HOME

TheInfoList



OR:

Cross-ventilation is a natural phenomena where
wind Wind is the natural movement of air or other gases relative to a planet's surface. Winds occur on a range of scales, from thunderstorm flows lasting tens of minutes, to local breezes generated by heating of land surfaces and lasting a few ...
, fresh air or a breeze enters upon an opening, such as a window, and flows directly through the space and exits through an opening on the opposite side of the building (where the
air pressure Atmospheric pressure, also known as barometric pressure (after the barometer), is the pressure within the atmosphere of Earth. The standard atmosphere (symbol: atm) is a unit of pressure defined as , which is equivalent to 1013.25 millibars, ...
is lower). This produces a cool stream of air and as well as a current across the room from the exposed area to the sheltered area. Other terms used for the effect include, cross-breeze, cross-draft, wind effect ventilation and cross-flow ventilation.Wind ventilation and cross ventilation
Connection Magazines
Windows or vents positioned on opposite sides of the room allow passive breezes a pathway through the structure, which circulate the air and provide passive cooling. Cross-ventilation is a wind-driven effect and requires no
energy In physics, energy (from Ancient Greek: ἐνέργεια, ''enérgeia'', “activity”) is the quantitative property that is transferred to a body or to a physical system, recognizable in the performance of work and in the form of hea ...
, in addition to being the most effective method of wind ventilation. A commonly used technique to remove
pollutants A pollutant or novel entity is a substance or energy introduced into the environment that has undesired effects, or adversely affects the usefulness of a resource. These can be both naturally forming (i.e. minerals or extracted compounds like o ...
and heat in an indoor environment, cross-ventilation can also decrease or even obviate the need for an air-conditioner and can improve indoor
air quality Air pollution is the contamination of air due to the presence of substances in the atmosphere that are harmful to the health of humans and other living beings, or cause damage to the climate or to materials. There are many different types ...
.


Process

The phenomena occurs when openings in an environment (including vehicles) or building (houses, factories, sheds, etc) are set on opposite or adjoining walls, which allow air to enter and exit, thus creating a current of air across the interior environment. There is also a
pressure Pressure (symbol: ''p'' or ''P'') is the force applied perpendicular to the surface of an object per unit area over which that force is distributed. Gauge pressure (also spelled ''gage'' pressure)The preferred spelling varies by country a ...
difference between the opposite sides of the establishment. The effect is mostly driven by the wind, whereby the air is pulled into the building on the
high pressure In science and engineering the study of high pressure examines its effects on materials and the design and construction of devices, such as a diamond anvil cell, which can create high pressure. By ''high pressure'' is usually meant pressures of th ...
windward Windward () and leeward () are terms used to describe the direction of the wind. Windward is ''upwind'' from the point of reference, i.e. towards the direction from which the wind is coming; leeward is ''downwind'' from the point of reference ...
part and is pushed out on the
low pressure In meteorology, a low-pressure area, low area or low is a region where the atmospheric pressure is lower than that of surrounding locations. Low-pressure areas are commonly associated with inclement weather (such as cloudy, windy, with possible ...
downwind side of the establishment (because of the pressure difference between the openings). A wind's effect on a structure creates regions that have positive pressure on the building's upwind area and a negative pressure on the downwind side. Thus, the building shape and local wind patterns are critical in making wind pressures that force airflow through its openings. If the windows on both sides of the buildings are opened, the overpressure on the side facing the wind, and/or low pressure on the adjacent protected side, will make a current of air through the room from the uncovered side towards the sheltered side. If there are windows on both sides in a building, cross ventilation is appropriate where the width of the room is up to five times the floor-to-ceiling height. If openings are only one side then wind-driven ventilation is more suited for structures where the width is around 2.5 times the floor to ceiling height.


Factors

Cross ventilation relies on many factors, such as the tightness of the establishment,
wind direction Wind direction is generally reported by the direction from which it originates. For example, a ''north'' or ''northerly'' wind blows from the north to the south. The exceptions are onshore winds (blowing onto the shore from the water) and offsho ...
and how much wind is available, its potential travel through chimneys, vents and other openings in the home.
Casement window A casement window is a window that is attached to its frame by one or more hinges at the side. They are used singly or in pairs within a common frame, in which case they are hinged on the outside. Casement windows are often held open using a ca ...
s can be installed to improve cross-breezes. Air quality may also affect cross ventilation. Although cross ventilation is generally more direct at its job than
stack ventilation Passive ventilation is the process of supplying air to and removing air from an indoor space without using mechanical systems. It refers to the flow of external air to an indoor space as a result of pressure differences arising from natural force ...
, its cons include its effects being unproductive on hot, still days, when it is most necessary. Moreover, cross ventilation is generally only suitable for narrow buildings. The contrasting height of the openings (walls, sill, panels or furniture) ordered by the space also immediately influence the level and velocity of ventilation.


Effectivity

Cross ventilation works well in climates with hotter temperatures, where the system allows continual changes of the air within the building, refreshing it and reducing the temperature inside the structure and also when the window on the windward side of the building is not opened as much as the one on the leeward side. Cross ventilation will not be efficacious if the windows are more than 12m apart and if a window is behind a door that is regularly shut. An opened window that faces a
prevailing wind In meteorology, prevailing wind in a region of the Earth's surface is a surface wind that blows predominantly from a particular direction. The dominant winds are the trends in direction of wind with the highest speed over a particular point on ...
and is conjugated with another window on the opposite side of a building will supply natural ventilation for fresh air. A decent and effective cross ventilation will remove heat from the interior and keep indoor air temperatures approximately 1.5 C° (2.7 F°) below the outdoor air temperatures, ensuring that there is a steady inflow and outflow of fresh air inside the building. Besides windows,
brise soleil ''Brise soleil'', sometimes ''brise-soleil'' (; ), is an architectural feature of a building that reduces heat gain within that building by deflecting sunlight. More recently, vertical Brise soleil have become popular. Both systems allow low- ...
s, doors,
louver A louver (American English) or louvre (British English; see spelling differences) is a window blind or shutter with horizontal slats that are angled to admit light and air, but to keep out rain and direct sunshine. The angle of the slats ...
s or ventilation grills and ducts can also work as effective ventilation openings, though an awning window provides the least effectivity. The wind surrounding building structures is important when it comes to assessing the air quality and thermal comfort indoors since both air and heat exchange rely heavily on the wind pressure on the exterior of the building. For the best airflow, the windward windows of the occupied space should not be opened as much as those on the leeward side. Disadvantages of wind-driven ventilation include capricious
wind speed In meteorology, wind speed, or wind flow speed, is a fundamental atmospheric quantity caused by air moving from high to low pressure, usually due to changes in temperature. Wind speed is now commonly measured with an anemometer. Wind spee ...
s and directions (which may create a strong unpleasant draft), and the polluted air from the outside that may tarnish the
indoor air quality Indoor air quality (IAQ) is the air quality within and around buildings and structures. IAQ is known to affect the health, comfort, and well-being of building occupants. Poor indoor air quality has been linked to sick building syndrome, reduce ...
.


Types

There are four different types of cross ventilation:ENERGY EFFICIENCY MEASURES - HME09 – NATURAL VENTILATION
International Finance Corporation
*Single-sided ventilation: This method depends on the pressure contrasts between different openings within the occupied space. For rooms that only feature a single opening, the ventilation is impelled by turbulence, thereby creating a pumping activity on that lone opening, causing small inflows and outflows. It is worth noting that single-sided ventilation has a weak effect. It is preferable when cross ventilation is not achievable, where it uses windows or vents at the other side of the space to control air pressure. *Cross-ventilation (single spaces): Being unsophisticated and efficacious, this type of ventilation is a horizontal process that is driven by pressure differences between the windward and leeward sides of the occupied indoor environment. Ventilation here is generally provided using windows and vents at either side of a building where the variation in pressure draw air in and out. *Cross-ventilation (double-banked spaces): Involving banked rooms, this method features openings in the
hallway A hallway or corridor is an interior space in a building that is used to connect other rooms. Hallways are generally long and narrow. Hallways must be sufficiently wide to ensure buildings can be evacuated during a fire, and to allow people i ...
structure. The openings allow a way for noise to move between spaces. It can provide a much higher air-exchange rate in comparison with single-sided ventilation. *Stack ventilation: This ventilation is a vertical process and it's beneficiary for taller buildings with central atriums. It draws cooler air in at a lower level, whereby the air rises thereafter due to heat exposure before it is ventilated out at a higher level. Benefits from temperature compartmentalization and related pressure quality of the air, whereby warm air loses
density Density (volumetric mass density or specific mass) is the substance's mass per unit of volume. The symbol most often used for density is ''ρ'' (the lower case Greek letter rho), although the Latin letter ''D'' can also be used. Mathematicall ...
when it rises and the cooler air supplants it.


Equation

For a simple volume with two openings, the cross wind flow rate can be calculated using the following equation: Q = U_\sqrt\qquad\left(1\right) where U_ is the far-field wind speed; C_ is a local pressure drag coefficient for the building, defined at the location of the upstream opening; C_ is a local pressure drag coefficient for the building, defined at the location of the downstream opening; A_ is the cross-sectional area of the upstream opening; A_ is the cross-sectional area of the downstream opening; C_ is the discharge coefficient of the upstream opening; and C_ is the discharge coefficient of the downstream opening. For rooms with single opening, the calculation of ventilation rate is more complicated than cross-ventilation due to the bi-directional flow and strong turbulent effect. The ventilation rate for single-sided ventilation can be accurately predicted by combining different models for mean flow, pulsating flow and eddy penetration. The mean flow rate for single-sided ventilation is determined by: \bar = \frac \; \bar where ''l'' = width of the window; ''h'' = elevation of the top edge of the window; ''z''0 = elevation of neural level (where inside and outside pressure balance); ''z''ref = reference elevation where the wind velocity is measured (at 10 m) and \bar = mean wind velocity at the reference elevation. As observed in the equation (1), the air exchange depends linearly on the wind speed in the urban place where the architectural project will be built. CFD (
Computational Fluid Dynamics Computational fluid dynamics (CFD) is a branch of fluid mechanics that uses numerical analysis and data structures to analyze and solve problems that involve fluid flows. Computers are used to perform the calculations required to simulate t ...
) tools and zonal modelings are usually used to design naturally ventilated buildings.
Windcatcher A windcatcher, wind tower, or wind scoop ( ar, برجيل ; fa, بادگیر) is a traditional architectural element used to create cross ventilation and passive cooling in buildings. Windcatchers come in various designs: unidirectional, b ...
s can assist wind-driven ventilation by guiding air in and out of structures.


See also

*
Windcatcher A windcatcher, wind tower, or wind scoop ( ar, برجيل ; fa, بادگیر) is a traditional architectural element used to create cross ventilation and passive cooling in buildings. Windcatchers come in various designs: unidirectional, b ...
*
Passive cooling Passive cooling is a building design approach that focuses on heat gain control and heat dissipation in a building in order to improve the indoor thermal comfort with low or no energy consumption. This approach works either by preventing heat from ...
*
Passive ventilation Passive ventilation is the process of supplying air to and removing air from an indoor space without using mechanical systems. It refers to the flow of external air to an indoor space as a result of pressure differences arising from natural force ...
*
Indoor air quality Indoor air quality (IAQ) is the air quality within and around buildings and structures. IAQ is known to affect the health, comfort, and well-being of building occupants. Poor indoor air quality has been linked to sick building syndrome, reduce ...
* Room air distribution *
Thermal comfort Thermal comfort is the condition of mind that expresses satisfaction with the thermal environment and is assessed by subjective evaluation ( ANSI/ASHRAE Standard 55).ANSI/ASHRAE Standard 55-2017, Thermal Environmental Conditions for Human Occupan ...
*
Stack effect The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other containers, resulting from air buoyancy. Buoyancy occurs due to a difference in indoor-to-outdoor ...


References

{{HVAC , state=collapsed Ventilation Heating, ventilation, and air conditioning Sustainable building Building engineering Fluid dynamics Passive cooling Passive ventilation Architectural elements Low-energy building Cooling technology Physical phenomena