HOME

TheInfoList



OR:

Amperometry in
chemistry Chemistry is the scientific study of the properties and behavior of matter. It is a natural science that covers the elements that make up matter to the compounds made of atoms, molecules and ions: their composition, structure, propertie ...
is detection of ions in a solution based on electric current or changes in electric current. Amperometry is used in
electrophysiology Electrophysiology (from Greek , ''ēlektron'', "amber" etymology of "electron"">Electron#Etymology">etymology of "electron" , ''physis'', "nature, origin"; and , ''-logia'') is the branch of physiology that studies the electrical properties of b ...
to study
vesicle Vesicle may refer to: ; In cellular biology or chemistry * Vesicle (biology and chemistry), a supramolecular assembly of lipid molecules, like a cell membrane * Synaptic vesicle ; In human embryology * Vesicle (embryology), bulge-like features ...
release events using a carbon fiber electrode. Unlike
patch clamp The patch clamp technique is a laboratory technique in electrophysiology used to study ionic currents in individual isolated living cells, tissue sections, or patches of cell membrane. The technique is especially useful in the study of excita ...
techniques, the
electrode An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials ...
used for amperometry is not inserted into or attached to the
cell Cell most often refers to: * Cell (biology), the functional basic unit of life Cell may also refer to: Locations * Monastic cell, a small room, hut, or cave in which a religious recluse lives, alternatively the small precursor of a monastery w ...
, but brought in close proximity of the cell. The measurements from the electrode originate from an oxidizing reaction of a vesicle cargo released into the medium. Another technique used to measure vesicle release is
capacitive A capacitor is a device that stores electrical energy in an electric field by virtue of accumulating electric charges on two close surfaces insulated from each other. It is a passive electronic component with two terminals. The effect of a c ...
measurements.


History

Electrochemical Electrochemistry is the branch of physical chemistry concerned with the relationship between electrical potential difference, as a measurable and quantitative phenomenon, and identifiable chemical change, with the potential difference as an outc ...
or amperometric detection as it was first used in ion chromatography was single-potential or DC amperometry, useful for certain electrochemically active ions such as cyanide, sulfite, and iodide. The development of pulsed amperometric detection (PAD) for analytes that fouled
electrode An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials ...
surfaces when detected eventually helped create a new category of ion chromatography for the determination of
carbohydrates In organic chemistry, a carbohydrate () is a biomolecule consisting of carbon (C), hydrogen (H) and oxygen (O) atoms, usually with a hydrogen–oxygen atom ratio of 2:1 (as in water) and thus with the empirical formula (where ''m'' may o ...
. Another advancement, known as integrated amperometry, has increased the sensitivity for other electrochemically active species, such as
amines In chemistry, amines (, ) are compounds and functional groups that contain a basic nitrogen atom with a lone pair. Amines are formally derivatives of ammonia (), wherein one or more hydrogen atoms have been replaced by a substituent ...
and many compounds that contain reduced
sulfur Sulfur (or sulphur in British English) is a chemical element with the symbol S and atomic number 16. It is abundant, multivalent and nonmetallic. Under normal conditions, sulfur atoms form cyclic octatomic molecules with a chemical formul ...
groups, that are sometimes weakly detected by PAD. It was established that
neurotransmitter A neurotransmitter is a signaling molecule secreted by a neuron to affect another cell across a synapse. The cell receiving the signal, any main body part or target cell, may be another neuron, but could also be a gland or muscle cell. Neuro ...
s could be electrochemically detected by placing a carbon electrode into tissue and recording the current from oxidizing neurotransmitters. One of the first measurements was made using an implanted carbon fiber electrode in the
neostriatum The striatum, or corpus striatum (also called the striate nucleus), is a nucleus (a cluster of neurons) in the subcortical basal ganglia of the forebrain. The striatum is a critical component of the motor and reward systems; receives glutama ...
of rats. Further work was done in chromaffin cells to investigate
catecholamine A catecholamine (; abbreviated CA) is a monoamine neurotransmitter, an organic compound that has a catechol (benzene with two hydroxyl side groups next to each other) and a side-chain amine. Catechol can be either a free molecule or a su ...
release from large dense core vesicles.


Detection methods


Single-potential amperometry

Any analyte that can be oxidized or reduced is a candidate for amperometric detection. The simplest form of amperometric detection is single-potential, or
direct current Direct current (DC) is one-directional flow of electric charge. An electrochemical cell is a prime example of DC power. Direct current may flow through a conductor such as a wire, but can also flow through semiconductors, insulators, or e ...
(DC), amperometry. A voltage (potential) is applied between two
electrodes An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit (e.g. a semiconductor, an electrolyte, a vacuum or air). Electrodes are essential parts of batteries that can consist of a variety of materials de ...
positioned in the column
effluent Effluent is wastewater from sewers or industrial outfalls that flows directly into surface waters either untreated or after being treated at a facility. The term has slightly different meanings in certain contexts, and may contain various polluta ...
. The measured current changes as an electroactive analyte is oxidized at the anode or reduced at the cathode. Single-potential amperometry has been used to detect weak acid anions, such as
cyanide Cyanide is a naturally occurring, rapidly acting, toxic chemical that can exist in many different forms. In chemistry, a cyanide () is a chemical compound that contains a functional group. This group, known as the cyano group, consists of ...
and
sulfide Sulfide (British English also sulphide) is an inorganic anion of sulfur with the chemical formula S2− or a compound containing one or more S2− ions. Solutions of sulfide salts are corrosive. ''Sulfide'' also refers to chemical compounds l ...
, which are problematic by conductometric methods. Another, possibly more important advantage of amperometry over other detection methods for these and other ions, such as iodide, sulfite, and
hydrazine Hydrazine is an inorganic compound with the chemical formula . It is a simple pnictogen hydride, and is a colourless flammable liquid with an ammonia-like odour. Hydrazine is highly toxic unless handled in solution as, for example, hydrazin ...
, is specificity. The applied potential can be adjusted to maximize the response for the analyte of interest while minimizing the response for interfering analytes


Pulsed amperometry (pulsed amperometric detection, PAD)

An extension of single-potential amperometry is pulsed amperometry, most commonly used for analytes that tend to foul electrodes. Analytes that foul electrodes reduce the signal with each analysis and necessitate cleaning of the electrode. In pulsed amperometric detection (PAD), a working potential is applied for a short time (usually a few hundred milliseconds), followed by higher or lower potentials that are used for cleaning the electrode. The current is measured only while the working potential is applied, then sequential current measurements are processed by the detector to produce a smooth output. PAD is most often used for detection of carbohydrates after an anion exchange separation, but further development of related techniques show promise for amines, reduced sulfur species, and other electroactive compounds.


Principle

In order to record vesicle fusion, a carbon fiber electrode is brought close to the cell. The electrode is held at a positive potential, and when the cargo from a fused vesicle is near the electrode, oxidation of the cargo transfers electrons to the electrode. This causes a spike, the size of which can be used to estimate the number of vesicles, and the frequency gives information about the release probability.


References

{{reflist Electrophysiology