Breathing performance of regulators
   HOME

TheInfoList



OR:

The breathing performance of regulators is a measure of the ability of a breathing gas regulator to meet the demands placed on it at varying ambient pressures and temperatures, and under varying breathing loads, for the range of breathing gases it may be expected to deliver. Performance is an important factor in design and selection of breathing regulators for any application, but particularly for
underwater diving Underwater diving, as a human activity, is the practice of descending below the water's surface to interact with the environment. It is also often referred to as diving, an ambiguous term with several possible meanings, depending on contex ...
, as the range of ambient operating pressures and temperatures, and variety of breathing gases is broader in this application. A
diving regulator A diving regulator is a pressure regulator that controls the pressure of breathing gas for diving. The most commonly recognised application is to reduce pressurized breathing gas to ambient pressure and deliver it to the diver, but there are als ...
is a device that reduces the high pressure in a
diving cylinder A diving cylinder or diving gas cylinder is a gas cylinder used to store and transport high pressure gas used in diving operations. This may be breathing gas used with a scuba set, in which case the cylinder may also be referred to as a sc ...
or surface supply hose to the same pressure as the diver's surroundings. It is desirable that breathing from a regulator requires low effort even when supplying large amounts of
breathing gas A breathing gas is a mixture of gaseous chemical elements and compounds used for respiration. Air is the most common and only natural breathing gas, but other mixtures of gases, or pure oxygen, are also used in breathing equipment and enclosed ...
as this is commonly the limiting factor for underwater exertion, and can be critical during diving emergencies. It is also preferable that the gas is delivered smoothly without any sudden changes in resistance while inhaling or exhaling, and that the regulator does not lock up and either fail to supply gas or free-flow. Although these factors may be judged subjectively, it is convenient to have standards by which the many different types and manufactures of regulators may be objectively compared. Various breathing machines have been developed and used for assessment of breathing apparatus performance. Ansti Test Systems developed a turnkey system that measures the inhalation and exhalation effort in using a regulator, and produces graphs indicating the
work of breathing Work of breathing (WOB) is the energy expended to inhale and exhale a breathing gas. It is usually expressed as work per unit volume, for example, joules/litre, or as a work rate (power), such as joules/min or equivalent units, as it is not parti ...
at the set depth pressure and
respiratory minute volume Minute ventilation (or respiratory minute volume or minute volume) is the volume of gas inhaled (inhaled minute volume) or exhaled (exhaled minute volume) from a person's lungs per minute. It is an important parameter in respiratory medicine due ...
for the gas mixture used. Publishing results of the performance of regulators in the ANSTI test machine has resulted in performance improvements.


Applications

Breathing performance of the regulator is relevant in all circumstances where a demand regulator is used to provide breathing gas. In some of these applications, a very basic regulator will perform adequately. In other applications, the performance of the regulator may limit the performance of the user. A high-performance regulator for a given combination of gas mixture and ambient pressure will provide a low work of breathing at high RMV. Another aspect of breathing performance is demand regulator performance in cold water, where a high flow rate may cause chilling sufficient to lock up the mechanism with ice, which usually causes a severe free-flow with consequent loss of breathing gas, which can only be stopped by shutting off the cylinder valve. *
Scuba diving Scuba diving is a mode of underwater diving whereby divers use breathing equipment that is completely independent of a surface air supply. The name "scuba", an acronym for " Self-Contained Underwater Breathing Apparatus", was coined by Chr ...
– All breathing gas is carried in high-pressure cylinders by the diver **
Recreational scuba diving Recreational diving or sport diving is diving for the purpose of leisure and enjoyment, usually when using scuba equipment. The term "recreational diving" may also be used in contradistinction to "technical diving", a more demanding aspect of ...
– Air and nitrox at ambient pressures up to about 30 msw **
Technical diving Technical diving (also referred to as tec diving or tech diving) is scuba diving that exceeds the agency-specified limits of recreational diving for non-professional purposes. Technical diving may expose the diver to hazards beyond those normally ...
– Ambient pressures may significantly exceed 30 msw ***Mixed gas – Breathing gases containing helium to limit narcosis and work of breathing *** Decompression gas – Breathing gases with high oxygen partial pressures, generally not very high ambient pressure *
Surface-supplied diving Surface-supplied diving is diving using equipment supplied with breathing gas using a diver's umbilical from the surface, either from the shore or from a diving support vessel, sometimes indirectly via a diving bell. This is different from sc ...
– Breathing gas supplied from the surface at a wide range of depths **
Open circuit Open circuit may refer to: *Open-circuit scuba, a type of SCUBA-diving equipment where the user breathes from the set and then exhales to the surroundings without recycling the exhaled air * Open-circuit test, a method used in electrical engineerin ...
– Gas is released into the environment and lost on exhalation ** Breathing gas reclaim systems – Helium based breathing gas is returned to the surface for recycling via an exhaust regulator to save expensive gas *
Built-in breathing system A built-in breathing system is a source of breathing gas installed in a confined space where an alternative to the ambient gas may be required for medical treatment, emergency use, or to minimise a hazard. They are found in diving chambers, hype ...
s in hyperbaric environments – High oxygen content gas is vented to the exterior via an exhaust regulator to avoid high fire risk. High performance not generally needed, as the user is normally resting. * Oxygen administration for first aid in diving accidents – High oxygen fraction at surface pressure, fairly low flow rate, but user may be injured and have difficulty breathing. *Breathing apparatus for work in unbreathable atmospheres – Usually at ambient pressures close to normal atmospheric pressure, breathing air. Work rate can be high but should not be extreme. Positive pressure breathing may be used in toxic atmospheres to reduce risk of contamination due to leaks. **
Self-contained breathing apparatus A self-contained breathing apparatus (SCBA), sometimes referred to as a compressed air breathing apparatus (CABA) or simply breathing apparatus (BA), is a device worn to provide breathable air in an atmosphere that is immediately dangerous to ...
(SCBA) for rescue and firefighting – Users may have to work hard in difficult conditions, but pressure range is generally close to normal atmospheric pressure. Work rate may be extreme in emergencies. Positive pressure masks may be used, which will offset the pressure graph, but not necessarily increase the net work of breathing. *Emergency breathing gas supply in submarines (BIBS) – Survival conditions, at unpredictable pressures. *Oxygen supply for unpressurized aircraft – Low ambient pressure due to high altitude. Air supply enriched by additional oxygen. Flow rate not expected to be very high


Relevance

A healthy person at rest at surface atmospheric pressure expends only a small amount of available effort on breathing. This can change considerably as the density of breathing gas increases at higher ambient pressure. When the energy expended to remove carbon dioxide produces more carbon dioxide than it removes the person will suffer from hypercapnia in a positive feedback cycle ending in unconsciousness and eventually death. Work of breathing is affected by breathing rate, breathing pattern, gas density, physiological factors, and the fluid dynamic details of the breathing apparatus, these being the frictional resistance to flow, and pressure differences required to open valves and hold them open to flow. Breathing gas density can be reduced by using helium as the basic component, with sufficient oxygen added to suit the circumstances and retain a partial pressure sufficient to sustain consciousness but not so much as to cause oxygen toxicity problems. Frictional resistance to flow is influenced by the shape and size of the gas passages, and the pressure, density, viscosity, and velocity of the gas. Valve cracking pressure is a factor of design and settings of the valve mechanisms. The breathing performance of regulators assumes gas density is specified and measures the resistance to flow during the full breathing cycle with a given volumetric flow rate as a pressure drop between the mouthpiece and the exterior environment.


Measurement


Work of breathing

Work of breathing (WOB) is the energy expended to
inhale Inhalation (or Inspiration) happens when air or other gases enter the lungs. Inhalation of air Inhalation of air, as part of the cycle of breathing, is a vital process for all human life. The process is autonomic (though there are exceptions ...
and exhale a breathing gas. It is usually expressed as work per unit volume, for example, joules/litre, or as a work rate (power), such as joules/min or equivalent units, as it is not particularly useful without a reference to volume or time. It can be calculated in terms of the pulmonary pressure multiplied by the change in pulmonary volume, or in terms of the oxygen consumption attributable to breathing. The total work of breathing when using a breathing apparatus is the sum of the physiological work of breathing and the mechanical work of breathing of the apparatus. In a normal resting state the physiological work of breathing constitutes about 5% of the total body oxygen consumption. It can increase considerably due to illness or constraints on gas flow imposed by breathing apparatus, ambient pressure, or breathing gas composition.


Cold water function testing

U.S. Navy Experimental Diving Unit's unmanned cold water test procedures (1994) have been used as an unofficial standard for cold water testing by various military users and major equipment manufacturers. European CE open circuit standard EN 250 of 1993 set a higher level for open circuit scuba testing for breathing performance, cold water testing, proof, pressure, mechanical, storage temperatures, and CO2 wash out tests. The standard also set requirements for failure modes and effects analysis, and other issues relating to manufacturing, quality assurance and documentation. This standard drew attention to issues with a lot of existing equipment, and led to major improvements in open circuit regulator performance. Early testing done by the US Navy was the origin of underwater breathing apparatus simulation testing in the late 1970s. The breathing simulator systems built by Stephen Reimers were bought by the Ministry of Defence in the UK and by some private equipment manufactures like Kirby Morgan Diving Systems, and helped develop European standards in the early 1990s, but the introduction of a complete breathing simulator system by ANSTI Test Systems Ltd in the UK made possible the accurate breathing simulator testing that is the current practice. The computerized ANSTI breathing simulator systems made faster, easier and more accurate testing possible, and are designed for testing in all realistic water temperatures. The system includes precise humidity and exhalation temperature control as well as environmental water temperature control from , facilities for breath by breath CO2 analysis and closed circuit rebreather set point control and scrubber endurance testing. Neither the EN250 standard nor the US Navy unmanned test procedures use any kind of real world human diving scenario as the basis for testing, including cold water testing. The US Navy procedure has been to test regulators primarily at a depth of 190 fsw (58 msw) in water at a very high breathing rate of 62.5 lpm for a minimum of 30 minutes, with inlet pressure to the first stage of , which results in an average second stage inlet temperature of around , compared to an average of if would be used. The US Navy cold water test criteria and the EU EN250 test criteria are based on whether the regulator meets minimum breathing performance requirements and whether or not a free flow starts. Very few regulators can pass this test because all regulators will form ice in the second stage under the extreme test conditions, though this may not cause the regulator to free flow or go outside the performance criteria. The cold water testing specified in EN250:2000 has scuba regulators tested in water or colder. Regulators are tested in both facing forward and facing down positions. The test starts at (50 msw) 165 fsw and the regulator is breathed at 62.5 lpm for five minutes. To pass, the regulator must remain within the
work of breathing Work of breathing (WOB) is the energy expended to inhale and exhale a breathing gas. It is usually expressed as work per unit volume, for example, joules/litre, or as a work rate (power), such as joules/min or equivalent units, as it is not parti ...
limits and must not free flow. The formation of ice is not considered as long as the ice does not degrade the breathing performance beyond minimum performance requirements, and it does not free-flow. The CE test uses an air supply starting at the highest pressure the regulator is rated for and is breathed for five minutes at 62.5 lpm using an exhalation temperature of 28 ±2°C (82.4 ±3.6°F) and an exhalation relative humidity of no less than 90%.


ANSTI machine

The ANSTI Breathing Simulator is rated to a maximum working pressure of 100 msw. It uses a piston mechanism to provide an accurate and repeatable volume displacement with a sine wave drive mechanism. It has adjustable tidal volume and breathing rate settings which can provide ventilation rates from 10 to 180 litres per minute.


EU Standards

In the
European Union The European Union (EU) is a supranational political and economic union of member states that are located primarily in Europe. The union has a total area of and an estimated total population of about 447million. The EU has often been de ...
the standard EN250:2000 ''Respiratory equipment. Open-circuit self-contained compressed air diving apparatus. Requirements, testing, marking'' defines minimum performance standards for "Open-circuit self-contained compressed air diving apparatus", and BS 8547:2016 defines requirements for demand regulators to be used at depths exceeding 50 m. EN 13949: 2003 – Respiratory Equipment – Open Circuit Self-Contained Diving Apparatus for use with Compressed Nitrox and Oxygen – Requirements, Testing, Marking defines requirements for regulators to be used with raised levels of oxygen. The standard contains limits on inhalation and exhalation pressures and overall work of breathing. It specifies the following, under test conditions of a breathing rate of per minute and an ambient pressure of : *Work of breathing: <3.0 joules per litre *Peak respiratory pressure: ±25 mbar (±2.5 kPa) (inhalation or exhalation) *Inhalation work of breathing: <0.3 joule per litre *Pressure spikes with no measurable positive work of breathing: <10 mbar (1 kPa) *Pressure spikes with measurable positive work of breathing: <5 mbar (0.5 kPa) Although a regulator meeting the above limits will supply sufficient air where the first stage feeds a single second stage, it is not necessarily capable of supplying sufficient air in all circumstances when a single first stage feeds two second stages simultaneously.


Related standards

In Europe, EN 250: 2014 – Respiratory Equipment – Open Circuit Self - Contained Compressed Air Diving Apparatus – Requirements, Testing and Marking defines the minimum requirements for breathing performance of regulators, and BS 8547:2016 defines requirements for demand regulators to be used at depths exceeding 50 m. EN 13949: 2003 – Respiratory Equipment – Open Circuit Self-Contained Diving Apparatus for use with Compressed Nitrox and Oxygen – Requirements, Testing, Marking. defines requirements for regulators to be used with raised levels of oxygen. EN 15333 – 1: 2008 COR 2009 – Respiratory Equipment – Open-Circuit Umbilical Supplied Compressed Gas Diving Apparatus – Part 1: Demand Apparatus. and EN 15333 – 2: 2009 – Respiratory Equipment – Open-Circuit Umbilical Supplied Compressed Gas Diving Apparatus – Part 2: Free Flow Apparatus. I.S. EN 14143: 2013 – Respiratory Equipment – Self-Contained Re-Breathing Diving Apparatus defines minimum requirements for rebreathers.


US Military

In the United States Military, the standard for single-hose scuba regulators was MIl-R-24169B, now withdrawn.


See also

* * *


References