HOME

TheInfoList



OR:

The term contact resistance refers to the contribution to the total resistance of a system which can be attributed to the contacting interfaces of electrical leads and connections as opposed to the intrinsic resistance. This effect is described by the term electrical contact resistance (ECR) and arises as the result of the limited areas of true contact at an interface and the presence of resistive surface films or oxide layers. ECR may vary with time, most often decreasing, in a process known as resistance creep. The idea of potential drop on the injection electrode was introduced by
William Shockley William Bradford Shockley Jr. (February 13, 1910 – August 12, 1989) was an American physicist and inventor. He was the manager of a research group at Bell Labs that included John Bardeen and Walter Brattain. The three scientists were jointl ...
to explain the difference between the experimental results and the model of gradual channel approximation. In addition to the term ECR, ''interface resistance'', ''transitional resistance'', or just simply ''correction term'' are also used. The term ''parasitic resistance'' is used as a more general term, of which it is usually assumed that contact resistance is a major component.


Experimental characterization

Here we need to distinguish the contact resistance evaluation in two-electrode systems (e.g. diodes) and three-electrode systems (e.g. transistors). For two electrode systems the specific contact resistivity is experimentally defined as the slope of the
I-V curve IV may refer to: Businesses and organizations *Immigration Voice, an activist organization *Industrievereinigung, Federation of Austrian Industry * Intellectual Ventures, a privately held intellectual property company * InterVarsity Christian Fel ...
at : :r_c = \left\_ where J is the current density, or current per area. The units of specific contact resistivity are typically therefore in ohms-square meter, or \Omega \cdot \text^2. When the current is a linear function of the voltage, the device is said to have ohmic contacts. The resistance of contacts can be crudely estimated by comparing the results of a four terminal measurement to a simple two-lead measurement made with an ohmmeter. In a two-lead experiment, the measurement current causes a potential drop across both the test leads and the contacts so that the resistance of these elements is inseparable from the resistance of the actual device, with which they are in series. In a four-point probe measurement, one pair of leads is used to inject the measurement current while a second pair of leads, in parallel with the first, is used to measure the potential drop across the device. In the four-probe case, there is no potential drop across the voltage measurement leads so the contact resistance drop is not included. The difference between resistance derived from two-lead and four-lead methods is a reasonably accurate measurement of contact resistance assuming that the leads resistance is much smaller. Specific contact resistance can be obtained by multiplying by contact area. Contact resistance may vary with temperature. Inductive and capacitive methods could be used in principle to measure an intrinsic impedance without the complication of contact resistance. In practice,
direct current Direct current (DC) is one-directional flow of electric charge. An electrochemical cell is a prime example of DC power. Direct current may flow through a conductor such as a wire, but can also flow through semiconductors, insulators, or ev ...
methods are more typically used to determine resistance. The three electrode systems such as transistors require more complicated methods for the contact resistance approximation. The most common approach is the transmission line model (TLM). Here, the total device resistance R_\text is plotted as a function of the channel length: :R_\text = R_\text + R_\text = R_\text + \frac where R_\text and R_\text are contact and channel resistances, respectively, L/W is the channel length/width, C is gate insulator capacitance (per unit of area), \mu is carrier mobility, and V_\text and V_\text are gate-source and drain-source voltages. Therefore, the linear extrapolation of total resistance to the zero channel length provides the contact resistance. The slope of the linear function is related to the channel transconductance and can be used for estimation of the ”contact resistance-free” carrier mobility. The approximations used here (linear potential drop across the channel region, constant contact resistance, …) lead sometimes to the channel dependent contact resistance. Beside the TLM it was proposed the gated four-probe measurement and the modified
time-of-flight Time of flight (ToF) is the measurement of the time taken by an object, particle or wave (be it acoustic, electromagnetic, etc.) to travel a distance through a medium. This information can then be used to measure velocity or path length, or as a w ...
method (TOF). The direct methods able to measure potential drop on the injection electrode directly are the Kelvin probe force microscopy (KFM) and the electric-field induced second harmonic generation. In the semiconductor industry, Cross-Bridge Kelvin Resistor(CBKR) structures are the mostly used test structures to characterize metal-semiconductor contacts in the Planar devices of VLSI technology. During the measurement process, force the current (I) between contact 1&2 and measure the potential deference between contacts 3&4. The contact resistance Rk can be then calculated as Rk=V34/I .


Mechanisms

For given physical and mechanical material properties, parameters that govern the magnitude of electrical contact resistance (ECR) and its variation at an interface relate primarily to surface structure and applied load (
Contact mechanics Contact mechanics is the study of the deformation of solids that touch each other at one or more points.Johnson, K. L, 1985, Contact mechanics, Cambridge University Press.Popov, Valentin L., 2010, ''Contact Mechanics and Friction. Physical P ...
). Surfaces of metallic contacts generally exhibit an external layer of oxide material and adsorbed water molecules, which lead to capacitor-type junctions at weakly contacting asperities and resistor type contacts at strongly contacting asperities, where sufficient pressure is applied for asperities to penetrate the oxide layer, forming metal-to-metal contact patches. If a contact patch is sufficiently small, with dimensions comparable or smaller than the
mean free path In physics, mean free path is the average distance over which a moving particle (such as an atom, a molecule, or a photon) travels before substantially changing its direction or energy (or, in a specific context, other properties), typically as ...
of electrons resistance at the patch can be described by the Sharvin mechanism, whereby electron transport can be described by
ballistic conduction In mesoscopic physics, ballistic conduction (ballistic transport) is the unimpeded flow (or transport) of charge carriers (usually electrons), or energy-carrying particles, over relatively long distances in a material. In general, the resistivity ...
. Generally, over time, contact patches expand and the contact resistance at an interface relaxes, particularly at weakly contacting surfaces, through current induced welding and dielectric breakdown. This process is known also as resistance creep. The coupling of
surface chemistry Surface science is the study of physical and chemical phenomena that occur at the interface of two phases, including solid–liquid interfaces, solid– gas interfaces, solid–vacuum interfaces, and liquid– gas interfaces. It includes the fi ...
, contact mechanics and charge transport mechanisms needs to be considered in the mechanistic evaluation of ECR phenomena.


Quantum limit

When a conductor has spatial dimensions close to 2\pi/k_\text, where k_\text is Fermi wavevector of the conducting material,
Ohm's law Ohm's law states that the current through a conductor between two points is directly proportional to the voltage across the two points. Introducing the constant of proportionality, the resistance, one arrives at the usual mathematical equa ...
does not hold anymore. These small devices are called quantum point contacts. Their conductance must be an integer multiple of the value 2e^2/h, where e is the
elementary charge The elementary charge, usually denoted by is the electric charge carried by a single proton or, equivalently, the magnitude of the negative electric charge carried by a single electron, which has charge −1 . This elementary charge is a fundam ...
and h is Planck's constant. Quantum point contacts behave more like
waveguide A waveguide is a structure that guides waves, such as electromagnetic waves or sound, with minimal loss of energy by restricting the transmission of energy to one direction. Without the physical constraint of a waveguide, wave intensities de ...
s than the classical wires of everyday life and may be described by the Landauer scattering formalism. Point-contact tunneling is an important technique for characterizing superconductors.


Other forms of contact resistance

Measurements of
thermal conductivity The thermal conductivity of a material is a measure of its ability to conduct heat. It is commonly denoted by k, \lambda, or \kappa. Heat transfer occurs at a lower rate in materials of low thermal conductivity than in materials of high thermal ...
are also subject to contact resistance, with particular significance in heat transport through granular media. Similarly, a drop in
hydrostatic pressure Fluid statics or hydrostatics is the branch of fluid mechanics that studies the condition of the equilibrium of a floating body and submerged body " fluids at hydrostatic equilibrium and the pressure in a fluid, or exerted by a fluid, on an i ...
(analogous to electrical
voltage Voltage, also known as electric pressure, electric tension, or (electric) potential difference, is the difference in electric potential between two points. In a static electric field, it corresponds to the work needed per unit of charge to ...
) occurs when
fluid flow In physics and engineering, fluid dynamics is a subdiscipline of fluid mechanics that describes the flow of fluids—liquids and gases. It has several subdisciplines, including ''aerodynamics'' (the study of air and other gases in motion) an ...
transitions from one channel to another.


Significance

Bad contacts are the cause of failure or poor performance in a wide variety of electrical devices. For example, corroded jumper cable clamps can frustrate attempts to start a
vehicle A vehicle (from la, vehiculum) is a machine that transports people or cargo. Vehicles include wagons, bicycles, motor vehicles (motorcycles, cars, trucks, buses, mobility scooters for disabled people), railed vehicles (trains, trams), ...
that has a low
battery Battery most often refers to: * Electric battery, a device that provides electrical power * Battery (crime), a crime involving unlawful physical contact Battery may also refer to: Energy source *Automotive battery, a device to provide power t ...
. Dirty or
corroded Corroded is a heavy metal band from Ånge, Sweden. The band is best known for their song ''Time And Again'', which was the theme song for the Swedish 2009 ''Survivor'' television series on TV4. The band's second album ''Exit to Transfer'', re ...
contacts on a
fuse Fuse or FUSE may refer to: Devices * Fuse (electrical), a device used in electrical systems to protect against excessive current ** Fuse (automotive), a class of fuses for vehicles * Fuse (hydraulic), a device used in hydraulic systems to protect ...
or its holder can give the false impression that the fuse is blown. A sufficiently high contact resistance can cause substantial
heating A central heating system provides warmth to a number of spaces within a building from one main source of heat. It is a component of heating, ventilation, and air conditioning (short: HVAC) systems, which can both cool and warm interior spaces. ...
in a high current device. Unpredictable or noisy contacts are a major cause of the failure of electrical equipment.


See also

* Contact cleaner *
Wetting current In electrical and electronics engineering, wetting current is the minimum electric current needing to flow through a contact to break through the surface film resistance at a contact. It is typically far below the contact's nominal maximum curr ...


References


Further reading

* (NB. Free download after registration.) * * (NB. A rewrite of the earlier "''Electric Contacts Handbook''".) *
https://web.archive.org/web/20180520151548/http://www.gbv.de/dms/ilmenau/toc/176968075.PDF -->
(NB. A rewrite and translation of the earlier "''Die technische Physik der elektrischen Kontakte''" (1941) in German language, which is available as reprint under .) * {{cite book , editor-first1=Eduard , editor-last1=Vinaricky , editor-first2=Karl-Heinz , editor-last2=Schröder , editor-first3=Josef , editor-last3=Weiser , editor-first4=Albert , editor-last4=Keil , editor-first5=Wilhelm A. , editor-last5=Merl , editor-first6=Carl-Ludwig , editor-last6=Meyer , author-first1=Manfred , author-last1=Huck , author-first2=Eugeniucz , author-last2=Walczuk , author-first3=Isabell , author-last3=Buresch , author-first4=Josef , author-last4=Weiser , author-first5=Lothar , author-last5=Borchert , author-first6=Manfred , author-last6=Faber , author-first7=Willy , author-last7=Bahrs , author-first8=Karl E. , author-last8=Saeger , author-first9=Reinhard , author-last9=Imm , author-first10=Volker , author-last10=Behrens , author-first11=Jochen , author-last11=Heber , author-first12=Hermann , author-last12=Großmann , author-first13=Max , author-last13=Streuli , author-first14=Peter , author-last14=Schuler , author-first15=Helmut , author-last15=Heinzel , author-first16=Ulf , author-last16=Harmsen , author-first17=Imre , author-last17=Györy , author-first18=Joachim , author-last18=Ganz , author-first19=Jochen , author-last19=Horn , author-first20=Franz , author-last20=Kaspar , author-first21=Manfred , author-last21=Lindmayer , author-first22=Frank , author-last22=Berger , author-first23=Guenter , author-last23=Baujan , author-first24=Ralph , author-last24=Kriechel , author-first25=Johann , author-last25=Wolf , author-first26=Günter , author-last26=Schreiner , author-first27=Gerhard , author-last27=Schröther , author-first28=Uwe , author-last28=Maute , author-first29=Hartmut , author-last29=Linnemann , author-first30=Ralph , author-last30=Thar , author-first31=Wolfgang , author-last31=Möller , author-first32=Werner , author-last32=Rieder , author-first33=Jan , author-last33=Kaminski , author-first34=Heinz-Erich , author-last34=Popa , author-first35=Karl-Heinz , author-last35=Schneider , author-first36=Jakob , author-last36=Bolz , author-first37=L. , author-last37=Vermij , author-first38=Ursula , author-last38=Mayer , title=Elektrische Kontakte, Werkstoffe und Anwendungen: Grundlagen, Technologien, Prüfverfahren , language=German , edition=3 , location=Berlin / Heidelberg / New York / Tokyo , publisher=
Springer-Verlag Springer Science+Business Media, commonly known as Springer, is a German multinational publishing company of books, e-books and peer-reviewed journals in science, humanities, technical and medical (STM) publishing. Originally founded in 1842 ...
, date=2016 , orig-year=1984 , isbn=978-3-642-45426-4 Materials science Electrical resistance and conductance