Imaging particle analysis is a technique for making particle measurements using
digital imaging
Digital imaging or digital image acquisition is the creation of a digital representation of the visual characteristics of an object, such as a physical scene or the interior structure of an object. The term is often assumed to imply or include ...
, one of the techniques defined by the broader term
particle size analysis
Particle size analysis, particle size measurement, or simply particle sizing, is the collective name of the technical procedures, or laboratory techniques which determines the size range, and/or the average, or mean size of the particles in a po ...
. The measurements that can be made include
particle size
Particle size is a notion introduced for comparing dimensions of solid particles ('' flecks''), liquid particles ('' droplets''), or gaseous particles (''bubbles''). The notion of particle size applies to particles in colloids, in ecology, in ...
, particle shape (morphology or
shape analysis and
grayscale
In digital photography, computer-generated imagery, and colorimetry, a grayscale image is one in which the value of each pixel is a single sample representing only an ''amount'' of light; that is, it carries only intensity information. Graysc ...
or
color
Color (American English) or colour (British English) is the visual perceptual property deriving from the spectrum of light interacting with the photoreceptor cells of the eyes. Color categories and physical specifications of color are assoc ...
, as well as distributions (graphs) of
statistical population
In statistics, a population is a set of similar items or events which is of interest for some question or experiment. A statistical population can be a group of existing objects (e.g. the set of all stars within the Milky Way galaxy) or a hypot ...
measurements.
Description and history
Imaging particle analysis uses the techniques common to
image analysis
Image analysis or imagery analysis is the extraction of meaningful information from images; mainly from digital images by means of digital image processing techniques. Image analysis tasks can be as simple as reading bar coded tags or as sophi ...
or
image processing
An image is a visual representation of something. It can be two-dimensional, three-dimensional, or somehow otherwise feed into the visual system to convey information. An image can be an artifact, such as a photograph or other two-dimension ...
for the analysis of particles. Particles are defined here per
particle size analysis
Particle size analysis, particle size measurement, or simply particle sizing, is the collective name of the technical procedures, or laboratory techniques which determines the size range, and/or the average, or mean size of the particles in a po ...
as particulate solids, and thereby not including atomic or sub-atomic particles. Furthermore, this article is limited to
real image
{{citations needed, date=June 2019
In optics, an ''image'' is defined as the collection of focus points of light rays coming from an object. A real image is the collection of focus points actually made by converging/diverging rays, while a ...
s (optically formed), as opposed to "synthetic" (computed) images (
computed tomography
A computed tomography scan (CT scan; formerly called computed axial tomography scan or CAT scan) is a medical imaging technique used to obtain detailed internal images of the body. The personnel that perform CT scans are called radiographers ...
,
confocal microscopy
Confocal microscopy, most frequently confocal laser scanning microscopy (CLSM) or laser confocal scanning microscopy (LCSM), is an optical imaging technique for increasing optical resolution and contrast of a micrograph by means of using a s ...
, SIM and other
super resolution microscopy
Super-resolution microscopy is a series of techniques in optical microscopy that allow such images to have resolutions higher than those imposed by the diffraction limit, which is due to the diffraction of light. Super-resolution imaging techn ...
techniques, etc.).
Given the above, the primary method for imaging particle analysis is using optical microscopy. While
optical microscope
The optical microscope, also referred to as a light microscope, is a type of microscope that commonly uses visible light and a system of lenses to generate magnified images of small objects. Optical microscopes are the oldest design of micros ...
s have been around and used for particle analysis since the 1600s,
the "analysis" in the past has been accomplished by humans using the human
visual system
The visual system comprises the sensory organ (the eye) and parts of the central nervous system (the retina containing photoreceptor cells, the optic nerve, the optic tract and the visual cortex) which gives organisms the sense of sight ...
. As such, much of this analysis is subjective, or qualitative in nature. Even when some sort of qualitative tools are available, such as a measuring
reticle
A reticle, or reticule also known as a graticule, is a pattern of fine lines or markings built into the eyepiece of an optical device such as a telescopic sight, spotting scope, theodolite, optical microscope or the screen of an oscillos ...
in the microscope, it has still required a human to determine and record those measurements.
Beginning in the late 1800s
with the availability of
photographic plate
Photographic plates preceded photographic film as a capture medium in photography, and were still used in some communities up until the late 20th century. The light-sensitive emulsion of silver salts was coated on a glass plate, typically thi ...
s, it became possible to capture microscope images permanently on film or paper, making measurements easier to acquire by simply using a scaled ruler on the hard copy image. While this significantly speeded up the acquisition of particle measurements, it was still a tedious, labor-intensive process, which not only made it difficult to measure statistically significant particle populations, but also still introduced some degree of human error to the process.
Finally, beginning roughly in the late 1970s,
CCD digital sensors for capturing images and computers which could process those images, began to revolutionize the process by using
digital imaging
Digital imaging or digital image acquisition is the creation of a digital representation of the visual characteristics of an object, such as a physical scene or the interior structure of an object. The term is often assumed to imply or include ...
. Although the actual algorithms for performing
digital image processing
Digital image processing is the use of a digital computer to process digital images through an algorithm. As a subcategory or field of digital signal processing, digital image processing has many advantages over analog image processing. It allow ...
had been around for some time, it was not until the significant computing power needed to perform these analyses became available at reasonable prices that digital imaging techniques could be brought to bear in the mainstream. The first dynamic imaging particle analysis system was patented in 1982.
As faster computing resources became available at lowered costs, the task of making measurements from microscope images of particles could now be performed automatically by machine without human intervention, making it possible to measure significantly larger numbers of particles in much less time.
Image acquisition methods
The basic process by which imaging particle analysis is carried out is as follows:
# A digital camera captures an image of the
field of view
The field of view (FoV) is the extent of the observable world that is seen at any given moment. In the case of optical instruments or sensors it is a solid angle through which a detector is sensitive to electromagnetic radiation.
Humans a ...
in the optical system.
# A gray scale
thresholding process is used to perform
image segmentation
In digital image processing and computer vision, image segmentation is the process of partitioning a digital image into multiple image segments, also known as image regions or image objects ( sets of pixels). The goal of segmentation is to simpl ...
, segregating out the particles from the background, creating a
binary image
A binary image is one that consists of pixels that can have one of exactly two colors, usually black and white. Binary images are also called ''bi-level'' or ''two-level'', Pixelart made of two colours is often referred to as ''1-Bit'' or ''1b ...
of each particle.
#
Digital image processing
Digital image processing is the use of a digital computer to process digital images through an algorithm. As a subcategory or field of digital signal processing, digital image processing has many advantages over analog image processing. It allow ...
techniques are used to perform
image analysis
Image analysis or imagery analysis is the extraction of meaningful information from images; mainly from digital images by means of digital image processing techniques. Image analysis tasks can be as simple as reading bar coded tags or as sophi ...
operations, resulting in morphological and grey-scale measurements to be stored for each particle.
# The measurements saved for each particle are then used to generate image population statistics, or as inputs to algorithms for filtering and sorting the particles into groups of similar types. In some systems, sophisticated
pattern recognition
Pattern recognition is the automated recognition of patterns and regularities in data. It has applications in statistical data analysis, signal processing, image analysis, information retrieval, bioinformatics, data compression, computer graphic ...
techniques
may also be employed in order to separate different particle types contained in a heterogeneous sample.
Imaging particle analyzers can be subdivided into two distinct types, static and dynamic, based upon the image acquisition methods. While the basic principles are the same, the methods of image acquisition are different in nature, and each has advantages and disadvantages.
Static imaging particle analysis
Static image acquisition is the most common form. Almost all microscopes can be easily adapted to accept a digital camera via a
C mount
A C mount is a type of lens mount commonly found on 16 mm movie cameras, closed-circuit television cameras, machine vision cameras and microscope phototubes.
C-mount lenses provide a male thread, which mates with a female thread on the camera. ...
adaptor. This type of set-up is often referred to as a
digital microscope
A digital microscope is a variation of a traditional optical microscope that uses optics and a digital camera to output an image to a monitor, sometimes by means of software running on a computer. A digital microscope often has its own in-built ...
, although many systems using that name are used only for displaying an image on a
monitor
Monitor or monitor may refer to:
Places
* Monitor, Alberta
* Monitor, Indiana, town in the United States
* Monitor, Kentucky
* Monitor, Oregon, unincorporated community in the United States
* Monitor, Washington
* Monitor, Logan County, West ...
.
The sample is prepared on a microscope slide which is placed on the
microscope stage
A microscope () is a laboratory instrument used to examine objects that are too small to be seen by the naked eye. Microscopy is the science of investigating small objects and structures using a microscope. Microscopic means being invisib ...
. Once the sample has been focused on, then an image can be acquired and displayed on the monitor. If it is a
digital camera
A digital camera is a camera that captures photographs in digital memory. Most cameras produced today are digital, largely replacing those that capture images on photographic film. Digital cameras are now widely incorporated into mobile devic ...
or a
frame grabber
A frame grabber is an electronic device that captures (i.e., "grabs") individual, digital still frames from an analog video signal or a digital video stream. It is usually employed as a component of a computer vision system, in which video frame ...
is present, the image can now be saved in digital format, and image processing algorithms can be used to isolate particles in the field of view and measure them.
In static image acquisition only one field of view image is captured at a time. If the user wishes to image other portions of the same sample on the slide, they can use the X-Y positioning hardware (typically composed of two
linear stage
A linear stage or translation stage is a component of a precise motion system used to restrict an object to a single axis of motion. The term linear slide is often used interchangeably with "linear stage", though technically "linear slide" refe ...
s on the microscope to move to a different area of the slide. Care must be taken to insure that two images do not overlap so as not to count and measure the same particles more than once.
The major drawback to static image acquisition is that it is time consuming, both in sample preparation (getting the sample onto the slide with proper dilution if necessary), and in multiple movements of the stage in order to be able to acquire a statistically significant number of particles to count/measure. Computer-controlled X-Y positioning stages are sometimes used in these systems to speed the process up and to reduce the amount of operator intervention, but it is still a time consuming process, and the motorized stages can be expensive due to the level of precision required when working at high magnification.
The major advantages to static particle imaging systems are the use of standard microscope systems and simplicity of
depth of field
The depth of field (DOF) is the distance between the nearest and the furthest objects that are in acceptably sharp focus in an image captured with a camera.
Factors affecting depth of field
For cameras that can only focus on one object di ...
considerations. Since these systems can be made from any standard optical microscope, they may be a lower cost approach for people who already have microscopes. More important, though, is that microscope-based systems have less depth of field issues generally versus dynamic imaging systems. This is because the sample is placed on a microscope slide, and then usually covered with a
cover slip
A microscope slide is a thin flat piece of glass, typically 75 by 26 mm (3 by 1 inches) and about 1 mm thick, used to hold objects for examination under a microscope. Typically the object is mounted (secured) on the slide, and the ...
, thus limiting the plane containing the particles relative to the
optical axis
An optical axis is a line along which there is some degree of rotational symmetry in an optical system such as a camera lens, microscope or telescopic sight.
The optical axis is an imaginary line that defines the path along which light propagat ...
. This means that more particles will be in acceptable focus at high magnifications.
Dynamic imaging particle analysis

In Dynamic image acquisition, large amounts of sample are imaged by moving the sample past the microscope optics and using
high speed flash illumination to effectively "freeze" the motion of the sample. The flash is
synchronized with a high
shutter speed
In photography, shutter speed or exposure time is the length of time that the film or digital sensor inside the camera is exposed to light (that is, when the camera's shutter (photography), shutter is open) when taking a photograph.
The am ...
in the camera to further prevent motion blur. In a dry particle system, the particles are dispensed from a shaker table and fall by gravity past the optical system. In fluid imaging particle analysis systems, the liquid is passed across the optical axis by use of a narrow flow cell as shown at right.

The flow cell is characterized by its depth perpendicular to the optical axis, as shown in the second diagram on right. In order to keep the particles in focus, the flow depth is restricted so that the particles remain in a plane of best focus perpendicular to the optical axis. This is similar in concept to the effect of the microscope slide plus cover slip in a static imaging system. Since depth of field decreases exponentially with increasing magnification, the depth of the flow cell must be narrowed significantly with higher magnifications.
The major drawback to dynamic image acquisition is that the flow cell depth must be limited as described above. This means that, in general, particles larger in size than the flow cell depth can not be allowed in the sample being processed, because they will probably clog the system. So the sample will typically have to be filtered to remove particles larger than the flow cell depth prior to being evaluated. If it is desired to look at a very wide range of particle size, this may mean that the sample would have to be fractionated into smaller size range components, and run with different magnification/flow cell combinations.
The major advantage to dynamic image acquisition is that it enables acquiring and measuring particles at significantly higher speed, typically on the order of 10,000 particles/minute or greater. This means that statistically significant populations can be analyzed in far shorter time periods than previously possible with manual microscopy or even static imaging particle analysis. In this sense, dynamic imaging particle analysis systems combine the speed typical of
particle counter
A particle counter is used for monitoring and diagnosing particle contamination within specific clean media, including air, water and chemicals. Particle counters are used in a variety of applications in support of clean manufacturing practices, ...
s with the discriminatory capabilities of microscopy.
Dynamic imaging particle analysis is used in aquatic microorganism research to analyze phytoplankton, zooplankton, and other aquatic microorganisms ranging from 2 um to 5 mm in size. Dynamic imaging particle analysis is also biopharmaceutical research to characterize and analyze particles ranging from 300 nm to 5mm in size.
Micro-flow imaging
''Micro-flow imaging (MFI)'' is a particle analysis technique that uses flow
microscopy
Microscopy is the technical field of using microscopes to view objects and areas of objects that cannot be seen with the naked eye (objects that are not within the resolution range of the normal eye). There are three well-known branches of mi ...
to quantify particles contained in a solution based on size. This technique is used in the
biopharmaceutical
A biopharmaceutical, also known as a biological medical product, or biologic, is any pharmaceutical drug product manufactured in, extracted from, or semisynthesized from biological sources. Different from totally synthesized pharmaceuticals, t ...
industry to characterize subvisible particles from approximately 1 μm to >50 μm.
References
{{Reflist
Laboratory equipment
Counting instruments
Microscopy