Degaussing is the process of decreasing or eliminating a remnant
magnetic field A magnetic field is a vector field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular to its own velocity and to ...
. It is named after the gauss, a unit of
magnetism Magnetism is the class of physical attributes that are mediated by a magnetic field, which refers to the capacity to induce attractive and repulsive phenomena in other entities. Electric currents and the magnetic moments of elementary particles ...
, which in turn was named after
Carl Friedrich Gauss Johann Carl Friedrich Gauss (; german: Gauß ; la, Carolus Fridericus Gauss; 30 April 177723 February 1855) was a German mathematician and physicist who made significant contributions to many fields in mathematics and science. Sometimes refer ...
. Due to
magnetic hysteresis Magnetic hysteresis occurs when an external magnetic field is applied to a ferromagnet such as iron and the atomic dipoles align themselves with it. Even when the field is removed, part of the alignment will be retained: the material has become '' ...
, it is generally not possible to reduce a magnetic field completely to zero, so degaussing typically induces a very small "known" field referred to as bias. Degaussing was originally applied to reduce ships' magnetic signatures during
World War II World War II or the Second World War, often abbreviated as WWII or WW2, was a world war that lasted from 1939 to 1945. It involved the World War II by country, vast majority of the world's countries—including all of the great power ...
. Degaussing is also used to reduce magnetic fields in
cathode ray tube A cathode-ray tube (CRT) is a vacuum tube containing one or more electron guns, which emit electron beams that are manipulated to display images on a phosphorescent screen. The images may represent electrical waveforms ( oscilloscope), ...
monitor Monitor or monitor may refer to: Places * Monitor, Alberta * Monitor, Indiana, town in the United States * Monitor, Kentucky * Monitor, Oregon, unincorporated community in the United States * Monitor, Washington * Monitor, Logan County, West ...
s and to destroy data held on magnetic storage.


Ships' hulls

The term was first used by then-Commander
Charles F. Goodeve Sir Charles Frederick Goodeve (21 February 1904 – 7 April 1980) was a Canadian chemist and pioneer in operations research. During World War II, he was instrumental in developing the "hedgehog" antisubmarine warfare weapon and the degaussing me ...
,
Royal Canadian Naval Volunteer Reserve The Royal Canadian Navy Volunteer Reserve (RCNVR) was a naval reserve force of the Royal Canadian Navy, which replaced the Royal Navy Canadian Volunteer Reserve (RNCVR). Foundation The RCNVR was created in 1923. The organization was established ...
, during World War II while trying to counter the German magnetic
naval mine A naval mine is a self-contained explosive device placed in water to damage or destroy surface ships or submarines. Unlike depth charges, mines are deposited and left to wait until they are triggered by the approach of, or contact with, an ...
s that were wreaking havoc on the
British fleet The Royal Navy (RN) is the United Kingdom's naval warfare force. Although warships were used by English and Scottish kings from the early medieval period, the first major maritime engagements were fought in the Hundred Years' War against Fr ...
. The mines detected the increase in the magnetic field when the steel in a ship concentrated the
Earth's magnetic field Earth's magnetic field, also known as the geomagnetic field, is the magnetic field that extends from Earth's interior out into space, where it interacts with the solar wind, a stream of charged particles emanating from the Sun. The magneti ...
over it. Admiralty scientists, including Goodeve, developed a number of systems to induce a small "N-pole up" field into the ship to offset this effect, meaning that the net field was the same as the background. Since the Germans used the gauss as the unit of the strength of the magnetic field in their mines' triggers (not yet a standard measure), Goodeve referred to the various processes to counter the mines as "degaussing". The term became a common word. The original method of degaussing was to install electromagnetic coils into the ships, known as ''coiling.'' In addition to being able to bias the ship continually, coiling also allowed the bias field to be reversed in the southern hemisphere, where the mines were set to detect "S-pole down" fields. British ships, notably
cruiser A cruiser is a type of warship. Modern cruisers are generally the largest ships in a fleet after aircraft carriers and amphibious assault ships, and can usually perform several roles. The term "cruiser", which has been in use for several ...
s and
battleship A battleship is a large armour, armored warship with a main artillery battery, battery consisting of large caliber guns. It dominated naval warfare in the late 19th and early 20th centuries. The term ''battleship'' came into use in the late 1 ...
s, were well protected by about 1943. Installing such special equipment was, however, far too expensive and difficult to service all ships that would need it, so the navy developed an alternative called ''wiping,'' which Goodeve also devised, and which is now also called ''deperming''. This procedure dragged a large electrical cable along the side of the ship with a pulse of about 2000
ampere The ampere (, ; symbol: A), often shortened to amp,SI supports only the use of symbols and deprecates the use of abbreviations for units. is the unit of electric current in the International System of Units (SI). One ampere is equal to elect ...
s flowing through it. This induced the proper field into the ship in the form of a slight bias. It was originally thought that the pounding of the sea and the ship's engines would slowly randomize this field, but in testing, this was found not to be a real problem. A more serious problem was later realized: as a ship travels through Earth's magnetic field, it will slowly pick up that field, counteracting the effects of the degaussing. From then on captains were instructed to change direction as often as possible to avoid this problem. Nevertheless, the bias did wear off eventually, and ships had to be degaussed on a schedule. Smaller ships continued to use wiping through the war. To aid the
Dunkirk evacuation The Dunkirk evacuation, codenamed Operation Dynamo and also known as the Miracle of Dunkirk, or just Dunkirk, was the evacuation of more than 338,000 Allies of World War II, Allied soldiers during the World War II, Second World War from the bea ...
, the British "wiped" 400 ships in four days. During World War II, the
United States Navy The United States Navy (USN) is the maritime service branch of the United States Armed Forces and one of the eight uniformed services of the United States. It is the largest and most powerful navy in the world, with the estimated tonnage ...
commissioned a specialized class of degaussing ships that were capable of performing this function. One of them, USS ''Deperm'' (ADG-10), was named after the procedure. After the war, the capabilities of the magnetic fuzes were greatly improved, by detecting not the field itself, but changes in it. This meant a degaussed ship with a magnetic "hot spot" would still set off the mine. Additionally, the precise orientation of the field was also measured, something a simple bias field could not remove, at least for all points on the ship. A series of ever-increasingly complex coils were introduced to offset these effects, with modern systems including no fewer than three separate sets of coils to reduce the field in all axes.


High-temperature superconductivity

The US Navy tested, in April 2009, a prototype of its
High-Temperature Superconducting High-temperature superconductors (abbreviated high-c or HTS) are defined as materials that behave as superconductors at temperatures above , the boiling point of liquid nitrogen. The adjective "high temperature" is only in respect to previou ...
Degaussing Coil System, referred to as "HTS Degaussing". The system works by encircling the vessel with superconducting ceramic cables whose purpose is to neutralize the ship's magnetic signature, as in the legacy copper systems. The main advantage of the HTS Degaussing Coil system is greatly reduced weight (sometimes by as much as 80%) and increased efficiency. A sea-going metal-hulled ship or submarine, by its very nature, develops a magnetic signature as it travels, due to a magneto-mechanical interaction with Earth's magnetic field. It also picks up the magnetic orientation of the Earth's magnetic field where it is built. This signature can be exploited by magnetic mines or facilitate the detection of a submarine by ships or aircraft with magnetic anomaly detection (MAD) equipment. Navies use the deperming procedure, in conjunction with degaussing, as a countermeasure against this. Specialized deperming facilities, such as the
United States Navy The United States Navy (USN) is the maritime service branch of the United States Armed Forces and one of the eight uniformed services of the United States. It is the largest and most powerful navy in the world, with the estimated tonnage ...
's Lambert's Point Deperming Station at
Naval Station Norfolk Naval Station Norfolk is a United States Navy base in Norfolk, Virginia, that is the headquarters and home port of the U.S. Navy's Fleet Forces Command. The installation occupies about of waterfront space and of pier and wharf space of the Hampt ...
, or Pacific Fleet Submarine Drive-In Magnetic Silencing Facility (MSF) at
Joint Base Pearl Harbor–Hickam Joint Base Pearl Harbor–Hickam (JBPHH) is a United States military base on the island of Oahu, Hawaii. It is an amalgamation of the United States Air Force's Hickam Air Force Base and the United States Navy's Naval Station Pearl Harbor, ...
, are used to perform the procedure. During a closed-wrap magnetic treatment, heavy-gauge
copper Copper is a chemical element with the symbol Cu (from la, cuprum) and atomic number 29. It is a soft, malleable, and ductile metal with very high thermal and electrical conductivity. A freshly exposed surface of pure copper has a pink ...
cables encircle the hull and superstructure of the vessel, and high electrical currents (up to 4000
ampere The ampere (, ; symbol: A), often shortened to amp,SI supports only the use of symbols and deprecates the use of abbreviations for units. is the unit of electric current in the International System of Units (SI). One ampere is equal to elect ...
s) are pulsed through the cables. This has the effect of "resetting" the ship's magnetic signature to the ambient level after flashing its hull with electricity. It is also possible to assign a specific signature that is best suited to the particular area of the world in which the ship will operate. In drive-in magnetic silencing facilities, all cables are either hung above, below and on the sides, or concealed within the structural elements of facilities. Deperming is "permanent". It is only done once unless major repairs or structural modifications are done to the ship.


Early experiments

With the introduction of
iron Iron () is a chemical element with symbol Fe (from la, ferrum) and atomic number 26. It is a metal that belongs to the first transition series and group 8 of the periodic table. It is, by mass, the most common element on Earth, right in ...
ships, the negative effect of the metal hull on steering
compass A compass is a device that shows the cardinal directions used for navigation and geographic orientation. It commonly consists of a magnetized needle or other element, such as a compass card or compass rose, which can pivot to align itself with ...
es was noted. It was also observed that
lightning Lightning is a naturally occurring electrostatic discharge during which two electrically charged regions, both in the atmosphere or with one on the ground, temporarily neutralize themselves, causing the instantaneous release of an average ...
strikes had a significant effect on compass deviation, identified in some extreme cases as being caused by the reversal of the ship's magnetic signature. In 1866, Evan Hopkins of London registered a patent for a process "to depolarise iron vessels and leave them thenceforth free from any compass-disturbing influence whatever". The technique was described as follows: "For this purpose he employed a number of Grove's batteries and electromagnets. The latter were to be passed along the plates till the desired end had been obtained... the process must not be overdone for fear of re-polarising in the opposite direction." The invention was, however, reported to be "incapable of being carried to a successful issue", and "quickly died a natural death".


Color cathode ray tubes

Color CRT displays, the technology underlying many television and
computer monitors A computer monitor is an output device that displays information in pictorial or textual form. A discrete monitor comprises a visual display, support electronics, power supply, housing, electrical connectors, and external user controls. The d ...
before the early 2010s, use degaussing. Many CRT displays use a
metal A metal (from ancient Greek, Greek μέταλλον ''métallon'', "mine, quarry, metal") is a material that, when freshly prepared, polished, or fractured, shows a lustrous appearance, and conducts electrical resistivity and conductivity, e ...
plate near the front of the tube to ensure that each electron beam hits the corresponding phosphors of the correct color. If this plate becomes magnetized (e.g. if someone sweeps a magnet on the screen or places loudspeakers nearby), it imparts an undesired deflection to the electron beams and the displayed image becomes distorted and discolored. To minimize this, CRTs have a copper, or often in the case of cheaper appliances, aluminum, coil wrapped around the front of the display, known as the degaussing coil. Monitors without an internal coil can be degaussed using an external handheld version. Internal degaussing coils in CRTs are generally much weaker than external degaussing coils, since a better degaussing coil takes up more space. A degauss causes a
magnetic field A magnetic field is a vector field that describes the magnetic influence on moving electric charges, electric currents, and magnetic materials. A moving charge in a magnetic field experiences a force perpendicular to its own velocity and to ...
inside the tube to oscillate rapidly, with decreasing
amplitude The amplitude of a periodic variable is a measure of its change in a single period (such as time or spatial period). The amplitude of a non-periodic signal is its magnitude compared with a reference value. There are various definitions of am ...
. This leaves the shadow mask with a field opposing any external field (such as that of the Earth), removing the discoloration. Many televisions and monitors automatically degauss their picture tube when switched on, before an image is displayed. The high current surge that takes place during this automatic degauss is the cause of an audible "thunk", a loud hum or some clicking noises, which can be heard (and felt) when televisions and CRT computer monitors are switched on, due to the capacitors discharging and injecting current into the coil. Visually, this causes the image to shake dramatically for a short period of time. A degauss option is also usually available for manual selection in the operations menu in such appliances. In most commercial equipment the current surge to the degaussing coil is regulated by a simple positive temperature coefficient (PTC)
thermistor A thermistor is a type of resistor whose resistance is strongly dependent on temperature, more so than in standard resistors. The word thermistor is a portmanteau of ''thermal'' and ''resistor''. Thermistors are divided based on their conduction ...
device, which initially has a low resistance but quickly changes to a high resistance due to the heating effect of the current flow. Such devices are designed for a one-off transition from cold to hot at power up; "experimenting" with the degauss effect by repeatedly switching the device on and off may cause this component to fail. The effect will also be weaker, since the PTC will not have had time to cool off.


Magnetic data storage media

Data is stored in the
magnetic media Magnetic storage or magnetic recording is the storage of data on a magnetized medium. Magnetic storage uses different patterns of magnetisation in a magnetizable material to store data and is a form of non-volatile memory. The information is ac ...
, such as
hard drive A hard disk drive (HDD), hard disk, hard drive, or fixed disk is an electro-mechanical data storage device that stores and retrieves digital data using magnetic storage with one or more rigid rapidly rotating platters coated with mag ...
s,
floppy disk A floppy disk or floppy diskette (casually referred to as a floppy, or a diskette) is an obsolescent type of disk storage composed of a thin and flexible disk of a magnetic storage medium in a square or nearly square plastic enclosure lined ...
s, and
magnetic tape Magnetic tape is a medium for magnetic storage made of a thin, magnetizable coating on a long, narrow strip of plastic film. It was developed in Germany in 1928, based on the earlier magnetic wire recording from Denmark. Devices that use magnet ...
, by making very small areas called
magnetic domain A magnetic domain is a region within a magnetic material in which the magnetization is in a uniform direction. This means that the individual magnetic moments of the atoms are aligned with one another and they point in the same direction. When c ...
s, change their magnetic alignment to be in the direction of an applied magnetic field. This phenomenon occurs in much the same way a compass needle points in the direction of the Earth's magnetic field. Degaussing, commonly called erasure, leaves the domains in random patterns with no preference to orientation, thereby rendering previous data unrecoverable. There are some domains whose magnetic alignment is not randomized after degaussing. The information these domains represent is commonly called magnetic
remanence Remanence or remanent magnetization or residual magnetism is the magnetization left behind in a ferromagnetic material (such as iron) after an external magnetic field is removed. Colloquially, when a magnet is "magnetized", it has remanence. The ...
or
remanent magnetization Remanence or remanent magnetization or residual magnetism is the magnetization left behind in a ferromagnetic material (such as iron) after an external magnetic field is removed. Colloquially, when a magnet is "magnetized", it has remanence. The ...
. Proper degaussing will ensure there is insufficient magnetic remanence to reconstruct the data. Erasure via degaussing may be accomplished in two ways: in AC erasure, the medium is degaussed by applying an alternating field that is reduced in amplitude over time from an initial high value (i.e., AC powered); in DC erasure, the medium is saturated by applying a unidirectional field (i.e., DC powered or by employing a
permanent magnet A magnet is a material or object that produces a magnetic field. This magnetic field is invisible but is responsible for the most notable property of a magnet: a force that pulls on other ferromagnetic materials, such as iron, steel, nickel ...
). A ''degausser'' is a device that can generate a magnetic field for degaussing magnetic storage media. The magnetic field needed for degaussing magnetic data storage media is a powerful one that normal magnets cannot easily achieve and maintain.


Irreversible damage to some media types

Many forms of generic magnetic storage media can be reused after degaussing, including reel-to-reel audio tape, VHS videocassettes, and
floppy disk A floppy disk or floppy diskette (casually referred to as a floppy, or a diskette) is an obsolescent type of disk storage composed of a thin and flexible disk of a magnetic storage medium in a square or nearly square plastic enclosure lined ...
s. These older media types are simply a raw medium which are overwritten with fresh new patterns, created by fixed-alignment read/write heads. For certain forms of computer data storage, however, such as modern
hard disk drive A hard disk drive (HDD), hard disk, hard drive, or fixed disk is an electro-mechanical data storage device that stores and retrieves digital data using magnetic storage with one or more rigid rapidly rotating platters coated with mag ...
s and some
tape drive A tape drive is a data storage device that reads and writes data on a magnetic tape. Magnetic tape data storage is typically used for offline, archival data storage. Tape media generally has a favorable unit cost and a long archival stability. ...
s, degaussing renders the magnetic media completely unusable and damages the storage system. This is due to the devices having an infinitely variable read/write head positioning mechanism which relies on special servo control data (e.g.
Gray Code The reflected binary code (RBC), also known as reflected binary (RB) or Gray code after Frank Gray, is an ordering of the binary numeral system such that two successive values differ in only one bit (binary digit). For example, the representa ...
) that is meant to be permanently recorded onto the magnetic media. This servo data is written onto the media a single time at the factory using special-purpose servo writing hardware. The servo patterns are normally never overwritten by the device for any reason and are used to precisely position the read/write heads over data tracks on the media, to compensate for sudden jarring device movements, thermal expansion, or changes in orientation. Degaussing indiscriminately removes not only the stored data but also the servo control data, and without the servo data the device is no longer able to determine where data is to be read or written on the magnetic medium. The servo data must be rewritten to become usable again; with modern hard drives, this is generally not possible without manufacturer-specific and often model-specific service equipment.


Audio tape recorders

In
reel-to-reel Reel-to-reel audio tape recording, also called open-reel recording, is magnetic tape audio recording in which the recording tape is spooled between reels. To prepare for use, the ''supply reel'' (or ''feed reel'') containing the tape is pla ...
and
compact cassette The Compact Cassette or Musicassette (MC), also commonly called the tape cassette, cassette tape, audio cassette, or simply tape or cassette, is an analog magnetic tape recording format for audio recording and playback. Invented by Lou Otte ...
audio tape recorders, remnant magnetic fields will over time gather on metal parts such as guide posts tape heads. These are points that come into contact with the magnetic tape. The remnant fields can cause an increase in audible background noise during playback. Cheap, handheld consumer degaussers can significantly reduce this effect.


Types of degaussers

Degaussers range in size from small ones used in offices for erasing magnetic data storage devices to industrial-size degaussers for use on piping, ships, submarines, and other large-sized items, equipment to vehicles. Rating and categorizing degaussers depends on the strength of the magnetic field the degausser generates, the method of generating a magnetic field in the degausser, the type of operations the degausser is suitable for, the working rate of the degausser based on whether it is a high volume degausser or a low volume degausser, and mobility of the degausser among others. From these criteria of rating and categorization, there are thus electromagnetic degaussers, permanent magnet degaussers as the main types of degaussers.


Electromagnetic degaussers

An electromagnetic degausser passes an electrical charge through a degaussing coil to generate a magnetic field. Sub-types of electromagnetic degaussers are several such as Rotating Coil Degaussers and Pulse Demagnetization Technology degaussers since the technologies used in the degaussers are often developed and patented by respective manufacturing companies such as Verity Systems and Maurer Magnetic among others, so that the degausser is suitable for its intended use. Electromagnetic degaussers generate strong magnetic fields, and have a high rate of work.


Rotating coil degausser

Performance of a degaussing machine is the major determinant of the effectiveness of degaussing magnetic data storage media. Effectiveness does not improve when the media passes through the same degaussing magnetic field more than once. Rotating the media by 90 degrees improves effectiveness of degaussing the media. One magnetic media degaussers’ manufacturer, Verity Systems, has used this principle in a rotating coil technique they developed. Their rotating coil degausser passes the magnetic data storage media being erased through a magnetic field generated using two coils in the degaussing machine with the media on a variable-speed conveyor belt. The two coils generating a magnetic field are rotating; with one coil positioned above the media and the other coil positioned below the media.


Pulse degaussing

Pulse degaussing technology involves the cyclic application of electric current for a fraction of a second to the coil being used to generate a magnetic field in the degausser. The process starts with the maximum voltage applied and held for only a fraction of a second to avoid overheating the coil, and then the voltages applied in subsequent seconds are reduced in sequence at varying differences until no current is applied to the coil. Pulse degaussing saves on energy costs, produces high magnetic field strength, is suitable for degaussing large assemblies, and is reliable due to zero-error degaussing achievement.


Permanent magnet degausser

Permanent magnet degaussers use magnets made using rare earth materials. They do not require electricity for their operation. Permanent magnet degaussers require adequate shielding of the magnetic field they constantly have to prevent unintended degaussing. The need for shielding usually results in permanent magnet degaussers being bulky. When small-sized, permanent magnet degaussers are suited for use as mobile degaussers.


See also

* Data remanence


References


External links


Guide to degaussing TVs
* *{{cite web , title=A Guide to Understanding Data Remanence in Automated Information Systems , url=http://www.cerberussystems.com/INFOSEC/stds/ncsctg25.htm , website=www.cerberussystems.com , archive-url=https://web.archive.org/web/20160304103802/http://www.cerberussystems.com/INFOSEC/stds/ncsctg25.htm , archive-date=2016-03-04 , url-status=dead *https://degaussing-101.com/what-is-degaussing/ Computer storage media Magnetic hysteresis British inventions