chloridometer
   HOME

TheInfoList



OR:

A chloridometer is a
measuring instrument A measuring instrument is a device to measure a physical quantity. In the physical sciences, quality assurance, and engineering, measurement is the activity of obtaining and comparing physical quantities of real-world objects and events. Est ...
used to determine the
concentration In chemistry, concentration is the abundance of a constituent divided by the total volume of a mixture. Several types of mathematical description can be distinguished: '' mass concentration'', '' molar concentration'', ''number concentration'', ...
of
chloride The chloride ion is the anion (negatively charged ion) Cl−. It is formed when the element chlorine (a halogen) gains an electron or when a compound such as hydrogen chloride is dissolved in water or other polar solvents. Chloride s ...
ions (Cl) in a
solution Solution may refer to: * Solution (chemistry), a mixture where one substance is dissolved in another * Solution (equation), in mathematics ** Numerical solution, in numerical analysis, approximate solutions within specified error bounds * Solutio ...
. It uses a process known as coulometric titration or ''amperostatic coulometry'', the accepted
electrochemistry Electrochemistry is the branch of physical chemistry concerned with the relationship between electrical potential difference, as a measurable and quantitative phenomenon, and identifiable chemical change, with the potential difference as an out ...
reference method to determine the concentration of chloride in biological fluids, including
blood serum Serum () is the fluid and solute component of blood which does not play a role in clotting. It may be defined as blood plasma without the clotting factors, or as blood with all cells and clotting factors removed. Serum includes all proteins not ...
,
blood plasma Blood plasma is a light amber-colored liquid component of blood in which blood cells are absent, but contains proteins and other constituents of whole blood in suspension. It makes up about 55% of the body's total blood volume. It is the int ...
,
urine Urine is a liquid by-product of metabolism in humans and in many other animals. Urine flows from the kidneys through the ureters to the urinary bladder. Urination results in urine being excreted from the body through the urethra. Cellul ...
,
sweat Perspiration, also known as sweating, is the production of fluids secreted by the sweat glands in the skin of mammals. Two types of sweat glands can be found in humans: eccrine glands and apocrine glands. The eccrine sweat glands are distrib ...
, and
cerebrospinal fluid Cerebrospinal fluid (CSF) is a clear, colorless body fluid found within the tissue that surrounds the brain and spinal cord of all vertebrates. CSF is produced by specialised ependymal cells in the choroid plexus of the ventricles of the ...
. The
coulometry Coulometry determines the amount of matter transformed during an electrolysis reaction by measuring the amount of electricity (in coulombs) consumed or produced. It can be used for precision measurements of charge, and the amperes even used to have ...
process generates
silver Silver is a chemical element with the symbol Ag (from the Latin ', derived from the Proto-Indo-European ''h₂erǵ'': "shiny" or "white") and atomic number 47. A soft, white, lustrous transition metal, it exhibits the highest electrical ...
ions, which react with the chloride to form
silver chloride Silver chloride is a chemical compound with the chemical formula Ag Cl. This white crystalline solid is well known for its low solubility in water (this behavior being reminiscent of the chlorides of Tl+ and Pb2+). Upon illumination or heat ...
(AgCl). The first chloridometer was designed by a team led by Ernest Cotlove in 1958. Other methods to determine chloride concentration include photometric titration and
isotope dilution Isotope dilution analysis is a method of determining the quantity of chemical substances. In its most simple conception, the method of isotope dilution comprises the addition of known amounts of isotopically enriched substance to the analyzed samp ...
mass spectrometry.


Operation

An amperostat delivers a constant
current Currents, Current or The Current may refer to: Science and technology * Current (fluid), the flow of a liquid or a gas ** Air current, a flow of air ** Ocean current, a current in the ocean *** Rip current, a kind of water current ** Current (stre ...
of about 6—8  mA to the generator
electrode An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials ...
s for the titration of the solution, and a digital timer is started. A second pair of silver electrodes are used as a detector to measure the conductance of the solution. The same constant current is known to titrate a given number of
moles Moles can refer to: * Moles de Xert, a mountain range in the Baix Maestrat comarca, Valencian Community, Spain *The Moles (Australian band) *The Moles, alter ego of Scottish band Simon Dupree and the Big Sound People * Abraham Moles, French engin ...
(n_)_s of a chloride standard solution in time t_s. Titration of the
assay An assay is an investigative (analytic) procedure in laboratory medicine, mining, pharmacology, environmental biology and molecular biology for qualitatively assessing or quantitatively measuring the presence, amount, or functional activity of ...
solution will result in the generation of
insoluble In chemistry, solubility is the ability of a substance, the solute, to form a solution with another substance, the solvent. Insolubility is the opposite property, the inability of the solute to form such a solution. The extent of the solubi ...
silver chloride until the chloride ions are consumed, after which time an increase in silver ions will be detected at the detector electrodes. This time, t_u, is the titration time of the solution being measured. The concentration of chloride ions in this solution is then calculated as: :(n_)_u = \times (n_)_s Although the absolute quantity of silver ions (Ag^+) required to react with the chloride ions can be determined using Faraday's laws of electrolysis, in practice calibration is required. Silver ions are generated by
oxidation Redox (reduction–oxidation, , ) is a type of chemical reaction in which the oxidation states of substrate change. Oxidation is the loss of electrons or an increase in the oxidation state, while reduction is the gain of electrons or ...
at the
anode An anode is an electrode of a polarized electrical device through which conventional current enters the device. This contrasts with a cathode, an electrode of the device through which conventional current leaves the device. A common mnemonic is ...
when an
electric potential The electric potential (also called the ''electric field potential'', potential drop, the electrostatic potential) is defined as the amount of work energy needed to move a unit of electric charge from a reference point to the specific point in ...
is applied across the silver
electrode An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials ...
s. This is the anodic reaction. :Ag \rightarrow Ag^+ +e^- The silver ions enter the solution at a rate proportional to the electrical current. Because the current is constant, the rate of silver ion production is hence proportional to the time of current flow, and silver ions enter the solution at a constant rate from the silver wire anode. These ions react with the chloride ions in the titration reaction, resulting in insoluble silver chloride. :Ag^+ + Cl^- \rightarrow AgCl The end point, which occurs when there are no more chloride ions with which silver ions may react, is detected by a pair of silver microelectrodes in the solution, which is connected in series with a microammeter. The increasing concentration of silver ions creates a current between the microelectrodes, activating a
switch In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type of ...
that shuts off power to the main electrodes and the timer, terminating the measurement. The duration of the titration is the titration time t_s, which is proportional to the amount of silver ions released, and hence to the amount of chloride in the assay solution.


Uses

Chloridometers are used to determine the concentration of chloride ions in biological fluids. For example, fish plasma chloride ion concentration is measured to gauge the effects of stress on
osmoregulation Osmoregulation is the active regulation of the osmotic pressure of an organism's body fluids, detected by osmoreceptors, to maintain the homeostasis of the organism's water content; that is, it maintains the fluid balance and the concentration o ...
in
aquaculture Aquaculture (less commonly spelled aquiculture), also known as aquafarming, is the controlled cultivation ("farming") of aquatic organisms such as fish, crustaceans, mollusks, algae and other organisms of value such as aquatic plants (e.g. lot ...
s. A small quantity of plasma (10 μL) combined with an acid
reagent In chemistry, a reagent ( ) or analytical reagent is a substance or compound added to a system to cause a chemical reaction, or test if one occurs. The terms ''reactant'' and ''reagent'' are often used interchangeably, but reactant specifies a ...
results in a
chemical reaction A chemical reaction is a process that leads to the chemical transformation of one set of chemical substances to another. Classically, chemical reactions encompass changes that only involve the positions of electrons in the forming and breaking ...
that ultimately provides a concentration measure of chloride ions in
meq An equivalent (symbol: officially equiv; unofficially but often Eq) is the amount of a substance that reacts with (or is ''equivalent'' to) an arbitrary amount (typically one mole) of another substance in a given chemical reaction. It is an arch ...
/L. Because they require
alternating current Alternating current (AC) is an electric current which periodically reverses direction and changes its magnitude continuously with time in contrast to direct current (DC) which flows only in one direction. Alternating current is the form in whic ...
, chloridometers are not portable and are better suited to a "bench-top location". This may necessitate freezing biological fluid specimens collected in the field for later analysis. Chloridometers represent the most common use of coulometry in clinical biochemistry.


Notes


References

* * * * *


Further reading

*{{cite book, title=Clinical chemistry: principles, procedures, correlations, editor-last1=Bishop, editor-first1=Michael L., editor-last2=Fody, editor-first2=Edward P., others=Janet L. Duben-Engelkirk, publisher=Lippincott, date=1985 Chlorine Measuring instruments Titration