Vectorscope
   HOME

TheInfoList



OR:

A vectorscope is a special type of
oscilloscope An oscilloscope (formerly known as an oscillograph, informally scope or O-scope) is a type of electronic test instrument that graphically displays varying voltages of one or more signals as a function of time. Their main purpose is capturing i ...
used in both audio and video applications. Whereas an oscilloscope or waveform monitor normally displays a plot of signal vs. time, a vectorscope displays an X-Y plot of two signals, which can reveal details about the relationship between these two signals. Vectorscopes are highly similar in operation to oscilloscopes operated in X-Y mode; however those used in video applications have specialized graticules, and accept standard television or video signals as input ( demodulating and demultiplexing the two components to be analyzed internally).


Applications


Video

In video applications, a vectorscope supplements a waveform monitor for the purpose of measuring and testing television signals, regardless of format (
NTSC NTSC (from National Television System Committee) is the first American standard for analog television, published and adopted in 1941. In 1961, it was assigned the designation System M. It is also known as EIA standard 170. In 1953, a second ...
, PAL,
SECAM SECAM, also written SÉCAM (, ''Séquentiel de couleur à mémoire'', French for ''sequential colour memory''), is an analog color television system that was used in France, Russia and some other countries or territories of Europe and Africa. ...
or any number of
digital television Digital television (DTV) is the transmission of television signals using Digital signal, digital encoding, in contrast to the earlier analog television technology which used analog signals. At the time of its development it was considered an ...
standards). While a waveform monitor allows a broadcast technician to measure the overall characteristics of a video signal, a vectorscope is used to visualize chrominance, which is encoded into the video signal as a subcarrier of specific
frequencies Frequency is the number of occurrences of a repeating event per unit of time. Frequency is an important parameter used in science and engineering to specify the rate of oscillatory and vibratory phenomena, such as mechanical vibrations, audio ...
. The vectorscope locks exclusively to the chrominance subcarrier in the video signal (at 3.58 MHz for NTSC or 4.43 MHz for PAL) to drive its display. In digital applications, a vectorscope instead plots the Cb and Cr channels against each other (these are the two channels in digital formats which contain chroma information). A vectorscope uses an overlaid circular reference display, or ''graticule'', for visualizing chrominance signals, which is the best method of referring to the QAM scheme used to encode color into a video signal. The actual visual pattern that the incoming chrominance signal draws on the vectorscope is called the ''trace''. Chrominance is measured using two methods—color saturation, encoded as the
amplitude The amplitude of a periodic variable is a measure of its change in a single period (such as time or spatial period). The amplitude of a non-periodic signal is its magnitude compared with a reference value. There are various definitions of am ...
, or gain, of the subcarrier signal, and hue, encoded as the subcarrier's phase. The vectorscope's graticule roughly represents saturation as distance from the center of the circle, and hue as the angle, in standard position, around it. The graticule is also embellished with several elements corresponding to the various components of the standard color bars video
test signal Test(s), testing, or TEST may refer to: * Test (assessment), an educational assessment intended to measure the respondents' knowledge or other abilities Arts and entertainment * ''Test'' (2013 film), an American film * ''Test'' (2014 film) ...
, including boxes around the circles for the colors in the main bars, and perpendicular lines corresponding to the U and V components of the chrominance signal (and additionally on an NTSC vectorscope, the I and Q components). NTSC vectorscopes have one set of boxes for the color bars, while their PAL counterparts have two sets of boxes, because the R-Y chrominance component in PAL reverses in phase on alternating lines. Another element in the graticule is a fine grid at 270° on the display (i.e. the -U position) used for measuring differential gain and phase. Often two sets of bar targets are provided: one for color bars at 75% amplitude and one for color bars at 100% amplitude. The 100% bars represent the maximum amplitude (of the composite signal) that composite encoding allows for. 100% bars are not suitable for broadcast and are not broadcast-safe. 75% bars have reduced amplitude and are broadcast-safe. Some vectorscope models have only one set of bar targets. The vectorscope can be set up for 75% or 100% bars by adjusting the gain so that the colorburst vector extends to the "75%" or "100%" marking on the graticule. The reference signal used for the vectorscope's display is the colorburst that is transmitted before each line of video, which for NTSC is defined to have a phase of 180°, corresponding to the -U position on the graticule. The actual colorburst signal shows up on the vectorscope as a straight line pointing to the left from the center of the graticule. In the case of PAL, the colorburst phase alternates between 135° and 225°, resulting in two vectors pointing in the half-past-ten and half-past-seven positions on the graticule, respectively. In digital (and component analog) vectorscopes, colorburst doesn't exist; hence the phase relationship between the colorburst signal and the chroma subcarrier is simply not an issue. A vectorscope for SECAM uses a demodulator similar to the one found in a SECAM receiver to retrieve the U and V color signals since they are transmitted one at a time, namely the Thomson 8300 Vecamscope. On older vectorscopes that use
cathode-ray tube A cathode-ray tube (CRT) is a vacuum tube containing one or more electron guns, which emit electron beams that are manipulated to display images on a phosphorescent screen. The images may represent electrical waveforms on an oscilloscope, a ...
s (CRTs), the graticule was often a silk-screened overlay superimposed over the front surface of the screen. One notable exception was the
Tektronix Tektronix, Inc., historically widely known as Tek, is an American company best known for manufacturing test and measurement devices such as oscilloscopes, logic analyzers, and video and mobile test protocol equipment. Originally an independent c ...
WFM601 series of instruments, which are combined waveform monitors and vectorscopes used to measure
CCIR 601 ITU-R Recommendation BT.601, more commonly known by the abbreviations Rec. 601 or BT.601 (or its former name CCIR 601), is a standard originally issued in 1982 by the Comité consultatif international pour la radio, CCIR (an organizati ...
television signals. The waveform-mode graticule of these instruments is implemented with a silkscreen, whereas the vectorscope graticule (consisting only of bar targets, as this family did not support composite video) was drawn on the CRT by the
electron beam Since the mid-20th century, electron-beam technology has provided the basis for a variety of novel and specialized applications in semiconductor manufacturing, microelectromechanical systems, nanoelectromechanical systems, and microscopy. Mechani ...
. Modern instruments have graticules drawn using computer graphics, and both graticule and trace are rendered on an external VGA monitor or an internal VGA-compatible
LCD A liquid-crystal display (LCD) is a flat-panel display or other electronically modulated optical device that uses the light-modulating properties of liquid crystals combined with polarizers to display information. Liquid crystals do not em ...
display. Most modern waveform monitors include vectorscope functionality built in; and many allow the two modes to be displayed side-by-side. The combined device is typically referred to as a waveform monitor, and standalone vectorscopes are rapidly becoming obsolete.


Audio

In audio applications, a vectorscope is used to measure the difference between channels of
stereo Stereophonic sound, commonly shortened to stereo, is a method of sound reproduction that recreates a multi-directional, 3-dimensional audible perspective. This is usually achieved by using two independent audio channels through a configurat ...
audio signals. One stereo channel drives the horizontal deflection of the display, and the other drives the vertical deflection. A monaural signal, consisting of identical left and right signals, results in a straight line with a
gradient In vector calculus, the gradient of a scalar-valued differentiable function f of several variables is the vector field (or vector-valued function) \nabla f whose value at a point p gives the direction and the rate of fastest increase. The g ...
of +1. Any stereo separation is visible as a deviation from this line, creating a Lissajous figure. If a straight line appears with a gradient of −1, this indicates that the left and right channels are 180° out of phase.


References


External links

*
"4kScope"
''Drastic Technologies Ltd.'' Software vectorscope with free training mode. {{Oscilloscopes Film and video technology Electronic test equipment Measuring instruments