HOME

TheInfoList



OR:

The Sagnac effect, also called Sagnac interference, named after French physicist
Georges Sagnac Georges Sagnac (14 October 1869 – 26 February 1928) was a French physicist who lent his name to the Sagnac effect, a phenomenon which is at the basis of interferometers and ring laser gyroscopes developed since the 1970s. Life and work Sagna ...
, is a phenomenon encountered in interferometry that is elicited by rotation. The Sagnac effect manifests itself in a setup called a ring interferometer or Sagnac interferometer. A beam of light is split and the two beams are made to follow the same path but in opposite directions. On return to the point of entry the two light beams are allowed to exit the ring and undergo interference. The relative phases of the two exiting beams, and thus the position of the interference fringes, are shifted according to the angular velocity of the apparatus. In other words, when the interferometer is at rest with respect to a nonrotating frame, the light takes the same amount of time to traverse the ring in either direction. However, when the interferometer system is spun, one beam of light has a longer path to travel than the other in order to complete one circuit of the mechanical frame, and so takes longer, resulting in a phase difference between the two beams.
Georges Sagnac Georges Sagnac (14 October 1869 – 26 February 1928) was a French physicist who lent his name to the Sagnac effect, a phenomenon which is at the basis of interferometers and ring laser gyroscopes developed since the 1970s. Life and work Sagna ...
set up this experiment in an attempt to prove the existence of the aether that Einstein's
theory of special relativity In physics, the special theory of relativity, or special relativity for short, is a scientific theory regarding the relationship between space and time. In Albert Einstein's original treatment, the theory is based on two postulates: # The laws ...
had discarded. A
gimbal A gimbal is a pivoted support that permits rotation of an object about an axis. A set of three gimbals, one mounted on the other with orthogonal pivot axes, may be used to allow an object mounted on the innermost gimbal to remain independent of ...
mounted mechanical gyroscope remains pointing in the same direction after spinning up, and thus can be used as a rotational reference for an
inertial navigation system An inertial navigation system (INS) is a navigation device that uses motion sensors (accelerometers), rotation sensors ( gyroscopes) and a computer to continuously calculate by dead reckoning the position, the orientation, and the velocity (dir ...
. With the development of so-called laser gyroscopes and fiber optic gyroscopes based on the Sagnac effect, bulky mechanical gyroscopes can be replaced by those with no moving parts in many modern inertial navigation systems. A conventional gyroscope relies on the principle of
conservation of angular momentum In physics, angular momentum (rarely, moment of momentum or rotational momentum) is the rotational analog of linear momentum. It is an important physical quantity because it is a conserved quantity—the total angular momentum of a closed syste ...
whereas the sensitivity of the ring interferometer to rotation arises from the invariance of the
speed of light The speed of light in vacuum, commonly denoted , is a universal physical constant that is important in many areas of physics. The speed of light is exactly equal to ). According to the special theory of relativity, is the upper limit ...
for all inertial frames of reference.


Description and operation

Typically three or more mirrors are used, so that counter-propagating light beams follow a closed path such as a triangle or square (Fig. 1). Alternatively fiber optics can be employed to guide the light through a closed path (Fig. 2). If the platform on which the ring interferometer is mounted is rotating, the interference fringes are displaced compared to their position when the platform is not rotating. The amount of displacement is proportional to the angular velocity of the rotating platform. The axis of rotation does not have to be inside the enclosed area. The phase shift of the interference fringes is proportional to the platform's
angular frequency In physics, angular frequency "''ω''" (also referred to by the terms angular speed, circular frequency, orbital frequency, radian frequency, and pulsatance) is a scalar measure of rotation rate. It refers to the angular displacement per unit tim ...
\boldsymbol and is given by a formula originally derived by Sagnac:\Delta \phi\approx \frac \boldsymbol\cdot \mathbf where \mathbf is the oriented area of the loop and \lambda the wavelength of light. The effect is a consequence of the different times it takes right and left moving light beams to complete a full round trip in the interferometer ring. The difference in travel times, when multiplied by the optical frequency c / \lambda, determines the phase difference \Delta \phi. The rotation thus measured is an absolute rotation, that is, the platform's rotation with respect to an
inertial reference frame In classical physics and special relativity, an inertial frame of reference (also called inertial reference frame, inertial frame, inertial space, or Galilean reference frame) is a frame of reference that is not undergoing any acceleration. ...
.


History

The
Michelson–Morley experiment The Michelson–Morley experiment was an attempt to detect the existence of the luminiferous aether, a supposed medium permeating space that was thought to be the carrier of light waves. The experiment was performed between April and July 188 ...
of 1887 had suggested that the hypothetical
luminiferous aether Luminiferous aether or ether ("luminiferous", meaning "light-bearing") was the postulated medium for the propagation of light. It was invoked to explain the ability of the apparently wave-based light to propagate through empty space (a vacuum), so ...
, if it existed, was completely dragged by the Earth. To test this hypothesis,
Oliver Lodge Sir Oliver Joseph Lodge, (12 June 1851 – 22 August 1940) was a British physicist and writer involved in the development of, and holder of key patents for, radio. He identified electromagnetic radiation independent of Hertz's proof and at his ...
in 1897 proposed that a giant ring interferometer be constructed to measure the rotation of the Earth; a similar suggestion was made by
Albert Abraham Michelson Albert Abraham Michelson FFRS HFRSE (surname pronunciation anglicized as "Michael-son", December 19, 1852 – May 9, 1931) was a German-born American physicist of Polish/Jewish origin, known for his work on measuring the speed of light and espe ...
in 1904. They hoped that with such an interferometer, it would be possible to decide between a stationary aether, versus aethers which are partially or completely dragged by the Earth. That is, if the hypothetical aether were carried along by the Earth (or by the interferometer) the result would be negative, while a stationary aether would give a positive result. An experiment conducted in 1911 by Franz Harress, aimed at making measurements of the Fresnel drag of light propagating through moving glass, was in 1920 recognized by Max von Laue as actually constituting a Sagnac experiment. Not aware of the Sagnac effect, Harress had realized the presence of an "unexpected bias" in his measurements, but was unable to explain its cause. English translation: On the Experiment of F. Harress The first description of the Sagnac effect in the framework of special relativity was done by Laue in 1911, English translation: On an Experiment on the Optics of Moving Bodies two years before Sagnac conducted his experiment. By continuing the theoretical work of Michelson (1904), von Laue confined himself to an
inertial frame of reference In classical physics and special relativity, an inertial frame of reference (also called inertial reference frame, inertial frame, inertial space, or Galilean reference frame) is a frame of reference that is not undergoing any acceleration. ...
(which he called a "valid" reference frame), and in a footnote he wrote "a system which rotates in respect to a valid system K^0 is ''not'' valid". Assuming constant light speed c, and setting the rotational velocity as \omega, he computed the propagation time \tau_ of one ray and \tau_ of the counter-propagating ray, and consequently obtained the time difference \Delta\tau=\tau_-\tau_. He concluded that this interferometer experiment would indeed produce (when restricted to terms of first order in v/c) the same positive result for both special relativity and the stationary aether (the latter he called "absolute theory" in reference to the 1895-theory of Lorentz). He also concluded that only complete-aether-drag models (such as the ones of Stokes or
Hertz The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), equivalent to one event (or cycle) per second. The hertz is an SI derived unit whose expression in terms of SI base units is s−1, meaning that o ...
) would give a negative result. In practice, the first interferometry experiment aimed at observing the correlation of angular velocity and phase-shift was performed by the French scientist
Georges Sagnac Georges Sagnac (14 October 1869 – 26 February 1928) was a French physicist who lent his name to the Sagnac effect, a phenomenon which is at the basis of interferometers and ring laser gyroscopes developed since the 1970s. Life and work Sagna ...
in 1913. Its purpose was to detect "the effect of the relative motion of the ether". Sagnac believed that his results constituted proof of the existence of a stationary aether. However, as explained above, Max von Laue already showed in 1911 that this effect is consistent with special relativity. Unlike the carefully prepared
Michelson–Morley experiment The Michelson–Morley experiment was an attempt to detect the existence of the luminiferous aether, a supposed medium permeating space that was thought to be the carrier of light waves. The experiment was performed between April and July 188 ...
which was set up to prove an aether wind caused by earth drag, the Sagnac experiment could not prove this type of aether wind because a universal aether would affect all parts of the rotating light equally. Einstein was fully aware of the phenomenon of the Sagnac effect through the earlier experimentation of Franz Harress, mathematically analyzed in an article by Paul Harzer, entitled "Dragging of Light in Glass and Aberration" in 1914. This was rebutted by Einstein in his articles "Observation on P. Harzer's Article: Dragging of Light in Glass and Aberration" and "Answer to P. Harzer's Reply." After Einstein's mathematical argument in the first article, Einstein replied, "As I have shown, the frequency of the light relative to the medium through which it is applied is decisive for the magnitude k; because this determines the speed of the light relative to the medium. In our case, it is a light process which, in relation to the rotating prism system, is to be understood as a stationary process. From this it follows that the frequency of the light relative to the moving prisms, and also the magnitude k, is the same for all prisms. This repudiates Mr Harzer's reply." (1914) In 1920 von Laue continued his own theoretical work of 1911, describing the Harress experiment and showing the role of the Sagnac effect in this experiment. Laue said that in the Harress experiment (in which light traverses glass) there was a calculable difference in time due to both the dragging of light (which follows from the relativistic velocity addition in moving media, i.e. in moving glass) and "the fact that every part of the rotating apparatus runs away from one ray, while it approaches the other one", i.e. the Sagnac effect. He acknowledged that this latter effect alone could cause the time variance and, therefore, "the accelerations connected with the rotation in no way influence the speed of light." While Laue's explanation is based on inertial frames,
Paul Langevin Paul Langevin (; ; 23 January 1872 – 19 December 1946) was a French physicist who developed Langevin dynamics and the Langevin equation. He was one of the founders of the ''Comité de vigilance des intellectuels antifascistes'', an an ...
(1921, 1937) and others described the same effect when viewed from rotating reference frames (in both special and general relativity, see Born coordinates). So when the Sagnac effect should be described from the viewpoint of a corotating frame, one can use ordinary rotating cylindrical coordinates and apply them to the
Minkowski metric In mathematical physics, Minkowski space (or Minkowski spacetime) () is a combination of three-dimensional Euclidean space and time into a four-dimensional manifold where the spacetime interval between any two events is independent of the iner ...
, which results into the so-called Born metric or Langevin metric. (Open access) From these coordinates, one can derive the different arrival times of counter-propagating rays, an effect which was shown by
Paul Langevin Paul Langevin (; ; 23 January 1872 – 19 December 1946) was a French physicist who developed Langevin dynamics and the Langevin equation. He was one of the founders of the ''Comité de vigilance des intellectuels antifascistes'', an an ...
(1921). Or when these coordinates are used to compute the global speed of light in rotating frames, different apparent light speeds are derived depending on the orientation, an effect which was shown by Langevin in another paper (1937). This does not contradict special relativity and the above explanation by von Laue that the speed of light is not affected by accelerations. Because this apparent variable light speed in rotating frames only arises if rotating coordinates are used, whereas if the Sagnac effect is described from the viewpoint of an external inertial coordinate frame the speed of light of course remains constant – so the Sagnac effect arises no matter whether one uses inertial coordinates (see the formulas in section below) or rotating coordinates (see the formulas in section below). That is, special relativity in its original formulation was adapted to inertial coordinate frames, not rotating frames. Albert Einstein in his paper introducing special relativity stated, "light is always propagated in empty space with a definite velocity c which is independent of the state of motion of the emitting body." Einstein specifically stated that light speed is only constant in the vacuum of empty space, using equations that only held in linear and parallel inertial frames. However, when Einstein started to investigate accelerated reference frames, he noticed that “the principle of the constancy of light must be modified” for accelerating frames of reference. Max von Laue in his 1920 paper gave serious consideration to the effect of
General Relativity General relativity, also known as the general theory of relativity and Einstein's theory of gravity, is the geometric theory of gravitation published by Albert Einstein in 1915 and is the current description of gravitation in modern physics ...
on the Sagnac effect stating, "General relativity would of course be capable of giving some statements about it, and we want to show at first that no noticeable influences of acceleration are expected according to it." He makes a footnote regarding discussions with German physicist,
Wilhelm Wien Wilhelm Carl Werner Otto Fritz Franz Wien (; 13 January 1864 – 30 August 1928) was a German physicist who, in 1893, used theories about heat and electromagnetism to deduce Wien's displacement law, which calculates the emission of a blackbody ...
. The reason for looking at
General Relativity General relativity, also known as the general theory of relativity and Einstein's theory of gravity, is the geometric theory of gravitation published by Albert Einstein in 1915 and is the current description of gravitation in modern physics ...
is because Einstein's
Theory of General Relativity General relativity, also known as the general theory of relativity and Einstein's theory of gravity, is the geometric theory of gravitation published by Albert Einstein in 1915 and is the current description of gravitation in modern physics. G ...
predicted that light would slow down in a gravitational field which is why it could predict the curvature of light around a massive body. Under General Relativity, there is the equivalence principle which states that gravity and acceleration are equivalent. Spinning or accelerating an interferometer creates a gravitational effect. "There are, however, two different types of such on-inertialmotion; it may for instance be acceleration in a straight line, or circular motion with constant speed." Also, Irwin Shapiro in 1964 explained General Relativity saying, "the speed of a light wave depends on the strength of the gravitational potential along its path." This is called the Shapiro delay. However, since the gravitational field would have to be significant, Laue (1920) concluded it is more likely that the effect is a result of changing the distance of the path by its movement through space. "The beam traveling around the loop in the direction of rotation will have farther to go than the beam traveling counter to the direction of rotation, because during the period of travel the mirrors and detector will all move (slightly) toward the counter-rotating beam and away from the co-rotating beam. Consequently the beams will reach the detector at slightly different times, and slightly out of phase, producing optical interference 'fringes' that can be observed and measured." In 1926, an ambitious ring interferometry experiment was set up by Albert Michelson and Henry Gale. The aim was to find out whether the rotation of the Earth has an effect on the propagation of light in the vicinity of the Earth. The Michelson–Gale–Pearson experiment was a very large ring interferometer, (a perimeter of 1.9 kilometer), large enough to detect the angular velocity of the Earth. The outcome of the experiment was that the angular velocity of the Earth as measured by astronomy was confirmed to within measuring accuracy. The ring interferometer of the Michelson–Gale experiment was not calibrated by comparison with an outside reference (which was not possible, because the setup was fixed to the Earth). From its design it could be deduced where the central interference fringe ought to be if there would be zero shift. The measured shift was 230 parts in 1000, with an accuracy of 5 parts in 1000. The predicted shift was 237 parts in 1000. The Sagnac effect has stimulated a century long debate on its meaning and interpretation, much of this debate being surprising since the effect is perfectly well understood in the context of special relativity.


Theory


Basic case

The shift in interference fringes in a ring interferometer can be viewed intuitively as a consequence of the different ''distances'' that light travels due to the rotation of the ring.(Fig. 3) The simplest derivation is for a circular ring of radius R, with a refractive index of one, rotating at an angular velocity of \omega , but the result is general for loop geometries with other shapes. If a light source emits in both directions from one point on the rotating ring, light traveling in the same direction as the rotation direction needs to travel more than one circumference around the ring before it catches up with the light source from behind. The time t_1 that it takes to catch up with the light source is given by: : t_1 = \frac c \Delta L is the distance (black bold arrow in Fig. 3) that the mirror has moved in that same time: : \Delta L = R \omega t_1. \, Eliminating \Delta L from the two equations above we get: : t_1 = \frac . Likewise, the light traveling in the opposite direction of the rotation will travel less than one circumference before hitting the light source on the front side. So the time for this direction of light to reach the moving source again is: : t_2 = \frac . The time difference is : \Delta t = t_1 - t_2 = \frac . For R \omega = v \ll c , this reduces to : \Delta t \approx \frac = \frac , where ''A'' is the area of the ring. Although this simple derivation is for a circular ring with an index of refraction of one, the result holds true for any shape of rotating loop with area ''A''.(Fig. 4) For more complicated shapes, or other refractive index values, the same result can be derived by calculating the optical phase shift in each direction using
Fermat's principle Fermat's principle, also known as the principle of least time, is the link between ray optics and wave optics. In its original "strong" form, Fermat's principle states that the path taken by a ray between two given points is the pat ...
and taking into account the different phase velocities for the different propagation directions in an inertial laboratory frame, which can be calculated using relativistic addition of velocities. We imagine a screen for viewing fringes placed at the light source (or we use a beamsplitter to send light from the source point to the screen). Given a steady light source, interference fringes will form on the screen with a fringe displacement proportional to the time differences required for the two counter-rotating beams to traverse the circuit. The phase shift is \Delta \phi=\frac , which causes fringes to shift in proportion to A and \omega . At non-relativistic speeds, the Sagnac effect is a simple consequence of the source independence of the speed of light. In other words, the Sagnac experiment does not distinguish between pre-relativistic physics and relativistic physics. When light propagates in fibre optic cable, the setup is effectively a combination of a Sagnac experiment and the
Fizeau experiment The Fizeau experiment was carried out by Hippolyte Fizeau in 1851 to measure the relative speeds of light in moving water. Fizeau used a special interferometer arrangement to measure the effect of movement of a medium upon the speed of light. ...
. In glass the speed of light is slower than in vacuum, and the optical cable is the moving medium. In that case the relativistic velocity addition rule applies. Pre-relativistic theories of light propagation cannot account for the Fizeau effect. (By 1900 Lorentz could account for the Fizeau effect, but by that time his theory had evolved to a form where in effect it was mathematically equivalent to special relativity.) Since emitter and detector are traveling at the same speeds, Doppler effects cancel out, so the Sagnac effect does not involve the Doppler effect. In the case of ring laser interferometry, it is important to be aware of this. When the ring laser setup is rotating, the counterpropagating beams undergo frequency shifts in opposite directions. This frequency shift is not a Doppler shift, but is rather an optical cavity resonance effect, as explained below in Ring lasers. The Sagnac effect is well understood in the context of special relativity where from the rotating light source's point of view the phase difference is due to the line of simultaneity along the light path not forming a closed loop in spacetime.


Generalized formula

Modified versions of the experiment have been proposed with the light source allowed to ''move'' along a (not necessarily circular) light path. This configuration introduces another reason for the phase difference: according to the light source the two signals now follow ''different'' paths in space. Some authors refer to this effect as Sagnac effect although in this case the discrepancy need not be due to the lines of simultaneity not forming closed loops. An example of the modified configuration is shown in Fig. 5, the measured phase difference in both a standard fibre optic gyroscope, shown on the left, and a modified fibre optic conveyor, shown on the right, conform to the equation Δ''t'' = 2''vL''/''c''2, whose derivation is based on the constant speed of light. It is evident from this formula that the total time delay is equal to the cumulative time delays along the entire length of fibre, regardless whether the fibre is in a rotating section of the conveyor, or a straight section. This equation is invalid, however, if the light source's path in space does not follow that of the light signals, for example in the standard rotating platform case (FOG) but with a non-circular light path. In this case the phase difference formula necessarily involves the area enclosed by the light path due to Stokes' theorem. Consider a ring interferometer where two counter-propagating light beams share a common optical path determined by a loop of an optical fiber, see Figure 4. The loop may have an arbitrary shape, and can move arbitrarily in space. The only restriction is that it is not allowed to stretch. (The case of a circular ring interferometer rotating about its center in free space is recovered by taking the index of refraction of the fiber to be 1.) Consider a small segment of the fiber, whose length in its rest frame is d\ell'. The time intervals, dt'_\pm, it takes the left and right moving light rays to traverse the segment in the rest frame coincide and are given bydt'_\pm= d \ell'Let d\ell=, d\mathbf, be the length of this small segment in the lab frame. By the relativistic length contraction formula, d\ell'=\gamma d\ell\approx d\ell correct to first order in the velocity \mathbf of the segment. The time intervals dt_\pm for traversing the segment in the lab frame are given by
Lorentz transformation In physics, the Lorentz transformations are a six-parameter family of Linear transformation, linear coordinate transformation, transformations from a Frame of Reference, coordinate frame in spacetime to another frame that moves at a constant velo ...
as:dt_\pm=\gamma \left(dt' \pm \frac\right)\approx \frac n c d\ell \pm \frac\cdot d\mathbfcorrect to first order in the velocity \mathbf. In general, the two beams will visit a given segment at slightly different times, but, in the absence of stretching, the length d\ell is the same for both beams. It follows that the time difference for completing a cycle for the two beams is\Delta T= \int \left(dt_+-dt_-\right)\approx \frac 2 \oint \mathbf\cdot d\mathbfRemarkably, the time difference is independent of the refraction index n and the velocity of light in the fiber. Imagine a screen for viewing fringes placed at the light source (alternatively, use a beamsplitter to send light from the source point to the screen). Given a steady light source, interference fringes will form on the screen with a fringe displacement given by \Delta \phi\approx \frac \Delta T where the first factor is the frequency of light. This gives the generalized Sagnac formula\Delta \phi\approx \frac \oint \mathbf\cdot d\mathbfIn the special case that the fiber moves like a rigid body with angular frequency \boldsymbol, the velocity is \mathbf=\boldsymbol\times\mathbf and the line integral can be computed in terms of the area of the loop:\oint\mathbf\cdot d\mathbf=\oint\boldsymbol\times\mathbf\cdot d\mathbf= \oint\boldsymbol\cdot\mathbf\times d\mathbf=2\oint\boldsymbol\cdot d\mathbf= 2\boldsymbol\cdot \mathbfThis gives Sagnac formula for ring interferometers of arbitrary shape and geometry\Delta \phi\approx \frac \boldsymbol\cdot \mathbf If one also allows for stretching one recovers the Fizeau interference formula.


Applications

A relay of pulses that circumnavigates the Earth, verifying precise synchronization, is also recognized as a case requiring correction for the Sagnac effect. In 1984 a verification was set up that involved three ground stations and several GPS satellites, with relays of signals both going eastward and westward around the world. In the case of a Sagnac interferometer a measure of difference in arrival time is obtained by producing interference fringes, and observing the fringe shift. In the case of a relay of pulses around the world the difference in arrival time is obtained directly from the actual arrival time of the pulses. In both cases the mechanism of the difference in arrival time is the same: the Sagnac effect. The Hafele–Keating experiment is also recognized as a counterpart to Sagnac effect physics. In the actual Hafele–Keating experiment the mode of transport (long-distance flights) gave rise to time dilation effects of its own, and calculations were needed to separate the various contributions. For the (theoretical) case of clocks that are transported so slowly that time dilation effects arising from the transport are negligible the amount of time difference between the clocks when they arrive back at the starting point will be equal to the time difference that is found for a relay of pulses that travels around the world: 207 nanoseconds.


Practical uses

The Sagnac effect is employed in current technology. One use is in inertial guidance systems. Ring laser gyroscopes are extremely sensitive to rotations, which need to be accounted for if an inertial guidance system is to return accurate results. The ring laser also can detect the
sidereal day Sidereal time (as a unit also sidereal day or sidereal rotation period) (sidereal ) is a timekeeping system that astronomers use to locate celestial objects. Using sidereal time, it is possible to easily point a telescope to the proper coor ...
, which can also be termed "mode 1".
Global navigation satellite system A satellite navigation or satnav system is a system that uses satellites to provide autonomous geo-spatial positioning. It allows satellite navigation devices to determine their location (longitude, latitude, and altitude/elevation) to high pr ...
s (GNSSs), such as
GPS The Global Positioning System (GPS), originally Navstar GPS, is a satellite-based radionavigation system owned by the United States government and operated by the United States Space Force. It is one of the global navigation satellite sy ...
,
GLONASS GLONASS (russian: ГЛОНАСС, label=none, ; rus, links=no, Глобальная навигационная спутниковая система, r=Global'naya Navigatsionnaya Sputnikovaya Sistema, t=Global Navigation Satellite System) is ...
,
COMPASS A compass is a device that shows the cardinal directions used for navigation and geographic orientation. It commonly consists of a magnetized needle or other element, such as a compass card or compass rose, which can pivot to align itself wit ...
or Galileo, need to take the rotation of the Earth into account in the procedures of using radio signals to synchronize clocks.


Ring lasers

Fibre optic gyroscopes are sometimes referred to as 'passive ring interferometers'. A passive ring interferometer uses light entering the setup from outside. The interference pattern that is obtained is a fringe pattern, and what is measured is a phase shift. It is also possible to construct a ring interferometer that is self-contained, based on a completely different arrangement. This is called a ring laser or ring laser gyroscope. The light is generated and sustained by incorporating laser excitation in the path of the light. To understand what happens in a ring laser cavity, it is helpful to discuss the physics of the laser process in a laser setup with continuous generation of light. As the laser excitation is started, the molecules inside the cavity emit photons, but since the molecules have a thermal velocity, the light inside the laser cavity is at first a range of frequencies, corresponding to the statistical distribution of velocities. The process of stimulated emission makes one frequency quickly outcompete other frequencies, and after that the light is very close to monochromatic. For the sake of simplicity, assume that all emitted photons are emitted in a direction parallel to the ring. Fig. 7 illustrates the effect of the ring laser's rotation. In a linear laser, an integer multiple of the wavelength fits the length of the laser cavity. This means that in traveling back and forth the laser light goes through an integer number of ''cycles'' of its frequency. In the case of a ring laser the same applies: the number of cycles of the laser light's frequency is the same in both directions. This quality of the same number of cycles in both directions is preserved when the ring laser setup is rotating. The image illustrates that there is wavelength shift (hence a frequency shift) in such a way that the number of cycles is the same in both directions of propagation. By bringing the two frequencies of laser light to interference a
beat frequency In acoustics, a beat is an interference pattern between two sounds of slightly different frequencies, ''perceived'' as a periodic variation in volume whose rate is the difference of the two frequencies. With tuning instruments that can produce ...
can be obtained; the beat frequency is the difference between the two frequencies. This beat frequency can be thought of as an interference pattern in time. (The more familiar interference fringes of interferometry are a spatial pattern). The period of this beat frequency is linearly proportional to the angular velocity of the ring laser with respect to inertial space. This is the principle of the ring laser gyroscope, widely used in modern
inertial navigation system An inertial navigation system (INS) is a navigation device that uses motion sensors (accelerometers), rotation sensors ( gyroscopes) and a computer to continuously calculate by dead reckoning the position, the orientation, and the velocity (dir ...
s.


Zero point calibration

In passive ring interferometers, the fringe displacement is proportional to the first derivative of angular position; careful calibration is required to determine the fringe displacement that corresponds to zero angular velocity of the ring interferometer setup. On the other hand, ring laser interferometers do not require calibration to determine the output that corresponds to zero angular velocity. Ring laser interferometers are self-calibrating. The beat frequency will be zero if and only if the ring laser setup is non-rotating with respect to inertial space. Fig. 8 illustrates the physical property that makes the ring laser interferometer self-calibrating. The grey dots represent molecules in the laser cavity that act as resonators. Along every section of the ring cavity, the speed of light is the same in both directions. When the ring laser device is rotating, then it rotates with respect to that background. In other words: invariance of the speed of light provides the reference for the self-calibrating property of the ring laser interferometer.


Lock-in

Ring laser gyroscopes suffer from an effect known as "lock-in" at low rotation rates (less than 100°/h). At very low rotation rates, the frequencies of the counter-propagating laser modes become almost identical. In this case, crosstalk between the counter-propagating beams can result in
injection locking Injection locking and injection pulling are the frequency effects that can occur when a harmonic oscillator is disturbed by a second oscillator operating at a nearby frequency. When the coupling is strong enough and the frequencies near enough, th ...
, so that the standing wave "gets stuck" in a preferred phase, locking the frequency of each beam to each other rather than responding to gradual rotation. By rotationally
dithering Dither is an intentionally applied form of noise used to randomize quantization error, preventing large-scale patterns such as color banding in images. Dither is routinely used in processing of both digital audio and video data, and is often ...
the laser cavity back and forth through a small angle at a rapid rate (hundreds of
hertz The hertz (symbol: Hz) is the unit of frequency in the International System of Units (SI), equivalent to one event (or cycle) per second. The hertz is an SI derived unit whose expression in terms of SI base units is s−1, meaning that o ...
), lock-in will only occur during the brief instances where the rotational velocity is close to zero; the errors thereby induced approximately cancel each other between alternating dead periods.


Fibre optic gyroscopes ''versus'' ring laser gyroscopes

Fibre optic gyros (FOGs) and ring laser gyros (RLGs) both operate by monitoring the difference in propagation time between beams of light traveling in clockwise and counterclockwise directions about a closed optical path. They differ considerably in various cost, reliability, size, weight, power, and other performance characteristics that need to be considered when evaluating these distinct technologies for a particular application. RLGs require accurate machining, use of precision mirrors, and assembly under clean room conditions. Their mechanical dithering assemblies add somewhat to their weight but not appreciably. RLGs are capable of logging in excess of 100,000 hours of operation in near-room temperature conditions. Their lasers have relatively high power requirements. Interferometric FOGs are purely solid-state, require no mechanical dithering components, do not require precision machining, have a flexible geometry, and can be made very small. They use many standard components from the telecom industry. In addition, the major optical components of FOGs have proven performance in the telecom industry, with lifespans measured in decades. However, the assembly of multiple optical components into a precision gyro instrument is costly. Analog FOGs offer the lowest possible cost but are limited in performance; digital FOGs offer the wide dynamic ranges and accurate scale factor corrections required for stringent applications. Use of longer and larger coils increases sensitivity at the cost of greater sensitivity to temperature variations and vibrations.


Zero-area Sagnac interferometer and gravitational wave detection

The Sagnac topology was actually first described by Michelson in 1886, who employed an even-reflection variant of this interferometer in a repetition of the
Fizeau experiment The Fizeau experiment was carried out by Hippolyte Fizeau in 1851 to measure the relative speeds of light in moving water. Fizeau used a special interferometer arrangement to measure the effect of movement of a medium upon the speed of light. ...
. Michelson noted the extreme stability of the fringes produced by this form of interferometer: White-light fringes were observed immediately upon alignment of the mirrors. In dual-path interferometers, white-light fringes are difficult to obtain since the two path lengths must be matched to within a couple of
micrometers The micrometre ( international spelling as used by the International Bureau of Weights and Measures; SI symbol: μm) or micrometer (American spelling), also commonly known as a micron, is a unit of length in the International System of Unit ...
(the
coherence length In physics, coherence length is the propagation distance over which a coherent wave (e.g. an electromagnetic wave) maintains a specified degree of coherence. Wave interference is strong when the paths taken by all of the interfering waves dif ...
of the white light). However, being a
common-path interferometer A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interf ...
, the Sagnac configuration inherently matches the two path lengths. Likewise Michelson observed that the fringe pattern would remain stable even while holding a lighted match below the optical path; in most interferometers the fringes would shift wildly due to the
refractive index In optics, the refractive index (or refraction index) of an optical medium is a dimensionless number that gives the indication of the light bending ability of that medium. The refractive index determines how much the path of light is bent, or ...
fluctuations from the warm air above the match. Sagnac interferometers are almost completely insensitive to displacements of the mirrors or beam-splitter. This characteristic of the Sagnac topology has led to their use in applications requiring exceptionally high stability. The fringe shift in a Sagnac interferometer due to rotation has a magnitude proportional to the enclosed area of the light path, and this area must be specified in relation to the axis of rotation. Thus the sign of the area of a loop is reversed when the loop is wound in the opposite direction (clockwise or anti-clockwise). A light path that includes loops in both directions, therefore, has a net area given by the difference between the areas of the clockwise and anti-clockwise loops. The special case of two equal but opposite loops is called a ''zero-area'' Sagnac interferometer. The result is an interferometer that exhibits the stability of the Sagnac topology while being insensitive to rotation. The
Laser Interferometer Gravitational-Wave Observatory The Laser Interferometer Gravitational-Wave Observatory (LIGO) is a large-scale physics experiment and observatory designed to detect cosmic gravitational waves and to develop gravitational-wave observations as an astronomical tool. Two large ...
(LIGO) consisted of two 4-km Michelson–Fabry–Pérot interferometers, and operated at a power level of about 100 watts of laser power at the beam splitter. After an upgrade to Advanced LIGO several kilowatts of laser power are required. A variety of competing optical systems are being explored for third generation enhancements beyond Advanced LIGO. One of these competing proposals is based on the zero-area Sagnac design. With a light path consisting of two loops of the same area, but in opposite directions, an effective area of zero is obtained thus canceling the Sagnac effect in its usual sense. Although insensitive to low frequency mirror drift, laser frequency variation, reflectivity imbalance between the arms, and thermally induced birefringence, this configuration is nevertheless sensitive to passing gravitational waves at frequencies of astronomical interest. However, many considerations are involved in the choice of an optical system, and despite the zero-area Sagnac's superiority in certain areas, there is as yet no consensus choice of optical system for third generation LIGO.


See also

* Born coordinates * Fiber optic gyroscope * Ring laser gyroscope


References


External links

* Mathpages
The Sagnac Effect

Ring-laser tests of fundamental physics and geophysics
(Extensive review by G E Stedman. PDF-file, 1.5 MB) * (Open access) {{DEFAULTSORT:Sagnac Effect Physics experiments Interferometry Theory of relativity