Hydropneumatic devices (or hydro-pneumatic devices) are systems that operate using water and gas. The devices are used in various applications.


Description

A hydropneumatic device is a tool that functions by using water and gas. ''Hydropneumatic'' refers to the
pneumatic Pneumatics (from Greek 'wind, breath') is the use of gas or pressurized air in mechanical systems. Pneumatic systems used in Industrial sector, industry are commonly powered by compressed air or compressed inert gases. A centrally located a ...
(gas) and
hydraulic Hydraulics () is a technology and applied science using engineering, chemistry, and other sciences involving the mechanical properties and use of liquids. At a very basic level, hydraulics is the liquid counterpart of pneumatics, which concer ...
(water) components needed for operation of the devices. Hydropneumatic accumulators or pulsation dampeners are devices which prevent, but do not absorb, alleviate, arrest, attenuate, or suppress a shock that already exists, meaning that these devices prevent the creation of a shock wave at an otherwise earlier stage. These can include pulsation dampeners, hydropneumatic accumulators,
water hammer Hydraulic shock ( colloquial: water hammer; fluid hammer) is a pressure surge or wave caused when a fluid in motion is forced to stop or change direction suddenly: a momentum change. It is usually observed in a liquid but gases can also be aff ...
preventers, water hammer arrestors, and other things.


Devices


Hydropneumatic suspension


Hydropneumatic lock


Hydropneumatic recoil mechanism


Hydropneumatic water hammer preventers

Hydropneumatic water hammer preventers are chambers of sufficient volume to allow an extension of time in which a given flow may be accelerated or decelerated without sudden large change in pressure. See also expansion tank. When shock waves of an incompressible fluid within a piping system exist, especially at a high velocity, there is a high chance for water hammer. To help prevent a swing check from slamming and causing water hammer, a spring-assisted non-slam check valve is installed. Rather than relying on flow or gravity to be closed, the non-slam design prevents a sudden velocity decrease and reverse flow. The hydropneumatic water hammer preventer chamber is generally adapted to contain a separator member which prevents the escape of a pre-filled compressed
inert gas An inert gas is a gas that does not readily undergo chemical reactions with other chemical substances and therefore does not readily form chemical compounds. Though inert gases have a variety of applications, they are generally used to prevent u ...
. They may be # Placed closely before a valve that is closed quickly. Stops water hammering. # Placed immediately after the discharge of a pump that is started fast into a pipe full of a long column of liquid. Reduces start up surge pressure. # Placed immediately after a pump, which when caused to stop suddenly, enables a vacuum to form, which pulls the flow back towards the pump. Prevents an implosion bang. Variations on the design include # Having a separator membrane into the interior of which the liquid is communicated. Used for corrosive liquids, so that the chamber metal can be of low cost. # Having a metal bellows separator membrane for use at low and higher temperatures than are compatible with an elastomeric or plastomeric membrane. # Having a float separator to reduce the rate of gas absorption at the liquid interface, typically used in vessel chambers larger than 500 gallons.


Hydropneumatic pump controllers

Hydropneumatic pump controllers provide a # Means of control for multiple fixed delivery volume, low cost low complexity pumps; to provide variable flow as required by small (say +/- 10 psi) pressure increase or decrease of a system. # Means of control for pump unloading / recirculation against no pressure, without electric pressure switches. The controllers are pressure cylinders containing a movable separator member between a gas and a liquid, said moveable member causing the actuation of directional control valve or valves. The controllers are used in a circuit after a pump that is followed by a valved-side branch, and beyond a check valve, so that this device can only discharge liquid volume by a pressure fall of the system. Variations on the design include # Having a protruding drive rod, cams from which trip valve handles. # Having magnetically actuated reed switched. # Having infrared signaling of separator position.


Hydropneumatic pulsation filters

Hydropneumatic pulsation filters provide means of reducing the amplitude of pressure changes the velocity of which is in the order of 1.4 km/s. All are used in industry. A hydropneumatic pulsation filter is a pressure container with separate inlet and outlet, connectable to a pipe system so that all pressure changes must attempt to pass through said chamber. Entry and exit of said chamber being of a diameter relative to chamber diameter that provides a high discharge coefficient, and without close proximity of any reflective surface. Lack of any sudden change in cross section area of flow path that would reflect a pressure wave, i.e. no orifice plate(s). Variations include Combination "dual purpose" devices addressing "acceleration head reduction" by means of a gas containment. The devices have applications by frequency response * For pulsation above frequency 100 Hz (i.e., for high speed pumps and all pipe systems shorter than say 80 yards): no
moving parts Machines include both fixed and moving parts. The moving parts have controlled and constrained motions. Moving parts are machine components excluding any moving fluids, such as fuel, coolant or hydraulic fluid. Moving parts also do not include ...
devices. * For pulsation frequencies below 100 Hz: certain moving parts devices of known membrane response characteristics.


Hydropneumatic acceleration head reducers

Hydropneumatic acceleration head reducers minimize the mass of liquid that has to be accelerated when
flow velocity In continuum mechanics the flow velocity in fluid dynamics, also macroscopic velocity in statistical mechanics, or drift velocity in electromagnetism, is a vector field used to mathematically describe the motion of a continuum. The length of the f ...
changes. Within a piping system, pressure rises when a volume of fluid becomes present. This acceleration head needs to be reduced to prevent damage to pump components and excessive noise. These devices are typically mountable in any orientation such that the device is connectable directly to the suction check valve beneath the pump or directly to any vertical or horizontal discharge check valve; minimizing the length of any liquid column mass that will experience velocity change. Pump connection being separate from system connection so that no acceleration head changes occur due to reciprocation within one port. Applications for hydropneumatic acceleration head reducers include # Reduction in drive energy costs required by any pump. # Reduction in pipe diameter and schedule (wall thickness) costs of any pipe system. # Decrease in fatigue and increase in safety of all pressure piping systems. # Increase in accuracy and automatability of all pressure and flow control instruments. # Increase in rotating equipment life and MTBF. # Reduction in service down time. Variations on the design include # For chemicals and process pump systems: having
PTFE Polytetrafluoroethylene (PTFE) is a synthetic fluoropolymer of tetrafluoroethylene, and has numerous applications because it is chemically inert. The commonly known brand name of PTFE-based composition is Teflon by Chemours, a spin-off fro ...
membranes. # For sludges and slurries: having a clear unobstructed flow path direct from in to out. # For general purposes: having an elastomeric bladder separator.


Pulsation dampeners


Misuse of the term

Some manufacturers of pulsation dampeners provide items which do not dampen pulsations. The compressibility of a gas, often nitrogen because it is inert at normal temperatures, stores any sudden volume change. Storing sudden volume change enables volume to change against a soft gas cushion, without the need to accelerate all the existing liquid in the system out of the way of the new volume coming from a pump. Therefore, as all the volume in a system does not have to be suddenly accelerated, the cushion is preventing "acceleration head" (force) having to be generated. The pressure pulse is accordingly not generated in the first place, so it is not dampened at all. The gas cushion simply allows volume change to be stored. The manufacturers are providing, are liquid accumulators, not an item which removes energy.


Hydropneumatic accumulators

Gas cushion (spring) pre-filled accumulators of liquids are called hydropneumatic accumulators. "Hydro" because a liquid (like water) is involved. "Pneumatic" because a gas (like air) is involved. "Accumulator" because the purpose is to store or accumulate liquid volume by easy compression of the gas. These devices are typified by having only one liquid connection that goes to a "T" on the system.


Non-hydropneumatic

There are other forms of accumulator used for fluid power hydraulic purposes. For example, coil spring plus sealed piston; though these are less popular. Therefore, a
hydraulic accumulator A hydraulic accumulator is a pressure storage reservoir in which an Incompressible flow, incompressible hydraulic fluid is held under pressure that is applied by an external Prime mover (engine), source of mechanical energy. The external source can ...
is not necessarily a hydropneumatic accumulator.


References