Internal dosimetry
   HOME

TheInfoList



OR:

Internal dosimetry is the science and art of internal
ionising radiation Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can t ...
dose assessment due to radionuclides incorporated inside the human body. Radionuclides deposited within a body will irradiate tissues and organs and give rise to
committed dose The committed dose in radiological protection is a measure of the stochastic health risk due to an intake of radioactive material into the human body. Stochastic in this context is defined as the ''probability'' of cancer induction and genetic dam ...
until they are excreted from the body or the radionuclide is completely decayed. The internal doses for workers or members of the public exposed to the intake of radioactive particulates can be estimated using
bioassay A bioassay is an analytical method to determine the concentration or potency of a substance by its effect on living animals or plants (''in vivo''), or on living cells or tissues(''in vitro''). A bioassay can be either quantal or quantitative, dir ...
data such as lung and body counter measurements, urine or faecal radioisotope concentration, etc. The
International Commission on Radiological Protection The International Commission on Radiological Protection (ICRP) is an independent, international, non-governmental organization, with the mission to protect people, animals, and the environment from the harmful effects of ionising radiation. Its r ...
(ICRP) biokinetic models are applied to establish a relationship between the individual intake and the bioassay measurements, and then to infer the internal dose.


Committed dose

The internal radiation dose due to injection, ingestion or inhalation radioactive substances is known as
committed dose The committed dose in radiological protection is a measure of the stochastic health risk due to an intake of radioactive material into the human body. Stochastic in this context is defined as the ''probability'' of cancer induction and genetic dam ...
. The ICRP defines Committed effective dose, as the sum of the products of the committed organ or tissue equivalent doses and the appropriate tissue weighting factors ''W''T, where ''t'' is the integration time in years following the intake. The commitment period is taken to be 50 years for adults, and to age 70 years for children. The ICRP further states "For internal exposure, committed effective doses are generally determined from an assessment of the intakes of radionuclides from bioassay measurements or other quantities (e.g., activity retained in the body or in daily excreta). The radiation dose is determined from the intake using recommended dose coefficients".


Routes of intake

There are a few routes of intake (of radionuclide) namely, *Inhalation *Ingestion *Injection *Absorption In a radioactive area, radionuclide particulate may be suspended in the air and can enter the body by inhalation. These particulates may be deposited in different parts of the respiratory tract depending upon their
aerodynamic diameter An aerosol is a suspension of fine solid particles or liquid droplets in air or another gas. Aerosols can be natural or anthropogenic. Examples of natural aerosols are fog or mist, dust, forest exudates, and geyser steam. Examples of anthropo ...
.


Monitoring techniques

In-vivo monitoring
Internal dose monitoring of the radionuclides which emit radiation which can penetrate out of the body. For example X-rays, gamma rays of sufficient energy. It can be measured by devices such as a whole body counter. A whole body counter has a low background arrangement with counting systems *NaI(Tl) detectors for high energy photon detection *Phoswich detectors with Be window and thin NaI(Tl)crystal and thick CsI(Tl)or CsI(Na), for low energy (<100 keV) photon detection HPGe detectors are replacing detectors for measuring the low energy and high energy photons with appropriate electronic systems.
Calibration of these systems is carried out with different type of physical and mathematical phantoms. Physical phantoms include BOMAB, LLNL, JAERI, thyroid and the knee phantoms. Some of the renowned mathematical phantoms are MIRD, CRISTY and nowadays voxel phantoms also known as Computational human phantoms. In-vitro monitoring

Monitoring of the radionuclides present in the body using the bio-assay sample taken out of the body; this includes samples of urine, sweat, feces, etc.


Biokinetic modelling

The ICRP models are used to simulate the distribution of the isotopes inside the human being. All current ICRP models, compiled in the OIR (ICRP134/137) data viewer, can be represented by compartmental systems with constant coefficients. The conceptual model used by ICRP can be summarized as it follows. The human body can be divided into three systems: a) The human respiratory tract model (HRTM). This model is applied for modeling the intake of radioactive aerosols by inhalation. The detailed description is given in ICRP 130 (2016) updating the ICRP 66 (1994). If a person inhales instantaneously a quantity I, it is deposited directly in some compartments of the HRTM. The fraction deposited in each compartment is called Initial Deposition Fraction or IDF. It is a function of Activity Median Aerodynamic Diameter (AMAD), which includes size, shape, density, anatomical and physiological parameters as well as various conditions of exposure. The IDF values may be calculated either following the procedure described in ICRP 130/66 or obtaining it from their Annex. The general model of the HRTM is common to any element except the absorption rates which are related to the chemical form of the element. ICRP gives default values of absorption rates according to types F, M or S, but specific value for some compounds are available in ICRP 134 and ICRP 137. b) The Human Alimentary Tract Model (HATM). This is applied for modeling the intake of particles in the GI tract following the model provided ICRP 105 (ICRP 2005). Particles can be introduced in the GI Tract directly by ingestion, or from the RT. Deposition is in the stomach (ST). Part or all the flow is transferred, through SI, to the blood (B). The rate transfer from SI to B, is given by fA. The value of fA is associated to the element and their chemical form. c) Systemic compartments. They are specific compartments to be applied for an element. Current models are described in ICRP 134 and ICRP 137. A few computer codes have been developed to estimate intake and calculate internal dose using biassay data.


Bioassay evaluations

Biokinetic modeling is widely used in internal dosimetry and to evaluate
bioassay A bioassay is an analytical method to determine the concentration or potency of a substance by its effect on living animals or plants (''in vivo''), or on living cells or tissues(''in vitro''). A bioassay can be either quantal or quantitative, dir ...
data. Computer programs can be used for bioassay evaluations. The bioassay measurement values can be used to estimate unknown intake.Optimal design and mathematical model applied to establish bioassay programs
/ref>


See also

*
Committed dose The committed dose in radiological protection is a measure of the stochastic health risk due to an intake of radioactive material into the human body. Stochastic in this context is defined as the ''probability'' of cancer induction and genetic dam ...
*
Sievert The sievert (symbol: SvNot be confused with the sverdrup or the svedberg, two non-SI units that sometimes use the same symbol.) is a unit in the International System of Units (SI) intended to represent the stochastic health risk of ionizing rad ...
- the measure of health effect due to low radiation doses. Also contains a description of the various dose quantities.


References


External links


ICRP website
{{Radiation protection, state=uncollapsed Nuclear safety and security Nuclear medicine Radiation protection