The flyback converter is used in both
AC/DC
AC/DC are an Australian rock band formed in Sydney in 1973. Their music has been variously described as hard rock, blues rock and Heavy metal music, heavy metal, although the band calls it simply "rock and roll". They are cited as a formativ ...
, and
DC/DC conversion with
galvanic isolation
Galvanic isolation is a principle of isolating functional sections of electrical systems to prevent current flow; no direct conduction path is permitted.
Energy or information can still be exchanged between the sections by other means, suc ...
between the input and any outputs. The flyback converter is a
buck-boost converter with the
inductor
An inductor, also called a coil, choke, or reactor, is a Passivity (engineering), passive two-terminal electronic component, electrical component that stores energy in a magnetic field when an electric current flows through it. An inductor typic ...
split to form a
transformer
In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple Electrical network, circuits. A varying current in any coil of the transformer produces ...
, so that the voltage ratios are multiplied with an additional advantage of isolation.
Structure and principle
The schematic of a flyback converter is shown in Fig. 1. It is equivalent to that of a
buck–boost converter, with the inductor split to form a transformer. Therefore, the operating principle of both converters is very similar:
* When the switch is closed (top of Fig. 2), the primary of the transformer is directly connected to the input voltage source. The primary current and
magnetic flux
In physics, specifically electromagnetism, the magnetic flux through a surface is the surface integral of the normal component of the magnetic field B over that surface. It is usually denoted or . The SI unit of magnetic flux is the we ...
in the transformer increases, storing energy in the transformer. The voltage induced in the secondary winding is negative, so the
diode
A diode is a two-Terminal (electronics), terminal electronic component that conducts electric current primarily in One-way traffic, one direction (asymmetric electrical conductance, conductance). It has low (ideally zero) Electrical resistance ...
is
reverse-biased (i.e., blocked). The output
capacitor
In electrical engineering, a capacitor is a device that stores electrical energy by accumulating electric charges on two closely spaced surfaces that are insulated from each other. The capacitor was originally known as the condenser, a term st ...
supplies energy to the output load.
* When the switch is opened (bottom of Fig. 2), the primary current and magnetic flux drops. The secondary voltage is positive, forward-biasing the diode, allowing current to flow from the transformer. The energy from the transformer core recharges the capacitor and supplies the load.
The operation of storing energy in the transformer before transferring to the output of the converter allows the topology to easily generate multiple outputs with little additional circuitry, although the output voltages have to be able to match each other through the turns ratio. Also there is a need for a controlling rail which has to be loaded before load is applied to the uncontrolled rails, this is to allow the
pulse-width modulation
Pulse-width modulation (PWM), also known as pulse-duration modulation (PDM) or pulse-length modulation (PLM), is any method of representing a signal as a rectangular wave with a varying duty cycle (and for some methods also a varying peri ...
(PWM) to open up and supply enough energy to the transformer.
Operations
The flyback converter is an isolated power converter. The two prevailing control schemes are voltage mode control and current mode control. In the majority of cases current mode control needs to be dominant for stability during operation. Both modes require a signal related to the output voltage. There are three common ways to generate this voltage:
# Use an
optocoupler on the secondary circuitry to send a signal to the controller.
# Wind a separate winding on the core and rely on the cross regulation of the design.
# Sample the voltage amplitude on the primary side, during the discharge, referenced to the standing primary DC voltage.
The first technique, involving an optocoupler, has been used to obtain tight voltage and current regulation, whereas the second approach has been developed for cost-sensitive applications where the output does not need to be as tightly controlled, but many components including the optocoupler can be eliminated from the overall design. Also, in applications where reliability is critical, optocouplers can be detrimental to the system's
MTBF (Mean Time Between Failure). The third technique, primary-side sensing, can be as accurate as the first and more economical than the second, yet requires a minimum load so that the discharge-event keeps occurring, providing the opportunities to sample the 1:N secondary voltage at the primary winding (during T
discharge, as per Fig 3).
A variation in primary-side sensing technology is where the output voltage and current are regulated by monitoring the waveforms in the auxiliary winding used to power the control IC itself, which have improved the accuracy of both voltage and current regulation. The auxiliary primary winding is used in the same discharge phase as the remaining secondaries, but it builds a rectified voltage referenced commonly with the primary DC, hence considered on the primary side.
Previously, a measurement was taken across the whole of the flyback waveform which led to error, but it was realized that measurements at the so-called ''knee point'' (when the secondary current is zero, see Fig. 3) allow for a much more accurate measurement of the secondary side behavior. This topology is now replacing ringing choke converters (RCCs) in applications such as
mobile phone chargers.
Limitations
Continuous mode has the following disadvantages, which complicate the control of the converter:
* The voltage feedback loop requires a lower bandwidth due to a right half plane zero in the response of the converter.
* The current feedback loop used in current mode control needs slope compensation in cases where the
duty cycle
A duty cycle or power cycle is the fraction of one period in which a signal or system is active. Duty cycle is commonly expressed as a percentage or a ratio. A period is the time it takes for a signal to complete an on-and-off cycle. As a for ...
is above 50%.
* The power switches are now turning on with positive current flow - this means that in addition to turn-off speed, the switch turn-on speed is also important for efficiency and reducing
waste heat
Waste heat is heat that is produced by a machine, or other process that uses energy, as a byproduct of doing work. All such processes give off some waste heat as a fundamental result of the laws of thermodynamics. Waste heat has lower utility ...
in the switching element. Active Clamp Flyback
is a technology that alleviates this limitation.
Discontinuous mode has the following disadvantages, which limit the efficiency of the converter:
* High RMS and peak currents in the design
* High flux excursions in the inductor
Applications
* Low-power switch-mode power supplies (cell phone charger, standby power supply in PCs)
* Low-cost multiple-output power supplies (e.g., main PC supplies <250 W )'' The flyback converter is commonly used at the 50 to 100 W power range, as well as in high-voltage power supplies for televisions and computer monitors - Fundamentals of Power Electronics, Erickson & Maksimovic ''.
* High voltage supply for the
CRT in TVs and monitors (the flyback converter is often combined with the horizontal deflection drive)
* High voltage generation (e.g., for
xenon flash lamps, lasers, copiers, etc.)
* Isolated gate driver
See also
*
Forward converter
*
Joule thief - Minimalist switch-mode converter example
References
*
{{Reflist
DC-to-DC converters