Gated SPECT is a
nuclear medicine Nuclear medicine (nuclear radiology, nucleology), is a medical specialty involving the application of radioactivity, radioactive substances in the diagnosis and treatment of disease. Nuclear imaging is, in a sense, ''radiology done inside out'', ...
imaging technique, typically for the
heart The heart is a muscular Organ (biology), organ found in humans and other animals. This organ pumps blood through the blood vessels. The heart and blood vessels together make the circulatory system. The pumped blood carries oxygen and nutrie ...
in myocardial perfusion imagery. An electrocardiogram (ECG) guides the image acquisition, and the resulting set of
single-photon emission computed tomography Single-photon emission computed tomography (SPECT, or less commonly, SPET) is a nuclear medicine tomography, tomographic imaging technique using gamma rays. It is very similar to conventional nuclear medicine planar imaging using a gamma camera ...
(SPECT) images shows the heart as it contracts over the interval from one R wave to the next. Gated myocardial perfusion imaging has been shown to have high prognostic value and sensitivity for critical
stenosis Stenosis () is the abnormal narrowing of a blood vessel or other tubular organ or structure such as foramina and canals. It is also sometimes called a stricture (as in urethral stricture). ''Stricture'' as a term is usually used when narrowing ...
. The acquisition computer defines the number of time bins or frames to divide the R to R interval of the patient's electrocardiogram. A "window" may be set which discards data from R to R intervals which deviate from some amount from the patient's average R to R wave duration. This discards preventricular contractions and
arrhythmia Arrhythmias, also known as cardiac arrhythmias, are irregularities in the cardiac cycle, heartbeat, including when it is too fast or too slow. Essentially, this is anything but normal sinus rhythm. A resting heart rate that is too fast – ab ...
s from the acquisition and improves the quality of the resulting study. The
gamma camera A gamma camera (γ-camera), also called a scintillation camera or Anger camera, is a device used to image gamma radiation emitting radioisotopes, a technique known as scintigraphy. The applications of scintigraphy include early drug development ...
will take a series of pictures around the patient, dividing each 'step' of the camera head's motion into the predetermined number of 'frames.' The details of this acquisition vary with single-headed, double-headed, or triple-headed cameras — but a single-headed camera typically acquires 32 'steps' over an arc of 180 degrees around the patient. When the acquisition is completed, the technologist must process the images to create a data set which represents the volume of tracer as seen by the camera during the study acquisition. In gated SPECT, this process is performed for each of the time bins defined by the acquisition protocol. When viewed by the physician for interpretation, the heart can be watched as it contracts and expands from
diastole Diastole ( ) is the relaxed phase of the cardiac cycle when the chambers of the heart are refilling with blood. The contrasting phase is systole when the heart chambers are contracting. Atrial diastole is the relaxing of the atria, and ventricul ...
to
systole Systole ( ) is the part of the cardiac cycle during which some chambers of the heart contract after refilling with blood. Its contrasting phase is diastole, the relaxed phase of the cardiac cycle when the chambers of the heart are refilling ...
. The computer can calculate the patient's
ejection fraction An ejection fraction (EF) is the volumetric fraction (or portion of the total) of fluid (usually blood) ejected from a chamber (usually the heart) with each contraction (or heartbeat). It can refer to the cardiac atrium, cardiac ventricle, gall ...
, end diastolic volume, wall motion, end systolic volume, myocardial thickening, shortening, and contractility. However, one is viewing an average of all collected heart beats over the image acquisition.
Noise Noise is sound, chiefly unwanted, unintentional, or harmful sound considered unpleasant, loud, or disruptive to mental or hearing faculties. From a physics standpoint, there is no distinction between noise and desired sound, as both are vibrat ...
on the ECG, patient motion, artefacts, or a change in the heart rate during acquisition can degrade the quality of the resulting gated image dataset.


References


Further reading

* * 3D nuclear medical imaging {{med-diagnostic-stub