HOME

TheInfoList



OR:

A carbon monoxide detector or CO detector is a device that detects the presence of the
carbon monoxide Carbon monoxide (chemical formula CO) is a poisonous, flammable gas that is colorless, odorless, tasteless, and slightly less dense than air. Carbon monoxide consists of one carbon atom and one oxygen atom connected by a triple bond. It is the si ...
(CO) gas to prevent
carbon monoxide poisoning Carbon monoxide poisoning typically occurs from breathing in carbon monoxide (CO) at excessive levels. Symptoms are often described as " flu-like" and commonly include headache, dizziness, weakness, vomiting, chest pain, and confusion. Large ...
. In the late 1990s,
Underwriters Laboratories The UL enterprise is a global private safety company headquartered in Northbrook, Illinois, composed of three organizations, UL Research Institutes, UL Standards & Engagement and UL Solutions. Established in 1894, the UL enterprise was founded a ...
changed the definition of a single station CO detector with a sound device to carbon monoxide (CO) alarm. This applies to all CO safety alarms that meet UL 2034 standard; however for passive indicators and system devices that meet UL 2075, UL refers to these as ''carbon monoxide detectors''. Most CO detectors use a sensor with a defined, limited lifespan, and will not work indefinitely. CO is a colorless, tasteless, and odorless gas produced by incomplete combustion of carbon-containing materials. It is often referred to as the "silent killer" because it is virtually undetectable by humans. In a study by Underwriters Laboratories, "Sixty percent of Americans could not identify any potential signs of a CO leak in the home". Elevated levels of CO can be dangerous to humans depending on the amount present and length of exposure. Smaller concentrations can be harmful over longer periods while increasing concentrations require diminishing exposure times to be harmful. Those living in all-electric homes don’t need CO detectors unless there is an attached garage with a non-electric car, or if a backup generator is used too close to your living quarters during a power outage. CO detectors are designed to measure CO levels over time and sound an alarm before dangerous levels of CO accumulate in an environment, giving people adequate warning to safely ventilate the area or evacuate. Some system-connected detectors also alert a monitoring service that can dispatch emergency services if necessary. While CO detectors do not serve as smoke detectors and vice versa, combined smoke/CO detectors are also sold. In the home, some common sources of CO include open flames, space heaters, water heaters, blocked chimneys or running a car or grill inside a garage.


Installation

The devices can either be battery-operated or AC-powered (with or without a battery backup). Battery-powered devices advertise a battery lifetime of up to 10 years. The gas sensors in CO alarms have a limited life span, typically two to five years. Newer models are designed to signal a need to be replaced after a set period. CO detectors all have "test" buttons like smoke detectors, but the test buttons only test the battery, electronic circuit, and buzzer, not the alarm’s ability to sense gas. According to the carbon monoxide guidelines of the
National Fire Protection Association The National Fire Protection Association (NFPA) is a U.S.-based international nonprofit organization devoted to eliminating death, injury, property damage, and economic loss due to fire, electrical, and related hazards. , the NFPA claims to have 5 ...
, CO detectors should be installed in each sleeping area in a dwelling, and each detector should be located "on the wall, ceiling or other location as specified in the installation instructions that accompany the unit". CO detectors are available as stand-alone models, or system-connected devices which can be monitored remotely.


Function

The primary purpose of CO detectors is to sound an alarm to warn occupants of an enclosed space of a dangerous level of carbon monoxide. The alarm should sound within 60 minutes if the concentration rises to 70 PPM, within 10 minutes at 150 PPM, in 4 minutes at 400 PPM, and immediately at 500 PPM or greater. The alarm should not sound too quickly, as brief false alarms may prompt users to disable the alarm, leaving them unprotected. Some alarm devices may display the CO level. There are also measuring instruments designed to display CO concentrations down to low, non-dangerous levels, rather than detect and warn of dangerous levels. Some detectors without UL certification have been found not to sound at the specified threshold, or to sound within seconds. In some instances, it's worth noting that a red flashing without accompanying sounds could indicate a different condition or simply inform the user about a malfunction. Wireless home safety devices are available that link carbon monoxide detectors to vibrating pillow pads, strobes, or a remote warning handset. Several carbon monoxide detection methods are used and documented in industry specifications published by
Underwriters Laboratories The UL enterprise is a global private safety company headquartered in Northbrook, Illinois, composed of three organizations, UL Research Institutes, UL Standards & Engagement and UL Solutions. Established in 1894, the UL enterprise was founded a ...
. Alerting methods include: * Audible tones (4 short beeps) ** Varies between 3,000 and 3,500 Hz depending on brand and model name ** 105 dB loudness at 3 feet * Spoken voice alert * Emergency light for illumination


Sensors

Early designs used a chemical detector consisting of a white pad that faded to a brownish or blackish color in the presence of carbon monoxide. Such detectors are cheap but only give a visual warning. As carbon monoxide-related deaths increased during the 1990s, audible alarms became standard. The alarm points on carbon monoxide detectors are not a simple alarm level (as in smoke detectors) but are a concentration-time function. At lower concentrations, e.g. 100 parts per million (PPM), the detector does not sound an alarm for many tens of minutes. At 400 PPM, the alarm sounds within a few minutes. This concentration-time function is intended to mimic the uptake of carbon monoxide in the body while also preventing false alarms due to brief bursts of carbon monoxide from relatively common sources such as cigarette smoke. Four types of sensors are available, varying in cost, accuracy, and speed of response. Most detectors do not have replaceable sensors.


Opto-chemical type

The detector consists of a pad of a colored chemical which changes color upon reaction with carbon monoxide. They only provide a qualitative warning of the gas, however. The main advantage of these detectors is that they are the lowest cost, but the downside is that they also offer the lowest level of protection. One reaction used for carbon monoxide detection is potassium disulfitopalladate (II) catalytic oxidation: :CO + K2Pd(SO3)2 -> Pd + CO2 + SO2 + K2SO3 As the reaction progresses, the release of
palladium Palladium is a chemical element; it has symbol Pd and atomic number 46. It is a rare and lustrous silvery-white metal discovered in 1802 by the English chemist William Hyde Wollaston. He named it after the asteroid Pallas (formally 2 Pallas), ...
causes the color to change from yellow to brown to black.


Biomimetic type

A biomimetic sensor works in a fashion similar to hemoglobin which darkens in the presence of CO proportional to the amount of carbon monoxide in the surrounding environment. It uses
cyclodextrin Cyclodextrins are a family of cyclic oligosaccharides, consisting of a macrocycle, macrocyclic ring of glucose subunits joined by α-1,4 glycosidic bonds. Cyclodextrins are produced from starch by enzyme, enzymatic conversion. They are used in ...
s, a
chromophore A chromophore is the part of a molecule responsible for its color. The word is derived . The color that is seen by our eyes is that of the light not Absorption (electromagnetic radiation), absorbed by the reflecting object within a certain wavele ...
, and a number of metal
salt In common usage, salt is a mineral composed primarily of sodium chloride (NaCl). When used in food, especially in granulated form, it is more formally called table salt. In the form of a natural crystalline mineral, salt is also known as r ...
s. This can either be seen directly or connected to an
infrared Infrared (IR; sometimes called infrared light) is electromagnetic radiation (EMR) with wavelengths longer than that of visible light but shorter than microwaves. The infrared spectral band begins with the waves that are just longer than those ...
source of photons such as an IR
LED A light-emitting diode (LED) is a semiconductor device that emits light when current flows through it. Electrons in the semiconductor recombine with electron holes, releasing energy in the form of photons. The color of the light (corresp ...
and then monitored using a
photodiode A photodiode is a semiconductor diode sensitive to photon radiation, such as visible light, infrared or ultraviolet radiation, X-rays and gamma rays. It produces an electrical current when it absorbs photons. This can be used for detection and me ...
. Battery lifespan is usually two to three years with conventional alkaline, but a lithium battery will last the life of the product. The biotechnology-based sensors have a useful operational life of six years. These products were the first to enter the mass market, but because they cost more than other sensors they are mostly used in higher-end areas and RVs. The technology has been improved and is the most reliable technology, according to a report from Lawrence Berkeley National Laboratory.


Electrochemical type

The electrochemical detector uses the principle of a
fuel cell A fuel cell is an electrochemical cell that converts the chemical energy of a fuel (often hydrogen fuel, hydrogen) and an oxidizing agent (often oxygen) into electricity through a pair of redox reactions. Fuel cells are different from most bat ...
to generate an electrical current when the gas to be detected undergoes a chemical reaction. The generated current is precisely related to the amount of carbon monoxide in the immediate environment close to the sensor. Essentially, the electrochemical cell consists of a container, two electrodes, connection wires, and an electrolyte, typically
sulfuric acid Sulfuric acid (American spelling and the preferred IUPAC name) or sulphuric acid (English in the Commonwealth of Nations, Commonwealth spelling), known in antiquity as oil of vitriol, is a mineral acid composed of the elements sulfur, oxygen, ...
. Carbon monoxide is oxidized at one electrode to carbon dioxide while oxygen is consumed at the other electrode. For carbon monoxide detection, the electrochemical cell has advantages over other technologies in that it has a highly accurate and linear output to carbon monoxide concentration, requires minimal power as it is operated at room temperature, and has a long lifetime, which typically is five years to ten years. This technology has become the dominant technology in the United States and Europe. Test buttons only indicate the operational effectiveness of the battery, circuit, and buzzer. The only way to fully test the operation of a CO alarm using an electrochemical cell is with a known source of calibrated test gas delivered in a shroud to maintain the concentration level for the test period.


Semiconductor type

Thin wires of the
semiconductor A semiconductor is a material with electrical conductivity between that of a conductor and an insulator. Its conductivity can be modified by adding impurities (" doping") to its crystal structure. When two regions with different doping level ...
tin dioxide Tin(IV) oxide, also known as stannic oxide, is the inorganic compound with the formula SnO2. The mineral form of SnO2 is called cassiterite, and this is the main ore of tin. With many other names, this oxide of tin is an important material in ti ...
on an insulating ceramic base provide a sensor monitored by an integrated circuit. This sensing element must be heated to approximately 400 °C for operation. Oxygen increases the resistance of the tin dioxide while carbon monoxide reduces it. The integrated circuit monitors the resistance of the sensing element. Lifespans are approximately five years and alarms need testing on installation and at least annually with a test gas. Due to the large power demand of this sensor, it is usually powered from the mains. A battery-powered, pulsed sensor is available with a lifetime of months. This technology is widely used in Japan and elsewhere in the Far East, with some market penetration in the USA. However, the superior performance of electrochemical cell technology is beginning to displace this technology.


Concentration readout

Although all home detectors use an audible alarm signal as the primary indicator, some versions also offer a digital readout of the CO concentration, in
parts per million In science and engineering, the parts-per notation is a set of pseudo-units to describe the small values of miscellaneous dimensionless quantity, dimensionless quantities, e.g. mole fraction or mass fraction (chemistry), mass fraction. Since t ...
(PPM). Typically, they can display both the current reading and a peak reading from memory of the highest level measured over some time. These advanced models cost somewhat more but are otherwise similar to the basic models. The models with display have the advantages of indicating levels below the alarm threshold, reporting levels that may have occurred during an absence, and assessing the degree of hazard if the alarm sounds. They may also aid emergency responders in evaluating the level of past or ongoing exposure or danger.


Portable

Portable detectors are designed for aircraft, cars and trucks. They warn vehicle occupants of any CO hazard.


CO measurement instruments

Portable meters which display CO concentration down to a few PPM are more sensitive than home safety CO detectors and correspondingly much more expensive. They are used by industrial hygienists and first responders, and for maintenance and tracing a CO leak. These devices measure low levels of CO in seconds, rather than minutes or hours like residential alarms. Like other test equipment, professional CO meters must be tested and recalibrated periodically.


Legislation


United States

In the US () 32 states have enacted statutes regarding carbon monoxide detectors, and another 11 have promulgated regulations on CO detectors, as well as in
Washington DC Washington, D.C., formally the District of Columbia and commonly known as Washington or D.C., is the capital city and Federal district of the United States, federal district of the United States. The city is on the Potomac River, across from ...
and
New York City New York, often called New York City (NYC), is the most populous city in the United States, located at the southern tip of New York State on one of the world's largest natural harbors. The city comprises five boroughs, each coextensive w ...
. In Canada, CO alarm requirements came into effect on October 15, 2014 in
Ontario Ontario is the southernmost Provinces and territories of Canada, province of Canada. Located in Central Canada, Ontario is the Population of Canada by province and territory, country's most populous province. As of the 2021 Canadian census, it ...
, there is a strong movement in
Alberta Alberta is a Provinces and territories of Canada, province in Canada. It is a part of Western Canada and is one of the three Canadian Prairies, prairie provinces. Alberta is bordered by British Columbia to its west, Saskatchewan to its east, t ...
to make CO detectors mandatory in all homes. More and more states are legislating for their installation as a mandatory feature. House builders in
Colorado Colorado is a U.S. state, state in the Western United States. It is one of the Mountain states, sharing the Four Corners region with Arizona, New Mexico, and Utah. It is also bordered by Wyoming to the north, Nebraska to the northeast, Kansas ...
are required to install carbon monoxide detectors in new homes by a bill signed into law in March 2009. House Bill 1091 requires the installation of the detectors in new and resold homes near bedrooms as well as rented apartments and homes. It took effect on July 1, 2009. The legislation was introduced after the death of Denver investment banker Parker Lofgren and his family. Lofgren, along with his wife and children were found dead in their home near Aspen, Colorado on Nov. 27, 2008, victims of carbon-monoxide poisoning. In New York State "Amanda's Law" (A6093A/C.367) requires one- and two-family residences that have fuel-burning appliances to have at least one carbon monoxide alarm installed on the lowest story having a sleeping area, effective February 22, 2010. Although homes built before January 1, 2008 are allowed to have battery-powered alarms, homes built after that date must have hard-wired alarms. In addition, New York State contractors must install a carbon monoxide detector when replacing a fuel-burning water heater or furnace if the home is without an alarm. The law is named for Amanda Hansen, a teenager who died from carbon monoxide poisoning from a defective boiler while at a sleepover at a friend's house. Alaska House Bill 351 requires a carbon monoxide detector to be installed in dwelling units that contain or are serviced by a carbon-based fuel appliance or other device that produces by-products of combustion. In July 2011, California required the installation of carbon monoxide detectors in existing single-family homes, with multifamily homes following in 2013. CA Law 2015 require all new installation of smoke and CO alarms to be 10-year non-serviceable type. Existing alarms may not need to be replaced for homeowners, see local codes. Required alarm locations also vary per local enforcing agencies. In Maine all rental units must have carbon monoxide detectors. In nonrental homes they are recommended but not required.


Standards

;North America The Canadian Mortgage and Housing Association reports, "The standards organizations of Canada (CSA) and the United States (Underwriters Laboratories or UL) have coordinated the writing of CO standards and product testing. The standards as of 2010 prohibit showing CO levels of less than 30 PPM on digital displays. The most recent standards also require the alarm to sound at higher levels of CO than with previous editions of the standard. The reasoning behind these changes is to reduce calls to fire stations, utilities and emergency response teams when the levels of CO are not life threatening. This change will also reduce the number of calls to these agencies due to detector inaccuracy or the presence of other gases. Consequently, new alarms will not sound at CO concentrations up to 70 PPM. Note that these concentrations are significantly in excess of the Canadian health guidelines,"Canadian Mortgage and Housing Association
(and also in excess of US
Occupational Safety and Health Administration The Occupational Safety and Health Administration (OSHA; ) is a regulatory agency of the United States Department of Labor that originally had federal visitorial powers to inspect and examine workplaces. The United States Congress established ...
(OSHA)
Permissible exposure limit The permissible exposure limit (PEL or OSHA PEL) is a legal limit in the United States for exposure of an employee to a chemical substance or physical agents such as high level noise. Permissible exposure limits were established by the Occupational ...
s, which is 50 PPM).


References


External links

* * {{DEFAULTSORT:Carbon Monoxide Detector American inventions Detector Detectors Natural gas safety Safety equipment Fire detection and alarm Fire prevention Home automation Indoor air pollution