10 Gigabit Ethernet
   HOME

TheInfoList



OR:

10 Gigabit Ethernet (abbreviated 10GE, 10GbE, or 10 GigE) is a group of
computer network A computer network is a collection of communicating computers and other devices, such as printers and smart phones. In order to communicate, the computers and devices must be connected by wired media like copper cables, optical fibers, or b ...
ing technologies for transmitting
Ethernet frame In computer networking, an Ethernet frame is a data link layer protocol data unit and uses the underlying Ethernet physical layer transport mechanisms. In other words, a data unit on an Ethernet link transports an Ethernet frame as its paylo ...
s at a rate of 10  gigabits per second. It was first defined by the IEEE 802.3ae-2002 standard. Unlike previous Ethernet standards, 10GbE defines only
full-duplex A duplex communication system is a point-to-point system composed of two or more connected parties or devices that can communicate with one another in both directions. Duplex systems are employed in many communications networks, either to allow ...
point-to-point links which are generally connected by
network switch A network switch (also called switching hub, bridging hub, Ethernet switch, and, by the IEEE, MAC bridge) is networking hardware that connects devices on a computer network by using packet switching to receive and forward data to the destinat ...
es; shared-medium CSMA/CD operation has not been carried over from the previous generations of Ethernet standards so half-duplex operation and repeater hubs do not exist in 10GbE. The first standard for faster
100 Gigabit Ethernet 40 Gigabit Ethernet (40GbE) and 100 Gigabit Ethernet (100GbE) are groups of computer networking technologies for transmitting Ethernet frames at rates of 40 and 100 gigabits per second (Gbit/s), respectively. These technologies offer significantly ...
links was approved in 2010. The 10GbE standard encompasses a number of different
physical layer In the seven-layer OSI model of computer networking, the physical layer or layer 1 is the first and lowest layer: the layer most closely associated with the physical connection between devices. The physical layer provides an electrical, mechani ...
(PHY) standards. A networking device, such as a switch or a
network interface controller A network interface controller (NIC, also known as a network interface card, network adapter, LAN adapter and physical network interface) is a computer hardware component that connects a computer to a computer network. Early network interface ...
may have different PHY types through pluggable PHY modules, such as those based on SFP+. Like previous versions of Ethernet, 10GbE can use either copper or fiber cabling. Maximum distance over copper cable is 100 meters but because of its bandwidth requirements, higher-grade cables are required. The adoption of 10GbE has been more gradual than previous revisions of
Ethernet Ethernet ( ) is a family of wired computer networking technologies commonly used in local area networks (LAN), metropolitan area networks (MAN) and wide area networks (WAN). It was commercially introduced in 1980 and first standardized in 198 ...
: in 2007, one million 10GbE ports were shipped, in 2009 two million ports were shipped, and in 2010 over three million ports were shipped, with an estimated nine million ports in 2011. , although the price per gigabit of bandwidth for 10GbE was about one-third compared to
Gigabit Ethernet In computer networking, Gigabit Ethernet (GbE or 1 GigE) is the term applied to transmitting Ethernet frames at a rate of a gigabit per second. The most popular variant, 1000BASE-T, is defined by the IEEE 802.3ab standard. It came into use in ...
, the price per port of 10GbE still hindered more widespread adoption. By 2022, the price per port of 10GBase-T had dropped to $50 - $100 depending on scale. In 2023, Wi-Fi 7 routers began appearing with 10GbE WAN ports as standard.


Standards

Over the years the
Institute of Electrical and Electronics Engineers The Institute of Electrical and Electronics Engineers (IEEE) is an American 501(c)(3) public charity professional organization for electrical engineering, electronics engineering, and other related disciplines. The IEEE has a corporate office ...
(IEEE) 802.3 working group has published several standards relating to 10GbE.


Physical layer modules

To implement different 10GbE physical layer standards, many interfaces consist of a standard socket into which different physical (PHY) layer modules may be plugged. PHY modules are not specified in an official standards body but by multi-source agreements (MSAs) that can be negotiated more quickly. Relevant MSAs for 10GbE include XENPAK (and related X2 and XPAK), XFP and SFP+. When choosing a PHY module, a designer considers cost, reach, media type, power consumption, and size (form factor). A single point-to-point link can have different MSA pluggable formats on either end (e.g. XPAK and SFP+) as long as the 10GbE optical or copper port type (e.g. 10GBASE-SR) supported by the pluggable is identical. XENPAK was the first MSA for 10GE and had the largest form factor. X2 and XPAK were later competing standards with smaller form factors. X2 and XPAK have not been as successful in the market as XENPAK. XFP came after X2 and XPAK and it is also smaller. The newest module standard is the
enhanced small form-factor pluggable transceiver Small Form-factor Pluggable connected to a pair of fiber-optic cables Small Form-factor Pluggable (SFP) is a compact, hot-pluggable network interface module format used for both telecommunication and data communications applications. An SFP ...
, generally called SFP+. Based on the
small form-factor pluggable transceiver Small Form-factor Pluggable connected to a pair of fiber-optic cables Small Form-factor Pluggable (SFP) is a compact, hot-pluggable network interface module format used for both telecommunication and data communications applications. An SFP ...
(SFP) and developed by the ANSI T11
fibre channel Fibre Channel (FC) is a high-speed data transfer protocol providing in-order, lossless delivery of raw block data. Fibre Channel is primarily used to connect computer data storage to Server (computing), servers in storage area networks (SAN) in ...
group, it is smaller still and lower power than XFP. SFP+ has become the most popular socket on 10GE systems. SFP+ modules do only optical to electrical conversion, no clock and data recovery, putting a higher burden on the host's channel equalization. SFP+ modules share a common physical form factor with legacy SFP modules, allowing higher port density than XFP and the re-use of existing designs for 24 or 48 ports in a
19-inch rack A 19-inch rack is a standardized frame or enclosure for mounting multiple electronic equipment modules. Each module has a front panel that is wide. The 19 inch dimension includes the edges or ''ears'' that protrude from each side of the ...
width blade. Optical modules are connected to a host by either a XAUI, XFI or SerDes Framer Interface (SFI) interface. XENPAK, X2, and XPAK modules use XAUI to connect to their hosts. XAUI (XGXS) uses a four-lane data channel and is specified in IEEE 802.3 Clause 47. XFP modules use a XFI interface and SFP+ modules use an SFI interface. XFI and SFI use a single lane data channel and the 64b/66b encoding specified in IEEE 802.3 Clause 49. SFP+ modules can further be grouped into two types of host interfaces: linear or limiting. Limiting modules are preferred except when for long-reach applications using 10GBASE-LRM modules.


Optical fiber

There are two basic types of
optical fiber An optical fiber, or optical fibre, is a flexible glass or plastic fiber that can transmit light from one end to the other. Such fibers find wide usage in fiber-optic communications, where they permit transmission over longer distances and at ...
used for 10 Gigabit Ethernet: single-mode (SMF) and multi-mode (MMF). In SMF light follows a single path through the fiber while in MMF it takes multiple paths resulting in differential mode delay (DMD). SMF is used for long-distance communication and MMF is used for distances of less than 300 m. SMF has a narrower core (8.3 μm) which requires a more precise termination and connection method. MMF has a wider core (50 or 62.5 μm). The advantage of MMF is that it can be driven by a low cost Vertical-cavity surface-emitting laser (VCSEL) for short distances, and multi-mode connectors are cheaper and easier to terminate reliably in the field. The advantage of SMF is that it can work over longer distances. In the 802.3 standard, reference is made to FDDI-grade MMF fiber. This has a 62.5 μm core and a minimum
modal bandwidth Modal may refer to: * Modal (textile) * Modal (drug) * Modal (company) See also * Mode (disambiguation) Mode ( meaning "manner, tune, measure, due measure, rhythm, melody") may refer to: Arts and entertainment * MO''D''E (magazine), a def ...
of 160 MHz·km at 850 nm. It was originally installed in the early 1990s for
FDDI Fiber Distributed Data Interface (FDDI) is a standard for data transmission in a local area network. It uses optical fiber as its standard underlying physical medium. It was also later specified to use copper cable, in which case it may be c ...
and 100BASE-FX networks. The 802.3 standard also references ISO/IEC 11801 which specifies optical MMF fiber types OM1, OM2, OM3 and OM4. OM1 has a 62.5 μm core while the others have a 50 μm core. At 850 nm the minimum modal bandwidth of OM1 is 200 MHz·km, of OM2 500 MHz·km, of OM3 2000 MHz·km and of OM4 4700 MHz·km. FDDI-grade cable is now obsolete and new
structured cabling In telecommunications, structured cabling is building or campus cabling infrastructure that consists of a number of standardized smaller elements (hence structured) called subsystems. Structured cabling components include twisted pair and opt ...
installations use either OM3 or OM4 cabling. OM3 cable can carry 10 Gigabit Ethernet 300 meters using low cost 10GBASE-SR optics. OM4 can manage 400 meters. To distinguish SMF from MMF cables, SMF cables are usually yellow, while MMF cables are orange (OM1 & OM2) or aqua (OM3 & OM4). However, in fiber optics there is no uniform color for any specific optical speed or technology with the exception being the angled physical contact connector (APC), being an agreed color of green. There are also active optical cables (AOC). These have the optical electronics already connected eliminating the connectors between the cable and the optical module. They plug into standard SFP+ sockets. They are lower cost than other optical solutions because the manufacturer can match the electronics to the required length and type of cable.


10GBASE-SR

10GBASE-SR ("short range") is a port type for
multi-mode fiber Multi-mode optical fiber is a type of optical fiber mostly used for communication over short distances, such as within a building or on a campus. Multi-mode links can be used for data rates up to 800 Gbit/s. Multi-mode fiber has a fairly ...
and uses 850 nm lasers. Its Physical Coding Sublayer (PCS) is 64b/66b and is defined in IEEE 802.3 Clause 49 and its Physical Medium Dependent (PMD) sublayer in Clause 52. It delivers serialized data at a line rate of .IEEE 802.3 ''52.1.1.1.2 PMD_UNITDATA.request: When generated'' The range depends on the type of multi-mode fiber used. MMF has the advantage over SMF of having lower cost connectors; its wider core requires less mechanical precision. The 10GBASE-SR transmitter is implemented with a VCSEL which is low cost and low power. OM3 and OM4 optical cabling is sometimes described as ''laser optimized'' because they have been designed to work with VCSELs. 10GBASE-SR delivers the lowest cost, lowest power and smallest form factor optical modules. There is a lower cost, lower power variant sometimes referred to as 10GBASE-SRL (10GBASE-SR lite). This is inter-operable with 10GBASE-SR but only has a reach of 100 meters.


10GBASE-LR

10GBASE-LR (long reach) is a port type for single-mode fiber and uses 1310 nm lasers. Its 64b/66b PCS is defined in IEEE 802.3 Clause 49 and its PMD sublayer in Clause 52. It delivers serialized data at a line rate of 10.3125 GBd. The 10GBASE-LR transmitter is implemented with a Fabry–Pérot or distributed feedback laser (DFB). DFB lasers are more expensive than VCSELs but their high power and longer wavelength allow efficient coupling into the small core of single-mode fiber over greater distances. 10GBASE-LR maximum fiber length is 10 kilometers, although this will vary depending on the type of single-mode fiber used.


10GBASE-LRM

10GBASE-LRM, (long reach multi-mode) originally specified in IEEE 802.3aq is a port type for multi-mode fiber and uses 1310 nm lasers. Its 64b/66b PCS is defined in IEEE 802.3 Clause 49 and its PMD sublayer in Clause 68. It delivers serialized data at a line rate of 10.3125 GBd. 10GBASE-LRM uses electronic dispersion compensation (EDC) for receive equalization. 10GBASE-LRM allows distances up to on FDDI-grade multi-mode fiber and the same 220m maximum reach on OM1, OM2 and OM3 fiber types. 10GBASE-LRM reach is not quite as far as the older 10GBASE-LX4 standard. Some 10GBASE-LRM transceivers also allow distances up to on standard single-mode fiber (SMF, G.652), however this is not part of the IEEE or MSA specification. To ensure that specifications are met over FDDI-grade, OM1 and OM2 fibers, the transmitter should be coupled through a mode conditioning patch cord. No mode conditioning patch cord is required for applications over OM3 or OM4.


10GBASE-ER

10GBASE-ER (extended reach) is a port type for single-mode fiber and uses 1550 nm lasers. Its 64b/66b PCS is defined in IEEE 802.3 Clause 49 and its PMD sublayer in Clause 52. It delivers serialized data at a line rate of 10.3125 GBd. The 10GBASE-ER transmitter is implemented with an externally modulated laser (EML). 10GBASE-ER has a reach of over engineered links and 30 km over standard links.


10GBASE-ZR

Several manufacturers have introduced range under the name 10GBASE-ZR. This 80 km PHY is not specified within the IEEE 802.3ae standard and manufacturers have created their own specifications based upon the 80 km PHY described in the
OC-192 Optical Carrier transmission rates are a standardized set of specifications of transmission bandwidth for digital signals that can be carried on Synchronous Optical Networking (SONET) fiber optic networks. Transmission rates are defined by rate o ...
/ STM-64 SDH/ SONET specifications.


10GBASE-LX4

10GBASE-LX4 is a port type for multi-mode fiber and single-mode fiber. It uses four separate laser sources operating at 3.125 Gbit/s and Coarse wavelength-division multiplexing with four unique wavelengths around 1310 nm. Its 8b/10b PCS is defined in IEEE 802.3 Clause 48 and its Physical Medium Dependent (PMD) sublayer in Clause 53. 10GBASE-LX4 has a range of over SMF. It can reach over FDDI-grade, OM1, OM2 and OM3 multi-mode cabling. In this case, it needs to be coupled through a SMF offset-launch mode-conditioning patch cord.


10GBASE-PR

10GBASE-PR originally specified in IEEE 802.3av is a 10 Gigabit Ethernet PHY for
passive optical network A passive optical network (PON) is a fiber-optic telecommunications network that uses only ''unpowered'' devices to carry signals, as opposed to electronic equipment. In practice, PONs are typically used for the '' last mile'' between Internet ...
s and uses 1577 nm lasers in the downstream direction and 1270 nm lasers in the upstream direction. Its PMD sublayer is specified in Clause 75. Downstream delivers serialized data at a line rate of 10.3125 Gbit/s in a point to multi-point configuration. 10GBASE-PR has three power budgets specified as 10GBASE-PR10, 10GBASE-PR20 and 10GBASE-PR30.


10GBASE-BR

Multiple vendors introduced single-strand, bi-directional 10 Gbit/s optics capable of a
single-mode fiber In fiber-optic communication, a single-mode optical fiber, also known as fundamental- or mono-mode, is an optical fiber designed to carry only a single mode of light - the transverse mode. Modes are the possible solutions of the Helmholtz equ ...
connection functionally equivalent to 10GBASE-LR or -ER, but using a single strand of fiber optic cable. Analogous to 1000BASE-BX10, this is accomplished using a passive prism inside each optical transceiver and a matched pair of transceivers using two different wavelengths such as 1270 and 1330 nm. Modules are available in varying transmit powers and reach distances ranging from 10 to 80 km. These advances were subsequently standardized in IEEE 802.3cp-2021 with reaches of 10, 20, or 40 km.


Copper

10 Gigabit Ethernet can also run over twin-axial cabling, twisted pair cabling, and
backplane A backplane or backplane system is a group of electrical connectors in parallel with each other, so that each pin of each connector is linked to the same relative pin of all the other connectors, forming a computer bus. It is used to connect s ...
s.


10GBASE-CX4

SFF-8470 connector 10GBASE-CX4 was the first 10 Gigabit copper standard published by 802.3 (as 802.3ak-2004). It uses the XAUI 4-lane PCS (Clause 48) and copper cabling similar to that used by
InfiniBand InfiniBand (IB) is a computer networking communications standard used in high-performance computing that features very high throughput and very low latency. It is used for data interconnect both among and within computers. InfiniBand is also used ...
technology with the same SFF-8470 connectors. It is specified to work up to a distance of . Each lane carries 3.125 GBd of signaling bandwidth. 10GBASE-CX4 has been used for stacking switches. It offers the advantages of low power, low cost and low latency, but has a bigger form factor and more bulky cables than the newer single-lane SFP+ standard, and a much shorter reach than fiber or 10GBASE-T. This cable is fairly rigid and considerably more costly than Category 5/6 UTP or fiber. 10GBASE-CX4 applications are now commonly achieved using SFP+ Direct Attach and , shipments of 10GBASE-CX4 have been very low.


SFP+ direct attach

Also known as direct attach (DA), direct attach copper (DAC), 10GSFP+Cu, sometimes also called 10GBASE-CR or 10GBASE-CX1, although there are no IEEE standards with either of the two latter names. Short direct attach cables use a passive
twinaxial cabling Twinaxial cabling, or twinax, is a type of cable similar to coaxial cable, but with two inner conductors in a twisted pair instead of one. Due to cost efficiency it is becoming common in modern (2013) very-short-range high-speed differential sig ...
assembly while longer ones add some extra range using
electronic amplifier An amplifier, electronic amplifier or (informally) amp is an electronic device that can increase the magnitude of a Signal (information theory), signal (a time-varying voltage or Electric current, current). It is a two-port network, two-port ...
s. These DAC types connect directly into an SFP+ housing. SFP+ direct attach has a fixed-length cable, up to 15 m for copper cables. Like 10GBASE-CX4, DA is low-power, low-cost and low-latency with the added advantages of using less bulky cables and of having the small SFP+ form factor. SFP+ direct attach today is tremendously popular, with more ports installed than 10GBASE-SR.


Backplane

Backplane Ethernet, also known by the name of the task force that developed it, 802.3ap, is used in
backplane A backplane or backplane system is a group of electrical connectors in parallel with each other, so that each pin of each connector is linked to the same relative pin of all the other connectors, forming a computer bus. It is used to connect s ...
applications such as
blade servers A blade server is a stripped-down server computer with a modular design optimized to minimize the use of physical space and energy. Blade servers have many components removed to save space, minimize power consumption and other considerations, whil ...
and modular network equipment with upgradable
line card A line card or digital line card is a modular electronic circuit designed to fit on a separate printed circuit board (PCB) and interface with a telecommunications access network. A line card typically interfaces with a twisted pair cable of a ...
s. 802.3ap implementations are required to operate over up to of copper printed circuit board with two connectors. The standard defines two port types for 10 Gbit/s (10GBASE-KX4 and 10GBASE-KR) and a single 1 Gbit/s port type (1000BASE-KX). It also defines an optional layer for
forward error correction In computing, telecommunication, information theory, and coding theory, forward error correction (FEC) or channel coding is a technique used for controlling errors in data transmission over unreliable or noisy communication channels. The centra ...
, a backplane autonegotiation protocol and link training for 10GBASE-KR where the receiver tunes a three-tap transmit equalizer. The autonegotiation protocol selects between 1000BASE-KX, 10GBASE-KX4, 10GBASE-KR or 40GBASE-KR4 operation.


10GBASE-KX4

This operates over four backplane lanes and uses the same physical layer coding (defined in IEEE 802.3 Clause 48) as 10GBASE-CX4.


10GBASE-KR

This operates over a single backplane lane and uses the same physical layer coding (defined in IEEE 802.3 Clause 49) as 10GBASE-LR/ER/SR. New backplane designs use 10GBASE-KR rather than 10GBASE-KX4.


10GBASE-T

10GBASE-T, or IEEE 802.3an-2006, is a standard released in 2006 to provide 10 Gbit/s connections over unshielded or shielded twisted pair cables, over distances up to . Category 6A is required to reach the full distance and category 5e or 6 may reach up to depending on the quality of installation. 10GBASE-T cable infrastructure can also be used for 1000BASE-T allowing a gradual upgrade from 1000BASE-T using
autonegotiation Autonegotiation is a signaling mechanism and procedure used by Ethernet over twisted pair by which two connected devices choose common transmission parameters, such as speed, Duplex_(telecommunications), duplex mode, and Flow_control_(data), flow ...
to select which speed is used. Due to additional
line coding In telecommunications, a line code is a pattern of voltage, current, or photons used to represent digital data transmitted down a communication channel or written to a storage medium. This repertoire of signals is usually called a constrained ...
overhead, 10GBASE-T has a slightly higher latency (2 to 4 microseconds) in comparison to most other 10GBASE variants (1 microsecond or less). In comparison, 1000BASE-T latency is 1 to 12 microseconds (depending on packet size). 10GBASE-T uses the IEC 60603-7
8P8C A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets. Modular connectors were originally developed for ...
modular connectors already widely used with Ethernet. Transmission characteristics are now specified to . To reach this frequency Category 6A or better balanced twisted pair cables specified in ISO/IEC 11801 amendment 2 or ANSI/TIA-568-C.2 are needed to carry 10GBASE-T up to 100 m.
Category 6 cable Category 6 cable (Cat 6) is a standardized twisted pair cable for Ethernet and other network physical layers that is backward compatible with the Category 5/5e and Category 3 cable standards. Cat 6 must meet more stringen ...
s can carry 10GBASE-T for shorter distances when qualified according to the guidelines in ISO TR 24750 or TIA-155-A. The 802.3an standard specifies the wire-level modulation for 10GBASE-T to use Tomlinson-Harashima precoding (THP) and
pulse-amplitude modulation Pulse-amplitude modulation (PAM) is a form of signal modulation in which the message information is encoded in the amplitude of a pulse train interrupting the carrier frequency. Demodulation is performed by detecting the amplitude level of th ...
with 16 discrete levels (PAM-16), encoded in a two-dimensional checkerboard pattern known as DSQ128 sent on the line at 800 Msymbols/sec. Prior to precoding,
forward error correction In computing, telecommunication, information theory, and coding theory, forward error correction (FEC) or channel coding is a technique used for controlling errors in data transmission over unreliable or noisy communication channels. The centra ...
(FEC) coding is performed using a 048,1723sub>2
low-density parity-check code Low-density parity-check (LDPC) codes are a class of error correction codes which (together with the closely-related turbo codes) have gained prominence in coding theory and information theory since the late 1990s. The codes today are widely us ...
on 1723 bits, with the parity check matrix construction based on a generalized Reed–Solomon 2,2,31code over GF(26). Another 1536 bits are uncoded. Within each 1723+1536 block, there are 1+50+8+1 signaling and error detection bits and 3200 data bits (and occupy 320 ns on the line). In contrast, PAM-5 is the modulation technique used in 1000BASE-T
Gigabit Ethernet In computer networking, Gigabit Ethernet (GbE or 1 GigE) is the term applied to transmitting Ethernet frames at a rate of a gigabit per second. The most popular variant, 1000BASE-T, is defined by the IEEE 802.3ab standard. It came into use in ...
. The line encoding used by 10GBASE-T is the basis for the newer and slower 2.5GBASE-T and 5GBASE-T standard, implementing a 2.5 or 5.0 Gbit/s connection over existing category 5e or 6 cabling. Cables that will not function reliably with 10GBASE-T may successfully operate with 2.5GBASE-T or 5GBASE-T if supported by both ends.


10GBASE-T1

10GBASE-T1 is for automotive applications and operates over a single balanced pair of conductors up to 15 m long, and is standardized in 802.3ch-2020.


WAN PHY (10GBASE-W)

At the time that the 10 Gigabit Ethernet standard was developed, interest in 10GbE as a
wide area network A wide area network (WAN) is a telecommunications network that extends over a large geographic area. Wide area networks are often established with leased telecommunication circuits. Businesses, as well as schools and government entities, use ...
(WAN) transport led to the introduction of a WAN PHY for 10GbE. The WAN PHY was designed to interoperate with OC-192/STM-64 SDH/SONET equipment using a light-weight SDH/SONET frame running at 9.953 Gbit/s. The WAN PHY operates at a slightly slower data-rate than the
local area network A local area network (LAN) is a computer network that interconnects computers within a limited area such as a residence, campus, or building, and has its network equipment and interconnects locally managed. LANs facilitate the distribution of da ...
(LAN) PHY. The WAN PHY can drive maximum link distances up to 80 km depending on the fiber standard employed. The WAN PHY uses the same 10GBASE-S, 10GBASE-L and 10GBASE-E optical PMDs as the LAN PHYs and is designated as 10GBASE-SW, 10GBASE-LW or 10GBASE-EW. Its 64b/66b PCS is defined in IEEE 802.3 clause 49 and its PMD sublayers in clause 52. It also uses a WAN interface sublayer (WIS) defined in clause 50 which adds extra encapsulation to format the frame data to be compatible with SONET STS-192c.


Notes


See also

* 10G * GG45 * List of interface bit rates *
Optical communication Optical communication, also known as optical telecommunication, is communication at a distance using light to carry information. It can be performed visually or by using electronic devices. The earliest basic forms of optical communication date ...
*
Optical fiber cable A fiber-optic cable, also known as an optical-fiber cable, is an assembly similar to an electrical cable but containing one or more optical fibers that are used to carry light. The optical fiber elements are typically individually coated with p ...
* Parallel optical interface * TERA * XAUI


References

*


External links


Ethernet Alliance website

World's First Independent 10GBASE-T Comparative Test Study
{{Ethernet Ethernet standards