Ikata Nuclear Power Plant
   HOME

TheInfoList



OR:

The is a
nuclear power plant A nuclear power plant (NPP), also known as a nuclear power station (NPS), nuclear generating station (NGS) or atomic power station (APS) is a thermal power station in which the heat source is a nuclear reactor. As is typical of thermal power st ...
in the town of Ikata in the Nishiuwa District of
Ehime Prefecture is a Prefectures of Japan, prefecture of Japan located on the island of Shikoku. Ehime Prefecture has a population of 1,334,841 and a geographic area of 5,676 km2 (2,191 sq mi). Ehime Prefecture borders Kagawa Prefecture to the northeast, Toku ...
,
Japan Japan is an island country in East Asia. Located in the Pacific Ocean off the northeast coast of the Asia, Asian mainland, it is bordered on the west by the Sea of Japan and extends from the Sea of Okhotsk in the north to the East China Sea ...
. It is the only nuclear plant on the island of
Shikoku is the smallest of the List of islands of Japan#Main islands, four main islands of Japan. It is long and between at its widest. It has a population of 3.8 million, the least populated of Japan's four main islands. It is south of Honshu ...
. It is owned and operated by the Shikoku Electric Power Company. The plant was shut down along with all other nuclear plants in Japan following the
Fukushima Daiichi nuclear disaster The Fukushima nuclear accident was a major nuclear accident at the Fukushima Daiichi Nuclear Power Plant in Ōkuma, Fukushima, Japan, which began on 11 March 2011. The cause of the accident was the 2011 Tōhoku earthquake and tsunami, which r ...
. Unit 3 was reactivated using plutonium-uranium mixed oxide fuel on 12 August 2016 and began providing electricity to the grid three days later. On 13 December 2017, the Hiroshima High Court issued a temporary injunction to halt the operation of the Ikata 3 nuclear reactor until September 2018. The injunction was revoked in March 2021 and Ikata 3 was restarted in December 2021. The plant is on a site with an area of ; 47% of the plant site is green, in comparison the non-nuclear plants Shikoku Electric operates are 13.8, 20.1, 21.2 and 45.5%.Yonden (Japanese)
Yonden Activities to Protect the Environment


Reactors on site


Important events


Accidents

On 3 March 2004, there was a coolant leak in Unit 3.


Technical achievements

On 13 August 2003, the maximum burnup for spent fuel was changed from 48,000 MWd/ton to 55,000 MWd/ton. In January 2006
Mitsubishi Heavy Industries is a Japanese Multinational corporation, multinational engineering, electrical equipment and electronics corporation headquartered in Tokyo, Japan. MHI is one of the core companies of the Mitsubishi Group and its automobile division is the prede ...
announced the completion of the replacement of the internal structure of the No.1 reactor. It was the world's first all-in-one-piece extraction and replacement of the core internals of a PWR reactor. The upper and lower internals of the reactor were replaced in order to accommodate more control rods and allow for higher fuel burnup. In 2010, a partial
MOX fuel Mixed oxide fuel (MOX fuel) is nuclear fuel that contains more than one oxide of fissile material, usually consisting of plutonium blended with natural uranium, reprocessed uranium, or depleted uranium. MOX fuel is an alternative to the low-enr ...
core was loaded into the No.3 reactor for the cycle beginning 24 February 2010.


Maintenance in 2011

On Sunday 4 September reactor no. 1 was shut down for regular inspections. These check-ups would last at least three months. At that time reactor No.3 was also shut down, although the normal inspections were long time finished before September. To resume operation, a stress test was required for all suspended reactors by the government, after the accidents in Fukushima. The Ehime prefectural government said it would decide whether to approve the resumption of operations after the results of the safety test came out. The Shikoku Electric Power Company said that if the No. 3 reactor did not resume operations, power supplies would be very tight in winter when electricity demand would be high. It was considered to restart a thermal power-plant which had been long out of use.


Nuclear evacuation drill held in 2012

In February 2012 an evacuation drill was held in the prefecture Ehime and Shimane. The drill was done to mimic the situation of a reactor cooling failure after a huge earthquake. The evacuation-zones were expanded from 10 to 30 kilometers after the disaster in
Fukushima Daiichi nuclear power plant The is a disabled nuclear power plant located on a site in the towns of Ōkuma, Fukushima, Ōkuma and Futaba, Fukushima, Futaba in Fukushima Prefecture, Japan. The plant Fukushima Daiichi nuclear disaster, suffered major damage from the 201 ...
. In this evacuation drill some 10.000 people were taken out of the area round the nuclear power plant, with buses, helicopters and boats of the Maritime Self-Defense Force. The residents in the town of Ikata, commanded by disaster announcements on the radio to gather at a junior high school. From there they were taken by buses to a shelter some 50 kilometers further. This drill was the first executed on this scale, and it was also the first time that so many people were evacuated out from their town.


Unit 3 restart in 2016

On 19 April 2016, unit 3 received from
NRA NRA may refer to: Organizations Asia and Oceania * National Railway Administration, the national railway regulator of China * National Recruitment Agency, Central Recruiting Agency of the Indian Government * New Revolutionary Alternative, an anar ...
the final approval to restarting. On 27 June, Shikoku Electric completed loading 157 fuel assemblies, of which 16 uranium-plutonium mixed oxide (MOX). Unit 3 achieved criticality on 13 August and resumed commercial service on 7 September. However, on 13 December 2017 the Hiroshima High Court revoked the lower court decision, ordering the close of the unit until the end of September 2018. Shikoku Electric plans to appeal. The dispute centres on the evaluation of earthquake risk under the stricter post Fukushima regulations. In January 2020 the High Court passed a further injunction against the operation of unit 3, again in part because an active fault nearby could not be ruled out as a full geological survey of the area had not been conducted.


Unit 3 restart in 2021

In March 2021, the Hiroshima High Court revoked the injunction, following an appeal by the plant operator, clearing it to resume operations. The court said residents bear the burden of proof for risks posed by the nuclear plant. The plant operator then planned to restart the reactor in October. Unit 3 was eventually restarted on 2 December 2021.


Cultural references

In the film '' Godzilla vs. Destoroyah'' (1995),
Godzilla is a fictional monster, or ''kaiju'', that debuted in the eponymous 1954 film, directed and co-written by Ishirō Honda. The character has since become an international pop culture icon, appearing in various media: 33 Japanese films p ...
, suffering from nuclear meltdown, approached the nuclear plant for energy, emerging from below the surface of the Bungo Channel. The
Japan Self Defense Forces The are the Military, military forces of Japan. Established in 1954, the JSDF comprises the Japan Ground Self-Defense Force, the Japan Maritime Self-Defense Force, and the Japan Air Self-Defense Force. They are controlled by the Ministry of D ...
are deployed to stall Godzilla and defend the facility, fearing that a direct attack against him could cause a nuclear explosion and destroy the planet. Thankfully, the Super X-III aircraft comes to the rescue and temporarily freezes Godzilla before he can begin attacking the power plant.


See also

* List of nuclear power plants in Japan


References


External links


Shikoku Electric Company