HOME

TheInfoList



OR:

In flow chemistry, also called reactor engineering, a
chemical reaction A chemical reaction is a process that leads to the chemistry, chemical transformation of one set of chemical substances to another. When chemical reactions occur, the atoms are rearranged and the reaction is accompanied by an Gibbs free energy, ...
is run in a continuously flowing stream rather than in batch production. In other words, pumps move fluid into a reactor, and where tubes join one another, the fluids contact one another. If these fluids are reactive, a reaction takes place. Flow chemistry is a well-established technique for use at a large scale when
manufacturing Manufacturing is the creation or production of goods with the help of equipment, labor, machines, tools, and chemical or biological processing or formulation. It is the essence of the secondary sector of the economy. The term may refer ...
large quantities of a given material. However, the term has only been coined recently for its application on a
laboratory A laboratory (; ; colloquially lab) is a facility that provides controlled conditions in which scientific or technological research, experiments, and measurement may be performed. Laboratories are found in a variety of settings such as schools ...
scale by chemists and describes small pilot plants, and lab-scale continuous plants. Often, microreactors are used.


Batch vs. flow


Comparing parameter definitions in Batch vs Flow

*Reaction
stoichiometry Stoichiometry () is the relationships between the masses of reactants and Product (chemistry), products before, during, and following chemical reactions. Stoichiometry is based on the law of conservation of mass; the total mass of reactants must ...
: In batch production this is defined by the concentration of chemical reagents and their volumetric
ratio In mathematics, a ratio () shows how many times one number contains another. For example, if there are eight oranges and six lemons in a bowl of fruit, then the ratio of oranges to lemons is eight to six (that is, 8:6, which is equivalent to the ...
. In flow this is defined by the concentration of reagents and the ratio of their flow rate. *Residence time: In batch production this is determined by how long a vessel is held at a given temperature. In flow the volumetric residence time is given by the ratio of the volume of the reactor and the overall flow rate, as most often, plug flow reactors are used.


Running flow reactions

Choosing to run a
chemical reaction A chemical reaction is a process that leads to the chemistry, chemical transformation of one set of chemical substances to another. When chemical reactions occur, the atoms are rearranged and the reaction is accompanied by an Gibbs free energy, ...
using flow chemistry, either in a microreactor or other mixing device offers a variety of pros and cons.


Advantages

* Reaction temperature can be raised above the solvent's
boiling point The boiling point of a substance is the temperature at which the vapor pressure of a liquid equals the pressure surrounding the liquid and the liquid changes into a vapor. The boiling point of a liquid varies depending upon the surrounding envi ...
as the volume of the laboratory devices is typically small. Typically, non-compressible fluids are used with no gas volume so that the expansion factor as a function of
pressure Pressure (symbol: ''p'' or ''P'') is the force applied perpendicular to the surface of an object per unit area over which that force is distributed. Gauge pressure (also spelled ''gage'' pressure)The preferred spelling varies by country and eve ...
is small. * Mixing can be achieved within seconds at the smaller scales used in flow chemistry. * Heat transfer is intensified. Mostly, because the area to volume ratio is large. As a result, endothermic and exothermic reactions can be thermostated easily and consistently. The temperature gradient can be steep, allowing efficient control over reaction time. * Safety is increased: ** Thermal mass of the system is dominated by the apparatus making thermal runaways unlikely. ** Smaller reaction volume is also considered a safety benefit. ** The reactor operates under steady-state conditions. * Flow reactions can be automated with far less effort than batch reactions. This allows for unattended operation and experimental planning. By coupling the output of the reactor to a detector system, it is possible to go further and create an automated system which can sequentially investigate a range of possible reaction parameters (varying
stoichiometry Stoichiometry () is the relationships between the masses of reactants and Product (chemistry), products before, during, and following chemical reactions. Stoichiometry is based on the law of conservation of mass; the total mass of reactants must ...
, residence time and temperature) and therefore explore reaction parameters with little or no intervention. Typical drivers are higher yields/selectivities, less needed manpower, or a higher safety level. * Multi step reactions can be arranged in a continuous sequence. This can be especially beneficial if intermediate compounds are unstable, toxic, or sensitive to air since they will exist only momentarily and in very small quantities. * The position along the flowing stream and reaction time point are directly related to one another. This means that it is possible to arrange the system such that further reagents can be introduced into the flowing reaction stream at a precise time point that is desired. * It is possible to arrange a flowing system such that purification is coupled with the reaction. There are three primary techniques that are used: ** Solid phase scavenging ** Chromatographic separation ** Liquid/Liquid Extraction * Reactions that involve reagents containing dissolved gases are easily handled, whereas in batch a pressurized "bomb" reactor would be necessary. * Multi-phase liquid reactions (e.g. phase transfer catalysis) can be performed in a straightforward way, with high reproducibility over a range of scales and conditions. * Scale up of a proven reaction can be achieved rapidly with little or no process development work, by either changing the reactor volume or by running several reactors in parallel, provided that flows are recalculated to achieve the same residence times.


Disadvantages

* Dedicated equipment is needed for precise continuous dosing (e.g. pumps), connections, etc. * Start-up and shut-down procedures have to be established. * Scale-up of ''micro effects'' such as the high area to volume ratio is not possible and economy of scale may not apply. Typically, a scale-up leads to a dedicated plant. * Safety issues for the storage of reactive material still apply. The drawbacks have been discussed in view of establishing small scale continuous production processes by Pashkova and Greiner.


Continuous flow reactors

Continuous reactors are typically tube-like and manufactured from non-reactive materials such as stainless steel, glass, and polymers. Mixing methods include
diffusion Diffusion is the net movement of anything (for example, atoms, ions, molecules, energy) generally from a region of higher concentration to a region of lower concentration. Diffusion is driven by a gradient in Gibbs free energy or chemical p ...
alone (if the diameter of the reactor is small e.g. <1 mm, such as in microreactors) and static mixers. Continuous flow reactors allow good control over reaction conditions including heat transfer, time, and mixing. The residence time of the reagents in the reactor (i.e. the amount of time that the reaction is heated or cooled) is calculated from the volume of the reactor and the flow rate through it: :\text = \frac Therefore, to achieve a longer residence time, reagents can be pumped more slowly and/or a larger volume reactor used. Production rates can vary from nanoliters to liters per minute. Some examples of flow reactors are spinning disk reactors; spinning tube reactors; multi-cell flow reactors; oscillatory flow reactors; microreactors; hex reactors; and 'aspirator reactors'. In an aspirator reactor a pump propels one reagent, which causes a reactant to be sucked in. This type of reactor was patented around 1941 by the Nobel company for the production of nitroglycerin.


Flow reactor scale

The smaller scale of microflow reactors or microreactors can make them ideal for process development experiments. Although it is possible to operate flow processes at a ton scale, synthetic efficiency benefits from improved thermal and mass transfer as well as mass transport.


Key application areas


Use of gases in flow

Laboratory scale flow reactors are ideal systems for using gases, particularly those that are toxic or associated with other hazards. The gas reactions that have been most successfully adapted to flow are
hydrogenation Hydrogenation is a chemical reaction between molecular hydrogen (H2) and another compound or element, usually in the presence of a catalyst such as nickel, palladium or platinum. The process is commonly employed to redox, reduce or Saturated ...
and carbonylation, although work has also been performed using other gases, e.g. ethylene and
ozone Ozone () (or trioxygen) is an Inorganic compound, inorganic molecule with the chemical formula . It is a pale blue gas with a distinctively pungent smell. It is an allotrope of oxygen that is much less stable than the diatomic allotrope , break ...
. Reasons for the suitability of flow systems for hazardous gas handling are: *Systems allow the use of a fixed bed catalyst. Combined with low solution concentrations, this allows all compounds to be adsorbed to the catalyst in the presence of gas *Comparatively small amounts of gas are continually exhausted by the system, eliminating the need for many of the special precautions normally required for handling toxic and/or flammable gases *The addition of pressure means that a far greater proportion of the gas will be in solution during the reaction than is the case conventionally *The greatly enhanced mixing of the solid, liquid, and gaseous phases allows the researcher to exploit the kinetic benefits of elevated temperatures without being concerned about the gas being displaced from the solution


Photochemistry in combination with flow chemistry

Continuous flow photochemistry offers multiple advantages over batch photochemistry. Photochemical reactions are driven by the number of
photon A photon () is an elementary particle that is a quantum of the electromagnetic field, including electromagnetic radiation such as light and radio waves, and the force carrier for the electromagnetic force. Photons are massless particles that can ...
s that are able to activate molecules causing the desired reaction. The large surface area to volume ratio of a microreactor maximizes the illumination, and at the same time allows for efficient cooling, which decreases the thermal side products.


Electrochemistry in combination with flow chemistry

Continuous flow electrochemistry like continuous photochemistry offers many advantages over analogous batch conditions. Electrochemistry like Photochemical reactions can be considered as 'reagent-less' reactions. In an electrochemical reaction the reaction is facilitated by the number of electrons that are able to activate molecules causing the desired reaction. Continuous electrochemistry apparatus reduces the distance between the electrodes used to allow better control of the number of electrons transferred to the reaction media enabling better control and selectivity. Recent developments in electrochemical flow-systems enabled the combination of reaction-oriented electrochemical flow systems with species-focused spectroscopy which allows a complete analysis of reactions involving multiple electron transfer steps, as well as unstable intermediates. These systems which are referred to as spectroelectrochemistry systems can enable the use of UV-vis as well as more complex methods such as electrochemiluminescence. Furthermore, using electrochemistry allows another degree of flexibility since the user has control not only on the flow parameters and the nature of the electrochemical measurement itself but also on the geometry or nature of the electrode (or electrodes in the case of an electrode array).


Process development

The process development change from a serial approach to a parallel approach. In batch the chemist works first followed by the chemical engineer. In flow chemistry this changes to a parallel approach, where chemist and chemical engineer work interactively. Typically there is a plant setup in the lab, which is a tool for both. This setup can be either commercial or noncommercial. The development scale can be small (ml/hour) for idea verification using a chip system and in the range of a couple of liters per hour for scalable systems like the flow miniplant technology. Chip systems are mainly used for a liquid-liquid application while flow miniplant systems can deal with solids or viscous material.


Scale up of microwave reactions

Microwave reactors are frequently used for small-scale batch chemistry. However, due to the extremes of temperature and pressure reached in a microwave it is often difficult to transfer these reactions to conventional non-microwave apparatus for subsequent development, leading to difficulties with scaling studies. A flow reactor with suitable high-temperature ability and pressure control can directly and accurately mimic the conditions created in a microwave reactor. This eases the synthesis of larger quantities by extending reaction time.


Manufacturing scale solutions

Flow systems can be scaled to the tons per hour scale. Plant redesign (batch to conti for an existing plant), Unit Operation (exchanging only one reaction step) and Modular Multi-purpose (Cutting a continuous plant into modular units) are typical realization solutions for flow processes.


Other uses of flow

It is possible to run experiments in flow using more sophisticated techniques, such as solid phase chemistries. Solid phase reagents, catalysts or scavengers can be used in solution and pumped through glass columns, for example, the synthesis of alkaloid natural product oxomaritidine using solid phase chemistries. There is an increasing interest in polymerization as a continuous flow process. For example, Reversible Addition-Fragmentation chain Transfer or RAFT polymerization. Continuous flow techniques have also been used for the controlled generation of nanoparticles. The very rapid mixing and excellent temperature control of microreactors are able to give consistent and narrow particle size distribution of nanoparticles.


Segmented flow chemistry

As discussed above, running experiments in continuous flow systems is difficult, especially when one is developing new chemical reactions, which requires screening of multiple components, varying stoichiometry, temperature, and residence time. In continuous flow, experiments are performed serially, which means one experimental condition can be tested. Experimental throughput is highly variable and as typically five times the residence time is needed for obtaining steady state. For temperature variation the thermal mass of the reactor as well as peripherals such as fluid baths needs to be considered. More often than not, the analysis time needs to be considered. Segmented flow is an approach that improves upon the speed in which screening, optimization, and libraries can be conducted in flow chemistry. Segmented flow uses a " Plug Flow" approach where specific volumetric experimental mixtures are created and then injected into a high-pressure flow reactor. Diffusion of the segment (reaction mixture) is minimized by using immiscible solvent on the leading and rear ends of the segment. One of the primary benefits of segmented flow chemistry is the ability to run experiments in a serial/parallel manner where experiments that share the same residence time and temperature can be repeatedly created and injected. In addition, the volume of each experiment is independent of that of the volume of the flow tube thereby saving a significant amount of reactant per experiment. When performing reaction screening and libraries, segment composition is typically varied by the composition of matter. When performing reaction optimization, segments vary by stoichiometry. Segmented flow is also used with online LCMS, both analytical and preparative where the segments are detected when exiting the reactor using UV and subsequently diluted for analytical LCMS or injected directly for preparative LCMS.


See also

*
Chemical reaction A chemical reaction is a process that leads to the chemistry, chemical transformation of one set of chemical substances to another. When chemical reactions occur, the atoms are rearranged and the reaction is accompanied by an Gibbs free energy, ...
* Microfluidics * Microreactor *
Organic chemistry Organic chemistry is a subdiscipline within chemistry involving the science, scientific study of the structure, properties, and reactions of organic compounds and organic matter, organic materials, i.e., matter in its various forms that contain ...
* Plug flow reactor


References

{{reflist


External links


ReelReactor Continuous Chemical and Biological Reactor

Continuous flow multi-step organic synthesis
-
Chemical Science
Mini Review by Damien Webb and Timothy F. Jamison discussing the current state of the art and highlighting recent progress and current challenges facing the emerging area of continuous flow techniques for multi-step synthesis. Published by the
Royal Society of Chemistry The Royal Society of Chemistry (RSC) is a learned society and professional association in the United Kingdom with the goal of "advancing the chemistry, chemical sciences". It was formed in 1980 from the amalgamation of the Chemical Society, the ...

Continuous flow reactors: a perspective
Review by Paul Watts and Charlotte Wiles. Published by the
Royal Society of Chemistry The Royal Society of Chemistry (RSC) is a learned society and professional association in the United Kingdom with the goal of "advancing the chemistry, chemical sciences". It was formed in 1980 from the amalgamation of the Chemical Society, the ...

Flow Chemistry: Continuous Synthesis and Purification of Pharmaceuticals and Fine Chemicals
Short Course offered at MIT by Professors Timothy Jamison and Klavs Jensen] Industrial processes Chemical engineering Microfluidics