In general, the term design load can refer to two distinct concepts:
# the maximum amount a system is designed to handle, or
# the maximum amount the system is capable of producing.
These interpretations represent fundamentally different aspects of system performance. The design load is either the same as or a multiple of the rated load, which represents the system's declared performance capacity, see
structural design load section below.
Structures and
pressure vessels
A pressure vessel is a container designed to hold gases or liquids at a pressure substantially different from the ambient pressure.
Construction methods and materials may be chosen to suit the pressure application, and will depend on the size o ...
have design loads of the first type.
Electric motors
An electric motor is a machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and electric current in a wire winding to generate Laplace force i ...
,
compressors and
heaters have design loads of the second type.
Cranes have design loads of both the first and second type because they have to lift a defined load and do that at a specified speed.
Example crane design load
A
crane's rated load is its
Safe Working Load (SWL) and the design load (DL) is, (p 90)
The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than
.(p 84)
Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than,
The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope required on this size of crane is, (p 68)
Thus the MBL is 2.3 times of the DL and ~3 times that of the SWL for this example. Similar ratios are obtained for other parts of the crane's structure. This
factor of safety has been shown to be required when a failure could be catastrophic, such as a crane dropping its load or collapsing entirely. The dynamic lift factor increases as the SWL of a crane decreases and its exact value is dependent on the hoisting speed of the crane and other factors. These calculations are more complex and beyond the scope of this article.
Structural design load
In
structural design, the design load depends on the calculation method used. There are two widely accepted methods,
Allowable Strength Design (ASD) and
Load Resistance Factor Design (LRFD). In general terms, the engineer uses unfactored
structural loads and the material yield strength with a
safety factor
In engineering, a factor of safety (FoS) or safety factor (SF) expresses how much stronger a system is than it needs to be for its specified maximum load. Safety factors are often calculated using detailed analysis because comprehensive testing i ...
in ASD; while in LRFD both structural loads and strength are factored and the strength is the ultimate rather than the yield.
[http://www.lightingandsoundamerica.com/mailing/Protocol/PSummer2018_StressDesign.pdf] For example, a bridge would have a specified load carrying capacity, with the design load being determined according to the calculation method used and applied in the calculations to ensure the actual real-world capacity of the bridge to carry specified load.
See also
*
Limit states design
*
Factor of safety
*
Specified load
References