IEC 61334, known as Distribution automation using distribution line carrier systems, is a standard for low-speed reliable
power line communication Power-line communication (PLC) is the carrying of data on a conductor (the ''power-line carrier'') that is also used simultaneously for AC electric power transmission or electric power distribution to consumers. A wide range of power-line comm ...
s by
electricity meter file:Hydro quebec meter.JPG, North American domestic analog signal, analog (Galileo Ferraris, Ferraris disk) electricity meter. file:Transparent Electricity Meter found in Israel.JPG, Electricity meter with transparent plastic case (Israel) fil ...
s,
water meter Water metering is the practice of measuring water use. Water meters measure the volume of water used by residential and commercial building units that are supplied with water by a public water supply system. They are also used to determine Flui ...
s and
SCADA SCADA (an acronym for supervisory control and data acquisition) is a control system architecture comprising computers, networked data communications and graphical user interfaces for high-level supervision of machines and processes. It also cove ...
. It is also known as spread frequency-shift keying (S-FSK) and was formerly known as IEC 1334 before IEC's most recent renumbering. It is actually a series of standards describing the researched physical environment of power lines, a well-adapted physical layer, a workable low-power media access layer, and a management interface. Related standards use the physical layer (e.g.
Internet Protocol The Internet Protocol (IP) is the network layer communications protocol in the Internet protocol suite for relaying datagrams across network boundaries. Its routing function enables internetworking, and essentially establishes the Internet. IP ...
over S-FSK), but not the higher layers. The physical layer synchronizes a small packet of tones to the zero-crossing of the power line's voltage. The tones are chosen by utilities, not specified in the standard. Tones are usually between 20 kHz and 100 kHz, and should be separated by at least 10 kHz to prevent cross talk. One tone is chosen for mark (i.e. a
binary Binary may refer to: Science and technology Mathematics * Binary number, a representation of numbers using only two values (0 and 1) for each digit * Binary function, a function that takes two arguments * Binary operation, a mathematical op ...
1), and the other for space (i.e. 0). The standard permits each zero-crossing to convey 1, 2, 4 or 8 bits, with increased sensitivity to timing as the number of bits increases. In multiphase power lines, a separate signal might be sent on each phase to speed up the transmission. The standard's low speed is caused by the limited number of bits per power line cycle. The speed is also limited by noise, and the local jitter of the AC line's zero crossing. The high reliability comes from its reliable timing system (i.e. zero crossing), high signal to noise ratio (frequencies are chosen to avoid common power line noise), lack of intermodulation distortion, and adaptive signal detection. The most significant bits are sent first, unlike a conventional
serial port A serial port is a serial communication Interface (computing), interface through which information transfers in or out sequentially one bit at a time. This is in contrast to a parallel port, which communicates multiple bits simultaneously in Pa ...
. The data from zero crossings should be collected into 8-bit bytes. Each byte is collected into 42-byte packets. The first four bytes of each packet are a preamble to measure the channel's current condition. This is followed by 38 bytes of data, and 3 byte-times of silence. S-FSK centers tones around the time when the AC line passes through zero voltage. In this way, the tones avoid most radio-frequency noise from arcing. (It is common for dirty insulators to arc at the highest point of the voltage, and thus generate a wide-band burst of noise.) Since tone pairs are chosen by utilities, different districts can use different tone pairs to avoid interference. To avoid other interference, receivers can improve their signal-to-noise ratio by adapting their decoder. The silence and the preamble allow the receiver's signal processing to measure the channel's noise ratios. Depending on the signal to noise ratios, the bits can be recovered from the difference between the power of the mark and space tones, the power of the mark tones only, or the space tones only. The system should be able to adjust the receiving method on each 42-byte packet. Bit timing is typically recovered from the boundaries of tones, much like a
UART A universal asynchronous receiver-transmitter (UART ) is a peripheral device for asynchronous serial communication in which the data format and transmission speeds are configurable. It sends data bits one by one, from the least significant to ...
that is triggered by a start bit. Timing is roughly centered on the zero crossing with a timer from the previous zero crossing that can enable the bit detection. Practical bit timing cannot be derived from the zero crossing alone, due to local jitter and noise in the zero crossing caused by varying local loads on the grid. The bytes from the low-layer packets are reformed into bytes for the higher layers. The higher link-layer strongly resembles
HDLC High-Level Data Link Control (HDLC) is a communication protocol used for transmitting data between devices in Telecommunications, telecommunication and Computer network, networking. Developed by the International Organization for Standardization ...
, except with a novel feature that allows selected stations to retransmit messages. The management interface layer provides remote control of a station's protocol layers, including diagnostics and configuration. For example, it lets a central controller read a unit's signal to noise ratios, and set the bit that enables a station to retransmit weak stations. The protocol layers are designed to integrate with any application layer, but the presence of a management interface suggests a design targeted to DLMS/COSEM, a widely used EU standard for the application layer of meters and SCADA. DLMS/COSEM requires a management interface.


Spread frequency-shift keying

S-FSK (spread frequency-shift keying) is a
modulation Signal modulation is the process of varying one or more properties of a periodic waveform in electronics and telecommunication for the purpose of transmitting information. The process encodes information in form of the modulation or message ...
scheme that combines some of the advantages of classical
spread-spectrum In telecommunications, especially radio communication, spread spectrum are techniques by which a signal (e.g., an electrical, electromagnetic, or acoustic) generated with a particular bandwidth is deliberately spread in the frequency domain o ...
modulation (immunity against narrow-band interference) with some of the advantages of classical
frequency-shift keying Frequency-shift keying (FSK) is a frequency modulation scheme in which digital information is encoded on a carrier signal by periodically shifting the frequency of the carrier between several discrete frequencies. The technology is used fo ...
(FSK is low complexity). The difference between S-FSK and classical FSK is that in S-FSK, the mark frequency f_m is placed far from the space frequency f_s. The frequencies are placed far enough apart that frequency-selective fading and narrow-band interference only blocks one of the frequencies, so the receiver can still recover all the data from the other frequency."Power Line Carrier Modem"
2014. p. 16


List of IEC 61334 parts

*IEC TR 61334-1-1:1995 General considerations – Distribution automation system architecture *IEC TR 61334-1-2:1997 General considerations – Guide for specification *IEC TR 61334-1-4:1995 General considerations – Identification of data transmission parameters concerning medium and low-voltage distribution mains *IEC 61334-3-1:1998 Mains signalling requirements – Frequency bands and output levels *IEC 61334-3-21:1996 Mains signalling requirements – MV phase-to-phase isolated capacitive coupling device *IEC 61334-3-22:2001 Mains signalling requirements – MV phase-to-earth and screen-to-earth intrusive coupling devices *IEC 61334-4-1:1996
Data communication Data communication, including data transmission and data reception, is the transfer of data, transmitted and received over a point-to-point or point-to-multipoint communication channel. Examples of such channels are copper wires, optic ...
protocols – Reference model of the communication system *IEC 61334-4-32:1996 Data communication protocols – Section 32: Data link layer – Logical link control (LLC) *IEC 61334-4-33:1998 Data communication protocols – Data link layer – Connection oriented protocol *IEC 61334-4-41:1996 Data communication protocols – Application protocols – Distribution line message specification *IEC 61334-4-42:1996 Data communication protocols – Application protocols – Application layer *IEC 61334-4-61:1998 Data communication protocols – Network layer – Connectionless protocol *IEC 61334-4-511:2000 Data communication protocols – Systems management – CIASE protocol *IEC 61334-4-512:2001 Data communication protocols – System management using profile 61334-5-1 – Management Information Base (MIB) *IEC 61334-5-1:2001 Lower layer profiles – The spread frequency shift keying (S-FSK) profile *IEC TS 61334-5-2:1998 Lower layer profiles – Frequency shift keying (FSK) profile *IEC TS 61334-5-3:2001 Lower-layer profiles – Spread spectrum adaptive wideband (SS-AW) profile *IEC TS 61334-5-4:2001 Lower layer profiles – Multi-carrier modulation (MCM) profile *IEC TS 61334-5-5:2001 Lower layer profiles – Spread spectrum – fast frequency hopping (SS-FFH) profile *IEC 61334-6:2000 A-XDR encoding rule


See also

*
Power line communication Power-line communication (PLC) is the carrying of data on a conductor (the ''power-line carrier'') that is also used simultaneously for AC electric power transmission or electric power distribution to consumers. A wide range of power-line comm ...
, for a survey of the topic * Universal powerline bus, the more common shorter-ranged competitor


References

{{List of IEC standards Networking standards