HOME

TheInfoList



OR:

Time of flight (ToF) is the measurement of the time taken by an object, particle or wave (be it acoustic, electromagnetic, etc.) to travel a distance through a medium. This information can then be used to measure velocity or path length, or as a way to learn about the particle or medium's properties (such as composition or flow rate). The traveling object may be detected directly (direct time of flight, dToF, e.g., via an ion detector in mass spectrometry) or indirectly (indirect time of flight, iToF, e.g., by light scattered from an object in laser doppler
velocimetry Velocimetry is the measurement of the velocity of fluids. This is a task often taken for granted, and involves far more complex processes than one might expect. It is often used to solve fluid dynamics problems, study fluid networks, in industria ...
).


Overview

In
electronics The field of electronics is a branch of physics and electrical engineering that deals with the emission, behaviour and effects of electrons using electronic devices. Electronics uses active devices to control electron flow by amplification ...
, one of the earliest devices using the principle are ultrasonic distance-measuring devices, which emit an ultrasonic pulse and are able to measure the distance to a solid object based on the time taken for the wave to bounce back to the emitter. The ToF method is also used to estimate the electron mobility. Originally, it was designed for measurement of low-conductive thin films, later adjusted for common semiconductors. This experimental technique is used for metal-dielectric-metal structures as well as organic field-effect transistors. The excess charges are generated by application of the laser or voltage pulse. For Magnetic Resonance Angiography (MRA), ToF is a major underlying method. In this method, blood entering the imaged area is not yet saturated, giving it a much higher signal when using short echo time and flow compensation. It can be used in the detection of
aneurysm An aneurysm is an outward bulging, likened to a bubble or balloon, caused by a localized, abnormal, weak spot on a blood vessel wall. Aneurysms may be a result of a hereditary condition or an acquired disease. Aneurysms can also be a nidus ( ...
, stenosis or dissection. In time-of-flight mass spectrometry, ions are accelerated by an electrical field to the same
kinetic energy In physics, the kinetic energy of an object is the energy that it possesses due to its motion. It is defined as the work needed to accelerate a body of a given mass from rest to its stated velocity. Having gained this energy during its acc ...
with the velocity of the ion depending on the mass-to-charge ratio. Thus the time-of-flight is used to measure velocity, from which the mass-to-charge ratio can be determined. The time-of-flight of electrons is used to measure their kinetic energy. In
near-infrared spectroscopy Near-infrared spectroscopy (NIRS) is a spectroscopic method that uses the near-infrared region of the electromagnetic spectrum (from 780 nm to 2500 nm). Typical applications include medical and physiological diagnostics and research inc ...
, the ToF method is used to measure the media-dependent optical pathlength over a range of optical wavelengths, from which composition and properties of the media can be analyzed. In ultrasonic flow meter measurement, ToF is used to measure speed of signal propagation upstream and downstream of flow of a media, in order to estimate total flow velocity. This measurement is made in a collinear direction with the flow. In planar Doppler velocimetry (optical flow meter measurement), ToF measurements are made perpendicular to the flow by timing when individual particles cross two or more locations along the flow (collinear measurements would require generally high flow velocities and extremely narrow-band optical filters). In optical interferometry, the pathlength difference between sample and reference arms can be measured by ToF methods, such as frequency modulation followed by phase shift measurement or cross correlation of signals. Such methods are used in laser radar and laser tracker systems for medium-long range distance measurement. In neutron time-of-flight scattering, a pulsed monochromatic neutron beam is scattered by a sample. The energy spectrum of the scattered neutrons is measured via time of flight. In kinematics, ToF is the duration in which a projectile is traveling through the air. Given the initial velocity u of a particle launched from the ground, the downward (i.e. gravitational) acceleration a, and the projectile's angle of projection ''θ'' (measured relative to the horizontal), then a simple rearrangement of the SUVAT equation :s = vt - \begin \frac \end at^2 results in this equation :t=\frac for the time of flight of a projectile.


In mass spectrometry

The time-of-flight principle can be applied for mass spectrometry.
Ion An ion () is an atom or molecule with a net electrical charge. The charge of an electron is considered to be negative by convention and this charge is equal and opposite to the charge of a proton, which is considered to be positive by conve ...
s are accelerated by an electric field of known strength. This acceleration results in an ion having the same
kinetic energy In physics, the kinetic energy of an object is the energy that it possesses due to its motion. It is defined as the work needed to accelerate a body of a given mass from rest to its stated velocity. Having gained this energy during its acc ...
as any other ion that has the same charge. The velocity of the ion depends on the mass-to-charge ratio. The time that it subsequently takes for the particle to reach a detector at a known distance is measured. This time will depend on the mass-to-charge ratio of the particle (heavier particles reach lower speeds). From this time and the known experimental parameters one can find the mass-to-charge ratio of the ion. The elapsed time from the instant a particle leaves a source to the instant it reaches a detector.


In flow meters

An ultrasonic flow meter measures the velocity of a liquid or gas through a pipe using acoustic sensors. This has some advantages over other measurement techniques. The results are slightly affected by temperature, density or conductivity. Maintenance is inexpensive because there are no
moving parts Machines include both fixed and moving parts. The moving parts have controlled and constrained motions. Moving parts are machine components excluding any moving fluids, such as fuel, coolant or hydraulic fluid. Moving parts also do not include ...
. Ultrasonic flow meters come in three different types: transmission (contrapropagating transit time) flowmeters, reflection (Doppler) flowmeters, and open-channel flowmeters. Transit time flowmeters work by measuring the time difference between an ultrasonic pulse sent in the flow direction and an ultrasound pulse sent opposite the flow direction. Doppler flowmeters measure the doppler shift resulting in reflecting an ultrasonic beam off either small particles in the fluid, air bubbles in the fluid, or the flowing fluid's turbulence. Open channel flow meters measure upstream levels in front of
flume A flume is a human-made channel for water, in the form of an open declined gravity chute whose walls are raised above the surrounding terrain, in contrast to a trench or ditch. Flumes are not to be confused with aqueducts, which are built to t ...
s or
weir A weir or low head dam is a barrier across the width of a river that alters the flow characteristics of water and usually results in a change in the height of the river level. Weirs are also used to control the flow of water for outlets of l ...
s. Optical time-of-flight sensors consist of two light beams projected into the fluid whose detection is either interrupted or instigated by the passage of small particles (which are assumed to be following the flow). This is not dissimilar from the optical beams used as safety devices in motorized garage doors or as triggers in alarm systems. The speed of the particles is calculated by knowing the spacing between the two beams. If there is only one detector, then the time difference can be measured via autocorrelation. If there are two detectors, one for each beam, then direction can also be known. Since the location of the beams is relatively easy to determine, the precision of the measurement depends primarily on how small the setup can be made. If the beams are too far apart, the flow could change substantially between them, thus the measurement becomes an average over that space. Moreover, multiple particles could reside between them at any given time, and this would corrupt the signal since the particles are indistinguishable. For such a sensor to provide valid data, it must be small relative to the scale of the flow and the seeding density. MOEMS approaches yield extremely small packages, making such sensors applicable in a variety of situations.


In physics

Usually the time-of-flight tube used in mass spectrometry is praised for simplicity, but for precision measurements of charged low energy particles the electric and the magnetic field in the tube has to be controlled within 10 mV and 1 nT respectively. The
work function In solid-state physics, the work function (sometimes spelt workfunction) is the minimum thermodynamic work (i.e., energy) needed to remove an electron from a solid to a point in the vacuum immediately outside the solid surface. Here "immediately" ...
homogeneity of the tube can be controlled by a Kelvin probe. The magnetic field can be measured by a fluxgate compass. High frequencies are passively shielded and damped by radar absorbent material. To generate arbitrary low frequencies field the screen is parted into plates (overlapping and connected by capacitors) with bias voltage on each plate and a bias current on coil behind plate whose flux is closed by an outer core. In this way the tube can be configured to act as a weak achromatic quadrupole lens with an aperture with a grid and a delay line detector in the diffraction plane to do angle resolved measurements. Changing the field the angle of the field of view can be changed and a deflecting bias can be superimposed to scan through all angles. When no delay line detector is used focusing the ions onto a detector can be accomplished through the use of two or three
einzel lens An einzel lens (from german: Einzellinse – single lens), or unipotential lens, is a charged particle electrostatic lens that focuses without changing the energy of the beam. It consists of three or more sets of cylindrical or rectangular apertur ...
es placed in the vacuum tube located between the ion source and the detector. The sample should be immersed into the tube with holes and apertures for and against stray light to do magnetic experiments and to control the electrons from their start.


Camera


Detector


See also

*
Propagation delay Propagation delay is the time duration taken for a signal to reach its destination. It can relate to networking, electronics or physics. ''Hold time'' is the minimum interval required for the logic level to remain on the input after triggering ed ...
*
Round-trip time In telecommunications, round-trip delay (RTD) or round-trip time (RTT) is the amount of time it takes for a signal to be sent ''plus'' the amount of time it takes for acknowledgement of that signal having been received. This time delay includes pr ...
*
Time of arrival Time of arrival (TOA or ToA) is the absolute time instant when a radio signal emanating from a transmitter reaches a remote receiver. The time span elapsed since the time of transmission (TOT or ToT) is the ''time of flight'' (TOF or ToF). Time diff ...
*
Time of transmission Time of arrival (TOA or ToA) is the absolute time instant when a radio signal emanating from a transmitter reaches a remote receiver. The time span elapsed since the time of transmission (TOT or ToT) is the ''time of flight'' (TOF or ToF). Time diff ...


References

{{DEFAULTSORT:Time-Of-Flight Mass spectrometry Spectroscopy Time measurement systems