E-6 process
   HOME

TheInfoList



OR:

The E-6 process (often abbreviated to E-6) is a chromogenic photographic process for developing Ektachrome, Fujichrome and other color reversal (also called slide or transparency)
photographic film Photographic film is a strip or sheet of transparent film base coated on one side with a gelatin emulsion containing microscopically small light-sensitive silver halide crystals. The sizes and other characteristics of the crystals determine ...
. Unlike some color reversal processes (such as
Kodachrome Kodachrome is the brand name for a color reversal film introduced by Eastman Kodak in 1935. It was one of the first successful color materials and was used for both cinematography and still photography. For many years Kodachrome was widely used ...
K-14) that produce positive transparencies, E-6 processing can be performed by individual users with the same equipment that is used for processing black and white negative film or C-41 color negative film. The process is highly sensitive to temperature variations: A heated water bath is mandatory to stabilize the temperature at 100.0 °F (37.8 °C) for the first developer and first wash to maintain process tolerances.


History

The E-6 process superseded
Kodak The Eastman Kodak Company (referred to simply as Kodak ) is an American public company that produces various products related to its historic basis in analogue photography. The company is headquartered in Rochester, New York, and is incorpor ...
's E-3 and E-4 processes. The E-3 process required fogging with light to accomplish image reversal and produced transparencies that faded quickly. The E-4 process used polluting chemicals, such as the highly toxic reversal agent borane tert-butylamine (TBAB).


Process variations

There are two versions of the E-6 process. Commercial laboratories use a six-bath chemical process. The 'hobby' type chemistry kits, such as those produced by Tetenal, use three chemical baths that combine the color developer and fogging bath solutions, and the pre-bleach, bleach and fixer bath solutions.


Six-bath process version

The steps for developing color transparency films using process E6 are: * First developer bath: 6:00 @ 100.0 °F (37.8 °C). This uses a
potassium hydroquinone monosulfonate Potassium is the chemical element with the symbol K (from Neo-Latin ''kalium'') and atomic number19. Potassium is a silvery-white metal that is soft enough to be cut with a knife with little force. Potassium metal reacts rapidly with atmosphe ...
-
phenidone Phenidone (1-phenyl-3-pyrazolidinone) is an organic compound that is primarily used as a photographic developer. It has five to ten times the developing power as Metol. It also has low toxicity and unlike some other developers, does not cause derm ...
black & white film developer, with the preferred form of phenidone being 4-hydroxymethyl-4-methyl-1-phenyl-3-pyrazolidinone (13047-13-7). The first developer forms a negative silver image in each layer of the film. The first developer is time and temperature sensitive because it controls contrast. * First wash: Water stop bath, 2:00 @ 100.0 °F (37.8 °C). This step once used an acetic acid stop bath, but was replaced with a water-only bath for process economy, with concomitant slight reduction of first developer strength. * Reversal bath: 2:00 @ 96–103 °F (35.6–39.4 °C). This bath prepares the film for the color developer step. A chemical reversal agent is absorbed into the emulsion, which is instantly effective. The reversal step can also be carried out using 800 footcandle-seconds (8.6 klx·s) of light - this variation is used by process engineers to troubleshoot reversal bath chemistry problems such as contamination and issues of low tank turnover as process volumes decline. * Color developer bath: 6:00 @ 96–103 °F (35.6–39.4 °C). This step is carried out to completion. The developer contains CD-3 developing agent, and acts upon the chemically exposed silver halide that was not developed in the first developer to form a positive silver image. The metallic negative silver image formed in the first developer has no part in the reaction of this step. As the color development progresses, a metallic positive silver image is formed and the color developing agent is oxidized. Oxidized color developer molecules react with the color couplers and color dyes are formed in each of the three layers of the film. Each layer of the film contains different color couplers, which react with the same oxidized developer molecules but form different color dyes. Variation in color developer pH causes color shifts on the green-magenta axis with Kodak E100G & E100GX and Fujichrome films and on the yellow-blue axis with older Ektachrome films. * Pre-bleach bath: 2:00 @ 90–103 °F (32.2–39.4 °C). This bath was previously called "conditioner", but was renamed pre-bleach in the mid-1990s to reflect the removal of formaldehyde from the process used in the final rinse. In this solution,
formaldehyde Formaldehyde ( , ) ( systematic name methanal) is a naturally occurring organic compound with the formula and structure . The pure compound is a pungent, colourless gas that polymerises spontaneously into paraformaldehyde (refer to section ...
acts as a dye preservative and
EDTA Ethylenediaminetetraacetic acid (EDTA) is an aminopolycarboxylic acid with the formula H2N(CH2CO2H)2sub>2. This white, water-soluble solid is widely used to bind to iron (Fe2+/Fe3+) and calcium ions (Ca2+), forming water-soluble complexes ev ...
is used to "kick off" the bleach. The pre-bleach bath relies on carry-over of the color developer to function properly, therefore there is no wash step between the color developer and pre-bleach baths. * Bleach bath: 6:00 @ 92–103 °F (33.3–39.4 °C). This is a process-to-completion step, and relies on carry-over of pre-bleach to initiate the bleach. The bleach converts metallic silver into
silver bromide Silver bromide (AgBr) is a soft, pale-yellow, water-insoluble salt well known (along with other silver halides) for its unusual sensitivity to light. This property has allowed silver halides to become the basis of modern photographic materials. A ...
, which is converted to soluble silver compounds by the fixer. During bleaching, iron (III) EDTA is converted to iron (II) EDTA (Fe3+ EDTA + Ag + Br→ Fe2+ EDTA + AgBr) before fixing. Kodak also has a process variant which uses a higher concentration of bleach and a 4:00 bath time; but with process volumes declining, this variant has become uneconomical. * Wash step (optional): Rinses off the bleach and extends the life of the fixer bath. This wash step is recommended for rotary tube, sink line and other low volume processing. * Fixer bath: 4:00 @ 92–103 °F (33.3–39.4 °C). This is a process-to-completion step. * Second fixer stage (optional): Using fresh fixer. The archival properties of film and paper are greatly improved using a second fixing stage in a reverse cascade. Note that this is the Photo.Net discussion thread of the 1998 technical paper by Dr. Michael J. Gudzinowicz. Many C-41RA (rapid access) minilab processors also use 2 stage reverse cascade fixing for faster throughput. * Final wash: 4:00 @ 92–103 °F (33.3–39.4 °C). * Final rinse: 1:00 @ 80–103 °F (26.7–39.4 °C). Up until the mid-1990s, the final rinse was called a stabilizer bath, since it contained
formaldehyde Formaldehyde ( , ) ( systematic name methanal) is a naturally occurring organic compound with the formula and structure . The pure compound is a pungent, colourless gas that polymerises spontaneously into paraformaldehyde (refer to section ...
. Currently, the final rinse uses a
surfactant Surfactants are chemical compounds that decrease the surface tension between two liquids, between a gas and a liquid, or interfacial tension between a liquid and a solid. Surfactants may act as detergents, wetting agents, emulsion#Emulsifiers , ...
, and miconazole, an anti-fungal agent. * Drying: Drying in a dust-free environment.


See also

* Replenishment (photography)


References


External links


Kodak Process E-6 Publication Z-119

Kodak Q-LAB Process Control Handbook
- more details than processing manual Z-119
Kodak Professional First Developer Replenisher, Process E-6
(PDF) * FujiFilm US
Product Bulletin Library
technical data sheets
E-6 Ektachrome
DIY processing super-8 & 16mm. {{DEFAULTSORT:E-6 Process Photographic film processes