Automatic meter reading (AMR) is the technology of automatically collecting consumption, diagnostic, and status data from
water meter
Water metering is the practice of measuring water use. Water meters measure the volume of water used by residential and commercial building units that are supplied with water by a public water supply system. They are also used to determine Flui ...
or
energy metering devices (gas, electric) and transferring that data to a central database for billing, troubleshooting, and analyzing.
This technology mainly saves utility providers the expense of periodic trips to each physical location to read a meter. Another advantage is that billing can be based on near real-time consumption rather than on estimates based on past or predicted consumption. This timely information coupled with analysis can help both utility providers and customers better control the use and production of electric energy, gas usage, or
water consumption.
AMR technologies include handheld, mobile and network technologies based on telephony platforms (wired and wireless), radio frequency (RF), or powerline transmission.
Technologies
Touch technology
With touch-based AMR, a meter reader carries a handheld computer or data collection device with a wand or probe. The device automatically collects the readings from a meter by touching or placing the read probe in close proximity to a reading
coil enclosed in the touchpad. When a button is pressed, the probe sends an interrogate signal to the touch module to collect the meter reading. The software in the device matches the serial number to one in the route database, and saves the meter reading for later download to a billing or data collection computer. Since the meter reader still has to go to the site of the meter, this is sometimes referred to as "on-site" AMR. Another form of contact reader uses a standardized infrared port to transmit data. Protocols are standardized between manufacturers by such documents as
ANSI C12.18 or
IEC 61107.
AMR hosting
AMR hosting is a back-office solution which allows a user to track their
electricity
Electricity is the set of physical phenomena associated with the presence and motion of matter possessing an electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described by Maxwel ...
,
water
Water is an inorganic compound with the chemical formula . It is a transparent, tasteless, odorless, and Color of water, nearly colorless chemical substance. It is the main constituent of Earth's hydrosphere and the fluids of all known liv ...
, or
gas consumption over the Internet. All data is collected in near real-time, and is stored in a database by data acquisition software. The user can view the data via a web application, and can analyze the data using various online analysis tools such as charting load profiles, analyzing tariff components, and verify their utility bill.
Radio frequency network
Radio frequency
Radio frequency (RF) is the oscillation rate of an alternating electric current or voltage or of a magnetic, electric or electromagnetic field or mechanical system in the frequency range from around to around . This is roughly between the u ...
based AMR can take many forms. The more common ones are handheld, mobile, satellite and fixed network solutions. There are both two-way RF systems and one-way RF systems in use that use both licensed and unlicensed RF bands.
In a two-way or "wake up" system, a radio signal is normally sent to an AMR meter's unique serial number, instructing its
transceiver
In radio communication, a transceiver is an electronic device which is a combination of a radio ''trans''mitter and a re''ceiver'', hence the name. It can both transmit and receive radio waves using an antenna, for communication purposes. The ...
to power-up and transmit its data. The meter transceiver and the reading transceiver both send and receive radio signals. In a one-way "bubble-up" or continuous
broadcast
Broadcasting is the data distribution, distribution of sound, audio audiovisual content to dispersed audiences via a electronic medium (communication), mass communications medium, typically one using the electromagnetic spectrum (radio waves), ...
type system, the meter transmits continuously and data is sent every few seconds. This means the reading device can be a receiver only, and the meter a transmitter only. Data travels only from the meter transmitter to the reading receiver. There are also hybrid systems that combine one-way and two-way techniques, using one-way communication for reading and two-way communication for programming functions.
RF-based meter reading usually eliminates the need for the meter reader to enter the property or home, or to locate and open an underground meter pit. The utility saves money by increased speed of reading, has less liability from entering private property, and has fewer missed readings from being unable to access the meter.
The technology based on RF is not readily accepted everywhere. In several Asian countries, the technology faces a barrier of regulations in place pertaining to use of the radio frequency of any radiated power. For example, in India the radio frequency which is generally in
ISM band
The ISM radio bands are portions of the radio spectrum reserved internationally for ''industrial, scientific, and medical'' (ISM) purposes, excluding applications in telecommunications.
Examples of applications for the use of radio frequency (RF ...
is not free to use even for low power radio of 10
mW. The majority of manufacturers of electricity meters have radio frequency devices in the frequency band of 433/868 MHz for large scale deployment in European countries. The frequency band of 2.4 GHz can be now used in India for outdoor as well as indoor applications, but few manufacturers have shown products within this frequency band. Initiatives in radio frequency AMR in such countries are being taken up with regulators wherever the cost of licensing outweighs the benefits of AMR.
Handheld
In handheld AMR, a meter reader carries a handheld computer with a built-in or attached receiver/transceiver (radio frequency or touch) to collect meter readings from an AMR capable meter. This is sometimes referred to as "walk-by" meter reading since the meter reader walks by the locations where meters are installed as they go through their meter reading route. Handheld computers may also be used to manually enter readings without the use of AMR technology as an alternate but this will not support exhaustive data which can be accurately read using the meter reading electronically.
Mobile
Mobile or "drive-by" meter reading is where a reading device is installed in a vehicle. The meter reader drives the vehicle while the reading device automatically collects the meter readings. Often, for mobile meter reading, the reading equipment includes navigational and mapping features provided by
GPS and mapping software. With mobile meter reading, the reader does not normally have to read the meters in any particular route order, but just drives the service area until all meters are read. Components often consist of a laptop or proprietary computer, software, RF receiver/transceiver, and external vehicle
antennas.
Satellite
Transmitters for
data collection satellites can be installed in the field next to existing meters. The satellite AMR devices communicate with the meter for readings, and then sends those readings over a fixed or mobile satellite network. This network requires a clear view to the sky for the satellite transmitter/receiver, but eliminates the need to install fixed towers or send out field technicians, thereby being particularly suited for areas with low geographic meter density.
RF technologies commonly used for AMR
* Narrow Band (single fixed radio frequency)
*
Spread spectrum
In telecommunications, especially radio communication, spread spectrum are techniques by which a signal (electrical engineering), signal (e.g., an electrical, electromagnetic, or acoustic) generated with a particular Bandwidth (signal processi ...
**
Direct-sequence spread spectrum
In telecommunications, direct-sequence spread spectrum (DSSS) is a spread-spectrum modulation technique primarily used to reduce overall signal interference. The direct-sequence modulation makes the transmitted signal wider in bandwidth tha ...
(DSSS)
**
Frequency-hopping spread spectrum
Frequency-hopping spread spectrum (FHSS) is a method of transmitting radio signals by rapidly changing the carrier frequency among many frequencies occupying a large spectral band. The changes are controlled by a code known to both transmitter ...
(FHSS)
There are also meters using AMR with RF technologies such as cellular phone data systems,
Zigbee
Zigbee is an IEEE 802.15.4-based specification for a suite of high-level communication protocols used to create personal area networks with small, low-power digital radios, such as for home automation, medical device data collection, and oth ...
,
Bluetooth
Bluetooth is a short-range wireless technology standard that is used for exchanging data between fixed and mobile devices over short distances and building personal area networks (PANs). In the most widely used mode, transmission power is li ...
,
Wavenis and others. Some systems operate with U.S.
Federal Communications Commission
The Federal Communications Commission (FCC) is an independent agency of the United States government that regulates communications by radio, television, wire, internet, wi-fi, satellite, and cable across the United States. The FCC maintains j ...
(FCC) licensed frequencies and others under
FCC Part 15, which allows use of unlicensed radio frequencies.
Wi-Fi
WiSmart is a versatile platform which can be used by a variety of electrical home appliances in order to provide wireless
TCP/IP
The Internet protocol suite, commonly known as TCP/IP, is a framework for organizing the communication protocols used in the Internet and similar computer networks according to functional criteria. The foundational protocols in the suite are ...
communication using the 802.11 b/g protocol.
Devices such as the Smart Thermostat permit a utility to lower a home's power consumption to help manage power demand.
The city of
Corpus Christi became one of the first cities in the
United States
The United States of America (USA), also known as the United States (U.S.) or America, is a country primarily located in North America. It is a federal republic of 50 U.S. state, states and a federal capital district, Washington, D.C. The 48 ...
to implement citywide
Wi-Fi
Wi-Fi () is a family of wireless network protocols based on the IEEE 802.11 family of standards, which are commonly used for Wireless LAN, local area networking of devices and Internet access, allowing nearby digital devices to exchange data by ...
, which had been free until May 31, 2007, mainly to facilitate AMR after a meter reader was attacked by a dog. Today many meters are designed to transmit using Wi-Fi, even if a Wi-Fi network is not available, and they are read using a drive-by local Wi-Fi hand held receiver.
The meters installed in Corpus Christi are not directly Wi-Fi enabled, but rather transmit narrow-band burst
telemetry
Telemetry is the in situ collection of measurements or other data at remote points and their automatic transmission to receiving equipment (telecommunication) for monitoring. The word is derived from the Greek roots ''tele'', 'far off', an ...
on the 460 MHz band. This narrow-band signal has much greater range than Wi-Fi, so the number of receivers required for the project are far fewer. Special receiver stations then decode the narrow-band signals and resend the data via Wi-Fi.
Most of the automated utility meters installed in the Corpus Christi area are battery powered. Wi-Fi technology is unsuitable for long-term battery-powered operation.
Power line communication
PLC is a method where electronic data is transmitted over power lines back to the substation, then relayed to a central computer in the utility's main office. This would be considered a type of fixed network system—the network being the distribution network which the utility has built and maintains to deliver electric power. Such systems are primarily used for electric meter reading. Some providers have interfaced gas and water meters to feed into a PLC type system.
Brief history
In 1972,
Theodore George "Ted" Paraskevakos, while working with
Boeing
The Boeing Company, or simply Boeing (), is an American multinational corporation that designs, manufactures, and sells airplanes, rotorcraft, rockets, satellites, and missiles worldwide. The company also provides leasing and product support s ...
in
Huntsville, Alabama
Huntsville is the List of municipalities in Alabama, most populous city in the U.S. state of Alabama. The population of the city is estimated to be 241,114 in 2024, making it the List of United States cities by population, 100th-most populous ...
, developed a sensor monitoring system which used digital transmission for security, fire and medical alarm systems as well as meter reading capabilities for all utilities. This technology was a spin-off of the automatic telephone line identification system, now known as
caller ID
Caller identification (Caller ID) is a telephone service, available in analog and digital telephone systems, including voice over IP (VoIP), that transmits a caller's telephone number to the called party's telephone equipment when the call is ...
.
In 1974, Paraskevakos was awarded a U.S. patent for this technology. In 1977, he launched Metretek, Inc., which developed and produced the first fully automated, commercially available remote meter reading and load management system. Since this system was developed pre-Internet, Metretek utilized the
IBM series 1 mini-computer. For this approach, Paraskevakos and Metretek were awarded multiple patents.
The primary driver for the automation of meter reading is not to reduce labor costs, but to obtain data that is difficult to obtain. As an example, many water meters are installed in locations that require the utility to schedule an appointment with the homeowner in order to obtain access to the meter. In many areas, consumers have demanded that their monthly water bill be based on an actual reading, instead of (for example) an estimated monthly usage based on just one actual meter reading made every 12 months. Early AMR systems often consisted of walk-by and drive-by AMR for residential customers, and telephone-based AMR for commercial or industrial customers. What was once a need for monthly data became a need for daily and even hourly readings of the meters. Consequently, the sales of drive-by and telephone AMR has declined in the US, while sales of fixed networks has increased. The US
Energy Policy Act of 2005
The Energy Policy Act of 2005 () is a federal law signed by President George W. Bush on August 8, 2005, at Sandia National Laboratories in Albuquerque, New Mexico. The act, described by proponents as an attempt to combat growing energy problems ...
asks that electric utility regulators consider the support for a "...time-based rate schedule ''(to)'' enable the electric consumer to manage energy use and cost through advanced metering and communications technology."
The trend now is to consider the use of advanced meters as part of an
advanced metering infrastructure
A smart meter is an Electronics, electronic device that records information—such as consumption of electric energy, voltage levels, current, and power factor—and Telemetering, communicates the information to the consumer and Public utility, ...
.
Advanced AMR and AMI
Originally AMR devices just collected meter readings electronically and matched them with accounts. As technology has advanced, additional data could then be captured, stored, and transmitted to the main computer, and often the metering devices could be controlled remotely. This can include events alarms such as tamper, leak detection, low battery, or reverse flow. Many AMR devices can also capture interval data, and log meter events. The logged data can be used to collect or control time of use or rate of use data that can be used for water or energy usage profiling, time of use billing, demand forecasting,
demand response
Demand response is a change in the power consumption of an electric utility customer to better match the demand for power with the supply. Until the 21st century decrease in the cost of pumped storage and batteries, electric energy could not b ...
,
rate of flow recording,
leak detection, flow monitoring,
water
Water is an inorganic compound with the chemical formula . It is a transparent, tasteless, odorless, and Color of water, nearly colorless chemical substance. It is the main constituent of Earth's hydrosphere and the fluids of all known liv ...
and
energy conservation
Energy conservation is the effort to reduce wasteful energy consumption by using fewer energy services. This can be done by using energy more effectively (using less and better sources of energy for continuous service) or changing one's behavi ...
enforcement, remote shutoff, etc.
Advanced metering infrastructure
A smart meter is an Electronics, electronic device that records information—such as consumption of electric energy, voltage levels, current, and power factor—and Telemetering, communicates the information to the consumer and Public utility, ...
, or AMI is the new term coined to represent the networking technology of fixed network meter systems that go beyond AMR into remote utility management. The meters in an AMI system are often referred to as
smart meter
A smart meter is an electronic device that records information—such as consumption of electric energy, voltage levels, current, and power factor—and communicates the information to the consumer and electricity suppliers. Advanced meterin ...
s, since they often can use collected data based on programmed logic.
The Automatic Meter Reading Association (AMRA) endorses the National Association of Regulatory Utility Commissioners (NARUC) resolution to eliminate regulatory barriers to the broad implementation of advanced metering infrastructure (AMI). The resolution, passed in February 2007, acknowledged the role of AMI in supporting the implementation of dynamic pricing and the resulting benefits to consumers. The resolution further identified the value of AMI in achieving significant utility operational cost savings in the areas of outage management, revenue protection and asset management. The resolution also called for AMI business case analysis to identify cost-effective deployment strategies, endorsed timely cost recovery for prudently incurred AMI expenditures and made additional recommendations on rate making and tax treatment of such investments.
Benefits of advanced metering
Advanced metering systems can provide benefits for utilities, retail providers and customers. Benefits will be recognized by the utilities with increased efficiencies, outage detection, tamper notification and reduced labor cost as a result of automating reads, connections and disconnects. Retail providers will be able to offer new innovative products in addition to customizing packages for their customers. In addition, with the meter data being readily available, more flexible billing cycles would be available to their customers instead of following the standard utility read cycles. With timely usage information available to the customer, benefits will be seen through opportunities to manage their energy consumption and change from one REP to another with actual meter data. Because of these benefits, many utilities are moving towards implementing some types of AMR solutions.
In many cases, smart metering is required by law (e.g. Pennsylvania's Act 129 (2008)).
The benefits of smart metering for the utility.
* Accurate meter reading, no more estimates
* Improved billing
* Accurate profile classes and measurement classes, true costs applied
* Improved security and tamper detection for equipment
* Energy management through profile data graphs
* Less financial burden correcting mistakes
* Less accrued expenditure
* Transparency of "cost to read" metering
* Improved procurement power though more accurate data — "de-risking" price
* In cases of shortages, utility will be able to manage/allocate supply.
The benefits of smart metering for the customer.
* Improved billing and tracking of usage.
Disadvantages of advanced metering
* Risk of loss of privacy — details of use reveal information about user activities
[Privacy on the Smart Grid](_blank)
/ref>
* Greater potential for monitoring by other/unauthorized third parties
* Potentially reduced reliability (more complicated meters, more potential for interference by third parties)
* Increased security risks from network or remote access
Notable deployments
Construction practices, weather, and the need for information drive utilities in different parts of the world towards AMR at different rates. In the US, there have been significant fixed network deployments of both RF based and PLC based technologies. Some countries have either deployed or plan to deploy AMR systems throughout the entire country.
SPAR
By using a combination of AMR and energy analytics reports, SPAR were able to reduce energy consumption by 20%.
Australia
AMI in Australia has grown from both government policy which sought to rectify observed market inefficiencies, and distribution businesses who looked to gain operational efficiencies. In July 2008, there was a mandated program being planned in Victoria for the deployment of 2.6 million meters over a 4-year period. The anticipated peak installation rate of AMI meters was 5,000 per day across Victoria. The program governance was provided by an industry steering committee.
In 2009 the Victorian Auditor General undertook a review of the program and found that there were "significant inadequacies" in advice to Government and that project governance "has not been appropriate". The Victorian government subsequently announced a moratorium of the program
Public Utility Commission of Texas Report 2006
*Pennsylvania, (Exelon
Exelon Corporation is an American public utility headquartered in Chicago, and incorporated in Pennsylvania. Exelon is the largest electric parent company in the United States by revenue and is the largest regulated electric utility in the Uni ...
-PECO) 2.2 million meters deployed
*Missouri, (Ameren
Ameren Corporation is an American power company created December 31, 1997, by the merger of Union Electric Company (formerly NYSE: UEP) of St. Louis, Missouri and the neighboring Central Illinois Public Service Company (CIPSCO Inc. holding, for ...
) 1.7 million meters deployed.
The future of AMR
With the growing adoption of AMI meters and systems, AMR has been in decline in the U.S. electric utility sector. However, in the gas and water sectors, where it tends to be more expensive and complicated to replace meters, AMR remains prevalent, and some utilities continue to invest in new AMR meter deployments. Going forward, utilities face a choice to replace AMR with AMI—often at great expense and time investment—or to explore an AMx strategy using modern signal collection and processing technology that allows for more frequent wireless data collection from existing AMR meters (in some cases down to every 30 seconds) while offering increased interoperability with other (potentially more advanced) meters in areas where they make offer incremental benefits. Whereas the first approach is likely to continue the gradual decline of AMR, the latter approach could lead to a resurgence of interest in next-generation AMR meters that can unlock near-real-time data at lower cost and with longer useful lives, while also virtually eliminating the need for trucks to drive by for data collection.
See also
* Encoder receiver transmitter
* Distributed generation
Distributed generation, also distributed energy, on-site generation (OSG), or district/decentralized energy, is electrical generation and storage performed by a variety of small, grid-connected or distribution system-connected devices referred ...
* Electricity meter
file:Hydro quebec meter.JPG, North American domestic analog signal, analog (Galileo Ferraris, Ferraris disk) electricity meter.
file:Transparent Electricity Meter found in Israel.JPG, Electricity meter with transparent plastic case (Israel)
fil ...
* Feed-in tariff
A feed-in tariff (FIT, FiT, standard offer contract,Couture, T., Cory, K., Kreycik, C., Williams, E., (2010)Policymaker's Guide to Feed-in Tariff Policy Design National Renewable Energy Laboratory, U.S. Dept. of Energy advanced renewable tariff, ...
* Gas meter
* Net metering
Net metering (or net energy metering, NEM) is an electricity billing mechanism that allows consumers who generate some or all of their own electricity to use that electricity anytime, instead of when it is generated. This is particularly impor ...
* Nonintrusive load monitoring
* Meter-Bus
* Open metering system
* Power line communication
Power-line communication (PLC) is the carrying of data on a conductor (the ''power-line carrier'') that is also used simultaneously for AC electric power transmission or electric power distribution to consumers.
A wide range of power-line comm ...
* Public utility
A public utility company (usually just utility) is an organization that maintains the infrastructure for a public service (often also providing a service using that infrastructure). Public utilities are subject to forms of public control and ...
* Smart meter
A smart meter is an electronic device that records information—such as consumption of electric energy, voltage levels, current, and power factor—and communicates the information to the consumer and electricity suppliers. Advanced meterin ...
* Utility submetering
* Water meter
Water metering is the practice of measuring water use. Water meters measure the volume of water used by residential and commercial building units that are supplied with water by a public water supply system. They are also used to determine Flui ...
References
External links
*
What is the 'Smart Grid'?
{{DEFAULTSORT:Automatic Meter Reading
Water technology
Flow meters
Electric power distribution
Public services
Automation