Digital radiography is a form of
radiography Radiography is an imaging technique using X-rays, gamma rays, or similar ionizing radiation and non-ionizing radiation to view the internal form of an object. Applications of radiography include medical radiography ("diagnostic" and "therapeu ...
that uses x-ray–sensitive plates to directly capture data during the patient examination, immediately transferring it to a computer system without the use of an intermediate cassette. Advantages include time efficiency through bypassing chemical processing and the ability to digitally transfer and enhance images. Also, less
radiation In physics, radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium. This includes: * ''electromagnetic radiation'', such as radio waves, microwaves, infrared, visi ...
can be used to produce an image of similar contrast to conventional radiography. Instead of X-ray film, digital radiography uses a digital image capture device. This gives advantages of immediate image preview and availability; elimination of costly film processing steps; a wider dynamic range, which makes it more forgiving for over- and under-exposure; as well as the ability to apply special image processing techniques that enhance overall display quality of the image.


Detectors


Flat panel detectors

250px, Flat panel detector used in digital radiography Flat panel detectors (FPDs) are the most common kind of direct digital detectors. They are classified in two main categories: 1. Indirect FPDs
Amorphous silicon Amorphous silicon (a-Si) is the non-crystalline form of silicon used for solar cells and thin-film transistors in LCDs. Used as semiconductor material for a-Si solar cells, or thin-film silicon solar cells, it is deposited in thin films ont ...
(a-Si) is the most common material of commercial FPDs. Combining a-Si detectors with a
scintillator A scintillator is a material that exhibits scintillation, the property of luminescence, when excited by ionizing radiation. Luminescent materials, when struck by an incoming particle, absorb its energy and scintillate (i.e. re-emit the absorbe ...
in the detector’s outer layer, which is made from caesium iodide (CsI) or
gadolinium oxysulfide Gadolinium oxysulfide ( Gd2 O2 S), also called gadolinium sulfoxylate, GOS or Gadox, is an inorganic compound, a mixed oxide-sulfide of gadolinium. Uses The main use of gadolinium oxysulfide is in ceramic scintillators. Scintillators are used in ...
(Gd2O2S), converts X-rays to light. Because of this conversion the a-Si detector is considered an indirect imaging device. The light is channeled through the a-Si photodiode layer where it is converted to a digital output signal. The digital signal is then read out by thin film transistors (TFTs) or fiber-coupled CCDs. 2. Direct FPDs. Amorphous
selenium Selenium is a chemical element with the symbol Se and atomic number 34. It is a nonmetal (more rarely considered a metalloid) with properties that are intermediate between the elements above and below in the periodic table, sulfur and tellurium, ...
(a-Se) FPDs are known as “direct” detectors because X-ray
photon A photon () is an elementary particle that is a quantum of the electromagnetic field, including electromagnetic radiation such as light and radio waves, and the force carrier for the electromagnetic force. Photons are massless, so they alwa ...
s are converted directly into charge. The outer layer of the flat panel in this design is typically a high-voltage bias electrode. X-ray photons create
electron-hole pairs In the solid-state physics of semiconductors, carrier generation and carrier recombination are processes by which mobile charge carriers ( electrons and electron holes) are created and eliminated. Carrier generation and recombination processes a ...
in a-Se, and the transit of these electrons and holes depends on the potential of the bias voltage charge. As the holes are replaced with electrons, the resultant charge pattern in the selenium layer is read out by a TFT array, active matrix array, electrometer probes or microplasma line addressing.


Other direct digital detectors

Detectors based on
CMOS Complementary metal–oxide–semiconductor (CMOS, pronounced "sea-moss", ) is a type of metal–oxide–semiconductor field-effect transistor (MOSFET) fabrication process that uses complementary and symmetrical pairs of p-type and n-type MOSF ...
and
charge coupled device A charge-coupled device (CCD) is an integrated circuit containing an array of linked, or coupled, capacitors. Under the control of an external circuit, each capacitor can transfer its electric charge to a neighboring capacitor. CCD sensors are a ...
(CCD) have also been developed, but despite lower costs compared to FPDs of some systems, bulky designs and worse image quality have precluded widespread adoption. A high-density line-scan solid state detector is composed of a photostimulable barium fluorobromide doped with europium (BaFBr:Eu) or caesium bromide (CsBr) phosphor. The phosphor detector records the X-ray energy during exposure and is scanned by a laser diode to excite the stored energy which is released and read out by a digital image capture array of a CCD.


Phosphor plate radiography

Phosphor plate radiography resembles the old analogue system of a light sensitive film sandwiched between two x-ray sensitive screens, the difference being the analogue film has been replaced by an imaging plate with photostimulable phosphor (PSP), which records the image to be read by an image reading device, which transfers the image usually to a Picture archiving and communication system (PACS). It is also called photostimulable phosphor (PSP) plate-based radiography or ''computed radiography'' (not to be confused with computed tomography which uses computer processing to convert multiple projectional radiographies to a
3D image Stereoscopy (also called stereoscopics, or stereo imaging) is a technique for creating or enhancing the illusion of depth in an image by means of stereopsis for binocular vision. The word ''stereoscopy'' derives . Any stereoscopic image is ...
). After X-ray exposure the plate (sheet) is placed in a special scanner where the
latent image {{citations needed, date=November 2015 A latent image is an invisible image produced by the exposure to light of a photosensitive material such as photographic film. When photographic film is developed, the area that was exposed darkens and for ...
is retrieved point by point and digitized, using
laser A laser is a device that emits light through a process of optical amplification based on the stimulated emission of electromagnetic radiation. The word "laser" is an acronym for "light amplification by stimulated emission of radiation". The ...
light scanning. The digitized images are stored and displayed on the computer screen. Phosphor plate radiography has been described as having an advantage of fitting within any pre-existing equipment without modification because it replaces the existing film; however, it includes extra costs for the scanner and replacement of scratched plates. Initially phosphor plate radiography was the system of choice; early DR systems were prohibitively expensive (each cassette costs £40-£50K), and as the 'technology was being taken to the patient', prone to damage. Since there is no physical printout, and after the readout process a digital image is obtained, CR has been known as an indirect digital technology, bridging the gap between x-ray film and fully digital detectors.


Industrial usage


Security

Digital radiography (DR) has existed in various forms (for example, CCD and amorphous Silicon imagers) in the security X-ray inspection field for over 20 years and is steadily replacing the use of film for inspection X-rays in the Security and
nondestructive testing Nondestructive testing (NDT) is any of a wide group of analysis techniques used in science and technology industry to evaluate the properties of a material, component or system without causing damage. The terms nondestructive examination (NDE), n ...
(NDT) fields. DR has opened a window of opportunity for the security NDT industry due to several key advantages including excellent image quality, high POD (probability of detection), portability, environmental friendliness and immediate imaging.


Materials

Nondestructive testing of materials is vital in fields such as
aerospace Aerospace is a term used to collectively refer to the atmosphere and outer space. Aerospace activity is very diverse, with a multitude of commercial, industrial and military applications. Aerospace engineering consists of aeronautics and ast ...
and
electronics The field of electronics is a branch of physics and electrical engineering that deals with the emission, behaviour and effects of electrons using electronic devices. Electronics uses active devices to control electron flow by amplification ...
where integrity of materials is vital for safety and cost reasons. Advantages of digital technologies include the ability to provide results in real time.


History


Key developments


See also

*
Dental radiography Dental radiographs, commonly known as X-rays, are radiographs used to diagnose hidden dental structures, malignant or benign masses, bone loss, and cavities. A radiographic image is formed by a controlled burst of X-ray radiation which penet ...
*
Fluoroscopy Fluoroscopy () is an imaging technique that uses X-rays to obtain real-time moving images of the interior of an object. In its primary application of medical imaging, a fluoroscope () allows a physician to see the internal structure and function ...
* X-ray detectors


References

{{reflist, 30em Projectional radiography