Seismic codes or earthquake codes are
building codes A building code (also building control or building regulations) is a set of rules that specify the standards for constructed objects such as buildings and non-building structures. Buildings must conform to the code to obtain planning permissio ...
designed to protect property and life in buildings in case of earthquakes. The need for such codes is reflected in the saying, "Earthquakes don't kill people—buildings do." Or in expanded version, “Earthquakes do not injure or kill people. Poorly built manmade structures injure and kill people.” Seismic codes were created and developed as a response to major earthquakes which have caused devastation in highly populated regions. Often these are revised based on knowledge gained from recent earthquakes and research findings, and as such they are constantly evolving. There are many seismic codes used worldwide. Most codes at their root share common fundamental approaches regarding how to design buildings for earthquake effects, but will differ in their technical requirements and will have language addressing local geologic conditions, common construction types, historic issues, etc.


Origin

The
1755 Lisbon earthquake The 1755 Lisbon earthquake, also known as the Great Lisbon earthquake, impacted Portugal, the Iberian Peninsula, and Northwest Africa on the morning of Saturday, 1 November, Feast of All Saints, at around 09:40 local time. In combination with ...
(Portugal) resulted in prescriptive rules for building certain kinds of buildings common in the area. Following the 1908 Messina earthquake (Italy), the Royal Government of Italy established Geological Committee and Engineering Committee in early 1909 to study the disaster and recommend earthquake disaster mitigation measures. The Engineering Committee, after studying the lateral load resistance of buildings which survived the earthquake motion, recommended that the seismic ratio (seismic acceleration divided by the gravity acceleration) equal to 1/12 for the first floor and 1/8 for the floors above should be used in seismic design of buildings. The Committee proposed equivalent vertical forces much larger than the horizontal forces because vertical motion acted as impacts. This is believed to be the first known quantitative recommendation of design seismic forces in the history of seismic codes. The recommendation was adopted in Royal Decree No. 573 of April 29, 1915. The height of the buildings was limited to two stories, and the first story should be designed for a horizontal force equal to 1/8 the second floor weight and the second story for 1/6 of the roof weight. The
1923 Great Kantō earthquake The struck the Kantō Plain on the main Japanese island of Honshū at 11:58:44 JST (02:58:44 UTC) on Saturday, September 1, 1923. Varied accounts indicate the duration of the earthquake was between four and ten minutes. Extensive firestorms an ...
(Japan) and earlier events inspired Japanese engineer Toshikata Sano to develop a lateral force procedure that was officially implemented in the 1924 Japanese Urban Building Law, which directed engineers to design buildings for horizontal forces of about 10% of the weight of the building. In 1925, the city of Santa Barbara, California, added a building code requirement that structures be designed to withstand horizontal forces, but was nonspecific regarding design loads or procedure. This is considered to be the first explicit policy and legal consideration of the seismic safety of structures in the U.S. The city of Palo Alto, California, led by professors at Stanford, also added similar language to its building code in 1926. In January 1928, the first edition of the Uniform Building Code (UBC) was published, and included an appendix with non-mandatory matter with §2311 recommending a minimum lateral design force for earthquake resistance of V = 0.075W for buildings on foundations with allowable bearing pressures of 4,000 psf or more, and 0.10 W for all other buildings including those on pile foundations. Building weight (seismic mass) was defined as: W = Dead load + Live load. These provisions were inspired by Japan's newly developed seismic code. The non-mandatory lateral design provisions are not known to have been explicitly adopted by any jurisdiction at the time, but may have been used voluntarily for the design of some buildings. In response to the
1933 Long Beach earthquake The 1933 Long Beach earthquake took place on March 10 at south of downtown Los Angeles. The epicenter was offshore, southeast of Long Beach, California, on the Newport–Inglewood Fault. The earthquake had a magnitude estimated at 6.4 , and a ...
(California), the city of Los Angeles adopted the first earthquake design provisions enforced in the U.S., enacted by City Council under Ordinance No. 72,968 published September 6, 1933. The requirements included a design lateral base shear V = 0.08 W for regular use buildings, 0.10 W for school buildings and 0.04 W for the portion of a building above a flexible story. Building weight (seismic mass) was defined as W = Dead load + 0.5 Live load (except 1.0 Live for warehouses). Building frames were required to be designed to withstand at least 0.25V independent of any walls. Immediately after the
1933 Long Beach earthquake The 1933 Long Beach earthquake took place on March 10 at south of downtown Los Angeles. The epicenter was offshore, southeast of Long Beach, California, on the Newport–Inglewood Fault. The earthquake had a magnitude estimated at 6.4 , and a ...
, careful analysis of structural failures in that quake by architect Louis John Gill formed the basis for much of the California seismic legislation (
Field Act The Field Act was one of the first pieces of legislation that mandated earthquake-resistant construction (specifically for schools in California) in the United States. The Field Act had its genesis in the 6.4 magnitude 1933 Long Beach earthquake ...
for schools and Riley Act for all buildings).Rev. C. Douglas Kroll, ''Journal of San Diego History'', "LOUIS JOHN GILL: Famous but Forgotten Architect", San Diego Historical Society Quarterly, Summer 1984, Volume 30, Number 3
/ref> The 1933 Riley Act required all California local governments to have a building department and inspect new construction, mandating that all structures in the state be designed to withstand a horizontal acceleration of 0.02 times the acceleration due to gravity.


Around the world


Mexico

The first
Mexico City Mexico City ( es, link=no, Ciudad de México, ; abbr.: CDMX; Nahuatl: ''Altepetl Mexico'') is the capital and largest city of Mexico, and the most populous city in North America. One of the world's alpha cities, it is located in the Valley ...
building code was issued in 1942; since 1966, it contains a complete set of regulations for structural design and has served as a reference for municipalities across the country. In 1976, the code adopted a coherent format for all materials and structural systems, based on limit states design philosophy. In February 2004 a new set of seismic codes was issued.


Spain

In Spain, the seismic code is called the "Norma de Construcción Sismorresistente". (See the article in Spanish Wikipedia)


United States

In the
United States The United States of America (U.S.A. or USA), commonly known as the United States (U.S. or US) or America, is a country primarily located in North America. It consists of 50 states, a federal district, five major unincorporated territo ...
, the
Federal Emergency Management Agency The Federal Emergency Management Agency (FEMA) is an agency of the United States Department of Homeland Security (DHS), initially created under President Jimmy Carter by Presidential Reorganization Plan No. 3 of 1978 and implemented by two Exec ...
(FEMA) publishes "Recommended Seismic Provisions for New Buildings and Other Structures. 2015 Edition"."NEHRP Recommended Seismic Provisions for New Buildings and Other Structures. 2015 Edition", Federal Emergency Management Agency
/ref>