the nuclear plant. Neckarwestheim and the GKN have never had a track connection to the railway network.


Public opposition

Geologist Hermann Behmel was a prominent opponent of the Neckarwestheim Nuclear Power Plant. In April 2009, anti-nuclear activists blocked the entrance to the controversial Neckarwestheim Nuclear Plant with an 8-metre wall. Their protest coincided with the annual meeting of the company that runs the plant, Energie Baden-Württemberg (EnBW).


Popular culture

On April 23rd 2014, the power plant featured on an episode of The Technical Difficulties in the game 'Citation Needed' presented by Tom Scott, Gary Brannan, Matt Gray, and Chris Joel. Neckarwestheim and the End of the World: Citation Needed 1x06
/ref>


References

{{Authority control EnBW Former nuclear power stations in Germany Buildings and structures in Heilbronn (district) Economy of Baden-Württemberg