A colocation centre (also spelled co-location, or shortened to colo) or "carrier hotel", is a type of
data centre where equipment, space, and bandwidth are available for rental to retail customers. Colocation facilities provide space, power, cooling, and
physical security
Physical security describes security measures that are designed to deny unauthorized access to facilities, equipment, and resources and to protect personnel and property from damage or harm (such as espionage, theft, or terrorist attacks). Physi ...
for the
server,
storage, and
networking equipment of other firms and also connect them to a variety of
telecommunications
Telecommunication, often used in its plural form or abbreviated as telecom, is the transmission of information over a distance using electronic means, typically through cables, radio waves, or other communication technologies. These means of ...
and
network service providers with a minimum of cost and complexity. The term "carrier hotel" can refer to a data center focused on connecting customer and carrier networks together. Colocation centers often host
private peering connections between their customers, internet transit providers, cloud providers,
meet-me rooms for connecting customers together
Internet exchange point
Internet exchange points (IXes or IXPs) are common grounds of Internet Protocol, IP networking, allowing participant Internet service provider, Internet service providers (ISPs) to exchange data destined for their respective networks. IXPs are ...
s, and landing points and terminal equipment for fiber optic
submarine communication cables, connecting the internet, for example at the network access point known as
NAP of the Americas, which connects many Latin American ISPs with networks in the US.
Configuration
Many colocation providers sell to a wide range of customers, ranging from large enterprises to small companies. Typically, the customer owns the
information technology
Information technology (IT) is a set of related fields within information and communications technology (ICT), that encompass computer systems, software, programming languages, data processing, data and information processing, and storage. Inf ...
(IT) equipment and the facility provides power and cooling. Customers retain control over the design and usage of their equipment, but daily management of the data centre and facility are overseen by the multi-tenant colocation provider. They may also have a network operations center (NOC), a help desk, and offices for customer employees, and they may offer remote hands or smart hands service in which on site technicians employed by the colocation provider are allowed to access customer equipment on request to solve customer issues. Some providers also provide roof access to customers for mounting wireless equipment.
* Cabinets – A cabinet is a locking unit that holds a
server rack. In a multi-tenant data centre, servers within cabinets share
raised-floor space with other tenants, in addition to sharing power and cooling infrastructure. Some providers sell half cabinets or quarter cabinets as well as space for single servers or rack units.
* Cages – A cage is dedicated server space within a traditional raised-floor data centre; it is surrounded by mesh walls and entered through a locking door. Cages share power and cooling infrastructure with other data centre tenants.
* Suites – A suite is a dedicated, private server space within a traditional raised-floor data centre; it is fully enclosed by solid partitions and entered through a locking door. Suites may share power and cooling infrastructure with other data center tenants, or have these resources provided on a dedicated basis.
* Modules –
data center modules are purpose-engineered modules and components to offer scalable data center capacity. They typically use standardized components, which make them easily added, integrated or retrofitted into existing data centers, and cheaper and easier to build. In a colocation environment, the data center module is a data center within a data center, with its own steel walls and security protocol, and its own cooling and power infrastructure. "A number of colocation companies have praised the modular approach to data centers to better match customer demand with physical build outs, and allow customers to buy a data center as a service, paying only for what they consume."
Building features
Buildings with data centres inside them are often easy to recognize by the amount of cooling equipment located outside or on the roof.

Colocation facilities have many other special characteristics:
*
Fire protection
Fire protection is the study and practice of mitigating the unwanted effects of potentially Conflagration, destructive fires. It involves the study of the behaviour, Compartmentalization (fire protection), compartmentalisation, suppression and inve ...
systems, including
passive and active elements, as well as implementation of
fire prevention
Fire prevention is a function of many fire departments. The goal of fire prevention is to educate the public on the precautions that should be taken to prevent potentially harmful fires from occurring. It is a proactive method of preventing fir ...
programmes in operations.
Smoke detectors are usually installed to provide early warning of a developing fire by detecting particles generated by smouldering components prior to the development of flame. This allows investigation, interruption of power, and manual fire suppression using hand held fire extinguishers before the fire grows to a large size. A
fire sprinkler system
A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used on ...
is often provided to control a full scale fire if it develops.
Clean agent fire suppression gaseous systems are sometimes installed to suppress a fire earlier than the fire sprinkler system. Passive fire protection elements include the installation of
fire walls around the space, so a fire can be restricted to a portion of the facility for a limited time in the event of the failure of the active fire protection systems, or if they are not installed.
*
19-inch racks for data equipment and servers, 21-inch racks or
23-inch racks for telecommunications equipment
* Cabinets and cages for physical access control over tenants' equipment. Depending on one's needs a cabinet can house individual or multiple racks.
* Overhead or underfloor cable rack (tray) and fibreguide, power cables usually on separate rack from data
*
Air conditioning
Air conditioning, often abbreviated as A/C (US) or air con (UK), is the process of removing heat from an enclosed space to achieve a more comfortable interior temperature, and in some cases, also controlling the humidity of internal air. Air c ...
is used to control the temperature and humidity in the space.
ASHRAE recommends a temperature range and humidity range for optimal electronic equipment conditions versus environmental issues. The electrical power used by the electronic equipment is converted to heat, which is rejected to the ambient air in the data centre space. Unless the heat is removed, the ambient temperature will rise, resulting in electronic equipment malfunction. By controlling the space air temperature, the server components at the board level are kept within the manufacturer's specified temperature and humidity range. Air conditioning systems help keep equipment space
humidity
Humidity is the concentration of water vapor present in the air. Water vapor, the gaseous state of water, is generally invisible to the human eye. Humidity indicates the likelihood for precipitation (meteorology), precipitation, dew, or fog t ...
within acceptable parameters by cooling the return space air below the
dew point
The dew point is the temperature the air needs to be cooled to (at constant pressure) in order to produce a relative humidity of 100%. This temperature depends on the pressure and water content of the air. When the air at a temperature above the ...
. Too much humidity and water may begin to
condense on internal components. In case of a dry atmosphere, ancillary humidification systems may add water vapour to the space if the humidity is too low, to avoid
static electricity
Static electricity is an imbalance of electric charges within or on the surface of a material. The charge remains until it can move away by an electric current or electrical discharge. The word "static" is used to differentiate it from electric ...
discharge problems which may damage components.
* Low-impedance electrical
ground
* Few, if any, windows
Colocation data centres are often audited to prove that they attain certain standards and levels of reliability; the most commonly seen systems are
SSAE 16 SOC 1 Type I and Type II (formerly
SAS 70 Type I and Type II) and the tier system by the Uptime Institute or TIA. For service organizations today, SSAE 16 calls for a description of its "system". This is far more detailed and comprehensive than SAS 70's description of "controls". Other data center compliance standards include
Health Insurance Portability and Accountability Act
The Health Insurance Portability and Accountability Act of 1996 (HIPAA or the Ted Kennedy, Kennedy–Nancy Kassebaum, Kassebaum Act) is a United States Act of Congress enacted by the 104th United States Congress and signed into law by President ...
(HIPAA) audit and PCI DSS Standards.
Power
Colocation facilities generally have
generators that start automatically when utility power fails, usually running on
diesel fuel
Diesel fuel, also called diesel oil, heavy oil (historically) or simply diesel, is any liquid fuel specifically designed for use in a diesel engine, a type of internal combustion engine in which fuel ignition takes place without a spark as a re ...
. These generators may have varying levels of redundancy, depending on how the facility is built. Generators do not start instantaneously, so colocation facilities usually have battery backup systems. In many facilities, the operator of the facility provides large inverters to provide AC power from the batteries. In other cases, customers may install smaller
UPSes in their racks.
Some customers choose to use equipment that is powered directly by 48 VDC (nominal) battery banks. This may provide better energy efficiency, and may reduce the number of parts that can fail, though the reduced voltage greatly increases necessary current, and thus the size (and cost) of power delivery wiring. An alternative to batteries is a
motor–generator
A motor–generator (an MG set) is a device for converting electrical power to another form. Motor–generator sets are used to convert frequency, voltage, or phase of power. They may also be used to isolate electrical loads from the elect ...
connected to a
flywheel and diesel engine.
Many colocation facilities can provide redundant, A and B power feeds to customer equipment, and high end servers and telecommunications equipment often can have two power supplies installed.
Colocation facilities are sometimes connected to multiple sections of the utility power grid for additional reliability.
Internal connections
Colocation facility owners have differing rules regarding cross-connects between their customers, some of whom may be carriers. These rules may allow customers to run such connections at no charge, or allow customers to order such connections for a monthly fee. They may allow customers to order cross-connects to carriers, but not to other customers. Some colocation centres feature a "
meet-me-room" where the different carriers housed in the centre can efficiently exchange data.
Most
peering points sit in colocation centres and because of the high concentration of servers inside larger colocation centres, most carriers will be interested in bringing direct connections to such buildings. In many cases, there will be a larger
Internet exchange point
Internet exchange points (IXes or IXPs) are common grounds of Internet Protocol, IP networking, allowing participant Internet service provider, Internet service providers (ISPs) to exchange data destined for their respective networks. IXPs are ...
hosted inside a colocation centre, where customers can connect for peering.