An electrometer is an
electrical Electricity is the set of physical phenomena associated with the presence and motion of matter that has a property of electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described ...
instrument for measuring
electric charge Electric charge is the physical property of matter that causes charged matter to experience a force when placed in an electromagnetic field. Electric charge can be ''positive'' or ''negative'' (commonly carried by protons and electrons res ...
or electrical potential difference. There are many different types, ranging from historical handmade mechanical instruments to high-precision electronic devices. Modern electrometers based on
vacuum tube A vacuum tube, electron tube, valve (British usage), or tube (North America), is a device that controls electric current flow in a high vacuum between electrodes to which an electric potential difference has been applied. The type known as ...
or solid-state technology can be used to make voltage and charge measurements with very low leakage currents, down to 1 femtoampere. A simpler but related instrument, the
electroscope The electroscope is an early scientific instrument used to detect the presence of electric charge on a body. It detects charge by the movement of a test object due to the Coulomb electrostatic force on it. The amount of charge on an object is ...
, works on similar principles but only indicates the relative magnitudes of voltages or charges.


Historical electrometers


Gold-leaf electroscope

The gold-leaf electroscope was one of the instruments used to indicate electric charge. It is still used for science demonstrations but has been superseded in most applications by electronic measuring instruments. The instrument consists of two thin leaves of gold foil suspended from an
electrode An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials ...
. When the electrode is charged by induction or by contact, the leaves acquire similar electric charges and repel each other due to the
Coulomb force Coulomb's inverse-square law, or simply Coulomb's law, is an experimental law of physics that quantifies the amount of force between two stationary, electrically charged particles. The electric force between charged bodies at rest is convention ...
. Their separation is a direct indication of the net charge stored on them. On the glass opposite the leaves, pieces of tin foil may be pasted, so that when the leaves diverge fully they may discharge into the ground. The leaves may be enclosed in a glass envelope to protect them from drafts, and the envelope may be evacuated to minimize charge leakage. A further cause of charge leakage is
ionizing radiation Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can travel ...
, so to prevent this, the electrometer must be surrounded by
lead Lead is a chemical element with the symbol Pb (from the Latin ) and atomic number 82. It is a heavy metal that is denser than most common materials. Lead is soft and malleable, and also has a relatively low melting point. When freshly cut, ...
shielding. This principle has been used to detect ionizing radiation, as seen in the quartz fibre electrometer and
Kearny fallout meter The Kearny fallout meter, or KFM, is an expedient radiation meter. It is designed such that someone with a normal mechanical ability would be able to construct it before or during a nuclear attack, using common household items. The Kearny fallo ...
. This type of electroscope usually acts as an indicator and not a measuring device, although it can be calibrated. A calibrated electrometer with a more robust aluminium indicator was invented by Ferdinand Braun and first described in 1887. According to Braun, the standard gold-leaf electrometer is good up to about with a resolution of using an ocular micrometer. For larger voltages up to Braun's instrument can achieve a resolution of . The instrument was developed in the 18th century by several researchers, among them
Abraham Bennet Abraham Bennet FRS (baptised 20 December 1749 – buried 9 May 1799) was an English clergyman and physicist, the inventor of the gold-leaf electroscope and developer of an improved magnetometer. Though he was cited by Alessandro Volta as a key ...
(1787) and
Alessandro Volta Alessandro Giuseppe Antonio Anastasio Volta (, ; 18 February 1745 – 5 March 1827) was an Italian physicist, chemist and lay Catholic who was a pioneer of electricity and power who is credited as the inventor of the electric battery and th ...
.


Early quadrant electrometer

While the term "quadrant electrometer" eventually referred to Kelvin's version, this term was first used to describe a simpler device. It consists of an upright stem of wood, to which is affixed to a semicircle of ivory. From the center there hangs a light cork ball upon a pivot. When the instrument is placed upon a charged body, the stem participates and repels the cork ball. The amount of repulsion may be read off the graduated semicircle, though the measured angle is not in direct proportion to the charge. Early inventors included William Henley (1770) and Horace-Bénédict de Saussure.


Coulomb's electrometer

Torsion is used to give a measurement more sensitive than repulsion of gold leaves or cork-balls. It consists of a glass cylinder with a glass tube on top. In the axes of the tube is a glass thread, the lower end of this holds a bar of gum lac, with a gilt pith ball at each extremity. Through another aperture on the cylinder, another gum lac rod with gilt balls may be introduced. This is called the carrier rod. If the lower ball of the carrier rod is charged when it is entered into the aperture, this will repel one of the movable balls inside. An index and scale (not pictured) is attached to the top of the twistable glass rod. The number of degrees twisted to bring the balls back together is in exact proportion of the amount of charge of the ball of the carrier rod.
Francis Ronalds Sir Francis Ronalds FRS (21 February 17888 August 1873) was an English scientist and inventor, and arguably the first electrical engineer. He was knighted for creating the first working electric telegraph over a substantial distance. In 1816 ...
, the inaugural Director of the Kew Observatory, made important improvements to the Coulomb torsion balance around 1844 and the modified instrument was sold by London instrument-makers. Ronalds used a thin suspended needle rather than the gum lac bar and replaced the carrier rod with a fixed piece in the plane of the needle. Both were metal, as was the suspending line and its surrounding tube, so that the needle and the fixed piece could be charged directly through wire connections. Ronalds also employed a
Faraday cage A Faraday cage or Faraday shield is an enclosure used to block electromagnetic fields. A Faraday shield may be formed by a continuous covering of conductive material, or in the case of a Faraday cage, by a mesh of such materials. Faraday cages ...
and trialled photography to record the readings continuously. It was the forerunner of Kelvin's quadrant electrometer (described below).


Peltier electrometer

Developed by Peltier, this uses a form of magnetic compass to measure deflection by balancing the electrostatic force with a magnetic needle.


Bohnenberger electrometer

The Bohnenberger electrometer, developed by J. G. F. von Bohnenberger from an invention by T. G. B. Behrens, consists of a single gold leaf suspended vertically between the anode and cathode of a
dry pile upright=1.2, Schematic diagram of a copper–zinc voltaic pile. The copper and zinc discs were separated by cardboard or felt spacers soaked in salt water (the electrolyte). Volta's original piles contained an additional zinc disk at the bottom, ...
. Any charge imparted to the gold leaf causes it to move toward one or the other pole; thus, the sign of the charge as well as its approximate magnitude may be gauged.


Attraction electrometer

Also known as "attracted disk electrometers", attraction electrometers are sensitive balances measuring the attraction between charged disks. William Snow Harris is credited with the invention of this instrument, which was further improved by Lord Kelvin.


Kelvin's quadrant electrometer

Developed by Lord Kelvin, this is the most sensitive and accurate of all the mechanical electrometers. The original design uses a light aluminum sector suspended inside a drum cut into four segments. The segments are insulated and connected diagonally in pairs. The charged aluminum sector is attracted to one pair of segments and repelled from the other. The deflection is observed by a beam of light reflected from a small mirror attached to the sector, just as in a
galvanometer A galvanometer is an electromechanical measuring instrument for electric current. Early galvanometers were uncalibrated, but improved versions, called ammeters, were calibrated and could measure the flow of current more precisely. A galvan ...
. The engraving on the right shows a slightly different form of this electrometer, using four flat plates rather than closed segments. The plates can be connected externally in the conventional diagonal way (as shown), or in a different order for specific applications. A more sensitive form of quadrant electrometer was developed by
Frederick Lindemann Frederick Alexander Lindemann, 1st Viscount Cherwell, ( ; 5 April 18863 July 1957) was a British physicist who was prime scientific adviser to Winston Churchill in World War II. Lindemann was a brilliant intellectual, who cut through bureau ...
. It employs a metal-coated quartz fiber instead of an aluminum sector. The deflection is measured by observing the movement of the fiber under a microscope. Initially used for measuring star light, it was employed for the infrared detection of airplanes in the early stages of
World War II World War II or the Second World War, often abbreviated as WWII or WW2, was a world war that lasted from 1939 to 1945. It involved the World War II by country, vast majority of the world's countries—including all of the great power ...
. Some mechanical electrometers were housed inside a cage often referred to as a “bird cage”. This is a form of
Faraday Cage A Faraday cage or Faraday shield is an enclosure used to block electromagnetic fields. A Faraday shield may be formed by a continuous covering of conductive material, or in the case of a Faraday cage, by a mesh of such materials. Faraday cages ...
that protected the instrument from external electrostatic charges.


Electrograph

Electricity readings may be recorded continuously with a device known as an electrograph.
Francis Ronalds Sir Francis Ronalds FRS (21 February 17888 August 1873) was an English scientist and inventor, and arguably the first electrical engineer. He was knighted for creating the first working electric telegraph over a substantial distance. In 1816 ...
created an early electrograph around 1814 in which the changing electricity made a pattern in a rotating
resin In polymer chemistry and materials science, resin is a solid or highly viscous substance of plant or synthetic origin that is typically convertible into polymers. Resins are usually mixtures of organic compounds. This article focuses on nat ...
-coated plate. It was employed at Kew Observatory and the
Royal Observatory, Greenwich The Royal Observatory, Greenwich (ROG; known as the Old Royal Observatory from 1957 to 1998, when the working Royal Greenwich Observatory, RGO, temporarily moved south from Greenwich to Herstmonceux) is an observatory situated on a hill in ...
in the 1840s to create records of variations in
atmospheric electricity Atmospheric electricity is the study of electrical charges in the Earth's atmosphere (or that of another planet). The movement of charge between the Earth's surface, the atmosphere, and the ionosphere is known as the global atmospheric electr ...
. In 1845, Ronalds invented photographic means of registering the atmospheric electricity. The photosensitive surface was pulled slowly past of the aperture diaphragm of the camera box, which also housed an electrometer, and captured ongoing movements of the electrometer indices as a trace. Kelvin used similar photographic means for his quadrant electrometer (see above) in the 1860s.


Modern electrometers

A modern electrometer is a highly sensitive electronic
voltmeter A voltmeter is an instrument used for measuring electric potential difference between two points in an electric circuit. It is connected in parallel. It usually has a high resistance so that it takes negligible current from the circuit. ...
whose input impedance is so high that the current flowing into it can be considered, for most practical purposes, to be zero. The actual value of input resistance for modern electronic electrometers is around 1014Ω, compared to around 1010Ω for nanovoltmeters. Owing to the extremely high input impedance, special design considerations (such as
driven shield A driven shield is a method of electrical shielding used to protect low-current circuits against leakage current. A driven shield is often referred to as a driven guard, especially when applied to PCB traces. Description It is used in situa ...
s and special insulation materials) must be applied to avoid leakage current. Among other applications, electrometers are used in
nuclear physics Nuclear physics is the field of physics that studies atomic nuclei and their constituents and interactions, in addition to the study of other forms of nuclear matter. Nuclear physics should not be confused with atomic physics, which studies t ...
experiments as they are able to measure the tiny charges left in matter by the passage of
ionizing radiation Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can travel ...
. The most common use for modern electrometers is the measurement of radiation with ionization chambers, in instruments such as
geiger counter A Geiger counter (also known as a Geiger–Müller counter) is an electronic instrument used for detecting and measuring ionizing radiation. It is widely used in applications such as radiation dosimetry, radiological protection, experimental p ...
s.


Vibrating reed electrometers

Vibrating reed electrometers use a variable
capacitor A capacitor is a device that stores electrical energy in an electric field by virtue of accumulating electric charges on two close surfaces insulated from each other. It is a passive electronic component with two terminals. The effect of ...
formed between a moving electrode (in the form of a vibrating reed) and a fixed input electrode. As the distance between the two electrodes varies, the capacitance also varies and electric charge is forced in and out of the capacitor. The
alternating current Alternating current (AC) is an electric current which periodically reverses direction and changes its magnitude continuously with time in contrast to direct current (DC) which flows only in one direction. Alternating current is the form in whic ...
signal produced by the flow of this charge is amplified and used as an analogue for the DC voltage applied to the capacitor. The DC input resistance of the electrometer is determined solely by the leakage resistance of the capacitor, and is typically extremely high, (although its AC input impedance is lower). For convenience of use, the vibrating reed assembly is often attached by a cable to the rest of the electrometer. This allows for a relatively small unit to be located near the charge to be measured while the much larger reed-driver and amplifier unit can be located wherever it is convenient for the operator.


Valve electrometers

Valve electrometers use a specialized
vacuum tube A vacuum tube, electron tube, valve (British usage), or tube (North America), is a device that controls electric current flow in a high vacuum between electrodes to which an electric potential difference has been applied. The type known as ...
(thermionic valve) with a very high
gain Gain or GAIN may refer to: Science and technology * Gain (electronics), an electronics and signal processing term * Antenna gain * Gain (laser), the amplification involved in laser emission * Gain (projection screens) * Information gain in de ...
(
transconductance Transconductance (for transfer conductance), also infrequently called mutual conductance, is the electrical characteristic relating the current through the output of a device to the voltage across the input of a device. Conductance is the reciproc ...
) and input resistance. The input current is allowed to flow into the high impedance grid, and the voltage so generated is vastly amplified in the
anode An anode is an electrode of a polarized electrical device through which conventional current enters the device. This contrasts with a cathode, an electrode of the device through which conventional current leaves the device. A common mnemonic is ...
( plate) circuit. Valves designed for electrometer use have leakage currents as low as a few femtoamperes (10−15 amperes). Such valves must be handled with gloved hands as the salts left on the glass envelope can provide leakage paths for these tiny currents. In a specialized circuit called ''inverted triode'', the roles of anode and grid are reversed. This places the control electrode at a maximum distance from the space-charge region surrounding the filament, minimizing the number of electrons collected by the control electrode, and thus minimizing the input current.


Solid-state electrometers

The most modern electrometers consist of a solid state
amplifier An amplifier, electronic amplifier or (informally) amp is an electronic device that can increase the magnitude of a signal (a time-varying voltage or current). It may increase the power significantly, or its main effect may be to boost t ...
using one or more
field-effect transistor The field-effect transistor (FET) is a type of transistor that uses an electric field to control the flow of current in a semiconductor. FETs (JFETs or MOSFETs) are devices with three terminals: ''source'', ''gate'', and ''drain''. FETs co ...
s, connections for external measurement devices, and usually a display and/or data-logging connections. The amplifier amplifies small currents so that they are more easily measured. The external connections are usually of a co-axial or tri-axial design, and allow attachment of
diode A diode is a two-terminal electronic component that conducts current primarily in one direction (asymmetric conductance); it has low (ideally zero) resistance in one direction, and high (ideally infinite) resistance in the other. A diod ...
s or
ionization chamber The ionization chamber is the simplest type of gas-filled radiation detector, and is widely used for the detection and measurement of certain types of ionizing radiation, including X-rays, gamma rays, and beta particles. Conventionally, the term ...
s for
ionising radiation Ionizing radiation (or ionising radiation), including nuclear radiation, consists of subatomic particles or electromagnetic waves that have sufficient energy to ionize atoms or molecules by detaching electrons from them. Some particles can t ...
measurement. The display or data-logging connections allow the user to see the data or record it for later analysis. Electrometers designed for use with ionization chambers may include a high-voltage power supply, which is used to bias the ionization chamber. Solid-state electrometers are often multipurpose devices that can measure voltage, charge, resistance and current. They measure voltage by means of "voltage balancing", in which the input voltage is compared with an internal reference voltage source using an electronic circuit with a very high input impedance (of the order of 1014 Ω). A similar circuit modified to act as a current-to-voltage converter enables the instrument to measure currents as small as a few femtoamperes. Combined with an internal voltage source, the current measuring mode can be adapted to measure very high resistances, of the order of 1017 Ω. Finally, by calculation from the known
capacitance Capacitance is the capability of a material object or device to store electric charge. It is measured by the change in charge in response to a difference in electric potential, expressed as the ratio of those quantities. Commonly recognized are ...
of the electrometer's input terminal, the instrument can measure very small
electric charge Electric charge is the physical property of matter that causes charged matter to experience a force when placed in an electromagnetic field. Electric charge can be ''positive'' or ''negative'' (commonly carried by protons and electrons res ...
s, down to a small fraction of a picocoulomb.


See also

* Electrical measurements *
Electron The electron ( or ) is a subatomic particle with a negative one elementary electric charge. Electrons belong to the first generation of the lepton particle family, and are generally thought to be elementary particles because they have n ...
*
Electroscope The electroscope is an early scientific instrument used to detect the presence of electric charge on a body. It detects charge by the movement of a test object due to the Coulomb electrostatic force on it. The amount of charge on an object is ...
*
Radiation In physics, radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium. This includes: * ''electromagnetic radiation'', such as radio waves, microwaves, infrared, visi ...
* Faraday cup electrometer


References

* Dr. J. Frick, ''Physical Technics; Or Practical Instructions for Making Experiments in Physics'' Translated By John D. Easter, Ph.D. - J. B. Lippincott & Co., Philadelphia 1862 * Robert Mfurgeson Ph.D. ''Electricity'' - William and Robert Chambers, London and Edinburgh 1866 * Silvanus P. Thompson, ''Elementary Lessons in electricity and Magnetism''. - Macmillan and Co. Limited, London 1905 * Jones, R. V., ''Instruments and Experiences'' - John Wiley and Sons, London 1988


External links

{{commons category, Electrometers
Build this FET electrometer
- A very simple circuit - 2 components
Simple FET electrometer
- A simple bridged circuit





from Multimedia Physics Studios Voltmeters Electrical meters Measuring instruments Electricity