Mineral-insulated copper-clad cable is a variety of
electrical cable Electricity is the set of physical phenomena associated with the presence and motion of matter possessing an electric charge. Electricity is related to magnetism, both being part of the phenomenon of electromagnetism, as described by Maxwel ...
made from copper conductors inside a copper sheath, insulated by inorganic
magnesium oxide Magnesium oxide (MgO), or magnesia, is a white hygroscopic solid mineral that occurs naturally as periclase and is a source of magnesium (see also oxide). It has an empirical formula of MgO and consists of a lattice of Mg2+ ions and O2− ions ...
powder. The name is often abbreviated to MICC or MI cable, and colloquially known as pyro (because the original manufacturer and vendor for this product in the UK was a company called Pyrotenax). A similar product sheathed with metals other than copper is called ''mineral-insulated metal-sheathed'' (MIMS) cable.


Construction

MI cable is made by placing copper rods inside a circular copper tube and filling the spaces with dry
magnesium oxide Magnesium oxide (MgO), or magnesia, is a white hygroscopic solid mineral that occurs naturally as periclase and is a source of magnesium (see also oxide). It has an empirical formula of MgO and consists of a lattice of Mg2+ ions and O2− ions ...
powder. The overall assembly is then pressed between rollers to reduce its diameter (and increase its length). Up to seven conductors are often found in an MI cable, with up to 19 available from some manufacturers. Since MI cables use no organic material as insulation (except at the ends), they are more resistant to fires than plastic-insulated cables. MI cables are used in critical
fire protection Fire protection is the study and practice of mitigating the unwanted effects of potentially Conflagration, destructive fires. It involves the study of the behaviour, Compartmentalization (fire protection), compartmentalisation, suppression and inve ...
applications such as alarm circuits, fire pumps, and smoke control systems. In process industries handling flammable fluids MI cable is used where small fires would otherwise cause damage to control or power cables. MI cable is also highly resistant to ionizing
radiation In physics, radiation is the emission or transmission of energy in the form of waves or particles through space or a material medium. This includes: * ''electromagnetic radiation'' consisting of photons, such as radio waves, microwaves, infr ...
and so finds applications in instrumentation for
nuclear reactors A nuclear reactor is a device used to initiate and control a fission nuclear chain reaction. They are used for commercial electricity, marine propulsion, weapons production and research. Fissile nuclei (primarily uranium-235 or plutonium-2 ...
and nuclear physics apparatus. MI cables may be covered with a plastic sheath, coloured for identification purposes. The plastic sheath also provides additional corrosion protection for the copper sheath. The metal tube shields the conductors from electromagnetic interference. The metal sheath also physically protects the conductors, most importantly from accidental contact with other energised conductors.


History

The first patent for MI cable was issued to the Swiss inventor Arnold Francois Borel in 1896. Initially the insulating mineral was described in the patent application as pulverised glass, silicious stones, or
asbestos Asbestos ( ) is a group of naturally occurring, Toxicity, toxic, carcinogenic and fibrous silicate minerals. There are six types, all of which are composed of long and thin fibrous Crystal habit, crystals, each fibre (particulate with length su ...
, in powdered form. Much development ensued by the French company Société Alsacienne de Construction Mécanique. Commercial production began in 1932 and much mineral-insulated cable was used on ships such as the Normandie and
oil tanker An oil tanker, also known as a petroleum tanker, is a ship designed for the bulk cargo, bulk transport of petroleum, oil or its products. There are two basic types of oil tankers: crude tankers and product tankers. Crude tankers move large quant ...
s, and in such critical applications as the
Louvre The Louvre ( ), or the Louvre Museum ( ), is a national art museum in Paris, France, and one of the most famous museums in the world. It is located on the Rive Droite, Right Bank of the Seine in the city's 1st arrondissement of Paris, 1st arron ...
museum. In 1937 a British company ''Pyrotenax'', having purchased patent rights to the product from the French company, began production. During the
Second World War World War II or the Second World War (1 September 1939 – 2 September 1945) was a World war, global conflict between two coalitions: the Allies of World War II, Allies and the Axis powers. World War II by country, Nearly all of the wo ...
much of the company's product was used in military equipment. The company floated on the stock exchange in 1954. Around 1947, the British Cable Makers' Association investigated the option of manufacturing a mineral-insulated cable that would compete with the Pyrotenax product. The manufacturers of the products "Bicalmin" and "Glomin" eventually merged with the Pyrotenax company. The Pyrotenax company introduced an aluminum sheathed version of its product in 1964. MI cable is now manufactured in several countries. Pyrotenax is now a brand name under nVent (formerly known as
Pentair Pentair plc (PNR) is an American water treatment company incorporated in Ireland with tax residency in UK, with its main U.S. office in Golden Valley, Minnesota, Golden Valley, Minnesota. Pentair was founded in the US, with 65% of company's reve ...
Thermal Management).


Purpose and use

MI cables are used for power and control circuits of critical equipment, such as the following examples: *
Nuclear reactor A nuclear reactor is a device used to initiate and control a Nuclear fission, fission nuclear chain reaction. They are used for Nuclear power, commercial electricity, nuclear marine propulsion, marine propulsion, Weapons-grade plutonium, weapons ...
s * Exposure to dangerous gasses * Air pressurisation systems for stairwells to enable building egress during a fire * Hospital operating rooms *
Fire alarm A fire alarm system is a building system designed to detect, alert occupants, and alert emergency forces of the presence of fire, smoke, carbon monoxide, or other fire-related emergencies. Fire alarm systems are required in most commercial buil ...
systems * Emergency power systems * Emergency lighting systems * Temperature measurement devices; RTDs and
thermocouple A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction. A thermocouple produces a temperature-dependent voltage as a result of the ...
s. * Critical process valves in the
petrochemical industry file:Jampilen Petrochemical Co. 02.jpg, 300px, Jampilen Petrochemical co., Asaluyeh, Iran The petrochemical industry is concerned with the production and trade of petrochemicals. A major part is constituted by the plastics industry, plastics (poly ...
* Public buildings such as theatres, cinemas, hotels * Transport hubs (
railway station Rail transport (also known as train transport) is a means of transport using wheeled vehicles running in railway track, tracks, which usually consist of two parallel steel railway track, rails. Rail transport is one of the two primary means of ...
s,
airport An airport is an aerodrome with extended facilities, mostly for commercial Aviation, air transport. They usually consist of a landing area, which comprises an aerially accessible open space including at least one operationally active surf ...
s etc.) * Mains supply cables within residential apartment blocks *
Tunnel A tunnel is an underground or undersea passageway. It is dug through surrounding soil, earth or rock, or laid under water, and is usually completely enclosed except for the two portals common at each end, though there may be access and ve ...
s and mines *
Electrical equipment in hazardous areas In electrical engineering, electrical and safety engineering, safety engineering, hazardous locations (HazLoc, pronounced ''haz·lōk'') are places where fire or explosion hazards may exist. Sources of such hazards include gases, vapors, dust e ...
where
flammable A combustible material is a material that can burn (i.e., sustain a flame) in air under certain conditions. A material is flammable if it ignites easily at ambient temperatures. In other words, a combustible material ignites with some effort ...
gas Gas is a state of matter that has neither a fixed volume nor a fixed shape and is a compressible fluid. A ''pure gas'' is made up of individual atoms (e.g. a noble gas like neon) or molecules of either a single type of atom ( elements such as ...
es may be present e.g.
oil refineries An oil refinery or petroleum refinery is an industrial process plant where petroleum (crude oil) is transformed and refined into products such as gasoline (petrol), diesel fuel, asphalt base, fuel oils, heating oil, kerosene, liquefied pet ...
,
petrol station A filling station (also known as a gas station [] or petrol station []) is a facility that sells fuel and engine lubricants for motor vehicles. The most common fuels sold are gasoline (or petrol) and diesel fuel. Fuel dispensers are used to ...
s * Areas where corrosive
chemical A chemical substance is a unique form of matter with constant chemical composition and characteristic properties. Chemical substances may take the form of a single element or chemical compounds. If two or more chemical substances can be combin ...
s may be present e.g.
factories A factory, manufacturing plant or production plant is an industrial facility, often a complex consisting of several buildings filled with machinery, where workers manufacture items or operate machines which process each item into another. Th ...
* Building
plant Plants are the eukaryotes that form the Kingdom (biology), kingdom Plantae; they are predominantly Photosynthesis, photosynthetic. This means that they obtain their energy from sunlight, using chloroplasts derived from endosymbiosis with c ...
rooms * Hot areas e.g.
power station A power station, also referred to as a power plant and sometimes generating station or generating plant, is an industrial facility for the electricity generation, generation of electric power. Power stations are generally connected to an electr ...
s,
foundries A foundry is a factory that produces metal castings. Metals are cast into shapes by melting them into a liquid, pouring the metal into a mold, and removing the mold material after the metal has solidified as it cools. The most common metals pr ...
, and close to or even inside industrial furnaces,
kiln A kiln is a thermally insulated chamber, a type of oven, that produces temperatures sufficient to complete some process, such as hardening, drying, or Chemical Changes, chemical changes. Kilns have been used for millennia to turn objects m ...
s and
oven upA double oven A ceramic oven An oven is a tool that is used to expose materials to a hot environment. Ovens contain a hollow chamber and provide a means of heating the chamber in a controlled way. In use since antiquity, they have been use ...
s MI cable fulfills the
passive fire protection Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. Examples of passive systems include floor- ...
called circuit integrity, which is intended to provide operability of critical electrical circuits during a fire. It is subject to strict
listing and approval use and compliance A certification Listing and approval use and compliance, listing is a document used to guide installations of Certification, certified products, against which a field installation is Installation testing, compared to make sure that it complies wit ...


Heating cable

A similar-appearing product is mineral-insulated
trace heating Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels using heat tracing cables. Trace heating takes the form of an electrical heating element run in physical contact alo ...
cable, in which the conductors are made of a high-resistance alloy. A heating cable is used to protect pipes from freezing or to maintain the temperature of process piping and vessels. An MI resistance heating cable may not be repairable if damaged. Most electric stove and oven heating elements are constructed in a similar manner.


Typical specifications


Properties and comparison with other wiring systems

The construction of MI cable makes it mechanically robust and resistant to impact.
Copper sheathing Copper sheathing is a method for protecting the hull of a wooden vessel from attack by shipworm, barnacles and other marine growth through the use of copper plates affixed to the surface of the hull, below the waterline. It was pioneered and d ...
is waterproof and resistant to ultraviolet light and many corrosive elements. MI cable is approved for use in areas with hazardous concentrations of flammable substances, being unlikely to initiate an explosion even during circuit fault conditions. MI cable is smokeless, non-toxic, and will not support combustion. The cable meets and exceeds BS 5839-1, making it fire-rated surpassing 950°c for over three hours with simultaneous mechanical stress and water spray as well without failure. MI cable is primarily used for high-temperature environments or safety-critical signal and power systems; however, it can additionally be used within a tenanted area, carrying electricity supplied and billed to the landlord. For example, for a communal extract system or antenna booster, it provides a supply cable that cannot easily be 'tapped' into to obtain free energy. The finished cable assembly can be bent to follow the shapes of buildings or bent around obstacles, allowing for a neat appearance when exposed. Since the inorganic insulation does not degrade with (moderate) heating, the finished cable assembly can be allowed to rise to higher temperatures than plastic-insulated cables; the limits to temperature rise may be only due to possible contact of the sheath with people or structures or the physical melting point of copper. This may also allow a smaller cross-section cable to be used in particular applications. An additional advantage of Mi cable is the ability to use the copper shield as a neutral or earth in particular situations Due to
oxidation Redox ( , , reduction–oxidation or oxidation–reduction) is a type of chemical reaction in which the oxidation states of the reactants change. Oxidation is the loss of electrons or an increase in the oxidation state, while reduction is ...
, the copper cladding darkens with age. However, where MICC cables with a bare copper sheath are installed in damp locations, particularly where lime mortar has been used, the water and lime combine to create an electrolytic action with the bare copper. Similarly, electrolytic action may also be caused by installing bare-sheath MICC cables on new oak. The reaction causes the copper to be eaten away, making a hole in the sheath of the cable and letting in water, causing a breakdown of the insulation and short circuits. The copper sheath material is typically resistant to most chemicals but can be severely damaged by ammonia-bearing compounds and
urine Urine is a liquid by-product of metabolism in humans and many other animals. In placental mammals, urine flows from the Kidney (vertebrates), kidneys through the ureters to the urinary bladder and exits the urethra through the penile meatus (mal ...
. A pinhole in the copper sheathing will allow moisture into the insulation and cause eventual failure of the circuit. A PVC over-jacket or sheaths of other metals may be required where such chemical damage is expected. When MI cable is embedded in concrete, as in floor heating cable, it is susceptible to physical damage by concrete workers working the concrete into the pour. If the coating is damaged, pinholes in the copper jacket may develop, causing premature failure of the system. While the length of the MI cable is very tough, at some point, each run of cabling terminates at a splice or within electrical equipment. These terminations are vulnerable to fire, moisture, and mechanical impact. MICC is not suitable for use where it will be subject to
vibration Vibration () is a mechanical phenomenon whereby oscillations occur about an equilibrium point. Vibration may be deterministic if the oscillations can be characterised precisely (e.g. the periodic motion of a pendulum), or random if the os ...
or flexing, as in connections to heavy or movable machinery. Vibration can cause cracking in the cladding and cores, leading to failure. During installation MI cable must not be bent repeatedly, as this will cause
work hardening Work hardening, also known as strain hardening, is the process by which a material's load-bearing capacity (strength) increases during plastic (permanent) deformation. This characteristic is what sets ductile materials apart from brittle materi ...
and cracks in the cladding and cores. A minimum bend radius must be observed, and the cable must be supported at regular intervals. The magnesium oxide insulation is
hygroscopic Hygroscopy is the phenomenon of attracting and holding water molecules via either absorption (chemistry), absorption or adsorption from the surrounding Natural environment, environment, which is usually at normal or room temperature. If water mol ...
, so MICC cable must be protected from moisture until it has been terminated. Termination requires stripping back the copper cladding and attaching a compression gland fitting. Individual conductors are insulated with plastic sleeves. A sealing tape, insulating putty, or an
epoxy resin Epoxy is the family of basic components or cured end products of epoxy resins. Epoxy resins, also known as polyepoxides, are a class of reactive prepolymers and polymers which contain epoxide groups. The epoxide functional group is also co ...
is then poured into the compression gland fitting to provide a watertight seal. If a termination is faulty due to workmanship or damage, then the magnesium oxide will absorb moisture and lose its insulating properties. Installation of MI cable takes more time than installation of a PVC-sheathed armoured cable of the same conductor size.R.S. Means Co, ''Electrical Cost Data 22nd Annual Edition'', 1999, Installation of MICC is therefore a costly task. MI cable is only manufactured with ratings up to 1000 volts. The magnesium oxide insulation has a high affinity for moisture. Moisture introduced into the cable can cause electrical leakage from the internal conductors to the metal sheath. Moisture absorbed at a cut end of the cable may be driven off by heating the cable. If the MI cable jacket has been damaged, the magnesium oxide will wick moisture into the cable, and it will lose its insulating properties, causing shorts to the copper cladding and thence to earth. It is often necessary to remove of the MI cable and splice in a new section to accomplish the repair. Depending on the size and number of conductors, a single termination can be a large undertaking to repair.


Alternatives

Circuit integrity for conventional plastic-insulated cables requires additional measures to obtain a
fire-resistance rating A fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may entail other criteria, involving eviden ...
or to lower the
flammability A combustible material is a material that can burn (i.e., sustain a flame) in air under certain conditions. A material is flammable if it ignites easily at ambient temperatures. In other words, a combustible material ignites with some effort a ...
and
smoke Smoke is an aerosol (a suspension of airborne particulates and gases) emitted when a material undergoes combustion or pyrolysis, together with the quantity of air that is entrained or otherwise mixed into the mass. It is commonly an unwante ...
contributions to a minimum degree acceptable for certain types of construction. Sprayed-on coatings or flexible wraps cover the plastic insulation to protect it from flame and reduce its flame-spreading ability. However, since these coatings reduce the heat dissipation of the cables, often they must be rated for less current after application of fire-resistant coatings. This is called current capacity derating. It can be tested through the use of IEEE 848 Standard Procedure for the Determination of the Ampacity Derating of Fire-Protected Cables.


See also

*
Listing and approval use and compliance A certification Listing and approval use and compliance, listing is a document used to guide installations of Certification, certified products, against which a field installation is Installation testing, compared to make sure that it complies wit ...
*
Passive fire protection Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. Examples of passive systems include floor- ...
* Circuit integrity *
Fireproofing Fireproofing is rendering something (Building, structures, materials, etc.) resistant to fire, or incombustible; or material for use in making anything fire-proof. It is a passive fire protection measure. "Fireproof" or "fireproofing" can be u ...
*
Cable tray In the electrical wiring of buildings, a cable tray system is used to support insulated electrical cables used for power distribution, control, and communication. Cable trays are used as an alternative to open wiring or electrical conduit system ...
*
Copper wire and cable Copper has been used in electrical wiring since the invention of the electromagnet and the telegraph in the 1820s. The invention of the telephone in 1876 created further demand for copper wire as an electrical conductor. Copper is the electri ...