HOME

TheInfoList



OR:

A water distribution system is a part of
water supply network A water supply network or water supply system is a system of engineered hydrologic and hydraulic components that provide water supply. A water supply system typically includes the following: # A drainage basin (see water purification – source ...
with components that carry potable water from a centralized treatment plant or
well A well is an excavation or structure created in the ground by digging, driving, or drilling to access liquid resources, usually water. The oldest and most common kind of well is a water well, to access groundwater in underground aquifers. The ...
s to consumers to satisfy residential, commercial, industrial and fire fighting requirements.


Definitions

Water distribution network is the term for the portion of a water distribution system up to the service points of bulk water consumers or demand nodes where many consumers are lumped together. The
World Health Organization The World Health Organization (WHO) is a specialized agency of the United Nations responsible for international public health. The WHO Constitution states its main objective as "the attainment by all peoples of the highest possible level of ...
(WHO) uses the term water transmission system for a network of pipes, generally in a tree-like structure, that is used to convey water from water treatment plants to service reservoirs, and uses the term water distribution system for a network of pipes that generally has a loop structure to supply water from the service reservoirs and balancing reservoirs to consumers.


Components

A water distribution system consists of pipelines, storage facilities, pumps, and other accessories. Pipelines laid within public
right of way Right of way is the legal right, established by grant from a landowner or long usage (i.e. by prescription), to pass along a specific route through property belonging to another. A similar ''right of access'' also exists on land held by a gov ...
called water mains are used to transport water within a distribution system. Large diameter water mains called primary feeders are used to connect between water treatment plants and service areas. Secondary feeders are connected between primary feeders and distributors. Distributors are water mains that are located near the water users, which also supply water to individual
fire hydrant A fire hydrant, waterplug, or firecock (archaic) is a connection point by which firefighters can tap into a water supply. It is a component of active fire protection. Underground fire hydrants have been used in Europe and Asia since at least t ...
s. A service line is a small diameter pipe used to connect from a water main through a small tap to a
water meter Water metering is the practice of measuring water use. Water meters measure the volume of water used by residential and commercial building units that are supplied with water by a public water supply system. They are also used to determine flow ...
at user's location. There is a service valve (also known as curb stop) on the service line located near street
curb A curb (North American English), or kerb (Commonwealth English except Canada; see spelling differences), is the edge where a raised sidewalk or road median/central reservation meets a street or other roadway. History Although curbs have ...
to shut off water to the user's location. Storage facilities, or distribution reservoirs, provide clean drinking water storage (after required water treatment process) to ensure the system has enough water to service in response to fluctuating demands ( service reservoirs), or to equalize the operating pressure ( balancing reservoirs). They can also be temporarily used to serve fire fighting demands during a power outage. The following are types of distribution reservoirs: * Underground storage reservoir or covered finished water reservoir: An underground storage facility or large ground-excavated reservoir that is fully covered. The walls and the bottom of these reservoirs may be lined with impermeable materials to prevent ground water intrusion. * Uncovered finished water reservoir: A large ground-excavated reservoir that has adequate measures or lining to prevent surface water runoff and ground water intrusion but does not have a top cover. This type of reservoir is less desirable as the water will not be further treated before distribution and is susceptible to contaminants such as bird waste, animal and human activities,
algal bloom An algal bloom or algae bloom is a rapid increase or accumulation in the population of algae in freshwater or marine water systems. It is often recognized by the discoloration in the water from the algae's pigments. The term ''algae'' encompass ...
, and airborne deposition. * Surface reservoir (also known as ground storage tank and ground storage reservoir): A storage facility built on the ground with the wall lined with concrete,
shotcrete Shotcrete, gunite (), or sprayed concrete is concrete or mortar conveyed through a hose and pneumatically projected at high velocity onto a surface, as a construction technique, first used in 1907 invented by Carl Akeley. It is typically ...
, asphalt, or membrane. A surface reservoir is usually covered to prevent contamination. They are typically located in high elevation areas that have enough hydraulic head for distribution. When a surface reservoir at ground level cannot provide a sufficient hydraulic head to the distribution system, booster pumps will be required. *
Water tower A water tower is an elevated structure supporting a water tank constructed at a height sufficient to pressurize a distribution system for potable water, and to provide emergency storage for fire protection. Water towers often operate in conju ...
(also known as elevated surface reservoir): An elevated water tank. A few common types are spheroid elevated storage tank, a steel spheroid tank on top of a small-diameter steel column; composite elevated storage tank, a steel tank on a large-diameter concrete column; and hydropillar elevated storage tanks, a steel tank on a large-diameter steel column. The space within the large column below the water tank can be used for other purposes such as multi-story office space and storage space. A main concern for using water towers in the water distribution system is the aesthetic of the area. * Standpipe: A water tank that is a combination of ground storage tank and water tower. It is slightly different from an elevated water tower in that the standpipe allows water storage from the ground level to the top of the tank. The bottom storage area is called supporting storage, and the upper part which would be at the similar height of an elevated water tower is called useful storage. * Sump: This is a contingency water storage facility that is not used to distribute water directly. It is typically built underground in a circular shape with a dome top above ground. The water from a sump will be pumped to a service reservoir when it is needed. Storage facilities are typically located at the center of the service locations. Being at the central location reduces the length of the water mains to the services locations. This reduces the friction loss when water is transported over a water main. File:Fort Canning Service Reservoir.JPG, Underground storage reservoir File:New Street Reservoir, Woodland Park, New Jersey.jpg, Uncovered finished water reservoir File:Covered Reservoir in Bullaburra NSW Australia.jpg, Ground storage tank File:Oxbow Water Tower.jpg, Spheroid elevated storage tank File:WisconsinRapidsWisconsinWaterTower.jpg, Composite elevated storage tank File:Fayetteville water tower.jpg, Hydropillar elevated storage tank File:Neillsville Standpipe.jpg, Standpipe


Topologies

In general, a water distribution system can be classified as having a grid, ring, radial or dead end layout. A grid system follows the general layout of the road grid with water mains and branches connected in rectangles. With this topology, water can be supplied from several directions allowing good water circulation and redundancy if a section of the network has broken down. Drawbacks of this topology include difficulty sizing the system. A ring system has a water main for each road, and there is a sub-main branched off the main to provide circulation to customers. This topology has some of the advantages of a grid system, but it is easier to determine sizing. A radial system delivers water into multiple zones. At the center of each zone, water is delivered radially to the customers. A dead end system has water mains along roads without a rectangular pattern. It is used for communities whose road networks are not regular. As there are no cross-connections between the mains, water can have less circulation and therefore stagnation may be a problem.


Integrity of the systems

The integrity of the systems are broken down into physical, hydraulic, and water quality. The physical integrity includes concerns on the ability of the barriers to prevents contaminations from the external sources to get into water distribution systems. The deterioration can be caused by physical or chemical factors. The hydraulic integrity is an ability to maintain adequate water pressure inside the pipes throughout distribution systems. It also includes the circulation and length of time that the water travels within a distribution system which has impacts on the effectiveness of the disinfectants. The water quality integrity is a control of degradations as the water travels through distribution systems. The impacts of water quality can be caused by physical or hydraulic integrity factors. The water quality degradations can also take place within the distribution systems such as microorganism growth,
nitrification ''Nitrification'' is the biological oxidation of ammonia to nitrite followed by the oxidation of the nitrite to nitrate occurring through separate organisms or direct ammonia oxidation to nitrate in comammox bacteria. The transformation of am ...
, and internal corrosion of the pipes.


Network analysis and optimization

Analyses are done to assist in design, operation, maintenance and optimization of water distribution systems. There are two main types of analyses: hydraulic, and water quality behavior as it flows through a water distribution system. Optimizing the design of water distribution networks is a complex task. However, a large number of methods have already been proposed, mainly based on metaheuristics. Employing mathematical optimization techniques can lead to substantial construction savings in these kinds of infrastructures.


Hazards

Hazards in water distribution systems can be in the forms of microbial, chemical and physical. Most microorganisms are harmless within water distribution systems. However, when infectious microorganisms enter the systems, they form
biofilm A biofilm comprises any syntrophic consortium of microorganisms in which cells stick to each other and often also to a surface. These adherent cells become embedded within a slimy extracellular matrix that is composed of extracellular ...
s and create microbial hazards to the users. Biofilms are usually formed near the end of the distribution where the water circulation is low. This supports their growth and makes disinfection agents less effective. Common microbial hazards in distribution systems come from contamination of human faecal pathogens and parasites which enter the systems through cross-connections, breaks, water main works, and open storage tanks. Chemical hazards are those of
disinfection by-product Disinfection by-products (DBPs) result from chemical reactions between organic and inorganic matter in water with chemical treatment agents during the water disinfection process. Chlorination disinfection byproducts Chlorinated disinfection agen ...
s, leaching of piping materials and fittings, and water treatment chemicals. Physical hazards include
turbidity Turbidity is the cloudiness or haziness of a fluid caused by large numbers of individual particles that are generally invisible to the naked eye, similar to smoke in air. The measurement of turbidity is a key test of water quality. Fluids ...
of water, odors, colors, scales which are buildups of materials inside the pipes from corrosions, and sediment resuspension. There are several bodies around the world that create standards to limit hazards in the distribution systems: NSF International in North America;
European Committee for Standardization The European Committee for Standardization (CEN, french: Comité Européen de Normalisation) is a public standards organization whose mission is to foster the economy of the European Single Market and the wider European continent in global t ...
,
British Standards Institution The British Standards Institution (BSI) is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to busines ...
and
Umweltbundesamt The Umweltbundesamt (; UBA, ) is the ''German Environment Agency''. Together with the Bundesamt für Naturschutz, the Bundesamt für kerntechnische Entsorgungssicherheit and the Bundesamt für Strahlenschutz, it operates under the jurisdiction ...
in Europe;
Japanese Standards Association is the Japanese industrial standard development organization. JSA promotes standardization and management system in Japan through the following activities: * Development of national standards ( JIS) * Support of international standardization act ...
in Asia;
Standards Australia Standards Australia is a standards organisation established in 1922 and is recognised through a Memorandum of Understanding (MoU) with the Australian government as the primary non-government standards development body in Australia. It is a com ...
in Australia; and Brazilian National Standards Organization in Brazil.


Lead service lines

Lead contamination in drinking water can be from leaching of lead that was used in old water mains, service lines, pipe joints, plumbing fittings and fixtures. According to WHO, the most significant contributor of lead in water in many countries is the lead service line.


Maintenance


Internal corrosion control

Water quality deteriorate due to corrosion of metal pipe surfaces and connections in distribution systems. Pipe corrosion shows in water as color, taste and odor, any of which may cause health concerns. Health issues relate to releases of trace metals such as lead, copper or cadmium into the water. Lead exposure can cause delays in physical and mental development in children. Long term exposure to copper may cause liver and kidney damage. High or long term exposure of cadmium may cause damage to various organs. Corrosion of iron pipes causes rusty or red water. Corrosion of zinc and iron pipes can cause metallic taste. Various techniques can be used to control internal corrosion, for example, pH level adjustment, adjustment of
carbonate A carbonate is a salt of carbonic acid (H2CO3), characterized by the presence of the carbonate ion, a polyatomic ion with the formula . The word ''carbonate'' may also refer to a carbonate ester, an organic compound containing the carbonate ...
and
calcium Calcium is a chemical element with the symbol Ca and atomic number 20. As an alkaline earth metal, calcium is a reactive metal that forms a dark oxide-nitride layer when exposed to air. Its physical and chemical properties are most similar t ...
to create calcium carbonate as pipe surface coating, and applying a
corrosion inhibitor In chemistry, a corrosion inhibitor or anti-corrosive is a chemical compound that, when added to a liquid or gas, decreases the corrosion rate of a material, typically a metal or an alloy, that comes into contact with the fluid. The effectiveness ...
. For example,
phosphate In chemistry, a phosphate is an anion, salt, functional group or ester derived from a phosphoric acid. It most commonly means orthophosphate, a derivative of orthophosphoric acid . The phosphate or orthophosphate ion is derived from phosph ...
products that form films over pipe surfaces is a type of corrosion inhibitor. This reduces the chance of
leaching Leaching is the loss or extraction of certain materials from a carrier into a liquid (usually, but not always a solvent). and may refer to: * Leaching (agriculture), the loss of water-soluble plant nutrients from the soil; or applying a small amou ...
of trace metals from the pipe materials into the water.


Hydrant flushing

Hydrant flushing is the scheduled release of water from
fire hydrant A fire hydrant, waterplug, or firecock (archaic) is a connection point by which firefighters can tap into a water supply. It is a component of active fire protection. Underground fire hydrants have been used in Europe and Asia since at least t ...
s or special
flushing hydrant A flushing hydrant is a hydrant that is used for flushing a water line of silt, rust, debris, or stagnant water Water stagnation occurs when water stops flowing. Stagnant water can be a major environmental hazard. Dangers Malaria and deng ...
s to purge iron and other mineral deposits from a water main. Another benefit of using fire hydrants for water main flushing is to test whether water is supplied to fire hydrants at adequate pressure for fire fighting. During hydrant flushing, consumers may notice rust color in their water as iron and mineral deposits are stirred up in the process.


Water main renewals

After water mains are in service for a long time, there will be deterioration in structural, water quality, and hydraulic performance. Structural deterioration may be caused by many factors. Metal-based pipes develop internal and external corrosion, causing the pipe walls to thin or degrade. They can eventually leak or burst. Cement-based pipes are subject to cement matrix and reinforced steel deterioration. All pipes are subject to joint failures. Water quality deterioration includes scaling, sedimentation, and biofilm formation. Scaling is the formation of hard deposits on the interior wall of pipes. This can be a by-product of pipe corrosion combined with calcium in the water, which is called tuberculation. Sedimentation is when solids settle within the pipes, usually at recesses between scaling build-ups. When there is a change in the velocity of water flow (such as sudden use of a fire hydrant), the settled solids will be stirred up, causing water to be discolored. Biofilms can develop in highly scaled and thus rough-surfaced pipes where bacteria are allowed to grow, as the higher the roughness of the interior wall, the harder it is for disinfectant to kill the bacteria on the surface of the pipe wall. Hydraulic deterioration that affects pressures and flows can be a result of other deterioration that obstructs the water flow. When it is time for water main renewal, there are many considerations in choosing the method of renewal. This can be open-trench replacement or one of the pipeline rehabilitation methods. A few pipeline rehabilitation methods are pipe bursting, sliplining, and pipe lining. File:PWD Great Lakes water main installation (14058449987).jpg, Open-trench water main replacement File:Temporary Bypass Piping - feed hydrant.jpg, Feed hydrant supplies water to a temporary bypass piping File:Temporary Bypass Piping - service connection.jpg, Service connection of a temporary bypass piping File:Temporary Bypass Piping - temporary fire hydrant.jpg, Temporary fire hydrant When an in-situ rehabilitation method is used, one benefit is the lower cost, as there is no need to excavate along the entire water main pipeline. Only small pits are excavated to access the existing water main. The unavailability of the water main during the rehabilitation, however, requires building a temporary water bypass system to serve as the water main in the affected area. A temporary water bypass system (known as temporary bypass piping) should be carefully designed to ensure an adequate water supply to the customers in the project area. Water is taken from a feed hydrant into a temporary pipe. When the pipe crosses a driveway or a road, a cover or a cold patch should be put in place to allow cars to cross the temporary pipe. Temporary service connections to homes can be made to the temporary pipe. Among many ways to make a temporary connection, a common one is to connect the temporary service connection to a garden hose. The temporary pipe should also add temporary fire hydrants for fire protection. As water main work can disturb lead service lines, which can result in elevated lead levels in drinking water, it is recommended that when a water utility plans a water main renewal project, it should work with property owners to replace lead service lines as part of the project.


See also

*
Water supply network A water supply network or water supply system is a system of engineered hydrologic and hydraulic components that provide water supply. A water supply system typically includes the following: # A drainage basin (see water purification – source ...


References

{{reflist Supply network Environmental engineering Hydraulics Supply network