An electrical conductivity meter (EC meter) measures the electrical conductivity in a solution. It has multiple applications in research and engineering, with common usage in
hydroponics Hydroponics is a type of horticulture and a subset of hydroculture which involves growing plants, usually crops or medicinal plants, without soil, by using water-based mineral nutrient solutions in aqueous solvents. Terrestrial or aquatic plant ...
, aquaculture,
aquaponics Aquaponics is a food production system that couples aquaculture (raising aquatic animals such as fish, crayfish, snails or prawns in tanks) with hydroponics (cultivating plants in water) whereby the nutrient-rich aquaculture water is fed to hydr ...
, and freshwater systems to monitor the amount of nutrients, salts or impurities in the water.


Principle

Common laboratory conductivity meters employ a
potentiometric A potentiometer is a three-terminal resistor with a sliding or rotating contact that forms an adjustable voltage divider. If only two terminals are used, one end and the wiper, it acts as a variable resistor or rheostat. The measuring instrum ...
method and four electrodes. Often, the electrodes are cylindrical and arranged concentrically. The electrodes are usually made of platinum metal. An alternating current is applied to the outer pair of the electrodes. The potential between the inner pair is measured. Conductivity could in principle be determined using the distance between the electrodes and their surface area using Ohm's law but generally, for accuracy, a calibration is employed using electrolytes of well-known conductivity. Industrial conductivity probes often employ an inductive method, which has the advantage that the fluid does not wet the electrical parts of the sensor. Here, two inductively-coupled coils are used. One is the driving coil producing a magnetic field and it is supplied with accurately-known voltage. The other forms a secondary coil of a transformer. The liquid passing through a channel in the sensor forms one turn in the secondary winding of the transformer. The induced current is the output of the sensor. Another way is to use four-electrode conductivity sensors that are made from corrosion-resistant materials. A benefit of four-electrode conductivity sensors compared to inductive sensors is scaling compensation and the ability to measure low (below 100 μS/cm) conductivities (a feature especially important when measuring near-100% hydrofluoric acid).


Temperature dependence

The conductivity of a solution is highly
temperature Temperature is a physical quantity that expresses quantitatively the perceptions of hotness and coldness. Temperature is measurement, measured with a thermometer. Thermometers are calibrated in various Conversion of units of temperature, temp ...
dependent, so it is important either to use a temperature compensated instrument, or to calibrate the instrument at the same temperature as the solution being measured. Unlike metals, the conductivity of common electrolytes typically increases with increasing temperature. Over a limited temperature range, the way temperature affects the conductivity ''of a solution'' can be modeled
linear Linearity is the property of a mathematical relationship ('' function'') that can be graphically represented as a straight line. Linearity is closely related to '' proportionality''. Examples in physics include rectilinear motion, the linear ...
ly using the following formula: :\sigma_T = where :''T'' is the temperature of the sample, :''Tcal'' is the calibration temperature, :''σT'' is the electrical conductivity at the temperature ''T'', :''σTcal'' is the electrical conductivity at the calibration temperature ''Tcal'', :''α'' is the temperature compensation gradient of the solution. The temperature compensation gradient for most naturally occurring samples of water is about 2%/C°; however it can range between 1 and 3%/C°. The compensation gradients for some common water solutions are listed in the table below.


Conductivity measurement applications

Conductivity measurement is a versatile tool in process control. The measurement is simple and fast, and most advanced sensors require only a little maintenance. The measured conductivity reading can be used to make various assumptions on what is happening in the process. In some cases it is possible to develop a model to calculate the concentration of the liquid. Concentration of pure liquids can be calculated when the conductivity and temperature is measured. The preset curves for various acids and bases are commercially available. For example, one can measure the concentration of high purity hydrofluoric acid using conductivity-based concentration measurement hejiang Quhua Fluorchemical, China Valmet Concentration 3300 A benefit of conductivity- and temperature-based concentration measurement is the superior speed of inline measurement compared to an on-line analyzer. Conductivity-based concentration measurement has limitations. The concentration-conductivity dependence of most acids and bases is not linear. Conductivity-based measurement cannot determine on which side of the peak the measurement is, and therefore the measurement is only possible on a linear section of the curve. Kraft pulp mills use conductivity-based concentration measurement to control alkali additions to various stages of the cook. Conductivity measurement will not determine the specific amount of alkali components, but it is a good indication on the amount of effective alkali (NaOH + Na2S as NaOH or Na2O) or active alkali (NaOH + Na2S as NaOH or Na2O) in the cooking liquor. The composition of the liquor varies between different stages of the cook. Therefore, it is necessary to develop a specific curve for each measurement point or to use commercially available products. The high pressure and temperature of cooking process, combined with high concentration of alkali components, put a heavy strain on conductivity sensors that are installed in process. The scaling on the electrodes needs to be taken into account, otherwise the conductivity measurement drifts, requiring increased calibration and maintenance.


See also

* Conductivity factor *
Salinometer A salinometer is a device designed to measure the salinity, or dissolved salt content, of a solution. Since the salinity affects both the electrical conductivity and the specific gravity of a solution, a salinometer often consist of an ec meter o ...
*
Total dissolved solids Total dissolved solids (TDS) is a measure of the dissolved combined content of all inorganic and organic substances present in a liquid in molecular, ionized, or micro-granular ( colloidal sol) suspended form. TDS concentrations are often report ...
* TDS meter


References


External links

{{commons category, Electrical conductivity meters * /Https://www.astm.org/d1125-14.html ASTM D1125-14 Standard Test Methods for Electrical Conductivity and Resistivity of Waterbr>ASTM D5682DIN 55667
Electrochemistry Measuring instruments