An ion trap is a combination of
electric
Electricity is the set of physical phenomena associated with the presence and motion of matter possessing an electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described by Maxwel ...
and/or
magnetic field
A magnetic field (sometimes called B-field) is a physical field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular ...
s used to capture charged particles — known as
ion
An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by convent ...
s — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in physics and chemistry such as precision
mass spectrometry
Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a ''mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used ...
, improved atomic frequency standards, and
quantum computing
A quantum computer is a computer that exploits quantum mechanical phenomena. On small scales, physical matter exhibits properties of wave-particle duality, both particles and waves, and quantum computing takes advantage of this behavior using s ...
. In comparison to neutral atom traps, ion traps have deeper trapping potentials (up to several
electronvolt
In physics, an electronvolt (symbol eV), also written electron-volt and electron volt, is the measure of an amount of kinetic energy gained by a single electron accelerating through an Voltage, electric potential difference of one volt in vacuum ...
s) that do not depend on the internal electronic structure of a trapped ion. This makes ion traps more suitable for the study of light interactions with single atomic systems. The two most popular types of ion traps are the
Penning trap
A Penning trap is a device for the storage of charged particles using a homogeneous magnetic field and a quadrupole electric field. It is mostly found in the physical sciences and related fields of study for precision measurements of properties o ...
, which forms a potential via a combination of static electric and magnetic fields, and the
Paul trap
In experimental physics, a quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented ...
which forms a potential via a combination of static and oscillating electric fields.
Penning traps can be used for precise magnetic measurements in spectroscopy. Studies of quantum state manipulation most often use the Paul trap. This may lead to a
trapped ion quantum computer
A trapped-ion quantum computer is one proposed approach to a large-scale quantum computer. Ions, or charged atomic particles, can be confined and suspended in free space using electromagnetic fields. Qubits are stored in stable electronic state ...
and has already been used to create the world's most accurate
atomic clocks
An atomic clock is a clock that measures time by monitoring the resonant frequency of atoms. It is based on atoms having different energy levels. Electron states in an atom are associated with different energy levels, and in transitions betwee ...
.
Electron gun
file:Egun.jpg, Electron gun from a cathode-ray tube
file:Vidicon Electron Gun.jpg, The electron gun from an RCA Vidicon video camera tube
An electron gun (also called electron emitter) is an electrical component in some vacuum tubes that produc ...
s (a device emitting high-speed electrons, used in
CRT
CRT or Crt most commonly refers to:
* Cathode-ray tube, a display
* Critical race theory, an academic framework of analysis
CRT may also refer to:
Law
* Charitable remainder trust, United States
* Civil Resolution Tribunal, Canada
* Columbia ...
s) can use an ion trap to prevent degradation of the
cathode
A cathode is the electrode from which a conventional current leaves a polarized electrical device such as a lead-acid battery. This definition can be recalled by using the mnemonic ''CCD'' for ''Cathode Current Departs''. Conventional curren ...
by positive ions.
History
The physical principles of ion traps were first explored by
F. M. Penning (1894–1953), who observed that electrons released by the cathode of an
ionization vacuum gauge follow a long cycloidal path to the anode in the presence of a sufficiently strong magnetic field.
A scheme for confining charged particles in three dimensions without the use of magnetic fields was developed by
W. Paul based on his work with
quadrupole mass spectrometers.
Ion traps were used in
television receiver
A television set or television receiver (more commonly called TV, TV set, television, telly, or tele) is an electronic device for viewing and hearing television broadcasts, or as a computer monitor. It combines a tuner, display, and loudspeake ...
s prior to the introduction of aluminized
CRT
CRT or Crt most commonly refers to:
* Cathode-ray tube, a display
* Critical race theory, an academic framework of analysis
CRT may also refer to:
Law
* Charitable remainder trust, United States
* Civil Resolution Tribunal, Canada
* Columbia ...
faces around 1958, to protect the phosphor screen from ions. The ion trap must be delicately adjusted for maximum brightness.
Theory

Any charged particle, such as an
ion
An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by convent ...
, feels a force from an electric or magnetic field. Ion traps work by using this force to confine ions in a small, isolated volume of space so that they can be studied or manipulated. Although any static (constant in time) electromagnetic field produces a force on an ion, it is not possible to confine an ion using only a static electric field. This is a consequence of
Earnshaw's theorem
Earnshaw's theorem states that a collection of point charges cannot be maintained in a stable stationary equilibrium configuration solely by the electrostatic interaction of the charges. This was first proven by British mathematician Samuel Earns ...
. However, physicists have various ways of working around this theorem by using combinations of static magnetic and electric fields (as in a
Penning trap
A Penning trap is a device for the storage of charged particles using a homogeneous magnetic field and a quadrupole electric field. It is mostly found in the physical sciences and related fields of study for precision measurements of properties o ...
) or by an oscillating electric field and a static electric field(
Paul trap
In experimental physics, a quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented ...
). Ion motion and confinement in the trap is generally divided into axial and radial components, which are typically addressed separately by different fields. In both Paul and Penning traps, axial ion motion is confined by a static electric field. Paul traps use an oscillating electric field to confine the ion radially and Penning traps generate radial confinement with a static magnetic field.
Paul Trap
A Paul trap that uses an oscillating
quadrupole
A quadrupole or quadrapole is one of a sequence of configurations of things like electric charge or current, or gravitational mass that can exist in ideal form, but it is usually just part of a multipole expansion of a more complex structure re ...
field to trap ions radially and a static potential to confine ions axially. The quadrupole field is realized by four parallel electrodes laying in the
-axis positioned at the corners of a square in the
-plane. Electrodes diagonally opposite each other are connected and an a.c. voltage
is applied. Using
Maxwell's equations
Maxwell's equations, or Maxwell–Heaviside equations, are a set of coupled partial differential equations that, together with the Lorentz force law, form the foundation of classical electromagnetism, classical optics, Electrical network, electr ...
, the electric field produced by this potential is electric field
. Applying
Newton's second law
Newton's laws of motion are three physical laws that describe the relationship between the motion of an object and the forces acting on it. These laws, which provide the basis for Newtonian mechanics, can be paraphrased as follows:
# A body re ...
to an ion of charge
and mass
in this a.c. electric field, we can find the force on the ion using
. We wind up with
:
.
Assuming that the ion has zero initial velocity, two successive integrations give the velocity and displacement as
:
,
:
,
where
is a constant of integration. Thus, the ion oscillates with angular frequency
and amplitude proportional to the electric field strength and is confined radially.
Working specifically with a linear Paul trap, we can write more specific equations of motion. Along the
-axis, an analysis of the radial symmetry yields a potential
:
.
The constants
and
are determined by boundary conditions on the electrodes and
satisfies
Laplace's equation
In mathematics and physics, Laplace's equation is a second-order partial differential equation named after Pierre-Simon Laplace, who first studied its properties in 1786. This is often written as
\nabla^2\! f = 0 or \Delta f = 0,
where \Delt ...
. Assuming the length of the electrodes
is much greater than their separation
, it can be shown that
:
.
Since the electric field is given by the gradient of the potential, we get that
:
.
Defining
, the equations of motion in the
-plane are a simplified form of the
Mathieu equation
In mathematics, Mathieu functions, sometimes called angular Mathieu functions, are solutions of Mathieu's differential equation
:
\frac + (a - 2q\cos(2x))y = 0,
where are real-valued parameters. Since we may add to to change the sign of , i ...
,
:
.
Penning Trap
A standard configuration for a
Penning trap
A Penning trap is a device for the storage of charged particles using a homogeneous magnetic field and a quadrupole electric field. It is mostly found in the physical sciences and related fields of study for precision measurements of properties o ...
consists of a ring electrode and two end caps. A static voltage differential between the ring and end caps confines ions along the axial direction (between end caps). However, as expected from
Earnshaw's theorem
Earnshaw's theorem states that a collection of point charges cannot be maintained in a stable stationary equilibrium configuration solely by the electrostatic interaction of the charges. This was first proven by British mathematician Samuel Earns ...
, the static electric potential is not sufficient to trap an ion in all three dimensions. To provide the radial confinement, a strong axial magnetic field is applied.
For a uniform electric field
, the force
accelerates a positively charged ion along the
-axis. For a uniform magnetic field
, the
Lorentz
Lorentz is a name derived from the Roman surname, Laurentius, which means "from Laurentum". It is the German form of Laurence. Notable people with the name include:
Given name
* Lorentz Aspen (born 1978), Norwegian heavy metal pianist and keyboar ...
force causes the ion to move in circular motion with
cyclotron frequency
In physics, cyclotron motion, also known as gyromotion, refers to the circular motion exhibited by charged particles in a uniform magnetic field.
The circular trajectory of a particle in cyclotron motion is characterized by an angular frequency r ...
:
.
Assuming an ion with zero initial velocity placed in a region with
and
, the equations of motion are
:
,
:
,
:
.
The resulting motion is a combination of oscillatory motion around the
-axis with frequency
and a drift velocity in the
-direction. The drift velocity is perpendicular to the direction of the electric field.
For the radial electric field produced by the electrodes in a Penning trap, the drift velocity will precess around the axial direction with some frequency
, called the magnetron frequency. An ion will also have a third characteristic frequency
between the two end cap electrodes. The frequencies usually have widely different values with
.
Ion trap mass spectrometers

An ion trap
mass spectrometer
Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a '' mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is us ...
may incorporate a Penning trap (
Fourier-transform ion cyclotron resonance
Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (''m''/''z'') of ions based on the ion cyclotron resonance, cyclotron frequency of the ions in a ...
),
Paul trap
In experimental physics, a quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented ...
or the
Kingdon trap.
The
Orbitrap
In mass spectrometry, Orbitrap is an ion trap mass analyzer consisting of an outer barrel-like electrode and a coaxial inner spindle-like electrode that traps ions in an orbital motion around the spindle. The image current from the trapped ions i ...
, introduced in 2005, is based on the Kingdon trap. Other types of mass spectrometers may also use a linear quadrupole ion trap as a selective mass filter.
Penning ion trap
A
Penning trap
A Penning trap is a device for the storage of charged particles using a homogeneous magnetic field and a quadrupole electric field. It is mostly found in the physical sciences and related fields of study for precision measurements of properties o ...
stores charged particles using a strong homogeneous axial
magnetic field
A magnetic field (sometimes called B-field) is a physical field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular ...
to confine particles radially and a quadrupole
electric field
An electric field (sometimes called E-field) is a field (physics), physical field that surrounds electrically charged particles such as electrons. In classical electromagnetism, the electric field of a single charge (or group of charges) descri ...
to confine the particles axially. Penning traps are well suited for measurements of the properties of
ions
An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by convent ...
and stable charged
subatomic particle
In physics, a subatomic particle is a particle smaller than an atom. According to the Standard Model of particle physics, a subatomic particle can be either a composite particle, which is composed of other particles (for example, a baryon, lik ...
s. Precision studies of the electron magnetic moment by Dehmelt and others are an important topic in modern physics.
Penning traps can be used in
quantum computation
A quantum computer is a computer that exploits quantum mechanical phenomena. On small scales, physical matter exhibits properties of both particles and waves, and quantum computing takes advantage of this behavior using specialized hardware. C ...
and
quantum information processing
Quantum information science is a field that combines the principles of quantum mechanics with information theory to study the processing, analysis, and transmission of information. It covers both theoretical and experimental aspects of quantum phys ...
and are used at
CERN
The European Organization for Nuclear Research, known as CERN (; ; ), is an intergovernmental organization that operates the largest particle physics laboratory in the world. Established in 1954, it is based in Meyrin, western suburb of Gene ...
to store antimatter. Penning traps form the basis of
Fourier-transform ion cyclotron resonance mass spectrometry for determining the
mass-to-charge ratio
The mass-to-charge ratio (''m''/''Q'') is a physical quantity Ratio, relating the ''mass'' (quantity of matter) and the ''electric charge'' of a given particle, expressed in Physical unit, units of kilograms per coulomb (kg/C). It is most widely ...
of
ions
An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by convent ...
.
The Penning Trap was invented by
Frans Michel Penning
Frans Michel Penning (12 September 1894 – 6 December 1953) was a Dutch experimental physicist. He received his PhD from the University of Leiden in 1923, and studied low pressure gas discharges at the Philips Laboratory in Eindhoven, developing ...
and
Hans Georg Dehmelt
Hans Georg Dehmelt (; 9 September 1922 – 7 March 2017) was a German and American physicist, who was awarded a Nobel Prize in Physics in 1989, for co-developing the ion trap technique (Penning trap) with Wolfgang Paul, for which they shared one-h ...
, who built the first trap in the 1950s.
Paul ion trap
A Paul trap is a type of
quadrupole ion trap
In experimental physics, a quadrupole ion trap or paul trap is a type of ion trap that uses dynamic electric fields to trap charged particles. They are also called radio frequency (RF) traps or Paul traps in honor of Wolfgang Paul, who invented ...
that uses static
direct current
Direct current (DC) is one-directional electric current, flow of electric charge. An electrochemical cell is a prime example of DC power. Direct current may flow through a conductor (material), conductor such as a wire, but can also flow throug ...
(DC) and
radio frequency
Radio frequency (RF) is the oscillation rate of an alternating electric current or voltage or of a magnetic, electric or electromagnetic field or mechanical system in the frequency range from around to around . This is roughly between the u ...
(RF) oscillating
electric field
An electric field (sometimes called E-field) is a field (physics), physical field that surrounds electrically charged particles such as electrons. In classical electromagnetism, the electric field of a single charge (or group of charges) descri ...
s to trap ions. Paul traps are commonly used as components of a
mass spectrometer
Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a '' mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is us ...
. The invention of the 3D quadrupole ion trap itself is attributed to
Wolfgang Paul
Wolfgang Paul (; 10 August 1913 – 7 December 1993) was a German physicist, who co-developed the non-magnetic quadrupole mass filter which laid the foundation for what is now called an ion trap. He shared one-half of the Nobel Prize in Ph ...
who shared the
Nobel Prize in Physics
The Nobel Prize in Physics () is an annual award given by the Royal Swedish Academy of Sciences for those who have made the most outstanding contributions to mankind in the field of physics. It is one of the five Nobel Prizes established by the ...
in 1989 for this work. The trap consists of two
hyperbolic
Hyperbolic may refer to:
* of or pertaining to a hyperbola, a type of smooth curve lying in a plane in mathematics
** Hyperbolic geometry, a non-Euclidean geometry
** Hyperbolic functions, analogues of ordinary trigonometric functions, defined u ...
metal electrodes with their foci facing each other and a hyperbolic ring electrode halfway between the other two electrodes.
Ion
An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by convent ...
s are trapped in the space between these three electrodes by the oscillating and static electric fields.
Kingdon trap and orbitrap

A Kingdon trap consists of a thin central wire, an outer cylindrical electrode and isolated end cap electrodes at both ends. A static applied voltage results in a radial logarithmic potential between the electrodes.
In a Kingdon trap there is no potential minimum to store the ions; however, they are stored with a finite angular momentum about the central wire and the applied electric field in the device allows for the stability of the ion trajectories.
In 1981, Knight introduced a modified outer electrode that included an axial quadrupole term that confines the ions on the trap axis.
The dynamic Kingdon trap has an additional AC voltage that uses strong defocusing to permanently store charged particles.
The dynamic Kingdon trap does not require the trapped ions to have angular momentum with respect to the filament. An
Orbitrap
In mass spectrometry, Orbitrap is an ion trap mass analyzer consisting of an outer barrel-like electrode and a coaxial inner spindle-like electrode that traps ions in an orbital motion around the spindle. The image current from the trapped ions i ...
is a modified Kingdon trap that is used for
mass spectrometry
Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a ''mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used ...
. Though the idea has been suggested and computer simulations performed
neither the Kingdon nor the Knight configurations were reported to produce mass spectra, as the simulations indicated mass resolving power would be problematic.
Trapped ion quantum computer
Some experimental work towards developing quantum computers use
trapped ion
An ion trap is a combination of electric and/or magnetic fields used to capture charged particles — known as ions — often in a system isolated from an external environment. Atomic and molecular ion traps have a number of applications in p ...
s. Units of
quantum information
Quantum information is the information of the state of a quantum system. It is the basic entity of study in quantum information theory, and can be manipulated using quantum information processing techniques. Quantum information refers to both t ...
called
qubits
In quantum computing, a qubit () or quantum bit is a basic unit of quantum information—the quantum version of the classic binary bit physically realized with a two-state device. A qubit is a two-state (or two-level) quantum-mechanical system, ...
are stored in stable electronic states of each ion, and
quantum information
Quantum information is the information of the state of a quantum system. It is the basic entity of study in quantum information theory, and can be manipulated using quantum information processing techniques. Quantum information refers to both t ...
can be processed and transferred through the collective quantized motion of the ions, interacting by the
Coulomb force
Coulomb's inverse-square law, or simply Coulomb's law, is an experimental law of physics that calculates the amount of force between two electrically charged particles at rest. This electric force is conventionally called the ''electrostatic ...
.
Lasers
A laser is a device that emits light through a process of optical amplification based on the stimulated emission of electromagnetic radiation. The word ''laser'' originated as an acronym for light amplification by stimulated emission of radi ...
are applied to induce
coupling
A coupling is a device used to connect two shafts together at their ends for the purpose of transmitting power. The primary purpose of couplings is to join two pieces of rotating equipment while permitting some degree of misalignment or end mo ...
between the qubit states (for single qubit operations) or between the internal qubit states and external motional states (for entanglement between qubits).
See also
*
Laser cooling
Laser cooling includes several techniques where atoms, molecules, and small mechanical systems are cooled with laser light. The directed energy of lasers is often associated with heating materials, e.g. laser cutting, so it can be counterintuit ...
*
Mass spectrometry
Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a ''mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used ...
*
Quantum jump
Quantum Jump were a 1970s British band, consisting of singer and keyboard player Rupert Hine, guitarist Mark Warner, bass player John G. Perry (then of Caravan), and drummer Trevor Morais (who had previously played in The Peddlers). The ba ...
References
External links
VIAS Science CartoonsA cranky view of an ion trap...
{{DEFAULTSORT:Ion Trap
Mass spectrometry
Ions