An electrostatic precipitator (ESP) is a filterless device that removes fine particles, like dust and smoke, from a flowing gas using the force of an induced electrostatic charge minimally impeding the flow of gases through the unit. In contrast to wet scrubbers, which apply energy directly to the flowing fluid medium, an ESP applies energy only to the particulate matter being collected and therefore is very efficient in its consumption of energy (in the form of electricity).


Invention of the electrostatic precipitator

The first use of
corona discharge A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air (or other fluid) has undergone electrical breakdown ...
to remove particles from an aerosol was by Hohlfeld in 1824. However, it was not commercialized until almost a century later. In 1907
Frederick Gardner Cottrell Frederick Gardner Cottrell (January 10, 1877 – November 16, 1948) was an American physical chemist, inventor and philanthropist. He is best known for his invention of the electrostatic precipitator, one of the first inventions designed to ...
, a professor of chemistry at the
University of California, Berkeley The University of California, Berkeley (UC Berkeley, Berkeley, Cal, or California) is a public land-grant research university in Berkeley, California. Established in 1868 as the University of California, it is the state's first land-grant un ...
, applied for a patent on a device for charging particles and then collecting them through
electrostatic Electrostatics is a branch of physics that studies electric charges at rest ( static electricity). Since classical times, it has been known that some materials, such as amber, attract lightweight particles after rubbing. The Greek word for ...
attraction—the first electrostatic precipitator. Cottrell first applied the device to the collection of
sulphuric acid Sulfuric acid (American spelling and the preferred IUPAC name) or sulphuric acid ( Commonwealth spelling), known in antiquity as oil of vitriol, is a mineral acid composed of the elements sulfur, oxygen and hydrogen, with the molecular for ...
mist and
lead oxide Lead oxides are a group of inorganic compounds with formulas including lead (Pb) and oxygen (O). Common lead oxides include: * Lead(II) oxide, PbO, litharge (red), massicot (yellow) * Lead(II,IV) oxide Lead(II,IV) oxide, also called red lead o ...
fumes emitted from various acid-making and
smelting Smelting is a process of applying heat to ore, to extract a base metal. It is a form of extractive metallurgy. It is used to extract many metals from their ores, including silver, iron, copper, and other base metals. Smelting uses heat and a c ...
activities. Wine-producing
vineyards A vineyard (; also ) is a plantation of grape-bearing vines, grown mainly for winemaking, but also raisins, table grapes and non-alcoholic grape juice. The science, practice and study of vineyard production is known as viticulture. Vineyards ...
in northern California were being adversely affected by the lead emissions. At the time of Cottrell's invention, the theoretical basis for operation was not understood. The operational theory was developed later in Germany, with the work of Walter Deutsch and the formation of the Lurgi company. Cottrell used proceeds from his invention to fund scientific research through the creation of a foundation called
Research Corporation Research Corporation for Science Advancement (RCSA) is an organization in the United States devoted to the advancement of science, funding research projects in the physical sciences. Since 1912, Research Corporation for Science Advancement has id ...
in 1912, to which he assigned the patents. The intent of the organization was to bring inventions made by educators (such as Cottrell) into the commercial world for the benefit of society at large. The operation of Research Corporation is funded by royalties paid by commercial firms after commercialization occurs. Research Corporation has provided vital funding to many scientific projects: Goddard's rocketry experiments, Lawrence's
cyclotron A cyclotron is a type of particle accelerator invented by Ernest O. Lawrence in 1929–1930 at the University of California, Berkeley, and patented in 1932. Lawrence, Ernest O. ''Method and apparatus for the acceleration of ions'', filed: Jan ...
, production methods for vitamins A and B1, among many others. Research Corporation set territories for manufacturers of this technology, which included Western Precipitation (Los Angeles), Lodge-Cottrell (England), Lurgi Apparatebau-Gesellschaft (Germany), and Japanese Cottrell Corp. (Japan), and was a clearinghouse for any process improvements. However, anti-trust concerns forced Research Corporation to eliminate territory restrictions in 1946.
Electrophoresis Electrophoresis, from Ancient Greek ἤλεκτρον (ḗlektron, "amber") and φόρησις (phórēsis, "the act of bearing"), is the motion of dispersed particles relative to a fluid under the influence of a spatially uniform electric fi ...
is the term used for migration of gas-suspended charged particles in a direct-current
electrostatic field An electric field (sometimes E-field) is the physical field that surrounds electrically charged particles and exerts force on all other charged particles in the field, either attracting or repelling them. It also refers to the physical field fo ...
. Traditional CRT television sets tend to accumulate dust on the screen because of this phenomenon (a CRT is a direct-current machine operating at about 15 kilovolts).


Plate and bar precipitator

The most basic precipitator contains a row of thin vertical wires, and followed by a stack of large flat metal plates oriented vertically, with the plates typically spaced about 1 cm to 18 cm apart, depending on the application. The air stream flows horizontally through the spaces between the wires, and then passes through the stack of plates. A negative voltage of several thousand
volt The volt (symbol: V) is the unit of electric potential, electric potential difference (voltage), and electromotive force in the International System of Units (SI). It is named after the Italian physicist Alessandro Volta (1745–1827). Defin ...
s is applied between wire and plate. If the applied voltage is high enough, an electric
corona discharge A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air (or other fluid) has undergone electrical breakdown ...
ionizes the air around the electrodes, which then ionizes the particles in the air stream. The ionized particles, due to the
electrostatic force Coulomb's inverse-square law, or simply Coulomb's law, is an experimental law of physics that quantifies the amount of force between two stationary, electrically charged particles. The electric force between charged bodies at rest is convention ...
, are diverted towards the grounded plates. Particles build up on the collection plates and are removed from the air stream. A two-stage design (separate charging section ahead of the collecting section) has the benefit of minimizing ozone production, which would adversely affect the health of personnel working in enclosed spaces. For shipboard
engine room On a ship, the engine room (ER) is the compartment where the machinery for marine propulsion is located. To increase a vessel's safety and chances of surviving damage, the machinery necessary for the ship's operation may be segregated into var ...
s where
gearbox Propulsion transmission is the mode of transmitting and controlling propulsion power of a machine. The term ''transmission'' properly refers to the whole drivetrain, including clutch, gearbox, prop shaft (for rear-wheel drive vehicles), diff ...
es generate an oil mist, two-stage ESP's are used to clean the air, improving the operating environment and preventing buildup of flammable oil fog accumulations. Collected oil is returned to the gear lubricating system.


Collection efficiency (''R'')

Precipitator performance is very sensitive to two particulate properties: 1) electrical resistivity; and 2)
particle size distribution The particle-size distribution (PSD) of a powder, or granular material, or particles dispersed in fluid, is a list of values or a mathematical function that defines the relative amount, typically by mass, of particles present according to size. Sig ...
. These properties can be measured economically and accurately in the laboratory, using standard tests. Resistivity can be determined as a function of temperature in accordance with IEEE Standard 548. This test is conducted in an air environment containing a specified moisture concentration. The test is run as a function of ascending or descending temperature, or both. Data is acquired using an average ash layer electric field of 4 kV/cm. Since relatively low applied voltage is used and no sulfuric acid vapor is present in the test environment, the values obtained indicate the maximum ash resistivity. In an ESP, where particle charging and discharging are key functions, resistivity is an important factor that significantly affects collection efficiency. While resistivity is an important phenomenon in the inter-electrode region where most particle charging takes place, it has a particularly important effect on the dust layer at the collection electrode where discharging occurs. Particles that exhibit high resistivity are difficult to charge. But once charged, they do not readily give up their acquired charge on arrival at the collection electrode. On the other hand, particles with low resistivity easily become charged and readily release their charge to the grounded collection plate. Both extremes in resistivity impede the efficient functioning of ESPs. ESPs work best under normal resistivity conditions. Resistivity, which is a characteristic of particles in an electric field, is a measure of a particle's resistance to transferring charge (both accepting and giving up charges). Resistivity is a function of a particle's chemical composition as well as flue gas operating conditions such as temperature and moisture. Particles can have high, moderate (normal), or low resistivity. Bulk resistivity is defined using a more general version of Ohm’s Law, as given in Equation () below: Where: ''E'' is the Electric field strength.Unit:-(V/cm); ''j'' is the Current density.Unit:-(A/cm2); and ''ρ'' is the Resistivity.Unit:-(Ohm-cm) A better way of displaying this would be to solve for resistivity as a function of applied voltage and current, as given in Equation () below: Where: ρ = Resistivity.Unit:-(Ohm-cm) V = The applied DC potential.Unit:-(Volts); I = The measured current.Unit:-(Amperes); l = The ash layer thickness.Unit:-(cm); and A = The current measuring electrode face area.Unit:-(cm2). Resistivity is the electrical resistance of a dust sample 1.0 cm2 in cross-sectional area, 1.0 cm thick, and is recorded in units of ohm-cm. A method for measuring resistivity will be described in this article. The table below, gives value ranges for low, normal, and high resistivity.


Dust layer resistance

Resistance affects electrical conditions in the dust layer by a potential electric field (voltage drop) being formed across the layer as negatively charged particles arrive at its surface and leak their electrical charges to the collection plate. At the metal surface of the electrically grounded collection plate, the voltage is zero, whereas at the outer surface of the dust layer, where new particles and ions are arriving, the electrostatic voltage caused by the gas ions can be quite high. The strength of this electric field depends on the resistance and thickness of the dust layer. In high-resistance dust layers, the dust is not sufficiently conductive, so electrical charges have difficulty moving through the dust layer. Consequently, electrical charges accumulate on and beneath the dust layer surface, creating a strong electric field. Voltages can be greater than 10,000 volts. Dust particles with high resistance are held too strongly to the plate, making them difficult to remove and causing trapping problems. In low resistance dust layers, the corona current is readily passed to the grounded collection electrode. Therefore, a relatively weak electric field, of several thousand volts, is maintained across the dust layer. Collected dust particles with low resistance do not adhere strongly enough to the collection plate. They are easily dislodged and become retained in the gas stream. The electrical conductivity of a bulk layer of particles depends on both surface and volume factors. Volume conduction, or the motions of electrical charges through the interiors of particles, depends mainly on the composition and temperature of the particles. In the higher temperature regions, above , volume conduction controls the conduction mechanism. Volume conduction also involves ancillary factors, such as compression of the particle layer, particle size and shape, and surface properties. Volume conduction is represented in the figures as a straight-line at temperatures above . At temperatures below about , electrical charges begin to flow across surface moisture and chemical films adsorbed onto the particles. Surface conduction begins to lower the resistivity values and bend the curve downward at temperatures below . These films usually differ both physically and chemically from the interiors of the particles owing to adsorption phenomena. Theoretical calculations indicate that moisture films only a few molecules thick are adequate to provide the desired surface conductivity. Surface conduction on particles is closely related to surface-leakage currents occurring on electrical insulators, which have been extensively studied. An interesting practical application of surface-leakage is the determination of
dew point The dew point is the temperature to which air must be cooled to become saturated with water vapor, assuming constant air pressure and water content. When cooled below the dew point, moisture capacity is reduced and airborne water vapor will ...
by measurement of the current between adjacent electrodes mounted on a glass surface. A sharp rise in current signals the formation of a moisture film on the glass. This method has been used effectively for determining the marked rise in dew point, which occurs when small amounts of sulfuric acid vapor are added to an atmosphere (commercial Dewpoint Meters are available on the market). The following discussion of normal, high, and low resistance applies to ESPs operated in a dry state; resistance is not a problem in the operation of wet ESPs because of the moisture concentration in the ESP. The relationship between moisture content and resistance is explained later in this work.


Normal resistivity

As stated above, ESPs work best under normal resistivity conditions. Particles with normal resistivity do not rapidly lose their charge on arrival at the collection electrode. These particles slowly leak their charge to grounded plates and are retained on the collection plates by intermolecular adhesive and cohesive forces. This allows a particulate layer to be built up and then dislodged from the plates by rapping. Within the range of normal dust resistivity (between 107 and 2 × 1010 ohm-cm), fly ash is collected more easily than dust having either low or high resistivity.


High resistivity

If the voltage drop across the dust layer becomes too high, several adverse effects can occur. First, the high voltage drop reduces the voltage difference between the discharge electrode and collection electrode, and thereby reduces the electrostatic field strength used to drive the gas ion-charged particles over to the collected dust layer. As the dust layer builds up, and the electrical charges accumulate on the surface of the dust layer, the voltage difference between the discharge and collection electrodes decreases. The migration velocities of small particles are especially affected by the reduced electric field strength. Another problem that occurs with high resistivity dust layers is called back corona. This occurs when the potential drop across the dust layer is so great that corona discharges begin to appear in the gas that is trapped within the dust layer. The dust layer breaks down electrically, producing small holes or craters from which back corona discharges occur. Positive gas ions are generated within the dust layer and are accelerated toward the "negatively charged" discharge electrode. The positive ions reduce some of the negative charges on the dust layer and neutralize some of the negative ions on the "charged particles" heading toward the collection electrode. Disruptions of the normal corona process greatly reduce the ESP's collection efficiency, which in severe cases, may fall below 50% . When back corona is present, the dust particles build up on the electrodes forming a layer of insulation. Often this can not be repaired without bringing the unit offline. The third, and generally most common problem with high resistivity dust is increased electrical sparking. When the sparking rate exceeds the "set spark rate limit," the automatic controllers limit the operating voltage of the field. This causes reduced particle charging and reduced migration velocities toward the collection electrode. High resistivity can generally be reduced by doing the following: * Adjusting the temperature; * Increasing moisture content; * Adding conditioning agents to the gas stream; * Increasing the collection surface area; and * Using hot-side precipitators (occasionally and with foreknowledge of sodium depletion). Thin dust layers and high-resistivity dust especially favor the formation of back corona craters. Severe back corona has been observed with dust layers as thin as 0.1 mm, but a dust layer just over one particle thick can reduce the sparking voltage by 50%. The most marked effects of back corona on the current-voltage characteristics are: # Reduction of the spark over voltage by as much as 50% or more; # Current jumps or discontinuities caused by the formation of stable back-corona craters; and # Large increase in maximum corona current, which just below spark over corona gap may be several times the normal current. The Figure below and to the left shows the variation in resistivity with changing gas temperature for six different industrial dusts along with three coal-fired fly ashes. The Figure on the right illustrates resistivity values measured for various chemical compounds that were prepared in the laboratory. Results for Fly Ash A (in the figure to the left) were acquired in the ascending temperature mode. These data are typical for a moderate to high combustibles content ash. Data for Fly Ash B are from the same sample, acquired during the descending temperature mode. The differences between the ascending and descending temperature modes are due to the presence of unburned combustibles in the sample. Between the two test modes, the samples are equilibrated in dry air for 14 hours (overnight) at . This overnight annealing process typically removes between 60% and 90% of any unburned combustibles present in the samples. Exactly how carbon works as a charge carrier is not fully understood, but it is known to significantly reduce the resistivity of a dust. Carbon can act, at first, like a high resistivity dust in the precipitator. Higher voltages can be required in order for corona generation to begin. These higher voltages can be problematic for the TR-Set controls. The problem lies in onset of corona causing large amounts of current to surge through the (low resistivity) dust layer. The controls sense this surge as a spark. As precipitators are operated in spark-limiting mode, power is terminated and the corona generation cycle re-initiates. Thus, lower power (current) readings are noted with relatively high voltage readings. The same thing is believed to occur in laboratory measurements. Parallel plate geometry is used in laboratory measurements without corona generation. A stainless steel cup holds the sample. Another stainless steel electrode weight sits on top of the sample (direct contact with the dust layer). As voltage is increased from small amounts (e.g. 20 V), no current is measured. Then, a threshold voltage level is reached. At this level, current surges through the sample... so much so that the voltage supply unit can trip off. After removal of the unburned combustibles during the above-mentioned annealing procedure, the descending temperature mode curve shows the typical inverted “V” shape one might expect.


Low resistivity

Particles that have low resistivity are difficult to collect because they are easily charged (very conductive) and rapidly lose their charge on arrival at the collection electrode. The particles take on the charge of the collection electrode, bounce off the plates, and become re-entrained in the gas stream. Thus, attractive and repulsive electrical forces that are normally at work at normal and higher resistivities are lacking, and the binding forces to the plate are considerably lessened. Examples of low-resistivity dusts are unburned carbon in fly ash and carbon black. If these conductive particles are coarse, they can be removed upstream of the precipitator by using a device such as a cyclone mechanical collector. The addition of liquid ammonia () into the gas stream as a conditioning agent has found wide use in recent years. It is theorized that ammonia reacts with contained in the flue gas to form an ammonium sulfate compound that increases the cohesivity of the dust. This additional cohesivity makes up for the loss of electrical attraction forces. The table below summarizes the characteristics associated with low, normal and high resistivity dusts. The moisture content of the flue gas stream also affects particle resistivity. Increasing the moisture content of the gas stream by spraying water or injecting steam into the duct work preceding the ESP lowers the resistivity. In both temperature adjustment and moisture conditioning, one must maintain gas conditions above the dew point to prevent corrosion problems in the ESP or downstream equipment. The figure to the right shows the effect of temperature and moisture on the resistivity of a cement dust. As the percentage of moisture in the gas stream increases from 6 to 20%, the resistivity of the dust dramatically decreases. Also, raising or lowering the temperature can decrease cement dust resistivity for all the moisture percentages represented. The presence of in the gas stream has been shown to favor the electrostatic precipitation process when problems with high resistivity occur. Most of the sulfur content in the coal burned for combustion sources converts to . However, approximately 1% of the sulfur converts to . The amount of in the flue gas normally increases with increasing sulfur content of the coal. The resistivity of the particles decreases as the sulfur content of the coal increases. Other conditioning agents, such as sulfuric acid, ammonia, sodium chloride, and soda ash (sometimes as raw trona), have also been used to reduce particle resistivity. Therefore, the chemical composition of the flue gas stream is important with regard to the resistivity of the particles to be collected in the ESP. The table below lists various conditioning agents and their mechanisms of operation. If injection of ammonium sulfate occurs at a temperature greater than about , dissociation into ammonia and sulfur trioxide results. Depending on the ash, may preferentially interact with fly ash as conditioning. The remainder recombines with ammonia to add to the space charge as well as increase cohesiveness of the ash. More recently, it has been recognized that a major reason for loss of efficiency of the electrostatic precipitator is due to particle buildup on the charging wires in addition to the collection plates (Davidson and McKinney, 1998). This is easily remedied by making sure that the wires themselves are cleaned at the same time that the collecting plates are cleaned. Sulfuric acid vapor () enhances the effects of water vapor on surface conduction. It is physically adsorbed within the layer of moisture on the particle surfaces. The effects of relatively small amounts of acid vapor can be seen in the figure below and to the right. The inherent resistivity of the sample at is 5 × 1012 ohm-cm. An equilibrium concentration of just 1.9 ppm sulfuric acid vapor lowers that value to about 7 × 109 ohm-cm.


Modern industrial electrostatic precipitators

ESPs continue to be excellent devices for control of many industrial particulate emissions, including smoke from electricity-generating utilities (coal and oil fired), salt cake collection from
black liquor In industrial chemistry, black liquor is the by-product from the kraft process when digesting pulpwood into paper pulp removing lignin, hemicelluloses and other extractives from the wood to free the cellulose fibers. The equivalent material i ...
boilers in pulp mills, and catalyst collection from fluidized bed catalytic cracker units in oil refineries to name a few. These devices treat gas volumes from several hundred thousand
ACFM Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqua ...
to 2.5 million ACFM (1,180 m³/s) in the largest coal-fired boiler applications. For a coal-fired boiler the collection is usually performed downstream of the air preheater at about which provides optimal resistivity of the coal-ash particles. For some difficult applications with low-sulfur fuel hot-end units have been built operating above . The original parallel plate–weighted wire design (see figure of Plate and Bar precipitator above) has evolved as more efficient (and robust) discharge electrode designs were developed, today focusing on rigid (pipe-frame) discharge electrodes to which many sharpened spikes are attached (barbed wire), maximizing
corona Corona (from the Latin for 'crown') most commonly refers to: * Stellar corona, the outer atmosphere of the Sun or another star * Corona (beer), a Mexican beer * Corona, informal term for the coronavirus SARS-CoV-2, which causes the COVID-19 di ...
production. Transformer-rectifier systems apply voltages of at relatively high current densities. Modern controls, such as an automatic voltage control, minimize
electric spark An electric spark is an abrupt electrical discharge that occurs when a sufficiently high electric field creates an ionized, electrically conductive channel through a normally-insulating medium, often air or other gases or gas mixtures. Michael F ...
ing and prevent arcing (sparks are quenched within 1/2 cycle of the TR set), avoiding damage to the components. Automatic plate-rapping systems and hopper-evacuation systems remove the collected particulate matter while on line, theoretically allowing ESPs to stay in continuous operation for years at a time.


Electrostatic sampling for bioaerosols

Electrostatic precipitators can be used to sample biological airborne particles or aerosol for analysis. Sampling for bioaerosols requires precipitator designs optimised with a liquid counter electrode, which can be used to sample biological particles, e.g. viruses, directly into a small liquid volume to reduce unnecessary sample dilution. See
Bioaerosol Bioaerosols (short for biological aerosols) are a subcategory of particles released from terrestrial and marine ecosystems into the atmosphere. They consist of both living and non-living components, such as fungi, pollen, bacteria and viruses. Commo ...
s for more details.


Wet electrostatic precipitator

A wet electrostatic precipitator (WESP or wet ESP) operates with
water vapor (99.9839 °C) , - , Boiling point , , - , specific gas constant , 461.5 J/( kg·K) , - , Heat of vaporization , 2.27 MJ/kg , - , Heat capacity , 1.864 kJ/(kg·K) Water vapor, water vapour or aqueous vapor is the gaseous p ...
saturated air streams (100% relative humidity). WESPs are commonly used to remove liquid droplets such as sulfuric acid mist from industrial process gas streams. The WESP is also commonly used where the gases are high in moisture content, contain combustible particulate, or have particles that are sticky in nature.


Household electrostatic air cleaners

Plate precipitators are commonly marketed to the public as
air purifier An air purifier or air cleaner is a device which removes contaminants from the air in a room to improve indoor air quality. These devices are commonly marketed as being beneficial to allergy sufferers and asthmatics, and at reducing or eliminating ...
devices or as a permanent replacement for furnace filters, but all have the undesirable attribute of being somewhat messy to clean. A negative side-effect of electrostatic precipitation devices is the potential production of toxic
ozone Ozone (), or trioxygen, is an inorganic molecule with the chemical formula . It is a pale blue gas with a distinctively pungent smell. It is an allotrope of oxygen that is much less stable than the diatomic allotrope , breaking down in the l ...
and . However, electrostatic precipitators offer benefits over other air purifications technologies, such as
HEPA HEPA (, high-efficiency particulate air) filter, also known as high-efficiency particulate absorbing filter and high-efficiency particulate arrestance filter, is an efficiency standard of air filters. Filters meeting the HEPA standard must ...
filtration, which require expensive filters and can become "production sinks" for many harmful forms of bacteria. With electrostatic precipitators, if the collection plates are allowed to accumulate large amounts of particulate matter, the particles can sometimes bond so tightly to the metal plates that vigorous washing and scrubbing may be required to completely clean the collection plates. The close spacing of the plates can make thorough cleaning difficult, and the stack of plates often cannot be easily disassembled for cleaning. One solution, suggested by several manufacturers, is to wash the collector plates in a
dishwasher A dishwasher is a machine that is used to clean dishware, cookware, and cutlery automatically. Unlike manual dishwashing, which relies heavily on physical scrubbing to remove soiling, the mechanical dishwasher cleans by spraying hot water, ty ...
. Some consumer precipitation filters are sold with special soak-off cleaners, where the entire plate array is removed from the precipitator and soaked in a large container overnight, to help loosen the tightly bonded
particulates Particulates – also known as atmospheric aerosol particles, atmospheric particulate matter, particulate matter (PM) or suspended particulate matter (SPM) – are microscopic particles of solid or liquid matter suspended in the air. Th ...
. A study by the
Canada Mortgage and Housing Corporation Canada Mortgage and Housing Corporation (CMHC) (french: Société canadienne d'hypothèques et de logement) (SCHL) is Canada's national housing agency, and state-owned mortgage insurer. It was originally established after World War II, to help re ...
testing a variety of
forced-air A forced-air central heating system is one which uses air as its heat transfer medium. These systems rely on ductwork, vents, and plenums as means of air distribution, separate from the actual heating and air conditioning systems. The return ...
furnace filters found that ESP filters provided the best, and most cost-effective means of cleaning air using a forced-air system. The first portable electrostatic air filter systems for homes was marketed in 1954 by Raytheon.


See also

*
Scrubber Scrubber systems (e.g. chemical scrubbers, gas scrubbers) are a diverse group of air pollution control devices that can be used to remove some particulates and/or gases from industrial exhaust streams. An early application of a carbon dioxide sc ...
* Air ionizer *
Ozone generator Ozone (), or trioxygen, is an inorganic molecule with the chemical formula . It is a pale blue gas with a distinctively pungent smell. It is an allotrope of oxygen that is much less stable than the diatomic allotrope , breaking down in the lo ...
* Air Purge System