Earth leakage circuit breaker
   HOME

TheInfoList



OR:

An earth-leakage circuit breaker (ELCB) is a safety device used in electrical installations with high Earth impedance to prevent shock. It detects small stray voltages on the metal enclosures of electrical equipment, and interrupts the circuit if a dangerous voltage is detected. Once widely used, more recent installations instead use
residual-current device A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) is an electrical safety device that quickly breaks an electrical circuit with leakage current to ground. It is to protect equi ...
s (RCDs, RCCBs or GFCIs) which instead detect leakage current directly.


Purpose

The main purpose of Earth leakage protectors is to prevent injury to humans and animals due to electric shock.


History

This is a category of devices, which are used to protect instruments, circuits and operators, while Earth leakage. Early ELCBs were voltage operated devices (VO-ELCB), detecting a voltage rise between installation metalwork, and an external electrode. These have now been replaced by current sensing devices (RCD/RCCB). In modern literature voltage sensing devices are called ELCB or VOELCB and current sensing devices are called RCCB or RCD. Voltage sensing ELCBs were first introduced about sixty years ago. Current sensing ELCBs were first introduced about forty years ago. For many years, the voltage operated ELCB and the differential current operated ELCB were both referred to as ELCBs because it was a simpler name to remember. But the use of a common name for two different devices gave rise to considerable confusion in the electrical industry. If the wrong type was used on an installation, the level of protection given could be substantially less than that intended, in particular the voltage operated type can only protect against faults or shocks to metalwork connected to the circuit ground, connected to the VOELCB, it cannot detect current leaving a live wire and running to ground by another path, such as via a person standing on the earth. To eliminate this confusion, the
IEC The International Electrotechnical Commission (IEC; in French: ''Commission électrotechnique internationale'') is an international standards organization that prepares and publishes international standards for all electrical, electronic and r ...
decided to apply the term residual current device (RCD) to differential-current-operated ELCBs. Residual current refers to any residue when comparing current in the outbound and return currents in the circuit. In a single phase circuit this is simply the live or phase current minus the neutral current. In a 3 phase circuit all current carrying conductors must be sensed.


Operation

An ELCB is a specialised type of
latching relay A relay Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off A relay is an electrically operated switch ...
that has a building's incoming mains power connected through its switching contacts so that the ELCB disconnects the power when earth leakage is detected. The ELCB detects
fault current In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a f ...
s from live to the Earth (ground) wire within the installation it protects. If sufficient
voltage Voltage, also known as electric pressure, electric tension, or (electric) potential difference, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to ...
appears across the ELCB's sense coil, it will switch off the
power Power most often refers to: * Power (physics), meaning "rate of doing work" ** Engine power, the power put out by an engine ** Electric power * Power (social and political), the ability to influence people or events ** Abusive power Power may a ...
, and remain off until manually reset. A voltage-sensing ELCB does not sense fault currents from live to any other Earthed body.


Types

There are two types of Earth-leakage circuit breaker: *
voltage Voltage, also known as electric pressure, electric tension, or (electric) potential difference, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to ...
operated (referred as ELCB in this article) and, *
current Currents, Current or The Current may refer to: Science and technology * Current (fluid), the flow of a liquid or a gas ** Air current, a flow of air ** Ocean current, a current in the ocean *** Rip current, a kind of water current ** Current (stre ...
operated (referred to as RCCB in this article).


Voltage-operated (ELCB)

Voltage ELCBs have been in widespread use since then, and many are still in operation but are no longer installed in new construction. A voltage-operated ELCB detects a rise in potential between the protected interconnected metalwork (equipment frames, conduits, enclosures) and a distant isolated Earth reference electrode. They operate at a detected potential of around 50 volts to open a main breaker and isolate the supply from the protected premises.Christopher Shelton, ''Electrical installations third edition'', Nelson Thornes, 2004 page 233 A voltage-operated ELCB has a second terminal for connecting to the remote reference Earth connection. The Earth circuit is modified when an ELCB is used; the connection to the Earth rod is passed through the ELCB by connecting to its two Earth terminals. One terminal goes to the installation Earth CPC ( circuit protective conductor, aka Earth wire), and the other to the Earth rod (or sometimes other type of Earth connection).


Disadvantages

Compared with a current-sensing system, voltage sensing systems have several disadvantages which include: * A wire break in the fault to load section, or in the earth to ground section, will disable operation of the ELCB. * Requirement of an additional third wire from the load to the ELCB. * Separate devices cannot be grounded individually. * Any additional connection to Earth on the protected system can disable the detector. * The ELCB senses equipment faults and cannot detect if a person accidentally touches an energized part of the ELCB.


Current sensing devices (RCD/RCCB)

RCD/RCCB is the commonly used ELCB type. An RCCB typically consists of a
current transformer A current transformer (CT) is a type of transformer that is used to reduce or multiply an alternating current (AC). It produces a current in its secondary which is proportional to the current in its primary. Current transformers, along with volt ...
, which has multiple primary windings and one secondary winding. Neutral and line (or lines in multiple phase systems) wires act as the primary windings. A wire wound coil is the secondary winding. The current through the secondary winding is zero at the balanced condition. In the balanced condition, the flux due to the current through the phase wire will be neutralized by the current through the neutral wire, since the current, which flows from the phase will be returned to the neutral. When a fault occurs, a small current will flow to the ground also. This makes an imbalance between line and neutral current creating an unbalanced magnetic field. This induces a current through the secondary winding, which is connected to the sensing circuit. This will sense the leakage and send signal to tripping system.


Voltage Sensing Advantages

Voltage sensing ELCBs have a few advantages over current sensing RCDs: 1) They are less sensitive to fault conditions, and therefore have fewer nuisance trips. (This does not mean they always do, as practical performance depends on installation details and the discrimination enhancing filtering in the ELCB.) Therefore, by electrically separating cable armour from the cable circuit protective conductor, an ELCB can be arranged to protect against cable damage only, and not trip on faults in downline installations. 2) Voltage sensing ELCBs will also trip on DC current faults to ground which a transformer interfaced RCD/RCCB is unable to sense, with similar issues with frequencies significantly above mains frequency. This may lead to ground faults on variable speed drives between the drive electronics and motor not being detected for example.


Voltage Sensing Disadvantages

Voltage sensing ELCBs have some disadvantages: * They do not detect faults that do not pass
current Currents, Current or The Current may refer to: Science and technology * Current (fluid), the flow of a liquid or a gas ** Air current, a flow of air ** Ocean current, a current in the ocean *** Rip current, a kind of water current ** Current (stre ...
through the CPC to the Earth rod. * They do not allow a single
building A building, or edifice, is an enclosed structure with a roof and walls standing more or less permanently in one place, such as a house or factory (although there's also portable buildings). Buildings come in a variety of sizes, shapes, and fu ...
system to be easily split into multiple sections with independent fault protection, because
Earthing system An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the Earth's conductive surface, for safety and functional purposes. The choice of earthing system can affect ...
s are usually bonded to
pipework Within industry, piping is a system of pipes used to convey fluids (liquids and gases) from one location to another. The engineering discipline of piping design studies the efficient transport of fluid. Industrial process piping (and accompa ...
. * They may be tripped by external voltages from something connected to the Earthing system such as metal pipes, a
TN-S An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the Earth's conductive surface, for safety and functional purposes. The choice of earthing system can affect ...
Earth or a TN-C-S combined neutral and Earth. * As with RCDs, electrically leaky appliances such as some water heaters,
washing machine A washing machine (laundry machine, clothes washer, washer, or simply wash) is a home appliance used to wash laundry. The term is mostly applied to machines that use water as opposed to dry cleaning (which uses alternative cleaning fluids and ...
s and
cooker Cooker may refer to several types of cooking appliances and devices used for cooking foods. Cookers * AGA cooker – a heat storage stove and cooker, which works on the principle that a heavy frame made from cast iron components can absorb hea ...
s may cause the ELCB to trip. * ELCBs introduce additional resistance and an additional point of failure into the
Earthing system An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the Earth's conductive surface, for safety and functional purposes. The choice of earthing system can affect ...
.


Earth bypassing

It is not unusual for an ELCB protected installation to have a second unintentional connection to Earth somewhere, one that does not pass through the ELCB sense coil. This can occur via metal pipework in contact with the ground,
metal A metal (from Greek μέταλλον ''métallon'', "mine, quarry, metal") is a material that, when freshly prepared, polished, or fractured, shows a lustrous appearance, and conducts electricity and heat relatively well. Metals are typicall ...
structural framework, outdoor
home appliance A home appliance, also referred to as a domestic appliance, an electric appliance or a household appliance, is a machine which assists in household functions such as cooking, cleaning and food preservation. Appliances are divided into three ...
s in contact with
soil Soil, also commonly referred to as earth or dirt Dirt is an unclean matter, especially when in contact with a person's clothes, skin, or possessions. In such cases, they are said to become dirty. Common types of dirt include: * Debri ...
, and so on. When this occurs, fault current may pass to
Earth Earth is the third planet from the Sun and the only astronomical object known to harbor life. While large volumes of water can be found throughout the Solar System, only Earth sustains liquid surface water. About 71% of Earth's surfa ...
without being sensed by the ELCB. Despite this, perhaps counterintuitively, the operation of the ELCB is not compromised. The purpose of the ELCB is to prevent Earthed
metalwork Metalworking is the process of shaping and reshaping metals to create useful objects, parts, assemblies, and large scale structures. As a term it covers a wide and diverse range of processes, skills, and tools for producing objects on every scale ...
rising to a dangerous
voltage Voltage, also known as electric pressure, electric tension, or (electric) potential difference, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to ...
during fault conditions, and the ELCB continues to do this just the same, the ELCB will still cut the power at the same CPC voltage level. (The difference is that higher fault current is then needed to reach this voltage.)


Nuisance trips

While voltage and current on the earth line is usually fault current from a live wire, this is not always the case, thus there are situations in which an ELCB can nuisance trip. When an installation has two connections to Earth, a nearby high current
lightning Lightning is a naturally occurring electrostatic discharge during which two electrically charged regions, both in the atmosphere or with one on the ground, temporarily neutralize themselves, causing the instantaneous release of an avera ...
strike will cause a voltage gradient in the soil, presenting the ELCB sense coil with enough voltage to cause it to trip. If the installation's Earth rod is placed close to the Earth rod of a neighbouring building, a high Earth leakage current in the other building can raise the local ground potential and cause a voltage difference across the two Earths, again tripping the ELCB. Close Earth rods are unsuitable for ELCB use for this reason, but in real life such installations are sometimes encountered. Both RCDs and ELCBs are prone to
nuisance Nuisance (from archaic ''nocence'', through Fr. ''noisance'', ''nuisance'', from Lat. ''nocere'', "to hurt") is a common law tort. It means that which causes offence, annoyance, trouble or injury. A nuisance can be either public (also "common") ...
trips from normal harmless Earth leakage to some degree. On one hand ELCBs are on average older, and hence tend to have less well developed filtering against nuisance trips, and on the other hand ELCBs are inherently immune to some of the causes of false trips RCDs suffer, and are generally less sensitive than RCDs. In practice RCD nuisance trips are much more common. Another cause of nuisance tripping is due to accumulated or burden currents caused by items with lowered insulation resistance. This may occur due to older equipment, or equipment with heating elements, or even wiring in buildings in the tropics where prolonged damp and rain conditions can cause the insulation resistance to lower due to moisture tracking. If there is a 30 mA protective device in use and there is a 10 mA burden from various sources then the unit will trip at 20 mA. The individual items may each be electrically safe but a large number of small burden currents accumulates and reduces the tripping level. This was more a problem in past installations where multiple circuits were protected by a single ELCB. Heating elements of the tubular form are filled with a very fine powder that can absorb moisture if the element has not be used for some time. In the tropics, this may occur, for example if a clothes drier has not been used for a year or a large water boiler used for coffee, etc. has been in storage. In such cases, if the unit is allowed to power up without RCD protection then it will normally dry out and successfully pass inspection. This type of problem can be seen even with brand new equipment.


Failure to respond

Some ELCBs do not respond to rectified fault current. This issue is the same in principle with ELCBs and RCDs, but ELCBs are on average much older and specifications have improved considerably over the years, so an old ELCB is more likely to have some fault current waveform that it will not respond to. With any mechanical device, failures occur, and ELCBs should ideally be tested periodically to ensure they still work. If either of the Earth wires become disconnected from the ELCB, it will no longer trip and the installation will often no longer be properly Earthed.


See also

*
Residual-current device A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) is an electrical safety device that quickly breaks an electrical circuit with leakage current to ground. It is to protect equi ...
*
Earthing system An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the Earth's conductive surface, for safety and functional purposes. The choice of earthing system can affect ...


References

{{Electricity delivery Electric power distribution Electric power systems components Safety switches ja:配線用遮断器#漏電遮断器