History
The use of cold-formed steel members in building construction began in the 1850s in both the United States and Great Britain. In the 1920s and 1930s, acceptance of cold-formed steel as a construction material was still limited because there was no adequate design standard and limited information on material use in building codes. One of the first documented uses of cold-formed steel as a building material is the Virginia Baptist Hospital, constructed around 1925 in Lynchburg, Virginia. The walls were load bearing masonry, but the floor system was framed with double back-to-back cold-formed steel lipped channels. According to Chuck Greene, P.E., of Nolen Frisa Associates, the joists were adequate to carry the initial loads and spans, based on current analysis techniques. Greene engineered a recent renovation to the structure and said that for the most part, the joists are still performing well. A site observation during this renovation confirmed that "these joists from the 'roaring twenties' are still supporting loads, over 80 years later!" In the 1940s, Lustron Homes built and sold almost 2500 steel-framed homes, with the framing, finishes, cabinets and furniture made from cold-formed steel.History of AISI design standards
Design standards for hot-rolled steel (seeInternational codes and standards
The United States, Mexico and Canada use the North American Specification for the Design of Cold-Formed Steel Structural Members, document number AISI S100-2007. Member states of the European Union use section 1-3 of the Eurocode 3 (EN 1993) for the design of cold formed steel members. Other nations utilize various design specifications, many based on AISI S-100, as adopted by the building codes listed below. Another list of international cold-formed steel codes and standards is maintained (and can be edited with permission) aAfrica
Ethiopia Building Codes: EBCS-1 Basis of design and actions on structures EBCS-3 Design of steel structuresAmericas
United States Specification: North American Specification for the Design of Cold-Formed Steel Structural Members, document number AISI S100-2007 published by the American Iron and Steel Institute in October 2007. Building Code: International Building Code, IBC and/or NFPA may be enforced, but both reference AISI S100. Canada Specification: North American Specification for the Design of Cold-Formed Steel Structural Members, document number CAN/CSA S136-07 as published bAsia
Philippines National Structural Code of the Philippines 2010, Volume 1 Buildings, Towers, and other Vertical Structures, Chapter 5 Part 3 Design of Cold-Formed Steel Structural Members is based on AISI S100-2007 India Specification: IS:801 and IS:811, Indian standard code of practice for use of cold-formed light gauge steel structural members in general building construction, Bureau of Indian Standards, New Delhi (1975). (currently under revision) Building Code : see - model codEurope
EU Countries Specification: EN 1993-1-3 (same as Eurocode 3 part 1-3), Design of steel structures - Cold formed thin gauge members and sheeting. Each European country will get its own National Annex Documents (NAD). Germany Specification: German Committee for Steel Structures (DASt), DASt-Guidelines 016: 1992: Calculation and design of structures with thin-walled cold-formed members; In German Building Code: EN 1993-1-3: 2006 (Eurocode 3 Part 1-3): Design of steel structures – General rules – Supplementary rules for cold-formed members and sheeting; German version prEN 1090 2: 2005 (prEN 1090 Part 2; Draft): Execution of steel structures and aluminium structures – Technical requirements for the execution of steel structures; German version EN 10162: 2003: Cold-rolled steel sections – Technical delivery conditions – Dimensional and cross-sectional tolerances; German version Italy Specification: UNI CNR 10022 (National Document) EN 1993-1-3 (Not compulsory) United Kingdom Eurocode for cold-formed steel in the UK. BS EN 1993-1-3:2006: Eurocode 3. Design of steel structures. General rules.Oceania
Australia Specification: AS/NZS 4600 AS/NZS 4600:2005 Similar to NAS 2007 but includes high strength steels such as G550 for all sections. (Greg Hancock) Building Code: Building Code of Australia (National document) calls AS/NZS 4600:2005 New Zealand Specification: AS/NZS 4600 (same as Australia)Common section profiles and applications
In building construction there are basically two types of structural steel: hot-rolled steel shapes and cold-formed steel shapes. The hot rolled steel shapes are formed at elevated temperatures while the cold-formed steel shapes are formed at room temperature. Cold-formed steel structural members are shapes commonly manufactured from steel plate, sheet metal or strip material. The manufacturing process involves forming the material by either press-braking or cold roll forming to achieve the desired shape. When steel is formed by press-braking or cold rolled forming, there is a change in the mechanical properties of the material by virtue of the cold working of the metal. When a steel section is cold-formed from flat sheet or strip the yield strength, and to a lesser extent the ultimate strength, are increased as a result of this cold working, particularly in the bends of the section. Some of the main properties of cold formed steel are as follows: *Lightness in weight *High strength and stiffness *Ease of prefabrication and mass production *Fast and easy erection and installation *Substantial elimination of delays due to weather *More accurate detailing *Non shrinking and non creeping at ambient temperatures *Formwork is not needed *Termite-proof and rot proof *Uniform quality *Economy in transportation and handling *Non-combustibile *Recyclable material *Panels and decks can provide enclosed cells for conduits. ---- A broad classification of the cold-formed shapes used in the construction industry can be made as individual structural framing members or panels and decks. Some of the popular applications and the preferred sections are: *Roof and wall systems (industrial, commercial, and agricultural buildings) *Steel racks for supporting storage pallets *Structural members for plane and space trusses *Frameless Stressed skin structures: Corrugated sheets or sheeting profiles with stiffened edges are used for small structures up to a 30 ft clear span with no interior frameworkTypical stress–strain properties
A main property of steel, which is used to describe its behavior, is the stress–strain graph. The stress–strain graphs of cold-formed steel sheet mainly fall into two categories. They are sharp yielding and gradual yielding type illustrated below in Fig.1 and Fig.2, respectively. These two stress–strain curves are typical for cold-formed steel sheet during tension test. The second graph is the representation of the steel sheet that has undergone the cold-reducing (hard rolling) during manufacturing process, therefore it does not exhibit a yield point with a yield plateau. The initial slope of the curve may be lowered as a result of the prework. Unlike Fig.1, the stress–strain relationship in Fig.2 represents the behavior of annealed steel sheet. For this type of steel, the yield point is defined by the level at which the stress–strain curve becomes horizontal. Cold forming has the effect of increasing the yield strength of steel, the increase being the consequence of cold working well into the strain-hardening range. This increase is in the zones where the material is deformed by bending or working. The yield stress can be assumed to have been increased by 15% or more for design purposes. The yield stress value of cold-formed steel is usually between 33ksi and 80ksi. The measured values of modulus of elasticity based on the standard methods usually range from 29,000 to 30,000 ksi (200 to 207 GPa). A value of 29,500 ksi (203 GPa) is recommended by AISI in its specification for design purposes. The ultimate tensile strength of steel sheets in the sections has little direct relationship to the design of those members. The load-carrying capacities of cold-formed steel flexural and compression members are usually limited by yield point or buckling stresses that are less than the yield point of steel, particularly for those compression elements having relatively large flat-width ratios and for compression members having relatively large slenderness ratios. The exceptions are bolted and welded connections, the strength of which depends not only on the yield point but also on the ultimate tensile strength of the material. Studies indicate that the effects of cold work on formed steel members depend largely upon the spread between the tensile and the yield strength of the virgin material.Ductility criteria
Weldability
Weldability refers to the capacity of steel to be welded into a satisfactory, crack free, sound joint under fabrication conditions without difficulty.Minimum material thickness recommended for welding connections
Application in buildings
Cold-formed steel framing
Cold-formed steel framing (CFSF) refers specifically to members in light-frame building construction that are made entirely of sheet steel, formed to various shapes at ambient temperatures. The most common shape for CFSF members is a lipped channel, although "Z", "C", tubular, "hat" and other shapes and variations have been used. The building elements that are most often framed with cold-formed steel are floors, roofs, and walls, although other building elements and both structural and decorative assemblies may be steel framed. Although cold-formed steel is used for several products in building construction, framing products are different in that they are typically used for wall studs, floor joists, rafters, and truss members. Examples of cold-formed steel that would not be considered framing includes metal roofing, roof and floor deck, composite deck, metal siding, and purlins and girts on metal buildings. Framing members are typically spaced at 16 or 24 inches on center, with spacing variations lower and higher depending upon the loads and coverings. Wall members are typically vertical lipped channel "stud" members, which fit into unlipped channel "track" sections at the top and bottom. Similar configurations are used for both floor joist and rafter assemblies, but in a horizontal application for floors, and a horizontal or sloped application for roof framing. Additional elements of the framing system include fasteners and connectors, braces and bracing, clips and connectors. In North America, member types have been divided into five major categories, and product nomenclature is based on those categories. * S members are lipped channels, most often used for wall studs, floor joists, and ceiling or roof rafters. * T members are unlipped channels, which are used for top and bottom plates (tracks) in walls, and rim joists in floor systems. Tracks also form the heads and sills of windows, and typically cap the top and bottom of boxed- or back-to-back headers. * U members are unlipped channels that have a smaller depth than tracks, but are used to brace members, as well as for ceiling support systems. * F members are "furring" or "hat" channels, typically used horizontally on walls or ceilings. * L members are angles, which in some cases can be used for headers across openings, to distribute loads to the adjacent jamb studs. In high-rise commercial and multi-family residential construction, CFSF is typically used for interior partitions and support of exterior walls and cladding. In many mid-rise and low-rise applications, the entire structural system can be framed with CFSF. Cold Rolled Steel Buildings are manufactured from pre-galvanised steel coil. With this, it means getting all components of a Cold Rolled frame and a galvanised finish with no need for additional coating or painting.Connectors and fasteners in framing
Connectors are used in cold-formed steel construction to attach members (i.e. studs, joists) to each other or to the primary structure for the purpose of load transfer and support. Since an assembly is only as strong as its weakest component, it is important to engineer each connection so that it meets specified performance requirements. There are two main connection types, Fixed and Movement-Allowing (Slip). Fixed connections of framing members do not allow movement of the connected parts. They can be found in axial-load bearing walls, curtain walls, trusses, roofs, and floors. Movement-Allowing connections are designed to allow deflection of the primary structure in the vertical direction due to live load, or in the horizontal direction due to wind or seismic loads, or both vertical and horizontal directions. One application for a vertical movement-allowing connection is to isolate non-axial load bearing walls (drywall) from the vertical live load of the structure and to prevent damage to finishes. A common clip for this application is an L-shaped top-of-wall clip for walls that are infill between floors. These clips have slots perpendicular to the bend in the clip. Another common clip is the bypass clip for walls that bypass outside the edge of the floor structure. When these clips are L-shaped, they have slots that are parallel to the bend in the clip. If the structure is in an activeHot-rolled versus cold-rolled steel and the influence of annealing
Annealing, also described in the earlier section, is part of the manufacturing process of cold-formed steel sheet. It is aAlternative design methods
The Direct Strength Method (DSM) is an alternative method of design located in Appendix 1 of the ''North American Specification for the Design of Cold-formed Steel Structural Members'' 2007 (AISI S100-07). DSM may be used in lieu of the Main Specification for determining nominal member capacities. Specific advantages include the absence of effective width and iterations, while only using known gross-sectional properties. An increase in prediction confidence stems from forced compatibility between section flanges and web throughout elastic buckling analysis. This increase in prediction accuracy for any section geometry provides a solid basis for rational analysis extension and encourages cross-sectional optimization. Either DSM or the main specification can be used with confidence as the Φ or Ω factors have been designed to insure that both methods are accurate. Currently, DSM only provides solutions for beams and columns and has to be used in conjunction with the main specification for a complete design. Rational analysis is permitted when using optimized cold form shapes that are outside of the scope of the main specification and are not pre-qualified for DSM use. These non-pre-qualified sections use the factors of safety of Φ and Ω associated with rational analysis (see AISI 2001 Section A1.1 (b)). The result of the rational analysis times the appropriate factor of safety will be used as the design strength of the section. Several situations may exist where a rational analysis application of DSM can be used. In general these would include: (1) determining the elastic buckling values and (2) using the DSM equations in Appendix 1 to determine nominal flexural and axial capacities, Mn and Pn. The premise of DSM itself is an example of rational analysis. It uses elastic buckling results to determine the ultimate strength through the use of empirical strength curves. This provides designers with a method for performing a rational analysis in a number of unique situations. In some cases the rational analysis extension to DSM may be as simple as dealing with an observed buckling mode that is difficult to identify and making a judgment call as to how to categorize the mode. But it could also be used to allow an engineer to include the effects of moment gradients, the influence of different end conditions, or the influence of torsion warping on all buckling modes. There are currently no provisions within the DSM that pertain to shear, web crippling, holes in members, or strength increases due to the cold work of forming. Research on several of these topics has been completed or is in the process of being completed and should be included in the next update of the AISI Specification. DSM is also limited in determining strength for sections in which very slender elements are used. This is due to the strength of a cross section being predicted as a whole with DSM instead of using the effective width method of the specification which breaks the cross section up into several effective elements. One slender element will cause low strength with DSM, which is not the case with the current specification method. The finite strip method using CUFSM is the most commonly used approach to determine the elastic buckling loads. The program also limits DSM because holes cannot be considered, loads have to be uniform along the member, only simply supported boundary conditions are considered, and the buckling modes interact and cannot be easily distinguishable in some cases.References
External links
Organizations
* American Iron and Steel Institute (AISI