HOME

TheInfoList



OR:

Sound intensity, also known as acoustic intensity, is defined as the power carried by sound waves per unit area in a direction perpendicular to that area. The
SI unit The International System of Units, known by the international abbreviation SI in all languages and sometimes pleonastically as the SI system, is the modern form of the metric system and the world's most widely used system of measurement. ...
of intensity, which includes sound intensity, is the
watt The watt (symbol: W) is the unit of power or radiant flux in the International System of Units (SI), equal to 1 joule per second or 1 kg⋅m2⋅s−3. It is used to quantify the rate of energy transfer. The watt is named after James ...
per square meter (W/m2). One application is the noise measurement of sound intensity in the air at a listener's location as a sound energy quantity. Sound intensity is not the same physical quantity as
sound pressure Sound pressure or acoustic pressure is the local pressure deviation from the ambient (average or equilibrium) atmospheric pressure, caused by a sound wave. In air, sound pressure can be measured using a microphone, and in water with a hydrop ...
. Human hearing is sensitive to sound pressure which is related to sound intensity. In consumer audio electronics, the level differences are called "intensity" differences, but sound intensity is a specifically defined quantity and cannot be sensed by a simple microphone.
Sound intensity level Sound intensity, also known as acoustic intensity, is defined as the power carried by sound waves per unit area in a direction perpendicular to that area. The SI unit of intensity, which includes sound intensity, is the watt per square meter (W/m2 ...
is a logarithmic expression of sound intensity relative to a reference intensity.


Mathematical definition

Sound intensity, denoted I, is defined by \mathbf I = p \mathbf v where * ''p'' is the
sound pressure Sound pressure or acoustic pressure is the local pressure deviation from the ambient (average or equilibrium) atmospheric pressure, caused by a sound wave. In air, sound pressure can be measured using a microphone, and in water with a hydrop ...
; * v is the
particle velocity Particle velocity is the velocity of a particle (real or imagined) in a medium as it transmits a wave. The SI unit of particle velocity is the metre per second (m/s). In many cases this is a longitudinal wave of pressure as with sound, but it can ...
. Both I and v are vectors, which means that both have a ''direction'' as well as a magnitude. The direction of sound intensity is the average direction in which energy is flowing. The average sound intensity during time ''T'' is given by \langle \mathbf I\rangle = \frac \int_0^T p(t) \mathbf v(t) \,\mathrmt. For a plane wave , \Iota = 2\pi^2\nu^2 \delta^2 \rho c Where, * \nu is frequency of sound, * \delta is the amplitude of the sound wave
particle displacement Particle displacement or displacement amplitude is a measurement of distance of the movement of a sound particle from its equilibrium position in a medium as it transmits a sound wave. The SI unit of particle displacement is the metre (m). In m ...
, * \rho is density of medium in which sound is traveling, and * c is speed of sound.


Inverse-square law

For a ''spherical'' sound wave, the intensity in the radial direction as a function of distance ''r'' from the centre of the sphere is given by I(r) = \frac = \frac, where * ''P'' is the
sound power Sound power or acoustic power is the rate at which sound energy is emitted, reflected, transmitted or received, per unit time. It is defined as "through a surface, the product of the sound pressure, and the component of the particle velocity, at ...
; * ''A''(''r'') is the surface area of a sphere of radius ''r''. Thus sound intensity decreases as 1/''r''2 from the centre of the sphere: I(r) \propto \frac. This relationship is an ''inverse-square law''.


Sound intensity level

Sound intensity level (SIL) or acoustic intensity level is the
level Level or levels may refer to: Engineering *Level (instrument), a device used to measure true horizontal or relative heights *Spirit level, an instrument designed to indicate whether a surface is horizontal or vertical * Canal pound or level *Reg ...
(a logarithmic quantity) of the intensity of a sound relative to a reference value. It is denoted ''L''''I'', expressed in
neper The neper (symbol: Np) is a logarithmic unit for ratios of measurements of physical field and power quantities, such as gain and loss of electronic signals. The unit's name is derived from the name of John Napier, the inventor of logarithms. A ...
s, bels, or
decibel The decibel (symbol: dB) is a relative unit of measurement equal to one tenth of a bel (B). It expresses the ratio of two values of a power or root-power quantity on a logarithmic scale. Two signals whose levels differ by one decibel have a ...
s, and defined by"Letter symbols to be used in electrical technology – Part 3: Logarithmic and related quantities, and their units"
''IEC 60027-3 Ed. 3.0'', International Electrotechnical Commission, 19 July 2002.
L_I = \frac \ln\left(\frac\right) \mathrm = \log_\left(\frac\right)\mathrm = 10 \log_\left(\frac\right) \mathrm, where * ''I'' is the sound intensity; * ''I''0 is the ''reference sound intensity''; ** is the
neper The neper (symbol: Np) is a logarithmic unit for ratios of measurements of physical field and power quantities, such as gain and loss of electronic signals. The unit's name is derived from the name of John Napier, the inventor of logarithms. A ...
; ** is the
bel BEL can be an abbreviation for: * The ISO 3166-1 alpha-3 country code for Belgium * ''BEL'' or bell character in the C0 control code set * Belarusian language, in the ISO 639-2 and SIL country code lists * Bharat Electronics Limited, an Indian sta ...
; ** is the
decibel The decibel (symbol: dB) is a relative unit of measurement equal to one tenth of a bel (B). It expresses the ratio of two values of a power or root-power quantity on a logarithmic scale. Two signals whose levels differ by one decibel have a ...
. The commonly used reference sound intensity in air is I_0 = 1~\mathrm. being approximately the lowest sound intensity hearable by an undamaged human ear under room conditions. The proper notations for sound intensity level using this reference are or , but the notations , , dBSIL, or dBSIL are very common, even if they are not accepted by the SI.Thompson, A. and Taylor, B. N. sec 8.7, "Logarithmic quantities and units: level, neper, bel", ''Guide for the Use of the International System of Units (SI) 2008 Edition'', NIST Special Publication 811, 2nd printing (November 2008), SP81
PDF
/ref> The reference sound intensity ''I''0 is defined such that a progressive plane wave has the same value of sound intensity level (SIL) and
sound pressure level Sound pressure or acoustic pressure is the local pressure deviation from the ambient (average or equilibrium) atmospheric pressure, caused by a sound wave. In air, sound pressure can be measured using a microphone, and in water with a hydropho ...
(SPL), since I \propto p^2. The equality of SIL and SPL requires that \frac = \frac, where is the reference sound pressure. For a ''progressive'' spherical wave, \frac = z_0, where ''z''0 is the characteristic specific acoustic impedance. Thus, I_0 = \frac = \frac = \frac. In air at ambient temperature, , hence the reference value . In an
anechoic chamber An anechoic chamber (''an-echoic'' meaning "non-reflective") is a room designed to stop reflections of either sound or electromagnetic waves. They are also often isolated from energy entering from their surroundings. This combination means t ...
which approximates a free field (no reflection) with a single source, measurements in the far field in SPL can be considered to be equal to measurements in SIL. This fact is exploited to measure sound power in anechoic conditions.


Measurement

Sound intensity is defined as the time averaged product of sound pressure and acoustic particle velocity. Both quantities can be directly measured by using a sound intensity ''p-u'' probe comprising a microphone and a particle velocity sensor, or estimated indirectly by using a ''p-p'' probe that approximates the particle velocity by integrating the pressure gradient between two closely spaced microphones. Pressure-based measurement methods are widely used in anechoic conditions for noise quantification purposes. The bias error introduced by a ''p-p'' probe can be approximated by \widehat^_n \simeq I_n - \frac=I_n \left( 1 - \frac \frac\right) , where I_nis the “true” intensity (unaffected by calibration errors), \hat^_n is the biased estimate obtained using a ''p-p'' probe, p_is the root-mean-squared value of the sound pressure, k is the wave number, \rho is the density of air, c is the speed of sound and \Delta r is the spacing between the two microphones. This expression shows that phase calibration errors are inversely proportional to frequency and microphone spacing and directly proportional to the ratio of the mean square sound pressure to the sound intensity. If the pressure-to-intensity ratio is large then even a small phase mismatch will lead to significant bias errors. In practice, sound intensity measurements cannot be performed accurately when the pressure-intensity index is high, which limits the use of ''p-p'' intensity probes in environments with high levels of background noise or reflections. On the other hand, the bias error introduced by a ''p-u'' probe can be approximated by \hat^_n = \frac \operatorname\left\ = \frac \operatorname\left\ \simeq I_n + \varphi_ J_n \, , where \hat^_n is the biased estimate obtained using a ''p-u'' probe, P and V_n are the Fourier transform of sound pressure and particle velocity, J_n is the reactive intensity and \varphi_ is the ''p-u'' phase mismatch introduced by calibration errors. Therefore, the phase calibration is critical when measurements are carried out under near field conditions, but not so relevant if the measurements are performed out in the far field. The “reactivity” (the ratio of the reactive to the active intensity) indicates whether this source of error is of concern or not. Compared to pressure-based probes, ''p-u'' intensity probes are unaffected by the pressure-to-intensity index, enabling the estimation of propagating acoustic energy in unfavorable testing environments provided that the distance to the sound source is sufficient.


References


External links


How Many Decibels Is Twice as Loud? Sound Level Change and the Respective Factor of Sound Pressure or Sound Intensity
* ttp://www.sengpielaudio.com/calculator-ak-ohm.htm Ohm's Law as Acoustic Equivalent. Calculationsbr>Relationships of Acoustic Quantities Associated with a Plane Progressive Acoustic Sound Wave
* ttp://www.acoustical-consultants.com/noise-vibration-acoustical-related-resources/sound-intensity-noise-measurements/ What Is Sound Intensity Measurement and Analysis? {{Authority control Acoustics Sound Sound measurements Physical quantities