Secondary-ion mass spectrometry (SIMS) is a technique used to analyze the composition of solid surfaces and
thin film A thin film is a layer of material ranging from fractions of a nanometer ( monolayer) to several micrometers in thickness. The controlled synthesis of materials as thin films (a process referred to as deposition) is a fundamental step in many ...
s by sputtering the surface of the specimen with a focused primary
ion beam An ion beam is a type of charged particle beam consisting of ions. Ion beams have many uses in electronics manufacturing (principally ion implantation) and other industries. A variety of ion beam sources exists, some derived from the mercu ...
and collecting and analyzing ejected secondary ions. The mass/charge ratios of these secondary ions are measured with a
mass spectrometer Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a '' mass spectrum'', a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is us ...
to determine the elemental, isotopic, or molecular composition of the surface to a depth of 1 to 2 nm. Due to the large variation in ionization probabilities among elements sputtered from different materials, comparison against well-calibrated standards is necessary to achieve accurate quantitative results. SIMS is the most sensitive surface analysis technique, with elemental detection limits ranging from parts per million to parts per billion.


History

In 1910 British physicist J. J. Thomson observed a release of positive ions and neutral atoms from a solid surface induced by ion bombardment. Improved
vacuum pump A vacuum pump is a device that draws gas molecules from a sealed volume in order to leave behind a partial vacuum. The job of a vacuum pump is to generate a relative vacuum within a capacity. The first vacuum pump was invented in 1650 by Otto ...
technology in the 1940s enabled the first prototype experiments on SIMS by Herzog and Viehböck in 1949, at the
University of Vienna The University of Vienna (german: Universität Wien) is a public research university located in Vienna, Austria. It was founded by Duke Rudolph IV in 1365 and is the oldest university in the German-speaking world. With its long and rich hi ...
, Austria. In the mid-1950s Honig constructed a SIMS instrument at RCA Laboratories in Princeton, New Jersey. Then in the early 1960s two SIMS instruments were developed independently. One was an American project, led by Liebel and Herzog, which was sponsored by
NASA The National Aeronautics and Space Administration (NASA ) is an independent agency of the US federal government responsible for the civil space program, aeronautics research, and space research. NASA was established in 1958, succeedin ...
at GCA Corp, Massachusetts, for analyzing
moon rock Moon rock or lunar rock is rock originating from Earth's Moon. This includes lunar material collected during the course of human exploration of the Moon, and rock that has been ejected naturally from the Moon's surface and landed on Earth a ...
s, the other at the University of Paris-Sud in Orsay by R. Castaing for the PhD thesis of G. Slodzian. These first instruments were based on a magnetic double focusing sector field mass spectrometer and used argon for the primary beam ions. In the 1970s, K. Wittmaack and C. Magee developed SIMS instruments equipped with quadrupole mass analyzers. Around the same time, A. Benninghoven introduced the method of static SIMS, where the primary ion current density is so small that only a negligible fraction (typically 1%) of the first surface layer is necessary for surface analysis. Instruments of this type use pulsed primary ion sources and time-of-flight mass spectrometers and were developed by Benninghoven, Niehuis and Steffens at the
University of Münster The University of Münster (german: Westfälische Wilhelms-Universität Münster, WWU) is a public research university located in the city of Münster, North Rhine-Westphalia in Germany. With more than 43,000 students and over 120 fields of stud ...
,
Germany Germany,, officially the Federal Republic of Germany, is a country in Central Europe. It is the second most populous country in Europe after Russia, and the most populous member state of the European Union. Germany is situated betwee ...
and also by Charles Evans & Associates. The Castaing and Slodzian design was developed in the 1960s by the French company CAMECA S.A.S. and used in materials science and
surface science Surface science is the study of physical and chemical phenomena that occur at the interface of two phases, including solid– liquid interfaces, solid– gas interfaces, solid–vacuum interfaces, and liquid– gas interfaces. It includes th ...
. Recent developments are focusing on novel primary ion species like C60+, ionized clusters of
gold Gold is a chemical element with the symbol Au (from la, aurum) and atomic number 79. This makes it one of the higher atomic number elements that occur naturally. It is a bright, slightly orange-yellow, dense, soft, malleable, and ductile ...
and
bismuth Bismuth is a chemical element with the symbol Bi and atomic number 83. It is a post-transition metal and one of the pnictogens, with chemical properties resembling its lighter group 15 siblings arsenic and antimony. Elemental bismuth occurs ...
, or large gas cluster ion beams (e.g., Ar700+). The sensitive high-resolution ion microprobe (SHRIMP) is a large-diameter, double-focusing SIMS
sector instrument A sector instrument is a general term for a class of mass spectrometer that uses a static electric (E) or magnetic (B) sector or some combination of the two (separately in space) as a mass analyzer. Popular combinations of these sectors have bee ...
based on the Liebl and Herzog design, and produced by Australian Scientific Instruments in
Canberra, Australia Canberra ( ) is the capital city of Australia. Founded following the federation of the colonies of Australia as the seat of government for the new nation, it is Australia's largest inland city and the eighth-largest city overall. The c ...
.


Instrumentation

A secondary ion mass spectrometer consists of (1) a primary ion gun generating the primary
ion beam An ion beam is a type of charged particle beam consisting of ions. Ion beams have many uses in electronics manufacturing (principally ion implantation) and other industries. A variety of ion beam sources exists, some derived from the mercu ...
, (2) a primary ion column, accelerating and focusing the beam onto the sample (and in some devices an opportunity to separate the primary ion species by
Wien filter A Wien filter also known as velocity selector is a device consisting of perpendicular electric and magnetic fields that can be used as a velocity filter for charged particles, for example in electron microscopes and spectrometers. It is used in ...
or to pulse the beam), (3) high
vacuum A vacuum is a space devoid of matter. The word is derived from the Latin adjective ''vacuus'' for "vacant" or " void". An approximation to such vacuum is a region with a gaseous pressure much less than atmospheric pressure. Physicists often ...
sample chamber holding the sample and the secondary ion extraction lens, (4) a mass analyser separating the ions according to their mass-to-charge ratio, and (5) a detector.


Vacuum

SIMS requires a high vacuum with pressures below 10−4 Pa (roughly 10−6
mbar The bar is a metric unit of pressure, but not part of the International System of Units (SI). It is defined as exactly equal to 100,000  Pa (100 kPa), or slightly less than the current average atmospheric pressure on Earth at sea l ...
or
torr The torr (symbol: Torr) is a unit of pressure based on an absolute scale, defined as exactly of a standard atmosphere (). Thus one torr is exactly (≈ ). Historically, one torr was intended to be the same as one " millimeter of merc ...
). This is needed to ensure that secondary ions do not collide with background gases on their way to the detector (i.e. the
mean free path In physics, mean free path is the average distance over which a moving particle (such as an atom, a molecule, or a photon) travels before substantially changing its direction or energy (or, in a specific context, other properties), typically as ...
of gas molecules within the detector must be large compared to the size of the instrument), and it also limits surface contamination by
adsorption Adsorption is the adhesion of atoms, ions or molecules from a gas, liquid or dissolved solid to a surface. This process creates a film of the ''adsorbate'' on the surface of the ''adsorbent''. This process differs from absorption, in which a ...
of background gas particles during measurement.


Primary ion source

Three types of ion guns are employed. In one, ions of gaseous elements are usually generated with
duoplasmatron The Duoplasmatron is an ion source in which a cathode filament emits electrons into a vacuum chamber. A gas such as argon is introduced in very small quantities into the chamber, where it becomes charged or ionized through interactions with the ...
s or by
electron ionization Electron ionization (EI, formerly known as electron impact ionization and electron bombardment ionization) is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of t ...
, for instance
noble gas The noble gases (historically also the inert gases; sometimes referred to as aerogens) make up a class of chemical elements with similar properties; under standard conditions, they are all odorless, colorless, monatomic gases with very low ch ...
es (40 Ar+, Xe+),
oxygen Oxygen is the chemical element with the symbol O and atomic number 8. It is a member of the chalcogen group in the periodic table, a highly reactive nonmetal, and an oxidizing agent that readily forms oxides with most elements ...
(16O, 16O2+, 16O2), or even ionized molecules such as SF5+ (generated from SF6) or C60+ (
fullerene A fullerene is an allotrope of carbon whose molecule consists of carbon atoms connected by single and double bonds so as to form a closed or partially closed mesh, with fused rings of five to seven atoms. The molecule may be a hollow sphere, ...
). This type of ion gun is easy to operate and generates roughly focused but high current ion beams. A second source type, the surface ionization source, generates 133Cs+ primary ions. Cesium atoms vaporize through a porous tungsten plug and are ionized during evaporation. Depending on the gun design, fine focus or high current can be obtained. A third source type, the liquid metal ion gun (LMIG), operates with metals or metallic alloys, which are liquid at room temperature or slightly above. The liquid metal covers a
tungsten Tungsten, or wolfram, is a chemical element with the symbol W and atomic number 74. Tungsten is a rare metal found naturally on Earth almost exclusively as compounds with other elements. It was identified as a new element in 1781 and first isol ...
tip and emits ions under influence of an intense electric field. While a
gallium Gallium is a chemical element with the Symbol (chemistry), symbol Ga and atomic number 31. Discovered by France, French chemist Paul-Émile Lecoq de Boisbaudran in 1875, Gallium is in boron group, group 13 of the periodic table and is similar to ...
source is able to operate with elemental gallium, recently developed sources for
gold Gold is a chemical element with the symbol Au (from la, aurum) and atomic number 79. This makes it one of the higher atomic number elements that occur naturally. It is a bright, slightly orange-yellow, dense, soft, malleable, and ductile ...
,
indium Indium is a chemical element with the symbol In and atomic number 49. Indium is the softest metal that is not an alkali metal. It is a silvery-white metal that resembles tin in appearance. It is a post-transition metal that makes up 0.21 parts ...
and
bismuth Bismuth is a chemical element with the symbol Bi and atomic number 83. It is a post-transition metal and one of the pnictogens, with chemical properties resembling its lighter group 15 siblings arsenic and antimony. Elemental bismuth occurs ...
use alloys which lower their
melting point The melting point (or, rarely, liquefaction point) of a substance is the temperature at which it changes state from solid to liquid. At the melting point the solid and liquid phase exist in equilibrium. The melting point of a substance depen ...
s. The LMIG provides a tightly focused ion beam (<50 nm) with moderate intensity and is additionally able to generate short pulsed ion beams. It is therefore commonly used in static SIMS devices. The choice of the ion species and ion gun respectively depends on the required current (pulsed or continuous), the required beam dimensions of the primary ion beam and on the sample which is to be analyzed. Oxygen primary ions are often used to investigate electropositive elements due to an increase of the generation probability of positive secondary ions, while caesium primary ions often are used when electronegative elements are being investigated. For short pulsed ion beams in static SIMS, LMIGs are most often deployed for analysis; they can be combined with either an oxygen gun or a caesium gun during elemental depth profiling, or with a C60+ or gas cluster ion source during molecular depth profiling.


Mass analyzer

Depending on the SIMS type, there are three basic analyzers available: sector, quadrupole, and time-of-flight. A sector field mass spectrometer uses a combination of an electrostatic analyzer and a magnetic analyzer to separate the secondary ions by their mass-to-charge ratio. A quadrupole mass analyzer separates the masses by resonant electric fields, which allow only the selected masses to pass through. The time of flight mass analyzer separates the ions in a field-free drift path according to their velocity. Since all ions possess the same kinetic energy the velocity and therefore time of flight varies according to mass. It requires pulsed secondary ion generation using either a pulsed primary ion gun or a pulsed secondary ion extraction. It is the only analyzer type able to detect all generated secondary ions simultaneously, and is the standard analyzer for static SIMS instruments.


Detector

A Faraday cup measures the ion current hitting a metal cup, and is sometimes used for high current secondary ion signals. With an
electron multiplier An electron multiplier is a vacuum-tube structure that multiplies incident charges. In a process called secondary emission, a single electron can, when bombarded on secondary-emissive material, induce emission of roughly 1 to 3 electrons. If an ...
an impact of a single ion starts off an electron cascade, resulting in a pulse of 108 electrons which is recorded directly. A microchannel plate detector is similar to an electron multiplier, with lower amplification factor but with the advantage of laterally-resolved detection. Usually it is combined with a
fluorescent Fluorescence is the emission of light by a substance that has absorbed light or other electromagnetic radiation. It is a form of luminescence. In most cases, the emitted light has a longer wavelength, and therefore a lower photon energy, ...
screen, and signals are recorded either with a CCD-camera or with a fluorescence detector.


Detection limits and sample degradation

Detection limit The limit of detection (LOD or LoD) is the lowest signal, or the lowest corresponding quantity to be determined (or extracted) from the signal, that can be observed with a sufficient degree of confidence or statistical significance. However, the ...
s for most trace elements are between 1012 and 1016 atoms per
cubic centimetre A cubic centimetre (or cubic centimeter in US English) (SI unit symbol: cm3; non-SI abbreviations: cc and ccm) is a commonly used unit of volume that corresponds to the volume of a cube that measures 1 cm × 1 cm × 1 cm. One cu ...
, depending on the type of instrumentation used, the primary ion beam used and the analytical area, and other factors. Samples as small as individual pollen grains and microfossils can yield results by this technique. The amount of surface cratering created by the process depends on the current (pulsed or continuous) and dimensions of the primary ion beam. While only charged secondary ions emitted from the material surface through the sputtering process are used to analyze the chemical composition of the material, these represent a small fraction of the particles emitted from the sample.


Static and dynamic modes

In the field of surface analysis, it is usual to distinguish '' static SIMS'' and ''dynamic SIMS''. Static SIMS is the process involved in surface atomic monolayer analysis, or surface molecular analysis, usually with a pulsed ion beam and a time of flight mass spectrometer, while dynamic SIMS is the process involved in bulk analysis, closely related to the sputtering process, using a DC primary ion beam and a magnetic sector or quadrupole mass spectrometer. Dynamic secondary ion mass spectrometry (DSIMS) is a powerful tool for characterizing surfaces, including the elemental, molecular, and isotopic composition and can be used to study the structure of
thin films A thin film is a layer of material ranging from fractions of a nanometer ( monolayer) to several micrometers in thickness. The controlled synthesis of materials as thin films (a process referred to as deposition) is a fundamental step in many ...
, the composition of
polymer A polymer (; Greek '' poly-'', "many" + '' -mer'', "part") is a substance or material consisting of very large molecules called macromolecules, composed of many repeating subunits. Due to their broad spectrum of properties, both synthetic a ...
s, and the surface chemistry of
catalyst Catalysis () is the process of increasing the rate of a chemical reaction by adding a substance known as a catalyst (). Catalysts are not consumed in the reaction and remain unchanged after it. If the reaction is rapid and the catalyst recyc ...
s. DSIMS was developed by
John B. Fenn John Bennett Fenn (June 15, 1917December 10, 2010) was an American professor of analytical chemistry who was awarded a share of the Nobel Prize in Chemistry in 2002. Fenn shared half of the award with Koichi Tanaka for their work in mass spectro ...
and Koichi Tanaka in the early 1980s. DSIMS is mainly used by the
semiconductor industry The semiconductor industry is the aggregate of companies engaged in the design and fabrication of semiconductors and semiconductor devices, such as transistors and integrated circuits. It formed around 1960, once the fabrication of semiconduc ...
.


Applications

The COSIMA instrument onboard
Rosetta Rosetta or Rashid (; ar, رشيد ' ; french: Rosette  ; cop, ϯⲣⲁϣⲓⲧ ''ti-Rashit'', Ancient Greek: Βολβιτίνη ''Bolbitinē'') is a port city of the Nile Delta, east of Alexandria, in Egypt's Beheira governorate. The R ...
was the first instrument to determine the composition of cometary dust in situ with secondary ion mass spectrometry during the spacecraft's 2014–2016 close approaches to comet 67P/Churyumov–Gerasimenko. SIMS is used for quality assurance purposes in the semiconductor industry and for the characterization of natural samples from this planet and others. More recently, this technique is being applied to nuclear forensics. SIMS can be used in the forensics field to develop fingerprints. Since SIMS is a vacuum based method, it is necessary to determine the order of usage along with other methods of analysis for fingerprints. This is because the mass of the fingerprint significantly decreases after exposure to vacuum conditions.


See also

* NanoSIMS


Citations


General bibliography

* Benninghoven, A., Rüdenauer, F. G., Werner, H. W., ''Secondary Ion Mass Spectrometry: Basic Concepts, Instrumental Aspects, Applications, and Trends'', Wiley, New York, 1987 (1227 pages), * Vickerman, J. C., Brown, A., Reed, N. M., ''Secondary Ion Mass Spectrometry: Principles and Applications'', Clarendon Press, Oxford, 1989 (341 pages), * Wilson, R. G., Stevie, F. A., Magee, C. W., ''Secondary Ion Mass Spectrometry: A Practical Handbook for Depth Profiling and Bulk Impurity Analysis'', John Wiley & Sons, New York, 1989, * Vickerman, J. C., Briggs, D., ''ToF-SIMS: Surface Analysis by Mass Spectrometry', IM Publications, Chichester UK and SurfaceSpectra, Manchester, UK, 2001 (789 pages), * Bubert, H., Jenett, H., 'Surface and Thin Film Analysis: A Compendium of Principles, Instrumentation, and Applications'', pp. 86–121, Wiley-VCH, Weinheim, Germany, 2002,


External links

* Tutorial pages for SIM
theory
an
instrumentation
{{Mass spectrometry Mass spectrometry Semiconductor analysis