A density meter (densimeter) is a device which measures the
density Density (volumetric mass density or specific mass) is the ratio of a substance's mass to its volume. The symbol most often used for density is ''ρ'' (the lower case Greek letter rho), although the Latin letter ''D'' (or ''d'') can also be u ...
of an object or material. Density is usually abbreviated as either \rho or D . Typically, density either has the units of '' kg/m^3 '' or '' lb/ft^3 ''. The most basic principle of how density is calculated is by the formula: : \rho = \frac Where: : \rho = the density of the sample. : m = the mass of the sample. : V = the volume of the sample. Many density meters can measure both the wet portion and the dry portion of a sample. The wet portion comprises the density from all liquids present in the sample. The dry solids comprise solely of the density of the solids present in the sample. A density meter does not measure the
specific gravity Relative density, also called specific gravity, is a dimensionless quantity defined as the ratio of the density (mass of a unit volume) of a substance to the density of a given reference material. Specific gravity for solids and liquids is nea ...
of a sample directly. However, the specific gravity can be inferred from a density meter. The specific gravity is defined as the density of a sample compared to the density of a reference. The reference density is typically of that of water. The specific gravity is found by the following equation: : SG_s = \frac Where: : SG_s = the specific gravity of the sample. : \rho_s = the density of the sample that needs to be measured. : \rho_r = the density of the reference material (usually water). Density meters come in many varieties. Different types include:
nuclear Nuclear may refer to: Physics Relating to the nucleus of the atom: *Nuclear engineering *Nuclear physics *Nuclear power *Nuclear reactor *Nuclear weapon *Nuclear medicine *Radiation therapy *Nuclear warfare Mathematics * Nuclear space *Nuclear ...
,
coriolis Coriolis may refer to: * Gaspard-Gustave de Coriolis (1792–1843), French mathematician, mechanical engineer and scientist * Coriolis force In physics, the Coriolis force is a pseudo force that acts on objects in motion within a frame of ref ...
, ultrasound, microwave, and gravitic. Each type measures the density differently. Each type has its advantages and drawbacks. Density meters have many applications in various parts of various industries. Density meters are used to measure
slurries A slurry is a mixture of denser solids suspended in liquid, usually water. The most common use of slurry is as a means of transporting solids or separating minerals, the liquid being a carrier that is pumped on a device such as a centrifugal p ...
, sludges, and other liquids that flow through the pipeline. Industries such as
mining Mining is the Resource extraction, extraction of valuable geological materials and minerals from the surface of the Earth. Mining is required to obtain most materials that cannot be grown through agriculture, agricultural processes, or feasib ...
,
dredging Dredging is the excavation of material from a water environment. Possible reasons for dredging include improving existing water features; reshaping land and water features to alter drainage, navigability, and commercial use; constructing d ...
,
wastewater treatment Wastewater treatment is a process which removes and eliminates contaminants from wastewater. It thus converts it into an effluent that can be returned to the water cycle. Once back in the water cycle, the effluent creates an acceptable impact on ...
, paper, oil, and gas all have uses for density meters at various points during their respective processes.


Different types of density meter


Coriolis

Coriolis density meters, also known as ''mass flow meters'' or ''inertial flow meters'', work on the principle of vibration to measure phase shifts in the vibration of a bent thin walled tube. The bent thin walled tube is rotated around a central axis. When there is no mass in the bent section, the tube remains untwisted. However, when the density inside the bent section increases, the inbound flow portion of the bent pipe drags behind the out flow portion. This twisting causes phase shifts which result in changes in the resonant frequency of the thin walled tube. Therefore, the resonant frequency is directly affected by the density. Higher density media causes a larger
Coriolis effect In physics, the Coriolis force is a pseudo force that acts on objects in motion within a frame of reference that rotates with respect to an inertial frame. In a reference frame with clockwise rotation, the force acts to the left of the moti ...
if the volumetric flow rate is constant. Flowing media causes a frequency and a phase shift of the bent pipe, which are proportional to the
mass flow rate In physics and engineering, mass flow rate is the Temporal rate, rate at which mass of a substance changes over time. Its unit of measurement, unit is kilogram per second (kg/s) in SI units, and Slug (unit), slug per second or pound (mass), pou ...
of the sample. Coriolis meters measure the mass flow of the system. They do not measure the volumetric flow. However, a volumetric flow can be inferred from the mass
flow measurement Flow measurement is the quantification of bulk fluid movement. Flow can be measured using devices called flowmeters in various ways. The common types of flowmeters with industrial applications are listed below: * Obstruction type (differential pr ...
. These measurements are restricted to small diameters for flow tubes. However, this measurement technique results in high accuracy and high repeatability. Coriolis meters also have a fast response time. Coriolis meters need to be calibrated for temperature and pressure. The zero points for these values are used to calibrate the system. Coriolis meters cannot be calibrated while in use. The span difference is used to see how temperature and pressure have changed.


Nuclear

Nuclear density meters work on the principle of measuring gamma radiation. Gamma radiation is emitted from a source. This source is typically
caesium-137 Caesium-137 (), cesium-137 (US), or radiocaesium, is a radioactive isotope of caesium that is formed as one of the more common fission products by the nuclear fission of uranium-235 and other fissionable isotopes in nuclear reactors and nucle ...
(half-life: ~30 years). The radiation is seen by a scintillator device. The radiation is converted into flashes of light. The number of flashes of light is counted. Radiation that is absorbed by the mass is not seen by the scintillator device. Therefore, the density of the media is inversely proportional to the radiation captured and seen by the scintillator. Nuclear density meters are limited in scope to what is seen by the gamma radiation beam. The sample size is a single, thin column with small longitudinal length. Nuclear equipment requires certified and licensed staff in order to operate the instruments.


Microwave

Microwave density meters have various ways to measure what solids are in the sample. All microwave meters measure microwaves but some use different methods such as measuring the microwave propagation speed change, amplitude reduction, time of flight, single phase difference, or dual phase shift. Each technique has certain accuracies. Some microwave meters use a ceramic probe that is directly inserted into the sample. This allows the meter to have direct contact to the sample in question. However, this limits the types of slurries and sludges that can flow through the pipe line. Abrasive slurries with particulates can damage the sensor probe. Microwave meters are also limited to liquids with unvarying dielectric constants. The percentage of solids of the slurry affects the dielectric constant for the entire sample. Typically, percent solids greater than 20% result in large errors. Similar inconsistencies happen with large pipe diameters. Microwave meters are very good at detecting dissolved solids. Homogeneous solutions are easily seen by microwave meters. This makes them a fit for applications where the solution is consistent and non-abrasive.


Ultrasonic

Ultrasonic density meters work on various principles to calculate the density. One of the methods is the transit-time principle (also known as the time of flight principle). With this technique, a sensor is typically installed in the pipe, which has an ultrasonic transmitter and an ultrasonic receiver in one construction. The ultrasonic density meter calculates the sonic velocity by using the known distance between the transmitter and receiver and the measured transit time. The
measuring instrument Instrumentation is a collective term for measuring instruments, used for indicating, measuring, and recording physical quantities. It is also a field of study about the art and science about making measurement instruments, involving the related ...
can now calculate the density, as it is dependent on the sound velocity. Another method that is utilized in ultrasonic meters is the envelope energy average method. This method is based on not only the amplitude of the signal but also the shape of the signal. These packets of information are called envelopes. Doppler ultrasonic meters measure the suspension flow where the concentration of solids in the slurry is above 100ppm and the particles that are suspended are larger than 100 microns in diameter. However, the Doppler method only works on concentrations of less than 10% solids.


Compensations


Temperature

Temperature Temperature is a physical quantity that quantitatively expresses the attribute of hotness or coldness. Temperature is measurement, measured with a thermometer. It reflects the average kinetic energy of the vibrating and colliding atoms making ...
affects the density of fluids. In most cases, an increase in temperature indicates that the density of the media will decrease. This indicates that temperature and density are inversely proportional to each other. Temperature also affects the meters themselves. Mass flow meters have different resonant frequencies at different temperatures.


Pressure

Pressure Pressure (symbol: ''p'' or ''P'') is the force applied perpendicular to the surface of an object per unit area over which that force is distributed. Gauge pressure (also spelled ''gage'' pressure)The preferred spelling varies by country and eve ...
changes the rigidity of the mass flow tube. Pressure affects the rigidity of gravimetric meters.


Vibration

Vibration from plant noise can be filtered out. Vibration is apparent in microwave, ultrasonic, gravimetric, and Coriolis meters. Vibration causes these types of meters to accumulate error


Damage

Coriolis meters have compensations from pitting, cracking, coating, erosion, and corrosion. These damages affect the way that the tube resonates. These changes affect the baseline. Compensations cannot be made dynamically. These damages typically cause offsets that can be added to the existing calibration factors that will ensure that a consistent reading is still acquired.