Reactive Power Management
   HOME

TheInfoList



OR:

Voltage control and reactive power management are two facets of an
ancillary service Ancillary services are the services necessary to support the transmission of electric power from power plant, generators to consumers given the obligations of control areas and transmission utilities within those control areas to maintain reliable ...
that enables reliability of the transmission networks and facilitates the
electricity market An electricity market is a system that enables the exchange of electrical energy, through an electrical grid. Historically, electricity has been primarily sold by companies that operate electric generators, and purchased by consumers or electr ...
on these networks. Both aspects of this activity are intertwined (voltage change in an
alternating current Alternating current (AC) is an electric current that periodically reverses direction and changes its magnitude continuously with time, in contrast to direct current (DC), which flows only in one direction. Alternating current is the form in w ...
(AC) network is effected through production or absorption of
reactive power In an electric circuit, instantaneous power is the time rate of flow of energy past a given point of the circuit. In alternating current circuits, energy storage elements such as inductors and capacitors may result in periodic reversals of the ...
), so within this article the term ''voltage control'' will be primarily used to designate this essentially single activity, as suggested by Kirby & Hirst (1997). Voltage control does not include reactive power injections to dampen the grid oscillations; these are a part of a separate ancillary service, so-called system stability service. The transmission of reactive power is limited by its nature, so the voltage control is provided through pieces of equipment distributed throughout the power grid, unlike the frequency control that is based on maintaining the overall active power balance in the system.


Need for voltage control

Kirby & Hirst indicate three reasons behind the need for voltage control: # the power network equipment is designed for a narrow voltage range, so is the power consuming equipment on the customer side. Operation outside of this range will cause the equipment to fail; # reactive power causes heating in the generators and the transmission lines, thermal limits will require restricting the production and the flow of real (
active Active may refer to: Music * ''Active'' (album), a 1992 album by Casiopea * "Active" (song), a 2024 song by Asake and Travis Scott from Asake's album ''Lungu Boy'' * Active Records, a record label Ships * ''Active'' (ship), several com ...
) power; # injection of reactive power into transmission lines causes losses that waste power, forcing an increase in power supplied by the
prime mover Prime mover may refer to: Philosophy *Unmoved mover, a concept in Aristotle's writings Engineering * Prime mover (engine or motor), a machine that converts various other forms of energy (chemical, electrical, fluid pressure/flow, etc.) into ener ...
. Use of specialized voltage control devices in the grid also improves the
power system stability The utility frequency, (power) line frequency (American English) or mains frequency (British English) is the nominal frequency of the oscillations of alternating current (AC) in a wide area synchronous grid transmitted from a power station to t ...
by reducing the fluctuations of the rotor angle of a synchronous generator (that are caused by generators sourcing or sinking the reactive power). Power buses and systems that exhibit large changes in voltage when the reactive power conditions change are called ''weak systems'', while the ones that have relatively smaller changes are ''strong'' (numerically, the strength is expressed as a short circuit ratio that is higher for the stronger systems).


Absorption and production of reactive power

Devices absorb reactive energy if they have lagging
power factor In electrical engineering, the power factor of an AC power system is defined as the ratio of the ''real power'' absorbed by the electrical load, load to the ''apparent power'' flowing in the circuit. Real power is the average of the instantaneou ...
(are
inductor An inductor, also called a coil, choke, or reactor, is a Passivity (engineering), passive two-terminal electronic component, electrical component that stores energy in a magnetic field when an electric current flows through it. An inductor typic ...
-like) and produce reactive energy if they have a leading power factor (are
capacitor In electrical engineering, a capacitor is a device that stores electrical energy by accumulating electric charges on two closely spaced surfaces that are insulated from each other. The capacitor was originally known as the condenser, a term st ...
-like). Electric grid equipment units typically either supply or consume the reactive power: * Synchronous generators will provide reactive power if overexcited and absorb it if underexcited, subject to the limits of the generator capability curve. *
Transformer In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple Electrical network, circuits. A varying current in any coil of the transformer produces ...
s will always absorb the reactive power. * Power lines will either absorb or provide reactive power:
overhead power lines An overhead power line is a structure used in electric power transmission and Electric power distribution, distribution to transmit electrical energy along large distances. It consists of one or more electrical conductor, conductors (commonly mu ...
will provide reactive power at low load, but as the load increases past the surge impedance of the line, the lines start consuming an increasing amount of reactive power.
Underground power lines An underground power line provides electrical power with underground cables. Compared to overhead power lines, underground lines have lower risk of starting a wildfire and reduce the risk of the electrical supply being interrupted by outages d ...
are capacitive, so they are loaded below the surge impedance and provide reactive power. *
Electrical load An electrical load is an electrical component or portion of a Electric Circuit, circuit that consumes (active) electric power, such as electrical appliances and Electric light, lights inside the home. The term may also refer to the power Power con ...
s usually absorb the reactive power, with the power factor for typical appliances ranging from 0.65 (household equipment with electrical motors, like a
washing machine A washing machine (laundry machine, clothes washer, washer, or simply wash) is a machine designed to laundry, launder clothing. The term is mostly applied to machines that use water. Other ways of doing laundry include dry cleaning (which uses ...
) to 1.0 (purely resistive loads like
incandescent lamp An incandescent light bulb, also known as an incandescent lamp or incandescent light globe, is an electric light that produces illumination by Joule heating a filament until it glows. The filament is enclosed in a glass bulb that is eith ...
s). In a typical electrical grid, the basics of the voltage control are provided by the synchronous generators. These generators are equipped with automatic voltage regulators that adjust the excitation field keeping the voltage at the generator's terminals within the target range. The task of additional reactive power compensation (also known as voltage compensation) is assigned to ''compensating devices'': * passive (either permanently connected or switched) sinks of reactive power (e.g., shunt reactors that are similar to transformers in construction, with a single
winding An electromagnetic coil is an electrical conductor such as a wire in the shape of a coil ( spiral or helix). Electromagnetic coils are used in electrical engineering, in applications where electric currents interact with magnetic fields, in ...
and iron
core Core or cores may refer to: Science and technology * Core (anatomy), everything except the appendages * Core (laboratory), a highly specialized shared research resource * Core (manufacturing), used in casting and molding * Core (optical fiber ...
). A shunt reactor is typically connected to an end of a long transmission line or a weak system to prevent overvoltage under light load (
Ferranti effect In electrical engineering, the Ferranti effect is the increase in voltage occurring at the receiving end of a very long (> 200 km) AC electric power transmission line, relative to the voltage at the sending end, when the load is very small, or n ...
); * passive sources of reactive power (e. g., shunt or
series Series may refer to: People with the name * Caroline Series (born 1951), English mathematician, daughter of George Series * George Series (1920–1995), English physicist Arts, entertainment, and media Music * Series, the ordered sets used i ...
capacitor In electrical engineering, a capacitor is a device that stores electrical energy by accumulating electric charges on two closely spaced surfaces that are insulated from each other. The capacitor was originally known as the condenser, a term st ...
s). ** ''shunt capacitors'' are used in power systems since the 1910s and are popular due to low cost and relative ease of deployment. The amount of reactive power supplied by a shunt capacitor is proportional to the square of the line voltage, so the capacitor contributes less under low-voltage conditions (frequently caused by the lack of reactive power). This is a serious drawback, as the supply of reactive power by a capacitor drops when it is most needed; ** ''series capacitors'' are used to compensate for the inductive reactance of the loaded overhead power lines. These devices, connected in series to the power conductors are typically used to lower the reactive power losses and to increase the amount of active power that can be transmitted through the line, with the supply of reactive power with self-regulation (the supply fortuitously increases with higher load) being the secondary consideration; The voltage across a series capacitor is typically low (within the regulation range of the network, few percent of the rated voltage), so its construction is relatively low-cost. However, in the case of a short on the load side, the capacitor will be briefly exposed to the full line voltage, thus protection circuits are provisioned, usually involving
spark gap A spark gap consists of an arrangement of two Conductor (material), conducting electrodes separated by a gap usually filled with a gas such as air, designed to allow an electric spark to pass between the conductors. When the potential differenc ...
s, ZnO
varistor A varistor (a.k.a. voltage-dependent resistor (VDR)) is a surge protecting electronic component with an electrical resistance that varies with the applied voltage. It has a nonlinear, non- ohmic current–voltage characteristic that is similar ...
s, and switches; * active compensators (e.g.,
synchronous condenser In electrical engineering, a synchronous condenser (sometimes called a syncon, synchronous capacitor or synchronous compensator) is a DC-excited synchronous motor, whose shaft is not connected to anything but spins freely. Its purpose is not to c ...
s,
static var compensator In electrical engineering, a static VAR compensator (SVC) is a set of electrical devices for providing fast-acting reactive power on high-voltage electric power transmission, electricity transmission networks. SVCs are part of the flexible AC trans ...
s,
static synchronous compensator In electrical engineering , a static synchronous compensator (STATCOM) is a shunt-connected, voltage control and reactive power management, reactive compensation device used on transmission networks. It uses power electronics to form a voltage-sour ...
s that can be either sources or sinks of reactive power; * regulating transformers (e.g., tap-changing transformers). The passive compensation devices can be permanently attached, or are switched (connected and disconnected) either manually, using a timer, or automatically based on sensor data. The active devices are by nature self-adjusting. The tap-changing transformers with under-load tap-changing (ULTC) feature can be used to control the voltage directly. The operation of all tap-changing transformers in the system needs to be synchronized between the transformers and with the application of shunt capacitors. Due to the localized nature of reactive power balance, the standard approach is to manage the reactive power locally (decentralized method). The proliferation of
microgrid A microgrid is a local electrical grid with defined electrical boundaries, acting as a single and controllable entity. It is able to operate in grid-connected and off-grid modes.
s might make the flexible centralized approach more economical.


Reactive power reserves

The system should be capable of providing additional amounts of reactive power very quickly (''dynamic requirement'') since a single failure of a generator or a transmission line (that has to be planned for) has the potential to immediately increase the load on some of the remaining transmission lines. The nature of
overhead power line An overhead power line is a structure used in electric power transmission and distribution to transmit electrical energy along large distances. It consists of one or more conductors (commonly multiples of three) suspended by towers or poles. ...
s is that as the load increases, the lines start consuming an increasing amount of reactive power that needs to be replaced. Thus a large transmission system requires reactive power reserves just like it needs reserves for the real power. Since the reactive power does not travel over the wires as well as the real power, there is an incentive to concentrate its production close to the load. Restructuring of electric power systems takes this area of the power grid out of hands of the integrated power utility, so the trend is to push the problem onto the customer and require the load to operate with a near-unity
power factor In electrical engineering, the power factor of an AC power system is defined as the ratio of the ''real power'' absorbed by the electrical load, load to the ''apparent power'' flowing in the circuit. Real power is the average of the instantaneou ...
.


See also

* Active Network Management


References


Sources

* * * * {{Electricity delivery Electric power transmission