A flexible alternating current transmission system (FACTS) is a system composed of static equipment used for the
alternating current Alternating current (AC) is an electric current which periodically reverses direction and changes its magnitude continuously with time in contrast to direct current (DC) which flows only in one direction. Alternating current is the form in which ...
(AC) transmission of electrical energy. It is meant to enhance controllability and increase power transfer capability of the network. It is generally a power electronics-based system. FACTS is defined by the Institute of Electrical and Electronics Engineers (IEEE) as "a power electronic based system and other static equipment that provide control of one or more AC transmission system parameters to enhance controllability and increase power transfer capability". According to Siemens, "FACTS Increase the reliability of AC grids and reduce power delivery costs. They improve transmission quality and efficiency of power transmission by supplying inductive or reactive power to grid.Flexible AC Transmission Systems (FACTS) - Siemens
/ref>


Technology


Shunt compensation

In shunt compensation, power system is connected in shunt (parallel) with the FACTS. It works as a controllable
current source A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it. A current source is the dual of a voltage source. The term ''current sink'' is sometimes used for sources fed ...
. Shunt compensation is of two types: ; Shunt capacitive compensation: This method is used to improve the power factor. Whenever an inductive load is connected to the transmission line, power factor lags because of lagging load current. To compensate, a shunt capacitor is connected which draws the current leading the source voltage. The net result is improvement in power factor. ; Shunt inductive compensation: This method is used either when charging the transmission line, or, when there is very low load at the receiving end. Due to very low, or no load – very low current flows through the transmission line. Shunt capacitance in the transmission line causes voltage amplification ( Ferranti effect). The receiving end voltage may become double the sending end voltage (generally in case of very long transmission lines). To compensate, shunt inductors are connected across the transmission line. The power transfer capability is thereby increased depending upon the power equation P=\left(\frac\right)\sin(\delta) where \delta is the power angle.


Theory

In the case of a no-loss line, voltage magnitude at the receiving end is the same as voltage magnitude at the sending end: Vs = Vr = V. Transmission results in a phase lag \delta that depends on line reactance X. : \begin \underline &= V \cos\left(\frac\right) + jV \sin\left(\frac\right) \\ pt \underline &= V \cos\left(\frac\right) - jV \sin\left(\frac\right) \\ pt \underline &= \frac = \frac \end As it is a no-loss line, active power P is the same at any point of the line: : P_s=P_r=P=V \cos\left(\frac\right) \cdot \frac=\frac\sin(\delta) Reactive power at sending end is the opposite of reactive power at receiving end: : Q_s = -Q_r = Q = V\sin\left(\frac\right) \cdot \frac = \frac(1 - \cos\delta) As \delta is very small, active power mainly depends on \delta whereas reactive power mainly depends on voltage magnitude.


Series compensation

FACTS for series compensation modify line impedance: X is decreased so as to increase the transmittable active power. However, more reactive power must be provided. : \begin P &= \frac\sin(\delta) \\ pt Q &= \frac(1 - \cos(\delta)) \end


Shunt compensation

Reactive current is injected into the line to maintain voltage magnitude. Transmittable active power is increased but more reactive power is to be provided.
: \begin P &= \frac\sin\left(\frac\right)\\ pt Q &= \frac\left -\cos\left(\frac\right)\right \end


Examples of series compensation

*
Static synchronous series compensator A static synchronous series compensator (SSSC) is a type of flexible AC transmission system which consists of a solid-state voltage source inverter coupled with a transformer that is connected in series with a transmission line. This device can i ...
(SSSC) * Thyristor-controlled series capacitor (TCSC): a series
capacitor A capacitor is a device that stores electrical energy in an electric field by virtue of accumulating electric charges on two close surfaces insulated from each other. It is a passivity (engineering), passive electronic component with two termi ...
bank is shunted by a thyristor-controlled
inductor reactor An inductor, also called a coil, choke, or reactor, is a passive two-terminal electrical component that stores energy in a magnetic field when electric current flows through it. An inductor typically consists of an insulated wire wound into a ...
* Thyristor-controlled series reactor (TCSR): a series reactor bank is shunted by a thyristor-controlled reactor * Thyristor-switched series capacitor (TSSC): a series capacitor bank is shunted by a thyristor-switched reactor * Thyristor-switched series reactor (TSSR): a series reactor bank is shunted by a thyristor-switched reactor


Examples of shunt compensation

* Static synchronous compensator (
STATCOM A static synchronous compensator (STATCOM), originally known as a static synchronous condenser (STATCON), is a regulating device shunt-connected to alternating current electricity transmission network. It is based on a power electronics voltage-so ...
); previously known as a static condenser (STATCON) *
Static VAR compensator A static VAR compensator (SVC) is a set of electrical devices for providing fast-acting reactive power on high-voltage electricity transmission networks. SVCs are part of the flexible AC transmission system device family, regulating voltage, powe ...
(SVC). Most common SVCs are: ** Thyristor-controlled reactor (TCR): reactor is connected in series with a bidirectional thyristor valve. The thyristor valve is phase-controlled. Equivalent reactance is varied continuously. ** Thyristor-switched reactor (TSR): Same as TCR but thyristor is either in zero- or full- conduction. Equivalent reactance is varied in stepwise manner. ** Thyristor-switched capacitor (TSC): capacitor is connected in series with a bidirectional thyristor valve. Thyristor is either in zero- or full- conduction. Equivalent reactance is varied in stepwise manner. ** Mechanically-switched capacitor (MSC): capacitor is switched by circuit-breaker. It aims at compensating steady state reactive power. It is switched only a few times a day.


See also

*
Static synchronous series compensator A static synchronous series compensator (SSSC) is a type of flexible AC transmission system which consists of a solid-state voltage source inverter coupled with a transformer that is connected in series with a transmission line. This device can i ...
*
HVDC A high-voltage direct current (HVDC) electric power transmission system (also called a power superhighway or an electrical superhighway) uses direct current (DC) for electric power transmission, in contrast with the more common alternating curren ...


References

; In-line references ; General references * Narain G. Hingorani, Laszlo Gyugyi ''Understanding FACTS: Concepts and Technology of Flexible AC Transmission Systems'', Wiley-IEEE Press, December 1999. * Xiao-Ping Zhang, Christian Rehtanz, Bikash Pal, ''Flexible AC Transmission Systems: Modelling and Control'', Springer, March 2006. . https://link.springer.com/book/10.1007%2F3-540-30607-2 * Xiao-Ping Zhang, Christian Rehtanz, Bikash Pal, ''Flexible AC Transmission Systems: Modelling and Control'', 2nd Edition, Springer, Feb 2012, (Print) 978-3-642-28241-6 (Online), https://link.springer.com/book/10.1007%2F978-3-642-28241-6 * A. Edris, R. Adapa, M.H. Baker, L. Bohmann, K. Clark, K. Habashi, L. Gyugyi, J. Lemay, A. Mehraban, A.K. Myers, J. Reeve, F. Sener, D.R. Torgerson, R.R. Wood, ''Proposed Terms and Definitions for Flexible AC Transmission System (FACTS)'', IEEE Transactions on Power Delivery, Vol. 12, No. 4, October 1997. doi:&nbs
10.1109/61.634216
http://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=00634216 {{refend Electric power transmission Power engineering