HOME

TheInfoList



OR:

The characteristic impedance or surge impedance (usually written Z0) of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line; that is, a wave travelling in one direction in the absence of reflections in the other direction. Alternatively, and equivalently, it can be defined as the input impedance of a transmission line when its length is infinite. Characteristic impedance is determined by the geometry and materials of the transmission line and, for a uniform line, is not dependent on its length. The SI unit of characteristic impedance is the ohm. The characteristic impedance of a lossless transmission line is purely real, with no reactive component. Energy supplied by a source at one end of such a line is transmitted through the line without being dissipated in the line itself. A transmission line of finite length (lossless or lossy) that is terminated at one end with an impedance equal to the characteristic impedance appears to the source like an infinitely long transmission line and produces no reflections.


Transmission line model

The characteristic impedance Z(\omega) of an infinite transmission line at a given angular frequency \omega is the ratio of the voltage and current of a pure sinusoidal wave of the same frequency travelling along the line. This relation is also the case for finite transmission lines until the wave reaches the end of the line. Generally, a wave is reflected back along the line in the opposite direction. When the reflected wave reaches the source, it is reflected yet again, adding to the transmitted wave and changing the ratio of the voltage and current at the input, causing the voltage-current ratio to no longer equal the characteristic impedance. This new ratio including the reflected energy is called the input impedance. The input impedance of an infinite line is equal to the characteristic impedance since the transmitted wave is never reflected back from the end. Equivalently: ''The characteristic impedance of a line is that impedance which, when terminating an arbitrary length of line at its output, produces an input impedance of equal value''. This is so because there is no reflection on a line terminated in its own characteristic impedance. Applying the transmission line model based on the telegrapher's equations as derived below, the general expression for the characteristic impedance of a transmission line is: :Z_\text = \sqrt where :R is the
resistance Resistance may refer to: Arts, entertainment, and media Comics * Either of two similarly named but otherwise unrelated comic book series, both published by Wildstorm: ** ''Resistance'' (comics), based on the video game of the same title ** ''T ...
per unit length, considering the two conductors to be
in series Two-terminal components and electrical networks can be connected in series or parallel. The resulting electrical network will have two terminals, and itself can participate in a series or parallel topology. Whether a two-terminal "object" is a ...
, :L is the
inductance Inductance is the tendency of an electrical conductor to oppose a change in the electric current flowing through it. The flow of electric current creates a magnetic field around the conductor. The field strength depends on the magnitude of the ...
per unit length, :G is the conductance of the dielectric per unit length, :C is the capacitance per unit length, :j is the imaginary unit, and :\omega is the angular frequency. This expression extends to DC by letting \omega tend to 0. A surge of energy on a finite transmission line will see an impedance of Z_\text prior to any reflections returning; hence ''surge impedance'' is an alternative name for ''characteristic impedance''. Although an infinite line is assumed, since all quantities are per unit length, the “per length” parts of all the units cancel, and the characteristic impedance is independent of the length of the transmission line. The voltage and current
phasor In physics and engineering, a phasor (a portmanteau of phase vector) is a complex number representing a sinusoidal function whose amplitude (''A''), angular frequency (''ω''), and initial phase (''θ'') are time-invariant. It is related to ...
s on the line are related by the characteristic impedance as: :\frac = Z_\text = -\frac where the subscripts (+) and (−) mark the separate constants for the waves traveling forward (+) and backward (−).


Derivation


Using telegrapher's equation

The differential equations describing the dependence of the voltage and current on time and space are linear, so that a linear combination of solutions is again a solution. This means that we can consider solutions with a time dependence \ e^\ – doing so is functionally equivalent of solving for the Fourier coefficients for voltage and current amplitudes at some fixed angular frequency \ \omega\ . Doing so causes the time dependence to factor out, leaving an ordinary differential equation for the coefficients, which will be
phasor In physics and engineering, a phasor (a portmanteau of phase vector) is a complex number representing a sinusoidal function whose amplitude (''A''), angular frequency (''ω''), and initial phase (''θ'') are time-invariant. It is related to ...
s, dependent on position (space) only. Moreover, the parameters can be generalized to be frequency-dependent. Let :\ V(x,t) \equiv V(x)\ e^\ and :\ I(x,t) \equiv I(x)\ e^\ Take the positive direction for V and I in the loop to be clockwise. We find that :\ \mathrmV = -(R + j \omega L)\ I\ \mathrmx = -Z'\ I\ \mathrmx\ and :\ \mathrmI = -(G + j \omega C)\ V\ \mathrmx = -Y'\ V\ \mathrmx\ or :\frac = -Z'\ I\qquad and \qquad\frac = -Y'\ V where :Z' \equiv R + j \omega L \qquad and \qquad Y' \equiv G + j \omega C ~. These two first-order equations are easily uncoupled by a second differentiation, with the results: :\frac = Z' Y'\ V and :\frac = Z' Y'\ I Notice that both V and I satisfy the same equation. Since \ Z' Y'\ is independent of x and t, it can be represented by a single constant (The minus sign is included for later convenience.) That is: :-k^2 \equiv Z'\ Y'\ so : j \ k = \pm \sqrt We can write the above equation as :\ k = \pm \omega \sqrt = \pm \omega\sqrt \sqrt which is correct for any transmission line in general. And for typical transmission lines, that are carefully built from wire with low loss resistance \ R\ and small insulation leakage conductance \ G\ ; further, used for high frequencies, the inductive reactance \ \omega L\ and the capacitive admittance \ \omega C\ will both be large, so the constant \ k\ is very close to being a real number: :k \approx \pm \omega \sqrt ~. With this definition of \ k\ , the position- or \ x\ -dependent part will appear as in the exponential solutions of the equation, similar to the time-dependent part so the solution reads :V(x) = v_\ e^ + v_ e^ where \ v_\ and \ v_\ are the
constants of integration In calculus, the constant of integration, often denoted by C (or c), is a constant term added to an antiderivative of a function f(x) to indicate that the indefinite integral of f(x) (i.e., the set of all antiderivatives of f(x)), on a connected ...
for the forward moving (+) and backward moving (−) waves, as in the prior section. When we recombine the time-dependent part we obtain the full solution: :\ V(x,t) ~ = ~ V(x)\ e^ ~ = ~ v_\ e^ + v_ e^\ . Since the equation for I is the same form, it has a solution of the same form: :\ I(x) = i_\ e^ + i_\ e^\ , where \ i_\ and \ i_\ are again
constants of integration In calculus, the constant of integration, often denoted by C (or c), is a constant term added to an antiderivative of a function f(x) to indicate that the indefinite integral of f(x) (i.e., the set of all antiderivatives of f(x)), on a connected ...
. The above equations are the wave solution for V and I. In order to be compatible, they must still satisfy the original differential equations, one of which is :\ \frac = -Z'\ I\ . Substituting the solutions for V and I into the above equation, we get :\ \frac\left v_\ e^ + v_\ e^ \right= -(R + j\omega L)\left i_\ e^ + i_\ e^ \right or :\ -j k\ v_\ e^ + j k\ v_\ e^ = -(R + j\omega L)\ i_\ e^ - (R + j\omega L)\ i_\ e^\ Isolating distinct powers of e and combining identical powers, we see that in order for the above equation to hold for all possible values of \ x\ we must have: :For the co-efficients of \ e^ \quad \text \quad -j\ k\ v_ = -(R + j\omega L)\ i_\ :For the co-efficients of \ e^ \quad \text \quad +j\ k \ v_ = -(R + j \omega L)\ i_\ Since \ j k = \sqrt\ :\ +\frac = \frac = \sqrt \equiv Z_\text\ :\ -\frac = \frac = \sqrt \equiv Z_\text\ hence, for valid solutions require :\ v_ = +Z_\text\ i_ \quad \text \quad v_ = -Z_\text\ i_\ It can be seen that the constant Z_\text, defined in the above equations has the dimensions of impedance (ratio of voltage to current) and is a function of primary constants of the line and operating frequency. It is called the “characteristic impedance” of the transmission line, and conventionally denoted by Z_\text. :\ Z_\text \quad = \quad \sqrt \quad = \quad \sqrt \sqrt\ which holds generally, for any transmission line. For well-functioning transmission lines, with either \ R\ and \ G\ both very small, or with \ \omega\ very high, or all of the above, we get :\ Z_\text \approx \sqrt\ hence the characteristic impedance is typically very close to being a real number. Manufacturers make commercial cables to approximate this condition very closely over a wide range of frequencies.


Alternative approach

We follow an approach posted by Tim Healy. The line is modeled by a series of differential segments with differential series \ \left( R\ \mathrmx, L\ \mathrmx \right)\ and shunt \ \left(C\ \mathrmx, G\ \mathrmx \right)\ elements (as shown in the figure above). The characteristic impedance is defined as the ratio of the input voltage to the input current of a semi-infinite length of line. We call this impedance \ Z_\mathrm\ . That is, the impedance looking into the line on the left is \ Z_\mathrm\ . But, of course, if we go down the line one differential length \mathrmx\ , the impedance into the line is still \ Z_\mathrm\ . Hence we can say that the impedance looking into the line on the far left is equal to \ Z_\mathrm\ in parallel with \ C\ \mathrmx\ and \ G\ \mathrmx\ , all of which is in series with \ R\ \mathrmx\ and \ L\ \mathrmx\ . Hence: :\ Z_\mathrm = (R + j \omega L)\ \mathrmx + \frac\ :\ Z_\mathrm = (R + j \omega L)\ \mathrmx + \frac\ :\ Z_\mathrm + Z_\mathrm^2\ (G + j \omega C)\ \mathrmx = (R + j \omega L)\ \mathrmx + Z_\mathrm\ (G + j \omega C)\ \mathrmx\ (R + j \omega L)\ \mathrmx + Z_\mathrm\ The added \ Z_\mathrm\ terms cancel, leaving :\ Z_\mathrm^2\ (G + j \omega C)\ \mathrmx = (R + j \omega L)\ \mathrmx + Z_\mathrm\ (G + j \omega C)\ (R + j \omega L)\ (\mathrmx)^2\ The first-power \ \mathrmx\ terms are the highest remaining order. Dividing out the common factor of \ \mathrmx\ , and dividing through by the factor \ (G + j \omega C)\ , we get :\ Z_\mathrm^2 = \frac + Z_\mathrm\ (R + j \omega L)\ (\mathrmx)\ . In comparison to the factors whose \ \mathrmx\ divided out, the last term, which still carries a remaining factor \ \mathrmx\ , is infinitesimal relative to the other, now finite terms, so we can drop it. That leads to :\ Z_\mathrm = \pm \sqrt\ . Reversing the sign applied to the square root has the effect of reversing the direction of the flow of current.


Lossless line

The analysis of lossless lines provides an accurate approximation for real transmission lines that simplifies the mathematics considered in modeling transmission lines. A lossless line is defined as a transmission line that has no line resistance and no dielectric loss. This would imply that the conductors act like perfect conductors and the dielectric acts like a perfect dielectric. For a lossless line, ''R'' and ''G'' are both zero, so the equation for characteristic impedance derived above reduces to: :Z_\text = \sqrt~. In particular, Z_\text does not depend any more upon the frequency. The above expression is wholly real, since the imaginary term has canceled out, implying that Z_\text is purely resistive. For a lossless line terminated in Z_\text, there is no loss of current across the line, and so the voltage remains the same along the line. The lossless line model is a useful approximation for many practical cases, such as low-loss transmission lines and transmission lines with high frequency. For both of these cases, and are much smaller than and , respectively, and can thus be ignored. The solutions to the long line transmission equations include incident and reflected portions of the voltage and current: V = \frac e^ + \frac e^I = \frac e^ - \frac e^ When the line is terminated with its characteristic impedance, the reflected portions of these equations are reduced to 0 and the solutions to the voltage and current along the transmission line are wholly incident. Without a reflection of the wave, the load that is being supplied by the line effectively blends into the line making it appear to be an infinite line. In a lossless line this implies that the voltage and current remain the same everywhere along the transmission line. Their magnitudes remain constant along the length of the line and are only rotated by a phase angle.


Surge impedance loading

In
electric power transmission Electric power transmission is the bulk movement of electrical energy from a generating site, such as a power plant, to an electrical substation. The interconnected lines that facilitate this movement form a ''transmission network''. This is ...
, the characteristic impedance of a transmission line is expressed in terms of the surge impedance loading (SIL), or natural loading, being the power loading at which
reactive power Reactive may refer to: *Generally, capable of having a reaction (disambiguation) *An adjective abbreviation denoting a bowling ball coverstock made of reactive resin *Reactivity (chemistry) *Reactive mind *Reactive programming See also *Reactanc ...
is neither produced nor absorbed: :\mathit=\frac in which V_\mathrm is the RMS line-to-line voltage in volts. Loaded below its SIL, the voltage at the load will be greater than the system voltage. Above it, the load voltage is depressed. The Ferranti effect describes the voltage gain towards the remote end of a very lightly loaded (or open ended) transmission line. Underground cables normally have a very low characteristic impedance, resulting in an SIL that is typically in excess of the thermal limit of the cable.


Practical examples

The characteristic impedance of
coaxial cable Coaxial cable, or coax (pronounced ) is a type of electrical cable consisting of an inner conductor surrounded by a concentric conducting shield, with the two separated by a dielectric ( insulating material); many coaxial cables also have a p ...
s (coax) is commonly chosen to be for RF and microwave applications. Coax for video applications is usually for its lower loss.


See also

* * * Iterative impedance, characteristic impedance is a limiting case of this * * *


References


Sources

* * * *


External links

{{DEFAULTSORT:Impedance, Characteristic Electricity Physical quantities Distributed element circuits Transmission lines de:Leitungstheorie#Die allgemeine L.C3.B6sung der Leitungsgleichungen