HOME

TheInfoList



OR:

The rad is a unit of absorbed radiation dose, defined as 1 rad = 0.01 Gy = 0.01 J/kg. It was originally defined in CGS units in 1953 as the dose causing 100
erg The erg is a unit of energy equal to 10−7joules (100 nJ). It originated in the Centimetre–gram–second system of units (CGS). It has the symbol ''erg''. The erg is not an SI unit. Its name is derived from (), a Greek word meaning 'work' o ...
s of energy to be absorbed by one
gram The gram (originally gramme; SI unit symbol g) is a unit of mass in the International System of Units (SI) equal to one one thousandth of a kilogram. Originally defined as of 1795 as "the absolute weight of a volume of pure water equal to th ...
of matter. The material absorbing the radiation can be human tissue or silicon microchips or any other medium (for example, air, water, lead shielding, etc.). It has been replaced by the gray (Gy) in
SI derived unit SI derived units are units of measurement derived from the seven base units specified by the International System of Units (SI). They can be expressed as a product (or ratio) of one or more of the base units, possibly scaled by an appropriate p ...
s, but is still used in the United States, although this is "strongly discouraged" in Chapter 5.2 of the ''Guide to the SI'', which was written and published by the U.S.
National Institute of Standards and Technology The National Institute of Standards and Technology (NIST) is an agency of the United States Department of Commerce whose mission is to promote American innovation and industrial competitiveness. NIST's activities are organized into physical s ...
. However, the numerically equivalent SI unit, the centigray, is widely used to report absorbed doses within radiotherapy. The roentgen, used to quantify the
radiation exposure Radiation is a moving form of energy, classified into ionizing and non-ionizing type. Ionizing radiation is further categorized into electromagnetic radiation (without matter) and particulate radiation (with matter). Electromagnetic radiation con ...
, may be related to the corresponding absorbed dose by use of the F-factor.


Health effects

A dose of under 100 rad will typically produce no immediate symptoms other than blood changes. A dose of 100 to 200 rad delivered to the entire body in less than a day may cause acute radiation syndrome (ARS), but is usually not fatal. Doses of 200 to 1,000 rad delivered in a few hours will cause serious illness, with poor prognosis at the upper end of the range. Whole body doses of more than 1,000 rad are almost invariably fatal.''The Effects of Nuclear Weapons'', Revised ed., US DOD 1962, pp. 592–593 Therapeutic doses of radiation therapy are often given and tolerated well even at higher doses to treat discrete, well-defined anatomical structures. The same dose given over a longer period of time is less likely to cause ARS. Dose thresholds are about 50% higher for dose rates of 20 rad/h, and even higher for lower dose rates. The
International Commission on Radiological Protection The International Commission on Radiological Protection (ICRP) is an independent, international, non-governmental organization, with the mission to protect people, animals, and the environment from the harmful effects of ionising radiation. Its r ...
maintains a model of health risks as a function of absorbed dose and other factors. That model calculates an effective radiation dose, measured in units of
rem Rem or REM may refer to: Music * R.E.M., an American rock band * ''R.E.M.'' (EP), by Green * "R.E.M." (song), by Ariana Grande Organizations * La République En Marche!, a French centrist political party * Reichserziehungsministerium, in Nazi ...
, which is more representative of the
stochastic Stochastic (, ) refers to the property of being well described by a random probability distribution. Although stochasticity and randomness are distinct in that the former refers to a modeling approach and the latter refers to phenomena themselv ...
risk than the absorbed dose in rad. In most power plant scenarios, where the radiation environment is dominated by X- or
gamma Gamma (uppercase , lowercase ; ''gámma'') is the third letter of the Greek alphabet. In the system of Greek numerals it has a value of 3. In Ancient Greek, the letter gamma represented a voiced velar stop . In Modern Greek, this letter r ...
rays applied uniformly to the whole body, 1 rad of absorbed dose gives 1 rem of effective dose. In other situations, the effective dose in rem might be thirty times higher or thousands of times lower than the absorbed dose in rad.


Dose examples


History

In the 1930s the roentgen was the most commonly used unit of radiation exposure. This unit is obsolete and no longer clearly defined. One roentgen deposits 0.877 rad in dry air, 0.96 rad in soft tissue, or anywhere from 1 to more than 4 rad in bone depending on the beam energy. These conversions to absorbed energy all depend on the ionizing energy of a standard medium, which is ambiguous in the latest NIST definition. Even where the standard medium is fully defined, the ionizing energy is often not precisely known. In 1940, British physicist Louis Harold Gray, who had been studying the effect of neutron damage on human tissue, together with William Valentine Mayneord and John Read published a paper in which a unit of measure, dubbed the "''gram roentgen''" (symbol: gr) defined as "that amount of neutron radiation which produces an increment in energy in unit volume of tissue equal to the increment of energy produced in unit volume of water by one roentgen of radiation" was proposed. This unit was found to be equivalent to 88 ergs in air. It marked a shift towards measurements based on energy rather than charge. The Röntgen equivalent physical (rep), introduced by Herbert Parker in 1945, was the absorbed energetic dose to tissue before factoring in
relative biological effectiveness In radiobiology, the relative biological effectiveness (often abbreviated as RBE) is the ratio of biological effectiveness of one type of ionizing radiation relative to another, given the same amount of absorbed energy. The RBE is an empiric ...
. The rep has variously been defined as 83 or 93
erg The erg is a unit of energy equal to 10−7joules (100 nJ). It originated in the Centimetre–gram–second system of units (CGS). It has the symbol ''erg''. The erg is not an SI unit. Its name is derived from (), a Greek word meaning 'work' o ...
s per gram of tissue (8.3/9.3
mGy The gray (symbol: Gy) is the unit of ionizing radiation dose in the International System of Units (SI), defined as the absorption of one joule of radiation energy per kilogram of matter. It is used as a unit of the radiation quantity absorbed d ...
) or per cc of tissue. In 1953 the ICRU recommended the rad, equal to 100 erg/g as a new unit of absorbed radiation, but then promoted a switch to the gray in the 1970s. The
International Committee for Weights and Measures The General Conference on Weights and Measures (GCWM; french: Conférence générale des poids et mesures, CGPM) is the supreme authority of the International Bureau of Weights and Measures (BIPM), the intergovernmental organization established i ...
(CIPM) has not accepted the use of the rad. From 1977 to 1998, the US NIST's translations of the SI brochure stated that the CIPM had temporarily accepted the use of the rad (and other radiology units) with SI units since 1969. However, the only related CIPM decisions shown in the appendix are with regards to the
curie In computing, a CURIE (or ''Compact URI'') defines a generic, abbreviated syntax for expressing Uniform Resource Identifiers (URIs). It is an abbreviated URI expressed in a compact syntax, and may be found in both XML and non-XML grammars. A CURI ...
in 1964 and the
radian The radian, denoted by the symbol rad, is the unit of angle in the International System of Units (SI) and is the standard unit of angular measure used in many areas of mathematics. The unit was formerly an SI supplementary unit (before that ...
(symbol: rad) in 1960. The NIST brochures redefined the rad as 0.01 Gy. The CIPM's current SI brochure excludes the rad from the tables of non-SI units accepted for use with the SI. The US NIST clarified in 1998 that it was providing its own interpretations of the SI system, whereby it accepted the rad for use in the US with the SI, while recognizing that the CIPM did not. NIST recommends defining the rad in relation to SI units in every document where this unit is used. Nevertheless, use of the rad remains widespread in the US, where it is still an industry standard. Although the United States Nuclear Regulatory Commission still permits the use of the units
curie In computing, a CURIE (or ''Compact URI'') defines a generic, abbreviated syntax for expressing Uniform Resource Identifiers (URIs). It is an abbreviated URI expressed in a compact syntax, and may be found in both XML and non-XML grammars. A CURI ...
, rad, and
rem Rem or REM may refer to: Music * R.E.M., an American rock band * ''R.E.M.'' (EP), by Green * "R.E.M." (song), by Ariana Grande Organizations * La République En Marche!, a French centrist political party * Reichserziehungsministerium, in Nazi ...
alongside SI units, the
European Union The European Union (EU) is a supranational union, supranational political union, political and economic union of Member state of the European Union, member states that are located primarily in Europe, Europe. The union has a total area of ...
required that its use for "public health ... purposes" be phased out by 31 December 1985.


Radiation-related quantities

The following table shows radiation quantities in SI and non-SI units:


See also

*
Becquerel The becquerel (; symbol: Bq) is the unit of radioactivity in the International System of Units (SI). One becquerel is defined as the activity of a quantity of radioactive material in which one nucleus decays per second. For applications relatin ...
* Curie (unit) *
Radiation In physics, radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium. This includes: * ''electromagnetic radiation'', such as radio waves, microwaves, infrared, visi ...
*
Gray (unit) The gray (symbol: Gy) is the unit of ionizing radiation dose in the International System of Units (SI), defined as the absorption of one joule of radiation energy per kilogram of matter. It is used as a unit of the radiation quantity absorbed do ...
* Roentgen (unit) *
Roentgen equivalent man The roentgen equivalent man (rem) is a CGS unit of equivalent dose, effective dose, and committed dose, which are dose measures used to estimate potential health effects of low levels of ionizing radiation on the human body. Quantities measu ...
(rem) *
Sievert The sievert (symbol: SvNot be confused with the sverdrup or the svedberg, two non-SI units that sometimes use the same symbol.) is a unit in the International System of Units (SI) intended to represent the stochastic health risk of ionizing rad ...
* Order of magnitude (unit)


References

{{Radiation protection, state=collapsed Units of radiation dose Non-SI metric units es:Dosis absorbida#Unidades antiguas